Search PubMedSearch

SEARCH · Search PubMed

Results for “Robotic platforms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

150 recordsLinked to original sources

Beyond da Vinci: a systematic review of next-generation multiport robotic platforms in pediatric surgery.

As robotic surgery expands beyond the da Vinci platform, the relevance of new-generation systems to pediatric patients remains uncertain. This review examined the technical characteristics, applications, and perioperative outcomes of alternative multiport robotic platforms in children. PubMed/MEDLINE, Web of Science, Scopus, and the Cochrane Library were searched through 28 February 2026 in accordance with PRISMA 2020. Owing to clinical heterogeneity, findings were synthesized narratively, with Wilson 95% confidence intervals for key binary outcomes. Six studies reported 166 patients across 27 procedure types. Senhance accounted for 164 patients, while Hugo RAS and Hinotori were each represented by one patient. Ages ranged from 15 days to 17 years and weights from 3.8 to more than 100 kg. Senhance was the only platform used with 3-mm robotic instruments. Conversion or planned escalation occurred in 19 patients (11.4%; 95% CI, 7.5-17.2%). Four intraoperative complications were reported (2.4%; 95% CI, 0.9-6.0%). Across all reports, 20 patients experienced postoperative complications (12.0%; 95% CI, 7.9-17.9%). In the largest cohort, seven patients required reintervention (4.6%; 95% CI, 2.2-9.2%) and seven were readmitted (4.6%; 95% CI, 2.2-9.2%). No deaths or comparative pediatric studies were reported. Published experience remains sparse and is almost entirely limited to Senhance. Current evidence describes early clinical use without establishing comparative safety, effectiveness, or platform superiority. Prospective multicenter studies with standardized reporting are needed.

Humans

Herd-level heterogeneity of antimicrobial resistance in commensal Escherichia coli: A nationwide high-throughput survey of Australian pig herds.

Antimicrobial resistance in commensal Escherichia coli provides a useful indicator for overall antimicrobial resistance burden. We applied this approach to assess antimicrobial resistance within and between commercial pig herds across Australia. A high-throughput robotic workflow was used to isolate 2730 E. coli colonies from rectal contents collected in 2022 from healthy slaughter pigs (n = 300) representing 30 herds (∼70% of national production). Up to 94 isolates per herd underwent antimicrobial susceptibility testing using the Robotic Antimicrobial Susceptibility Platform. Isolate- and herd-level antimicrobial resistance indices were calculated, weighting antimicrobials by their human health importance. Resistance to first-line agents was widespread: ampicillin 77% and tetracycline 79%. By contrast, resistance to critically important antimicrobials was rare (ciprofloxacin 0.11%; extended-spectrum cephalosporins 0.04%), and no clinical resistance to carbapenems or colistin was detected. Overall, 56.9% of isolates were multi-class resistant. Herd-level antimicrobial resistance within indices ranged from 1.51 to 5.76, revealing substantial between-herd heterogeneity. Three herds carried critically important antimicrobials-resistant isolates that would likely have been missed using conventional, lower-density sampling approaches. Whole-genome sequencing identified fluoroquinolone-resistant isolates belonging to ST10 and ST69 (both qnrS1), and ST744 (Quinolone Resistance Determining Region mutations plus blaCTX-M-27). By testing approximately tenfold more isolates than conventional surveys, we uncovered considerable antimicrobial resistance with heterogeneity within and between animals and herds, including farm-specific variability. This expanded sampling also enabled detection of critically important antimicrobial resistance at very low prevalence. In conclusion, high-throughput, high-density testing offers a practical early-warning system and herd-level benchmark to inform surveillance and targeted interventions.

Animals

Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.

Robotic surgery is used for selected gastric gastrointestinal stromal tumours (GISTs), particularly when location makes conventional wedge resection difficult. We synthesised technical, perioperative, pathological, functional and oncological outcomes. PubMed/MEDLINE, Scopus and the Cochrane Library were searched from inception to 14 August 2026. Primary reports with at least three eligible robotic gastric-GIST patients were included. Two reviewers independently selected studies, extracted data and completed design-specific JBI appraisal. Because outcome definitions, denominators and reporting were heterogeneous, findings were synthesised narratively in accordance with SWiM guidance rather than pooled. Twenty-three studies, including six comparative cohorts, were included. Institutional robotic cohorts contained 3-45 eligible patients; one national registry included 1,567 robotic cases. Tumour size ranged from 2.68 ± 1.55 to 7.9 ± 1.8 cm among studies reporting means. Most institutional reports described R0 resection in all eligible patients; exceptions were 23/24 and 24/25, while the registry reported 1,425/1,567 R0 resections. Grade III morbidity occurred in 2/25 patients in one function-preserving series. Registry 30- and 90-day mortality after robotic resection were 0.5% and 0.8%, respectively. Comparative studies did not demonstrate superior postoperative or oncological outcomes with robotic surgery. Robotic gastric-GIST resection appears feasible in selected patients and may facilitate organ-preserving surgery at anatomically challenging sites. Current observational evidence does not establish comparative functional, oncological or economic superiority.

Humans

Delphi study robot consenso: Strategies for the implementation of robotic surgery in general surgery in the Spanish hospital network.

INTRODUCTION: The implementation of robotic surgery in public hospitals presents multiple logistical, educational, and organizational challenges. In the absence of unified guidelines, a national consensus is required to optimize its safe and efficient adoption. This study aimed to establish a set of consensus-based and measurable recommendations for the implementation of robotic surgery programs in hospitals within the Spanish National Health System, based on the experience of centres with established robotic programs and intended to serve as guidance for hospitals that are initiating or planning their implementation. METHODS: A national Delphi study was conducted with the participation of robotic surgery experts from 26 public hospitals. The expert panel was composed exclusively of digestive surgeons with experience in robotic surgery. Three iterative rounds of expert panel evaluation were conducted between March 2024 and March 2025. The questions were grouped into five thematic blocks. Consensus was defined as an agreement level of ≥66.7%. Kendall's W coefficient was used to assess concordance. RESULTS: High levels of consensus were achieved on key aspects related to infrastructure, structured training, cost evaluation, and quality assurance mechanisms. Areas of disagreement were also identified, such as the need for a dedicated anaesthesiologist, purchase of accessory instruments during the initial phase, and official accreditation pathways. CONCLUSIONS: This study provides a guideline for developing a national robotic surgery strategy focused on patient safety, program sustainability, and standardized training of surgical teams. These recommendations can guide hospitals at different stages of robotic technology adoption. Given that the consensus was reached from an exclusively surgical perspective, the recommendations focus on patient safety, program sustainability, and standardized training of the surgical team, and should be interpreted in an adaptable manner according to each centre's context, case volume, and available resources.

Cirugía Asistida por Robot

Hybrid robotic transversus abdominis release (hrTAR) for complex ventral hernias: a systematic review and preliminary synthesis.

Hybrid robotic transversus abdominis release (hrTAR) combines robotic posterior component separation with a planned limited open phase. Evidence supporting this strategy is sparse. Following PRISMA 2020, we searched PubMed, Embase, Scopus, and the Cochrane Library and registered the protocol in PROSPERO (CRD420261303285). Eligible studies reported hrTAR outcomes for ventral or incisional hernia repair. Findings were synthesized narratively; no pooled effect estimates were calculated. Three reports contained 85 hrTAR cohort entries. Because two reports came from the same institution and overlap could not be excluded, this total should not be interpreted as a unique-patient count. Surgical-site outcomes were heterogeneous: two reports used SSO endpoints (4% and 5%), whereas another reported surgical-site events in 25% of patients, including seroma and wound infection. Mean length of stay ranged from 1.8 to 3.7 days; the sample-size-weighted mean across studies reporting means was 2.9 days. One propensity-matched comparison reported shorter hospitalization and lower 30-day SSO with hrTAR than open TAR. No perioperative deaths or recurrences were reported during limited follow-up. hrTAR appears feasible in selected patients, but available evidence is exploratory. Standardized prospective multicenter studies with non-overlapping cohorts and longer follow-up are needed before comparative effectiveness, economic value, or wider adoption can be supported.

Humans

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Applications of artificial intelligence in robot-assisted surgery: a systematic review.

To characterize applications of artificial intelligence (AI) in robot-assisted surgery, summarize technical and clinical performance, and assess the quality of the available evidence. PubMed, Web of Science Core Collection, and Scopus were searched for English-language journal articles published from 1 January 2020 through 31 October 2025. Randomized, observational, model-development, validation, and feasibility studies evaluating AI in robot-assisted surgery or closely related image-guided minimally invasive workflows were eligible. Two reviewers independently performed study selection, data extraction, and risk-of-bias assessment. Owing to heterogeneity in surgical procedures, AI tasks, analytical units, validation strategies, and outcomes, findings were synthesized descriptively without statistical pooling. The review was registered in the International Prospective Register of Systematic Reviews (CRD420251175699). Seventeen studies were included: seven clinical prediction or decision-support studies, eight intraoperative recognition, segmentation, or image-guided studies, and two training or workflow studies. Five prediction studies reported area-under-the-curve values of 0.74-0.95. Technical studies reported F1 or Dice scores of 0.525-0.995 and task-specific accuracies of 0.840-0.998. Two randomized studies suggested benefits for personalized suturing feedback and automated camera control, but neither established improved patient outcomes. Only one study had low overall risk of bias; the remaining studies were at high or unclear risk or raised some concerns. AI applications in robot-assisted surgery show promise for prediction, intraoperative perception, training, and workflow support. Evidence primarily demonstrates technical feasibility rather than established clinical effectiveness. Independent multicenter validation and prospective evaluation of patient, educational, and workflow outcomes are required before widespread implementation.

Robotic Surgical Procedures

Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.

This review examined whether robotic assistance alters postoperative leg-length discrepancy (LLD), acetabular cup orientation, or early hip-specific outcomes relative to conventional total hip arthroplasty (THA). We searched PubMed and Web of Science through May 2026 for comparative English-language reports. Study eligibility, data extraction, and methodological appraisal were undertaken independently by two reviewers. Mean differences (MDs) and 95% confidence intervals (CIs) were calculated in Review Manager 5.4. Model selection was based on the target estimand and anticipated clinical and methodological diversity; leave-one-out and alternative-model sensitivity analyses were undertaken for heterogeneous outcomes. The protocol is registered with PROSPERO (CRD420261454043). The review included seven studies and 968 participants. Compared with conventional THA, robot-assisted THA yielded a smaller postoperative LLD (MD = -2.02, 95% CI -3.46 to -0.58; P = 0.006) and a higher Harris Hip Score (MD = 2.96, 95% CI 1.12 to 4.80; P = 0.002). Mean cup anteversion was lower in the robotic group (MD = -1.52, 95% CI -2.29 to -0.76; P < 0.0001), whereas cup inclination did not differ (MD = -0.71, 95% CI -3.26 to 1.83; P = 0.58). The robotic group also had higher Forgotten Joint Score (MD = 14.68, 95% CI 5.02 to 24.33; P = 0.003) and Oxford Hip Score values (MD = 2.61, 95% CI 0.71 to 4.51; P = 0.007). Robotic assistance was linked to a modest improvement in leg-length restoration and to higher scores on several early functional measures. The limited number of studies, predominance of nonrandomized designs, and marked heterogeneity in some analyses temper the certainty of these findings.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.

Robot-assisted guidance may improve the technical precision of percutaneous cannulated-screw fixation for femoral neck fractures. Whether these procedural advantages translate into better clinical outcomes remains uncertain. We compared robot-assisted and conventional freehand fixation in adults with femoral neck fractures. MEDLINE, Embase and CINAHL were searched from inception to 15 July 2026 without language restrictions. Google Scholar was used only as a supplementary search source, together with forward and backward citation searching. Comparative studies of robot-assisted versus freehand fluoroscopy-guided cannulated-screw fixation were included. Risk of bias was assessed using RoB 2 and ROBINS-I, with the Newcastle-Ottawa Scale used as a complementary appraisal of non-randomised studies. Random-effects meta-analyses included prediction intervals and prespecified sensitivity analyses. The protocol was registered prospectively (PROSPERO CRD420261465038). Sixteen comparative studies involving 1,293 participants were included. Of these, 597 underwent robot-assisted fixation and 696 underwent freehand fixation. Two studies reporting random allocation and 14 non-randomised studies were included in the study. Robot-assisted fixation was associated with fewer guide-wire manipulations, greater screw-placement accuracy and 13.9 fewer fluoroscopic acquisitions per procedure (95% confidence interval [CI] -20.3 to -7.5). Earlier radiographic healing and modestly higher final Harris Hip Scores were also observed. Pooled estimates suggested lower risks of union failure, avascular necrosis and composite complications. Fluoroscopy duration, overall operative time and reoperation did not differ significantly. Heterogeneity was substantial for several continuous outcomes, with prediction intervals crossing the null for several estimates, indicating that the magnitude of benefit varied considerably between studies. Some clinical associations were also sensitive to eligibility-restricted analyses. Robot-assisted cannulated-screw fixation improves technical execution compared with freehand fixation. Patient-important clinical superiority and economic value have not been established, and evidence concerning learning curves, operator acceptability and system reliability remains insufficient. Current evidence does not support routine widespread adoption; adequately powered multicentre randomised trials incorporating economic and implementation evaluation are required.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Interhospital transfer and outcomes after robotic emergency general surgery: a national analysis.

The outcomes of patients transferred to receiving centers who subsequently undergo robotic EGS remain uncharacterized at a national level. We aimed to quantify the association between transfer and outcomes among adults undergoing robotic EGS. We performed a retrospective cohort study of the Nationwide Readmissions Database (2016-2019) including adult nonelective admissions undergoing robotic EGS. Interhospital transfer versus direct admission was the exposure. Survey-weighted logistic regression estimated adjusted odds ratios (aOR) for clinical outcomes; generalized linear models with gamma family and log link estimated adjusted mean ratios (aMR) for length of stay (LOS) and cost. Average marginal effects provided adjusted risks/means and absolute differences. Among 26,869 unweighted robotic EGS admissions, representing an estimated 46,517 admissions nationally, 246 unweighted admissions were interhospital transfers, representing an estimated 444 transfers (1.0%) nationally. Transfers were older, more comorbid, and more severely ill and were treated predominantly at large, teaching hospitals. After adjustment, transfer was associated with a higher risk of postprocedural complications (8.0% vs. 3.5%; aRR 2.26, 95% CI 1.25-3.27), non-home discharge (31.2% vs. 18.9%; aRR 1.65, 95% CI 1.38-1.92), longer LOS (11.49 vs. 5.53 days; AMR 2.08, 95% CI 1.78-2.42), and higher cost ($43,340 vs. $21,821; AMR 1.99, 95% CI 1.68-2.35). The association with postprocedural complications was attenuated after additional adjustment for APR-DRG Severity of Illness, whereas associations with non-home discharge, LOS, and cost persisted. Among patients undergoing robotic EGS, interhospital transfer is independently associated with higher complication burden and greater resource use. Transferred patients represent a small but distinctly high-risk subgroup whose worse outcomes may reflect drivers that extend beyond the choice of surgical approach.

Humans

Artificial intelligence enabled social robotic interventions (PARO) in Australian dementia care: A systematic review and meta-analysis.

BACKGROUND: Although there is a growing body of research indicating that Personal Robot/Social Robot could be used in various aspects of care for individuals with dementia, little is known about how well these types of interventions work in an actual hospital setting in Australia. AIMS & OBJECTIVES: The objective of the present systematic review and meta-analysis is to assess the effectiveness of PARO-based socially assistive robotic intervention in terms of its effectiveness outcomes towards the reduction of dementia-related behavioural and psychological symptoms in Australian based healthcare settings. METHODS: A systematic search was conducted across five electronic databases, including MEDLINE (PubMed), EMBASE, CINAHL, PsycINFO, and the Cochrane Library, to identify randomised controlled trials (RCTs) investigating PARO-based socially assistive robotic interventions for dementia in Australian healthcare settings. This review was registered with PROSPERO (CRD420251251916) and followed the PRISMA 2020 guidelines. In addition, the Cochrane Risk of Bias tool (RoB 2) was used to evaluate the risk of bias across all studies. Pooled standardised mean differences (SMD) with 95&#xa0;% confidence intervals (CI) were calculated for agitation, anxiety, and depression. Heterogeneity across studies was evaluated using the I2 statistic. RESULTS: Six RCTs involving 1444 participants were identified for inclusion in this review. AI-enabled socially assistive robotic interventions, specifically the PARO therapeutic robot, significantly reduced agitation and anxiety when compared to standard treatment or control conditions. The pooled analysis showed that agitation [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.70, -0.18) p&#xa0;=&#xa0;0.0008] and anxiety [SMD&#xa0;=&#xa0;-0.59 (95&#xa0;% CI: -0.91, -0.27) p&#xa0;=&#xa0;0.0003] were reduced significantly, while the decrease in depression [SMD&#xa0;=&#xa0;-0.44 (95&#xa0;% CI: -0.95, -0.07) p&#xa0;=&#xa0;0.09] scores was non-significant among dementia patients receiving PARO-based socially assistive robotic interventions as compared to the control. The overall risk of bias across all six studies was considered low to moderate. CONCLUSION: PARO-based socially assistive robotic interventions may provide preliminary evidence of effectiveness in reducing agitation and anxiety in individuals with dementia in Australian healthcare, but the evidence regarding the reduction of depression remains unclear. Therefore, additional high-quality trials with consistent methodology and extended follow-up will be necessary to determine both the short-term and long-term clinical efficacy and practicality of implementing these interventions into practice.

Humans

Perioperative safety and survival outcomes of robot-assisted partial nephrectomy in elderly patients with localized renal cell carcinoma: an overlap-weighted Asian cohort study.

The value of robot-assisted partial nephrectomy (RAPN) in elderly Asian patients with localized renal cell carcinoma (RCC) remains insufficiently defined. We retrospectively analyzed 339 patients (&#x2265;&#x2009;70 years) with localized RCC treated at a single Asian center between 2015 and 2025, including 119 undergoing partial nephrectomy (PN) and 220 undergoing radical nephrectomy (RN). Propensity score overlap weighting (OW) was applied to compare PN versus RN and, within the PN cohort, RAPN versus laparoscopic partial nephrectomy (LPN). Three open partial nephrectomy cases were summarized descriptively and retained only in exploratory sensitivity analyses. Weighted logistic regression and Cox models with robust standard errors evaluated Clavien-Dindo grade&#x2009;&#x2265;&#x2009;II complications and overall survival (OS). After OW, PN was associated with better early postoperative renal functional preservation than RN but a greater incidence of grade&#x2009;&#x2265;&#x2009;II complications (36.4% vs. 17.6%; weighted p&#x2009;<&#x2009;0.001); OS was similar. Within the PN cohort, RAPN had longer operative time than LPN (weighted p&#x2009;=&#x2009;0.030), whereas warm ischemia time, early postoperative eGFR, and grade&#x2009;&#x2265;&#x2009;II complications (31.8% vs. 40.4%; weighted p&#x2009;=&#x2009;0.414) were not significantly different. Exploratory analyses favored RAPN, but only one death occurred in this group, and residual confounding remains possible. PN may preserve early renal function in selected older patients, while RAPN appears feasible in experienced centers; its survival association remains hypothesis-generating.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n&#x2009;=&#x2009;18) or conventional RP (n&#x2009;=&#x2009;22). Eligible patients were &#x2265;&#x2009;18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16&#xa0;min compared to conventional RP (38 vs. 54&#xa0;min, p&#x2009;=&#x2009;0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans

Sutureless versus renorrhaphy in robot-assisted off-clamp partial nephrectomy: a systematic review and meta-analysis.

BACKGROUND: The necessity of routine parenchymal renorrhaphy during off-clamp robot-assisted partial nephrectomy (RAPN) remains uncertain. This study aimed to compare perioperative, functional, safety, and oncological outcomes between sutureless and conventional renorrhaphy. METHODS: We conducted a systematic review and meta-analysis following PRISMA 2020 guidelines. Comparative studies evaluating sutureless versus conventional renorrhaphy during purely off-clamp RAPN were included. Trifecta achievement was the primary outcome. Random-effects models were used for pooled analyses, with subgroup analysis according to study design. RESULTS: Four studies involving 787 patients, including one randomized controlled trial (RCT) and three propensity score-matched (PSM) studies, were included. The overall pooled estimate showed no statistically significant difference in Trifecta achievement (RR 1.17, 95% CI 0.97-1.41), with substantial heterogeneity (I&#xb2; = 86.5%). The PSM studies favored the sutureless approach (RR 1.26, 95% CI 1.05-1.52), whereas the RCT yielded an RR of 0.97 (95% CI 0.92-1.04) and met the prespecified noninferiority criterion without demonstrating superiority. The sutureless approach was associated with a smaller perioperative eGFR decline (MD&#x2009;-&#x2009;3.89, 95% CI&#x2009;-&#x2009;6.16 to -&#x2009;1.62), while no significant difference was observed in eGFR at 3 months. No statistically significant differences were identified in major complications, blood transfusion, or positive surgical margins; urinary and vascular complications were sparsely reported. CONCLUSIONS: In selected patients undergoing purely off-clamp RAPN, randomized evidence supports the noninferiority of a strategy that omits routine parenchymal renorrhaphy while permitting clinically necessary selective repair, but does not demonstrate superiority. Favorable estimates from PSM studies remain vulnerable to intraoperative treatment-selection bias. Current evidence is insufficient to determine whether omission of renorrhaphy affects urinary complications, long-term renal function, or oncological outcomes. REGISTRATION: This systematic review was registered prospectively in PROSPERO (CRD420261435995).

Humans

Comparison of clinical outcomes of robotic versus open pyeloplasty in infants under 6 months.

INTRODUCTION: Robotic pyeloplasties have become the popular approach for surgical repair of ureteropelvic junction obstruction (UPJO) in the pediatric population. In infants less than 6 months old, there is concern for lack of intra-abdominal working space and lack of benefit compared to an open approach. Our aim was to compare the peri-operative and post-operative outcomes of patients undergoing open versus robotic pyeloplasty under six months of age. METHODS: A retrospective review was performed of patients less than six months of age undergoing robotic or open pyeloplasty between 2020 and 2024 at a single institution. Patient demographics and clinical outcomes were collected and compared. Surgical success was defined as a >50% reduction in the antero-pelvic diameter (APD) of the affected kidney at one year post pyeloplasty. RESULTS: A total of 32 patients were identified (16 robotic and 16 open), median age at surgery was 4 months old. There was no significant difference in length of hospital stay or narcotic usage between the two groups. The robotic cohort had a significantly longer operative time (209.5 min vs 142.5 min, p < 0.001) compared to the open cohort. There was no significant difference between post-operative complication or surgical success rates between the two groups. CONCLUSION: In this small series, robotic and open pyeloplasty both remain viable options for infants less than 6 months of age with equivalent surgical outcomes and lengths of hospital stay.

Humans

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 &#xb1; 11.3&#xa0;years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield &#x2265;12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Humans