Search PubMedSearch

SEARCH · Search PubMed

Results for “Robotic training”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

220 recordsLinked to original sources

Effectiveness of passive vs. assistive robotic gait training on functional recovery and neuroplasticity post-stroke: A randomized controlled trial.

OBJECTIVE: This study seeks to compare the impacts of various robotic gait training (RAGT) modes on lower limb motor function recovery in stroke patients while exploring the corresponding neural mechanisms. DESIGN: A single-blind, randomized controlled trial. SETTING: Inpatient Rehabilitation Facility. PARTICIPANTS: Forty-eight patients aged 18-80 who had experienced their first unilateral subacute stroke accompanied by walking impairments were included. INTERVENTIONS: Participants were randomly assigned to: (1) assistive mode training, (2) passive mode training, or (3) control group receiving only traditional rehabilitation. Clinical and neurological outcomes were assessed at pre-intervention (T0), and post-2-week intervention (T1). MAIN OUTCOME MEASURES: Outcomes were evaluated using the Fugl-Meyer Assessment for Lower Extremity, Berg Balance Scale, Modified Barthel Index, the Functional Ambulatory Category, and functional near-infrared spectroscopy. RESULTS: Among the 48 patients recruited, significant time effects were observed across all groups in FMA-LE scores (p&#x202f;<&#x202f;0.001). Notable improvements were detected in the conventional group (MD = 2.69, p&#xff1c;0.01) and the passive group (MD = 3.67, p&#x202f;<&#x202f;0.001), with the assistive mode also demonstrating a significant effect (MD = 1.79, p&#x202f;<&#x202f;0.05). BBS scores improved across all groups; however, no significant differences were noted between the groups (p&#x202f;=&#x202f;0.11). Similarly, MBI scores showed a significant time effect (p&#x202f;<&#x202f;0.001), without notable group differences (p&#x202f;=&#x202f;0.29). CONCLUSION: All training modalities effectively enhanced motor function, balance, and daily living skills in stroke patients. Distinct cortical activation and connectivity patterns were observed between training modalities, which may reflect different neuroplastic mechanisms. These preliminary neural differences may help inform personalized rehabilitation strategies, although no clinical superiority of one mode over another can be concluded from the present data.

Humans

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 &#xb1; 11.3&#xa0;years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield &#x2265;12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Humans

The Effect of Robot-Assisted Gait Training on Balance, Gait and Kinesiophobia in Individuals With Post-Stroke Hemiparesis: A Randomized Controlled Trial.

BACKGROUND AND PURPOSE: Robot-assisted gait training (RAGT) is well established for post-stroke gait rehabilitation, but its potential effects on psychological and behavioral outcomes are less clear. This study investigated the effects of adding RAGT to conventional rehabilitation on balance, gait, kinesiophobia, and movement confidence in individuals with post-stroke hemiparesis. METHODS: This single-blind, parallel-group randomized controlled trial included 60 individuals with post-stroke hemiparesis (50-75&#xa0;years), randomly allocated to an RAGT group (n&#xa0;=&#xa0;30) or control group (n&#xa0;=&#xa0;30). Ethical approval was obtained from the Clinical Research Ethics Committee of Istanbul Yeni Y&#xfc;zy&#x131;l University (Approval No. 20.01.2022/05; approval date: 20 January 2022). Both groups received conventional rehabilitation for 8&#xa0;weeks; the RAGT group additionally received 24 sessions of RAGT. Kinesiophobia was a prespecified study outcome assessed using the Kinesiophobia Causes Scale (KCS); balance, gait, and balance confidence were also assessed. All 60 randomized participants completed follow-up and were analyzed in their assigned groups. RESULTS: Significant group&#xa0;&#xd7;&#xa0;time interactions were observed for several outcomes, including BBS, TUG duration, 10MWT walking speed, ABC, and KCS total score (p&#xa0;<&#xa0;0.05). The between-group difference in change for KCS total score was -0.36 (95% CI: -0.51 to -0.21; partial eta squared&#xa0;=&#xa0;0.292). In post hoc analyses adjusting each outcome for its baseline value, significant group effects remained for BBS, TUG duration, 10MWT walking speed, ABC, KCS biological domain, and KCS total score (p< = 0.031), whereas 10MWT step count and the KCS psychological domain were no longer statistically significant. DISCUSSION: Adding RAGT to conventional rehabilitation was associated with greater improvements in several balance, mobility, walking-speed, balance-confidence, and kinesiophobia outcomes compared with conventional rehabilitation alone. These findings suggest potential additional physical and psychological benefits of incorporating RAGT into post-stroke rehabilitation. However, because the RAGT group received greater overall treatment exposure, the observed between-group differences cannot be attributed solely to the robotic component. The principal contribution of this study is the concurrent evaluation of kinesiophobia and movement confidence alongside physical outcomes.

Aged

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Delphi study robot consenso: Strategies for the implementation of robotic surgery in general surgery in the Spanish hospital network.

INTRODUCTION: The implementation of robotic surgery in public hospitals presents multiple logistical, educational, and organizational challenges. In the absence of unified guidelines, a national consensus is required to optimize its safe and efficient adoption. This study aimed to establish a set of consensus-based and measurable recommendations for the implementation of robotic surgery programs in hospitals within the Spanish National Health System, based on the experience of centres with established robotic programs and intended to serve as guidance for hospitals that are initiating or planning their implementation. METHODS: A national Delphi study was conducted with the participation of robotic surgery experts from 26 public hospitals. The expert panel was composed exclusively of digestive surgeons with experience in robotic surgery. Three iterative rounds of expert panel evaluation were conducted between March 2024 and March 2025. The questions were grouped into five thematic blocks. Consensus was defined as an agreement level of &#x2265;66.7%. Kendall's W coefficient was used to assess concordance. RESULTS: High levels of consensus were achieved on key aspects related to infrastructure, structured training, cost evaluation, and quality assurance mechanisms. Areas of disagreement were also identified, such as the need for a dedicated anaesthesiologist, purchase of accessory instruments during the initial phase, and official accreditation pathways. CONCLUSIONS: This study provides a guideline for developing a national robotic surgery strategy focused on patient safety, program sustainability, and standardized training of surgical teams. These recommendations can guide hospitals at different stages of robotic technology adoption. Given that the consensus was reached from an exclusively surgical perspective, the recommendations focus on patient safety, program sustainability, and standardized training of the surgical team, and should be interpreted in an adaptable manner according to each centre's context, case volume, and available resources.

Cirug&#xed;a Asistida por Robot

Could the preoperative urethral curve be used to predict immediate urinary continence following Retzius-sparing robot-assisted radical prostatectomy? A retrospective multi-center study.

PURPOSE: Immediate urinary continence (UC) recovery following Retzius-sparing robot-assisted radical prostatectomy (RS-RARP) remains highly variable, highlighting the need for reliable preoperative prediction. We aimed to develop and validate models to identify patients likely to achieve immediate UC recovery following RS-RARP. MATERIALS AND METHODS: A total of 580 prostate cancer patients who underwent RS-RARP from four medical centers were assigned to a training set (n=348), an internal validation set (n=103) and an external validation set (n=129). Independent predictors were identified through univariate analysis and LASSO regression. A nomogram was constructed using multivariate logistic regression. Its performance was evaluated with receiver operating characteristic (ROC) curve, calibration curves, and decision curve analysis. RESULTS: Immediate UC recovery was observed in 84.5% (294/348) of patients in the training cohort, 80.6% (83/103) in the internal validation cohort, and 81.4% (105/129) in the external validation cohort, respectively. Multivariate analysis identified membranous urethral length (MUL) (OR=1.23, P=0.029) and urethral curvature (OR=2.84, P<0.001) as independent predictors, while prostate volume (PV) (OR=0.84, P <0.001) as a protective factor. The nomogram integrating MUL, PV, and urethral curvature demonstrated superior predictive accuracy, with an AUC of 0.87 (95% CI, 0.83-0.91) in the training cohort. The bootstrap-corrected calibration slope was 0.96, and the Brier score was 0.08.&#xa0;Calibration curves and decision curve analysis confirmed the predictive accuracy and clinical utility of the nomogram. CONCLUSIONS: Our study introduces a novel quantitative method for assessing urethral curvature. The mpMRI-based model, integrating urethral curvature and prostate spatial configuration, offers enhanced predictive accuracy for postoperative immediate UC recovery.

Humans

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.

Robotic surgery is used for selected gastric gastrointestinal stromal tumours (GISTs), particularly when location makes conventional wedge resection difficult. We synthesised technical, perioperative, pathological, functional and oncological outcomes. PubMed/MEDLINE, Scopus and the Cochrane Library were searched from inception to 14 August 2026. Primary reports with at least three eligible robotic gastric-GIST patients were included. Two reviewers independently selected studies, extracted data and completed design-specific JBI appraisal. Because outcome definitions, denominators and reporting were heterogeneous, findings were synthesised narratively in accordance with SWiM guidance rather than pooled. Twenty-three studies, including six comparative cohorts, were included. Institutional robotic cohorts contained 3-45 eligible patients; one national registry included 1,567 robotic cases. Tumour size ranged from 2.68&#x2009;&#xb1;&#x2009;1.55 to 7.9&#x2009;&#xb1;&#x2009;1.8&#xa0;cm among studies reporting means. Most institutional reports described R0 resection in all eligible patients; exceptions were 23/24 and 24/25, while the registry reported 1,425/1,567 R0 resections. Grade III morbidity occurred in 2/25 patients in one function-preserving series. Registry 30- and 90-day mortality after robotic resection were 0.5% and 0.8%, respectively. Comparative studies did not demonstrate superior postoperative or oncological outcomes with robotic surgery. Robotic gastric-GIST resection appears feasible in selected patients and may facilitate organ-preserving surgery at anatomically challenging sites. Current observational evidence does not establish comparative functional, oncological or economic superiority.

Humans

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.

This review examined whether robotic assistance alters postoperative leg-length discrepancy (LLD), acetabular cup orientation, or early hip-specific outcomes relative to conventional total hip arthroplasty (THA). We searched PubMed and Web of Science through May 2026 for comparative English-language reports. Study eligibility, data extraction, and methodological appraisal were undertaken independently by two reviewers. Mean differences (MDs) and 95% confidence intervals (CIs) were calculated in Review Manager 5.4. Model selection was based on the target estimand and anticipated clinical and methodological diversity; leave-one-out and alternative-model sensitivity analyses were undertaken for heterogeneous outcomes. The protocol is registered with PROSPERO (CRD420261454043). The review included seven studies and 968 participants. Compared with conventional THA, robot-assisted THA yielded a smaller postoperative LLD (MD = -2.02, 95% CI -3.46 to -0.58; P = 0.006) and a higher Harris Hip Score (MD = 2.96, 95% CI 1.12 to 4.80; P = 0.002). Mean cup anteversion was lower in the robotic group (MD = -1.52, 95% CI -2.29 to -0.76; P < 0.0001), whereas cup inclination did not differ (MD = -0.71, 95% CI -3.26 to 1.83; P = 0.58). The robotic group also had higher Forgotten Joint Score (MD = 14.68, 95% CI 5.02 to 24.33; P = 0.003) and Oxford Hip Score values (MD = 2.61, 95% CI 0.71 to 4.51; P = 0.007). Robotic assistance was linked to a modest improvement in leg-length restoration and to higher scores on several early functional measures. The limited number of studies, predominance of nonrandomized designs, and marked heterogeneity in some analyses temper the certainty of these findings.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.

Robot-assisted guidance may improve the technical precision of percutaneous cannulated-screw fixation for femoral neck fractures. Whether these procedural advantages translate into better clinical outcomes remains uncertain. We compared robot-assisted and conventional freehand fixation in adults with femoral neck fractures. MEDLINE, Embase and CINAHL were searched from inception to 15 July 2026 without language restrictions. Google Scholar was used only as a supplementary search source, together with forward and backward citation searching. Comparative studies of robot-assisted versus freehand fluoroscopy-guided cannulated-screw fixation were included. Risk of bias was assessed using RoB 2 and ROBINS-I, with the Newcastle-Ottawa Scale used as a complementary appraisal of non-randomised studies. Random-effects meta-analyses included prediction intervals and prespecified sensitivity analyses. The protocol was registered prospectively (PROSPERO CRD420261465038). Sixteen comparative studies involving 1,293 participants were included. Of these, 597 underwent robot-assisted fixation and 696 underwent freehand fixation. Two studies reporting random allocation and 14 non-randomised studies were included in the study. Robot-assisted fixation was associated with fewer guide-wire manipulations, greater screw-placement accuracy and 13.9 fewer fluoroscopic acquisitions per procedure (95% confidence interval [CI] -20.3 to -7.5). Earlier radiographic healing and modestly higher final Harris Hip Scores were also observed. Pooled estimates suggested lower risks of union failure, avascular necrosis and composite complications. Fluoroscopy duration, overall operative time and reoperation did not differ significantly. Heterogeneity was substantial for several continuous outcomes, with prediction intervals crossing the null for several estimates, indicating that the magnitude of benefit varied considerably between studies. Some clinical associations were also sensitive to eligibility-restricted analyses. Robot-assisted cannulated-screw fixation improves technical execution compared with freehand fixation. Patient-important clinical superiority and economic value have not been established, and evidence concerning learning curves, operator acceptability and system reliability remains insufficient. Current evidence does not support routine widespread adoption; adequately powered multicentre randomised trials incorporating economic and implementation evaluation are required.

Humans

Interhospital transfer and outcomes after robotic emergency general surgery: a national analysis.

The outcomes of patients transferred to receiving centers who subsequently undergo robotic EGS remain uncharacterized at a national level. We aimed to quantify the association between transfer and outcomes among adults undergoing robotic EGS. We performed a retrospective cohort study of the Nationwide Readmissions Database (2016-2019) including adult nonelective admissions undergoing robotic EGS. Interhospital transfer versus direct admission was the exposure. Survey-weighted logistic regression estimated adjusted odds ratios (aOR) for clinical outcomes; generalized linear models with gamma family and log link estimated adjusted mean ratios (aMR) for length of stay (LOS) and cost. Average marginal effects provided adjusted risks/means and absolute differences. Among 26,869 unweighted robotic EGS admissions, representing an estimated 46,517 admissions nationally, 246 unweighted admissions were interhospital transfers, representing an estimated 444 transfers (1.0%) nationally. Transfers were older, more comorbid, and more severely ill and were treated predominantly at large, teaching hospitals. After adjustment, transfer was associated with a higher risk of postprocedural complications (8.0% vs. 3.5%; aRR 2.26, 95% CI 1.25-3.27), non-home discharge (31.2% vs. 18.9%; aRR 1.65, 95% CI 1.38-1.92), longer LOS (11.49 vs. 5.53 days; AMR 2.08, 95% CI 1.78-2.42), and higher cost ($43,340 vs. $21,821; AMR 1.99, 95% CI 1.68-2.35). The association with postprocedural complications was attenuated after additional adjustment for APR-DRG Severity of Illness, whereas associations with non-home discharge, LOS, and cost persisted. Among patients undergoing robotic EGS, interhospital transfer is independently associated with higher complication burden and greater resource use. Transferred patients represent a small but distinctly high-risk subgroup whose worse outcomes may reflect drivers that extend beyond the choice of surgical approach.

Humans

Artificial intelligence enabled social robotic interventions (PARO) in Australian dementia care: A systematic review and meta-analysis.

BACKGROUND: Although there is a growing body of research indicating that Personal Robot/Social Robot could be used in various aspects of care for individuals with dementia, little is known about how well these types of interventions work in an actual hospital setting in Australia. AIMS & OBJECTIVES: The objective of the present systematic review and meta-analysis is to assess the effectiveness of PARO-based socially assistive robotic intervention in terms of its effectiveness outcomes towards the reduction of dementia-related behavioural and psychological symptoms in Australian based healthcare settings. METHODS: A systematic search was conducted across five electronic databases, including MEDLINE (PubMed), EMBASE, CINAHL, PsycINFO, and the Cochrane Library, to identify randomised controlled trials (RCTs) investigating PARO-based socially assistive robotic interventions for dementia in Australian healthcare settings. This review was registered with PROSPERO (CRD420251251916) and followed the PRISMA 2020 guidelines. In addition, the Cochrane Risk of Bias tool (RoB 2) was used to evaluate the risk of bias across all studies. Pooled standardised mean differences (SMD) with 95&#xa0;% confidence intervals (CI) were calculated for agitation, anxiety, and depression. Heterogeneity across studies was evaluated using the I2 statistic. RESULTS: Six RCTs involving 1444 participants were identified for inclusion in this review. AI-enabled socially assistive robotic interventions, specifically the PARO therapeutic robot, significantly reduced agitation and anxiety when compared to standard treatment or control conditions. The pooled analysis showed that agitation [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.70, -0.18) p&#xa0;=&#xa0;0.0008] and anxiety [SMD&#xa0;=&#xa0;-0.59 (95&#xa0;% CI: -0.91, -0.27) p&#xa0;=&#xa0;0.0003] were reduced significantly, while the decrease in depression [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.95, -0.07) p&#xa0;=&#xa0;0.09] scores was non-significant among dementia patients receiving PARO-based socially assistive robotic interventions as compared to the control. The overall risk of bias across all six studies was considered low to moderate. CONCLUSION: PARO-based socially assistive robotic interventions may provide preliminary evidence of effectiveness in reducing agitation and anxiety in individuals with dementia in Australian healthcare, but the evidence regarding the reduction of depression remains unclear. Therefore, additional high-quality trials with consistent methodology and extended follow-up will be necessary to determine both the short-term and long-term clinical efficacy and practicality of implementing these interventions into practice.

Humans

Perioperative safety and survival outcomes of robot-assisted partial nephrectomy in elderly patients with localized renal cell carcinoma: an overlap-weighted Asian cohort study.

The value of robot-assisted partial nephrectomy (RAPN) in elderly Asian patients with localized renal cell carcinoma (RCC) remains insufficiently defined. We retrospectively analyzed 339 patients (&#x2265;&#x2009;70 years) with localized RCC treated at a single Asian center between 2015 and 2025, including 119 undergoing partial nephrectomy (PN) and 220 undergoing radical nephrectomy (RN). Propensity score overlap weighting (OW) was applied to compare PN versus RN and, within the PN cohort, RAPN versus laparoscopic partial nephrectomy (LPN). Three open partial nephrectomy cases were summarized descriptively and retained only in exploratory sensitivity analyses. Weighted logistic regression and Cox models with robust standard errors evaluated Clavien-Dindo grade&#x2009;&#x2265;&#x2009;II complications and overall survival (OS). After OW, PN was associated with better early postoperative renal functional preservation than RN but a greater incidence of grade&#x2009;&#x2265;&#x2009;II complications (36.4% vs. 17.6%; weighted p&#x2009;<&#x2009;0.001); OS was similar. Within the PN cohort, RAPN had longer operative time than LPN (weighted p&#x2009;=&#x2009;0.030), whereas warm ischemia time, early postoperative eGFR, and grade&#x2009;&#x2265;&#x2009;II complications (31.8% vs. 40.4%; weighted p&#x2009;=&#x2009;0.414) were not significantly different. Exploratory analyses favored RAPN, but only one death occurred in this group, and residual confounding remains possible. PN may preserve early renal function in selected older patients, while RAPN appears feasible in experienced centers; its survival association remains hypothesis-generating.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n&#x2009;=&#x2009;18) or conventional RP (n&#x2009;=&#x2009;22). Eligible patients were &#x2265;&#x2009;18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16&#xa0;min compared to conventional RP (38 vs. 54&#xa0;min, p&#x2009;=&#x2009;0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans

The Impact of Video Game Experience on Surgical Performance: A Systematic Review.

OBJECTIVE: To assess whether video gaming experience is associated with improved surgical performance in the surgeon population across laparoscopic, robotic, and other surgical modalities, and evaluate its implications on surgical training and education. METHODS: A structured literature search was conducted across five databases on 29th November 2024 in adherence to PRISMA guidelines. Comparative studies evaluating surgical performance outcome data between surgeons with differing video game experience were eligible for inclusion. Outcomes evaluated were time to complete task, error rate, accuracy, economy of motion, and overall score. Included studies were assessed for risk of bias using ROBINS-I and RoB 2. RESULTS: 15 studies involving 641 participants were included, comprising one randomized controlled trial and 14 nonrandomized studies. All nonrandomized studies were judged to be at moderate or serious risk of bias, and the single randomized controlled trial was judged to be at serious risk of bias. Differences in study design and outcome measures meant that quantitative synthesis could not be performed. Across laparoscopic studies, video gaming experience was associated with improved overall score and time to task completion predominantly in the period prior to structured training interventions, with accuracy findings consistently favoring gamers in the two studies reporting this outcome. Error rate and economy of motion findings were inconsistent or predominantly nonsignificant. No meaningful association was identified across nonlaparoscopic modalities. CONCLUSIONS: Video gaming may be associated with improved surgical performance in surgeons, though this appears restricted to laparoscopic tasks and the pretraining intervention period. As a low-cost and accessible activity, video gaming may represent a practical informal adjunct to formal surgical training to help ease the transition into structured technical training. Surgical program directors need not alter existing selection criteria or training modules based on the available literature.

Video Games

Comparison of clinical outcomes of robotic versus open pyeloplasty in infants under 6 months.

INTRODUCTION: Robotic pyeloplasties have become the popular approach for surgical repair of ureteropelvic junction obstruction (UPJO) in the pediatric population. In infants less than 6 months old, there is concern for lack of intra-abdominal working space and lack of benefit compared to an open approach. Our aim was to compare the peri-operative and post-operative outcomes of patients undergoing open versus robotic pyeloplasty under six months of age. METHODS: A retrospective review was performed of patients less than six months of age undergoing robotic or open pyeloplasty between 2020 and 2024 at a single institution. Patient demographics and clinical outcomes were collected and compared. Surgical success was defined as a >50% reduction in the antero-pelvic diameter (APD) of the affected kidney at one year post pyeloplasty. RESULTS: A total of 32 patients were identified (16 robotic and 16 open), median age at surgery was 4 months old. There was no significant difference in length of hospital stay or narcotic usage between the two groups. The robotic cohort had a significantly longer operative time (209.5 min vs 142.5 min, p < 0.001) compared to the open cohort. There was no significant difference between post-operative complication or surgical success rates between the two groups. CONCLUSION: In this small series, robotic and open pyeloplasty both remain viable options for infants less than 6 months of age with equivalent surgical outcomes and lengths of hospital stay.

Humans