Search PubMedSearch

PubMed · 42678442

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Abstract

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 ± 11.3 years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield ≥12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Explore related subjects

Keep this discovery

BibTeXRIS

Mohamed Amin, Mohamed Abosheisha, Mohamed Salama, Stanley Nwabuoku, Alex Brown, Michael Lim. 2026-09-01. Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.. https://doi.org/10.1007/s11701-026-03886-5

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Comparison of clinical outcomes of robotic versus open pyeloplasty in infants under 6 months.

INTRODUCTION: Robotic pyeloplasties have become the popular approach for surgical repair of ureteropelvic junction obstruction (UPJO) in the pediatric population. In infants less than 6 months old, there is concern for lack of intra-abdominal working space and lack of benefit compared to an open approach. Our aim was to compare the peri-operative and post-operative outcomes of patients undergoing open versus robotic pyeloplasty under six months of age. METHODS: A retrospective review was performed of patients less than six months of age undergoing robotic or open pyeloplasty between 2020 and 2024 at a single institution. Patient demographics and clinical outcomes were collected and compared. Surgical success was defined as a >50% reduction in the antero-pelvic diameter (APD) of the affected kidney at one year post pyeloplasty. RESULTS: A total of 32 patients were identified (16 robotic and 16 open), median age at surgery was 4 months old. There was no significant difference in length of hospital stay or narcotic usage between the two groups. The robotic cohort had a significantly longer operative time (209.5 min vs 142.5 min, p < 0.001) compared to the open cohort. There was no significant difference between post-operative complication or surgical success rates between the two groups. CONCLUSION: In this small series, robotic and open pyeloplasty both remain viable options for infants less than 6 months of age with equivalent surgical outcomes and lengths of hospital stay.

Humans

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans