Search PubMedSearch

PubMed · 42730783

Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.

Abstract

Robotic surgery is used for selected gastric gastrointestinal stromal tumours (GISTs), particularly when location makes conventional wedge resection difficult. We synthesised technical, perioperative, pathological, functional and oncological outcomes. PubMed/MEDLINE, Scopus and the Cochrane Library were searched from inception to 14 August 2026. Primary reports with at least three eligible robotic gastric-GIST patients were included. Two reviewers independently selected studies, extracted data and completed design-specific JBI appraisal. Because outcome definitions, denominators and reporting were heterogeneous, findings were synthesised narratively in accordance with SWiM guidance rather than pooled. Twenty-three studies, including six comparative cohorts, were included. Institutional robotic cohorts contained 3-45 eligible patients; one national registry included 1,567 robotic cases. Tumour size ranged from 2.68 ± 1.55 to 7.9 ± 1.8 cm among studies reporting means. Most institutional reports described R0 resection in all eligible patients; exceptions were 23/24 and 24/25, while the registry reported 1,425/1,567 R0 resections. Grade III morbidity occurred in 2/25 patients in one function-preserving series. Registry 30- and 90-day mortality after robotic resection were 0.5% and 0.8%, respectively. Comparative studies did not demonstrate superior postoperative or oncological outcomes with robotic surgery. Robotic gastric-GIST resection appears feasible in selected patients and may facilitate organ-preserving surgery at anatomically challenging sites. Current observational evidence does not establish comparative functional, oncological or economic superiority.

Explore related subjects

Keep this discovery

BibTeXRIS

Konstantinos Kossenas, Nikolaos Koliakos, Dimitrios Papakonstantinou, Georgios D Lianos, Nikolaos Memos, Pantelis Antonakis, Efstathios Kotidis, Grigorios Christodoulidis, Dimitrios Schizas. 2026-09-12. Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.. https://doi.org/10.1007/s11701-026-03949-7

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d = 2.381 mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44 mm (95% CI, 4.02-6.86 mm; p = 2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p = 5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p = 0.26) or cognitive workload via the NASA-Task Load Index (p = 0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n = 18) or conventional RP (n = 22). Eligible patients were ≥ 18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16 min compared to conventional RP (38 vs. 54 min, p = 0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans