Search PubMedSearch

PubMed · 42742817

Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.

Abstract

This review examined whether robotic assistance alters postoperative leg-length discrepancy (LLD), acetabular cup orientation, or early hip-specific outcomes relative to conventional total hip arthroplasty (THA). We searched PubMed and Web of Science through May 2026 for comparative English-language reports. Study eligibility, data extraction, and methodological appraisal were undertaken independently by two reviewers. Mean differences (MDs) and 95% confidence intervals (CIs) were calculated in Review Manager 5.4. Model selection was based on the target estimand and anticipated clinical and methodological diversity; leave-one-out and alternative-model sensitivity analyses were undertaken for heterogeneous outcomes. The protocol is registered with PROSPERO (CRD420261454043). The review included seven studies and 968 participants. Compared with conventional THA, robot-assisted THA yielded a smaller postoperative LLD (MD = -2.02, 95% CI -3.46 to -0.58; P = 0.006) and a higher Harris Hip Score (MD = 2.96, 95% CI 1.12 to 4.80; P = 0.002). Mean cup anteversion was lower in the robotic group (MD = -1.52, 95% CI -2.29 to -0.76; P < 0.0001), whereas cup inclination did not differ (MD = -0.71, 95% CI -3.26 to 1.83; P = 0.58). The robotic group also had higher Forgotten Joint Score (MD = 14.68, 95% CI 5.02 to 24.33; P = 0.003) and Oxford Hip Score values (MD = 2.61, 95% CI 0.71 to 4.51; P = 0.007). Robotic assistance was linked to a modest improvement in leg-length restoration and to higher scores on several early functional measures. The limited number of studies, predominance of nonrandomized designs, and marked heterogeneity in some analyses temper the certainty of these findings.

Explore related subjects

Keep this discovery

BibTeXRIS

Zhi-Yan Cao, Li Sun, Kun Yuan, Chu Chen, Bai-Hong Cui. 2026-09-15. Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.. https://doi.org/10.1007/s11701-026-03920-6

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Risk prediction models for blood transfusion in patients undergoing total hip and knee arthroplasty: a systematic review and meta-analysis.

OBJECTIVE: To systematically review and evaluate published risk prediction models for perioperative blood transfusion in patients undergoing total hip or knee arthroplasty (THA/TKA). METHODS: We systematically searched PubMed, Web of Science, the Cochrane Library, and Embase from inception to May 31, 2025. Two researchers independently screened the literature, extracted data, and assessed the risk of bias and applicability using the Prediction model Risk Of Bias Assessment Tool (PROBAST). The area under the receiver operating characteristic curve (AUC) values were pooled via a meta-analysis using Stata 18.0. RESULTS: d Fourteen studies containing 36 prediction models were included. The incidence of blood transfusion among THA/TKA patients ranged from 3.2% to 30.8%. Preoperative hemoglobin (Hb) level, tranexamic acid (TXA) use, operative duration, intraoperative blood loss, and age were the most frequently incorporated predictors. Model sensitivity ranged from 58% to 94.5%, and specificity ranged from 71.3% to 94%. Meta-analysis showed that the pooled AUC value of the 13 validated models was 0.87 (95% CI: 0.85-0.90), suggesting good discriminatory performance. All models were rated as having a high risk of bias. The applicability of four studies was rated as unclear. CONCLUSION: Although the included studies demonstrated promising discriminative ability of prediction models for blood transfusion in THA/TKA, all were assessed as having a high risk of bias using the PROBAST tool. Therefore, future research should prioritize the development of models with larger sample sizes, rigorous study designs, and multicenter external validation.

Humans

Anti-inflammatory agents after hip and shoulder arthroplasty: A systematic review and meta-analysis.

BACKGROUND: Postoperative inflammation after arthroplasty contributes to pain, delayed mobilization and prolonged hospitalization. Recent randomized trials have evaluated pharmacological anti-inflammatory strategies within contemporary enhanced recovery pathways, but evidence after hip and shoulder arthroplasty remains scattered across different drug classes and perioperative regimens. OBJECTIVES: To synthesize recent randomized controlled trial (RCT) evidence on perioperative anti-inflammatory agents after hip and shoulder arthroplasty. METHODS: PubMed, Embase, Cochrane Library and Web of Science were searched for English-language RCTs published from January 2020 to March 2026. The 2020-2026 window was selected to update evidence generated under modern arthroplasty, anesthesia, multimodal analgesia and enhanced recovery after surgery (ERAS) pathways. Eligible trials included adults undergoing hip or shoulder arthroplasty and compared corticosteroids, cyclooxygenase-2 (COX-2) inhibitors, nonsteroidal anti-inflammatory drug (NSAID)-based/local anti-inflammatory regimens, or related anti-inflammatory interventions with placebo, saline, no treatment, or the same regimen without the target component. Weighted mean differences (WMDs) were pooled using random-effects models. RESULTS: Nine RCTs involving 800 patients were included. Anti-inflammatory interventions significantly reduced postoperative C-reactive protein (CRP) [WMD=-32.18, 95% confidence interval (CI) (-41.16, -23.21), P<0.001], interleukin-6 (IL-6) [WMD=-31.25, 95% CI (-41.79, -20.77), P<0.001], rest pain [WMD=-0.41, 95% CI (-0.58, -0.23), P<0.001], activity pain [WMD=-0.56, 95% CI (-0.83, -0.29), P<0.001] and hospital stay [WMD=-0.54, 95% CI (-0.92, -0.15), P=0.006]. CONCLUSION: Recent RCT evidence suggests that perioperative anti-inflammatory interventions can attenuate early inflammatory responses and improve short-term pain and recovery after hip and shoulder arthroplasty. Because data were limited and clinically heterogeneous, the findings should not be interpreted as evidence favoring a specific drug class, dose, route, or timing.

Humans

Systematic Review on the Effectiveness of Photobiomodulation Therapy on Enhancing Musculoskeletal Rehabilitation Outcomes after Total Knee and Hip Arthroplasty.

BACKGROUND: Total knee and hip arthroplasty (TKA/THA) effectively alleviate chronic pain and improve joint function and quality of life. However, postoperative recovery is often hindered by pain, edema, restricted range of motion (ROM), and muscle weakness, necessitating structured physical rehabilitation. Photobiomodulation Therapy (PBMT) has been proposed as an adjunct modality to enhance rehabilitation outcomes. This systematic review evaluates the efficacy of PBMT in reducing postoperative pain and edema as well as improving ROM and functional performance compared with placebo or standard physical therapy in post-arthroplasty patients. METHODS: A systematic search of PubMed, ProQuest, ScienceDirect, and Google Scholar was conducted from inception to May 31, 2025. Only prospective controlled trials assessing PBMT effects on postoperative pain, swelling, ROM, or functional performance following TKA or THA were included. Case reports, uncontrolled studies, and trials focusing on unrelated outcomes were excluded. Article selection involved title, abstract, and full-text screening, with additional studies identified through reference lists. The review is registered in PROSPERO (CRD420251123169). RESULTS: Four randomized controlled trials (RCTs; n = 133 participants) met the inclusion criteria, three studies focused on TKA, and one study examined THA. PBMT significantly improved postoperative pain and edema reduction in three trials, while two studies demonstrated enhanced ROM and functional outcomes compared with control or placebo interventions. PEDro scores ranged from 8 to 10, indicating moderate-to-high methodological quality. CONCLUSIONS: PBMT shows promising short-term benefits in reducing postoperative pain and swelling and improving functional performance after knee or hip arthroplasty. However, due to heterogeneity in treatment parameters and limited high-quality trials, conclusive evidence remains insufficient. Future large-scale RCTs with standardized PBMT parameters and extended follow-up are warranted to confirm its clinical efficacy.

Humans