Search PubMedSearch

PubMed · 42678645

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Abstract

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d = 2.381 mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44 mm (95% CI, 4.02-6.86 mm; p = 2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p = 5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p = 0.26) or cognitive workload via the NASA-Task Load Index (p = 0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Explore related subjects

Keep this discovery

BibTeXRIS

Jose O Romero, Sudi A Zhao, Michaela M Geffert, Ehsan Nasiri, Elizabeth C Anderson, Yuan Shi, Phoebe S Xu, Michael A Kokko, Ryan J Halter, Joseph A Paydarfar. 2026-09-01. A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.. https://doi.org/10.1007/s11701-026-03893-6

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Herd-level heterogeneity of antimicrobial resistance in commensal Escherichia coli: A nationwide high-throughput survey of Australian pig herds.

Antimicrobial resistance in commensal Escherichia coli provides a useful indicator for overall antimicrobial resistance burden. We applied this approach to assess antimicrobial resistance within and between commercial pig herds across Australia. A high-throughput robotic workflow was used to isolate 2730 E. coli colonies from rectal contents collected in 2022 from healthy slaughter pigs (n = 300) representing 30 herds (∼70% of national production). Up to 94 isolates per herd underwent antimicrobial susceptibility testing using the Robotic Antimicrobial Susceptibility Platform. Isolate- and herd-level antimicrobial resistance indices were calculated, weighting antimicrobials by their human health importance. Resistance to first-line agents was widespread: ampicillin 77% and tetracycline 79%. By contrast, resistance to critically important antimicrobials was rare (ciprofloxacin 0.11%; extended-spectrum cephalosporins 0.04%), and no clinical resistance to carbapenems or colistin was detected. Overall, 56.9% of isolates were multi-class resistant. Herd-level antimicrobial resistance within indices ranged from 1.51 to 5.76, revealing substantial between-herd heterogeneity. Three herds carried critically important antimicrobials-resistant isolates that would likely have been missed using conventional, lower-density sampling approaches. Whole-genome sequencing identified fluoroquinolone-resistant isolates belonging to ST10 and ST69 (both qnrS1), and ST744 (Quinolone Resistance Determining Region mutations plus blaCTX-M-27). By testing approximately tenfold more isolates than conventional surveys, we uncovered considerable antimicrobial resistance with heterogeneity within and between animals and herds, including farm-specific variability. This expanded sampling also enabled detection of critically important antimicrobial resistance at very low prevalence. In conclusion, high-throughput, high-density testing offers a practical early-warning system and herd-level benchmark to inform surveillance and targeted interventions.

Animals

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n = 18) or conventional RP (n = 22). Eligible patients were ≥ 18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16 min compared to conventional RP (38 vs. 54 min, p = 0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans