Search PubMedSearch

PubMed · 42742860

Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.

Abstract

Robot-assisted guidance may improve the technical precision of percutaneous cannulated-screw fixation for femoral neck fractures. Whether these procedural advantages translate into better clinical outcomes remains uncertain. We compared robot-assisted and conventional freehand fixation in adults with femoral neck fractures. MEDLINE, Embase and CINAHL were searched from inception to 15 July 2026 without language restrictions. Google Scholar was used only as a supplementary search source, together with forward and backward citation searching. Comparative studies of robot-assisted versus freehand fluoroscopy-guided cannulated-screw fixation were included. Risk of bias was assessed using RoB 2 and ROBINS-I, with the Newcastle-Ottawa Scale used as a complementary appraisal of non-randomised studies. Random-effects meta-analyses included prediction intervals and prespecified sensitivity analyses. The protocol was registered prospectively (PROSPERO CRD420261465038). Sixteen comparative studies involving 1,293 participants were included. Of these, 597 underwent robot-assisted fixation and 696 underwent freehand fixation. Two studies reporting random allocation and 14 non-randomised studies were included in the study. Robot-assisted fixation was associated with fewer guide-wire manipulations, greater screw-placement accuracy and 13.9 fewer fluoroscopic acquisitions per procedure (95% confidence interval [CI] -20.3 to -7.5). Earlier radiographic healing and modestly higher final Harris Hip Scores were also observed. Pooled estimates suggested lower risks of union failure, avascular necrosis and composite complications. Fluoroscopy duration, overall operative time and reoperation did not differ significantly. Heterogeneity was substantial for several continuous outcomes, with prediction intervals crossing the null for several estimates, indicating that the magnitude of benefit varied considerably between studies. Some clinical associations were also sensitive to eligibility-restricted analyses. Robot-assisted cannulated-screw fixation improves technical execution compared with freehand fixation. Patient-important clinical superiority and economic value have not been established, and evidence concerning learning curves, operator acceptability and system reliability remains insufficient. Current evidence does not support routine widespread adoption; adequately powered multicentre randomised trials incorporating economic and implementation evaluation are required.

Explore related subjects

Keep this discovery

BibTeXRIS

Gaurav Jha, Amrita Dhar, Aftab Arif, Amit Bishnoi. 2026-09-15. Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.. https://doi.org/10.1007/s11701-026-03938-w

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d = 2.381 mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44 mm (95% CI, 4.02-6.86 mm; p = 2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p = 5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p = 0.26) or cognitive workload via the NASA-Task Load Index (p = 0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Hip Arthroscopy-Assisted Management of Pipkin Types I and II Femoral Head Fracture-Dislocations: Mid-Term Clinical and Radiographic Outcomes.

OBJECTIVES: Hip arthroscopy-assisted surgery has been proposed as a minimally invasive option for femoral head fractures; however, evidence with mid-term follow-up remains limited. This study aimed to evaluate the clinical and radiographic outcomes of arthroscopy-assisted management for Pipkin Types I and II femoral head fracture-dislocations with a minimum follow-up of 5 years. METHODS: This retrospective study included 23 consecutive adults (19 Pipkin I and 4 Pipkin II) treated with hip arthroscopy-assisted fragment excision or internal fixation between March 2013 and January 2020. Preoperative computed tomography was used for surgical planning, and fixation was placed with arthroscopic headless screws. Clinical outcomes were assessed using the Harris Hip Score (HHS) and Thompson-Epstein (T-E) criteria. Radiographic evaluation included avascular necrosis (AVN), heterotopic ossification (HO; Brooker), osteoarthritis (OA; Tönnis), and fracture reduction quality (Matta's criteria). Group comparisons were evaluated using independent samples t-tests, Mann-Whitney U tests, and Fisher's exact test. The mean follow-up was 86.2 ± 21.2 months. RESULTS: The cohort consisted of 19 males and 4 females with a mean age of 28.7 ± 9.9 years. Fifteen patients underwent fixation and eight underwent excision. The final mean HHS was 98.3 ± 1.9, with 21 patients (91%) achieving excellent and 2 (9%) good T-E criteria. There were no significant differences between the fixation and excision groups in demographic characteristics, operative time, or functional outcomes (all p > 0.05); however, hospital stay was significantly shorter in the excision group (2.9 ± 0.6 vs. 5.5 ± 4.6 days, p = 0.028). In the fixation group, mean maximal displacement improved from 7.6 mm preoperatively to 2.6 mm postoperatively, with anatomic reduction achieved in 6 cases (40%), imperfect in 6 (40%), and poor in 3 (20%). Patients with Pipkin Type I fractures had significantly higher HHS than those with Type II fractures (98.7 ± 1.7 vs. 96.0 ± 0.8, p = 0.018). Complications were rare, with one case of Brooker Grade I HO and one case of mild OA. No AVN or total hip arthroplasty occurred during the follow-up. CONCLUSIONS: Hip arthroscopy-assisted management of selected Pipkin Type I and II femoral head fractures yields excellent mid-term clinical outcomes with acceptable radiographic reduction and a low complication rate. This minimally invasive technique represents a viable alternative in appropriately selected patients when fragment characteristics and surgical expertise permit.

Humans

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans