239 recordsLinked to original sources

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d = 2.381 mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44 mm (95% CI, 4.02-6.86 mm; p = 2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p = 5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p = 0.26) or cognitive workload via the NASA-Task Load Index (p = 0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Positive Margin Rate Following Transoral Surgery in T2-T3 Laryngeal Carcinoma - a Systematic Review and Meta-Analysis.

BACKGROUND: Transoral endoscopic surgery, using either conventional laser techniques or supported by robotic assistance, represents an established treatment modality for selected patients with T2-T3 laryngeal carcinoma. The goal is complete tumor removal, as positive resection margins have been associated with worse oncological outcomes. This systematic review and meta-analysis aimed to determine the positive margin rate following transoral endoscopic surgery for T2-T3 laryngeal carcinoma and to evaluate its impact on oncologic outcomes. METHODS: A systematic search of Medline, Embase, Web of Science, Cochrane CENTRAL, and Google Scholar was performed from inception through March 2025, identifying studies reporting on surgical margin status after transoral resection of T2 and/or T3 laryngeal carcinoma. A random-effects meta-analysis of proportions was used to estimate a pooled positive margin rate. The oncologic impact of margin status is presented descriptively owing to data heterogeneity. RESULTS: Thirty-nine studies comprising 3,281 patients with T2-T3 laryngeal carcinoma met the inclusion criteria. The positive margin rate was 22.0% (95% CI 17.6 - 27.3, I2 = 83.8%) for the total T2-T3 cohort, with stratified rates of 22.4% for T2 and 30.8% for T3 tumors. Among the eight studies assessing the impact of positive margins in T2-T3 stages, three found a significant association with worse oncological outcomes. Conclusion A 22% positive margin rate was identified in T2-T3 laryngeal cancer treated with transoral endoscopic resection. However, the impact of margin status on oncological outcomes remains uncertain, largely due to challenges in sampling and histopathological assessment.

Humans

Effect of Smoking in Oropharyngeal Cancer Treated With TORS: Systematic Review and Meta-Analysis.

OBJECTIVE: While smoking has been implicated as a risk factor for recurrence in HPV-associated oropharyngeal squamous cell cancer (OPSCC) treated with definitive chemoradiation, its prognostic impact on surgically treated OPSCC is less clear. DATA SOURCES: MEDLINE, Embase, CENTRAL, and Scopus. REVIEW METHODS: Articles describing patients with HPV-associated OPSCC treated with transoral robotic surgery (TORS), which reported oncologic outcomes by smoking history, were included. RESULTS: 2079 patients were included across 12 studies. Median age was 58.5 years, and 1808 (87.0%) were male. HPV-associated disease was reported in 1681 (80.9%) patients. T stage was most commonly T2 in 831 (40.0%) and T1 in 764 (36.7%). N stage was N2 in 854 (41.1%), N1 in 544 (26.2%), and N0 in 307 (14.8%). 931 (44.8%) were considered individuals with a smoking history, while 1045 (50.3%) were considered without a smoking history. Median follow up was 33.7 months. Meta-analysis using a fixed effects model demonstrated an overall hazard ratio of 1.4 (95% confidence interval 1.0-2.0) for disease recurrence, 2.7 (95% confidence interval 1.5-4.8) for overall survival, and 1.4 (95% confidence interval 0.4-4.6) for disease specific survival. CONCLUSIONS: In this population of predominantly HPV-associated OPSCC treated with TORS, meta-analysis demonstrated no significant difference in recurrence-free survival or disease-specific survival between individuals with and without a smoking history. Individuals with a smoking history appeared to have worse overall survival, although only five studies reported on this outcome. Further research is required to clarify the prognostic influence of smoking on OPSCC treated with TORS.

Humans

Delphi study robot consenso: Strategies for the implementation of robotic surgery in general surgery in the Spanish hospital network.

INTRODUCTION: The implementation of robotic surgery in public hospitals presents multiple logistical, educational, and organizational challenges. In the absence of unified guidelines, a national consensus is required to optimize its safe and efficient adoption. This study aimed to establish a set of consensus-based and measurable recommendations for the implementation of robotic surgery programs in hospitals within the Spanish National Health System, based on the experience of centres with established robotic programs and intended to serve as guidance for hospitals that are initiating or planning their implementation. METHODS: A national Delphi study was conducted with the participation of robotic surgery experts from 26 public hospitals. The expert panel was composed exclusively of digestive surgeons with experience in robotic surgery. Three iterative rounds of expert panel evaluation were conducted between March 2024 and March 2025. The questions were grouped into five thematic blocks. Consensus was defined as an agreement level of ≥66.7%. Kendall's W coefficient was used to assess concordance. RESULTS: High levels of consensus were achieved on key aspects related to infrastructure, structured training, cost evaluation, and quality assurance mechanisms. Areas of disagreement were also identified, such as the need for a dedicated anaesthesiologist, purchase of accessory instruments during the initial phase, and official accreditation pathways. CONCLUSIONS: This study provides a guideline for developing a national robotic surgery strategy focused on patient safety, program sustainability, and standardized training of surgical teams. These recommendations can guide hospitals at different stages of robotic technology adoption. Given that the consensus was reached from an exclusively surgical perspective, the recommendations focus on patient safety, program sustainability, and standardized training of the surgical team, and should be interpreted in an adaptable manner according to each centre's context, case volume, and available resources.

Cirugía Asistida por Robot

Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.

Robotic surgery is used for selected gastric gastrointestinal stromal tumours (GISTs), particularly when location makes conventional wedge resection difficult. We synthesised technical, perioperative, pathological, functional and oncological outcomes. PubMed/MEDLINE, Scopus and the Cochrane Library were searched from inception to 14 August 2026. Primary reports with at least three eligible robotic gastric-GIST patients were included. Two reviewers independently selected studies, extracted data and completed design-specific JBI appraisal. Because outcome definitions, denominators and reporting were heterogeneous, findings were synthesised narratively in accordance with SWiM guidance rather than pooled. Twenty-three studies, including six comparative cohorts, were included. Institutional robotic cohorts contained 3-45 eligible patients; one national registry included 1,567 robotic cases. Tumour size ranged from 2.68 ± 1.55 to 7.9 ± 1.8 cm among studies reporting means. Most institutional reports described R0 resection in all eligible patients; exceptions were 23/24 and 24/25, while the registry reported 1,425/1,567 R0 resections. Grade III morbidity occurred in 2/25 patients in one function-preserving series. Registry 30- and 90-day mortality after robotic resection were 0.5% and 0.8%, respectively. Comparative studies did not demonstrate superior postoperative or oncological outcomes with robotic surgery. Robotic gastric-GIST resection appears feasible in selected patients and may facilitate organ-preserving surgery at anatomically challenging sites. Current observational evidence does not establish comparative functional, oncological or economic superiority.

Humans

Interhospital transfer and outcomes after robotic emergency general surgery: a national analysis.

The outcomes of patients transferred to receiving centers who subsequently undergo robotic EGS remain uncharacterized at a national level. We aimed to quantify the association between transfer and outcomes among adults undergoing robotic EGS. We performed a retrospective cohort study of the Nationwide Readmissions Database (2016-2019) including adult nonelective admissions undergoing robotic EGS. Interhospital transfer versus direct admission was the exposure. Survey-weighted logistic regression estimated adjusted odds ratios (aOR) for clinical outcomes; generalized linear models with gamma family and log link estimated adjusted mean ratios (aMR) for length of stay (LOS) and cost. Average marginal effects provided adjusted risks/means and absolute differences. Among 26,869 unweighted robotic EGS admissions, representing an estimated 46,517 admissions nationally, 246 unweighted admissions were interhospital transfers, representing an estimated 444 transfers (1.0%) nationally. Transfers were older, more comorbid, and more severely ill and were treated predominantly at large, teaching hospitals. After adjustment, transfer was associated with a higher risk of postprocedural complications (8.0% vs. 3.5%; aRR 2.26, 95% CI 1.25-3.27), non-home discharge (31.2% vs. 18.9%; aRR 1.65, 95% CI 1.38-1.92), longer LOS (11.49 vs. 5.53 days; AMR 2.08, 95% CI 1.78-2.42), and higher cost ($43,340 vs. $21,821; AMR 1.99, 95% CI 1.68-2.35). The association with postprocedural complications was attenuated after additional adjustment for APR-DRG Severity of Illness, whereas associations with non-home discharge, LOS, and cost persisted. Among patients undergoing robotic EGS, interhospital transfer is independently associated with higher complication burden and greater resource use. Transferred patients represent a small but distinctly high-risk subgroup whose worse outcomes may reflect drivers that extend beyond the choice of surgical approach.

Humans

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n = 18) or conventional RP (n = 22). Eligible patients were ≥ 18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16 min compared to conventional RP (38 vs. 54 min, p = 0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans

Robot-assisted bladder diverticulectomy in adults: a systematic review and pooled analysis of perioperative and functional outcomes.

Robot-assisted bladder diverticulectomy (RABD) is used for symptomatic acquired bladder diverticula, but evidence is dispersed across small single-centre series and the only dedicated systematic review dates from 2010. We reviewed contemporary perioperative and functional outcomes of RABD. Following a protocol registered on the Open Science Framework ( https://doi.org/10.17605/OSF.IO/54CFT ), PubMed, Embase, the Cochrane Library, Scopus and Web of Science were searched from inception to 30 August 2026 (initial search June 2026, re-run and broadened for this version), following PRISMA 2020. Eligible studies were original series of five or more adults undergoing robot-assisted bladder diverticulectomy reporting extractable outcomes. Two reviewers independently screened, extracted data and appraised risk of bias with the Joanna Briggs Institute checklist for case series, with third-reviewer adjudication. Binary outcomes were pooled as proportions with Wilson 95% confidence intervals (CI); continuous outcomes were summarised as patient-number-weighted descriptive values, because mixed median/mean reporting and clinical heterogeneity precluded a formal pooled-effect meta-analysis. Twelve studies (146 patients) were included and all outcomes were extracted from the full-text reports. A transperitoneal route was used throughout. There were no conversions to open surgery (0/129; 95% CI 0-2.9%). Major complications (Clavien-Dindo ≥ III) occurred in 3.0% (4/135; 95% CI 1.2-7.4%). Patient-number-weighted descriptive values (combining study-level medians and means, and therefore not a pooled mean) were: operative time 163 min, blood loss 99 mL, length of stay 3.6 days and catheter duration 7.7 days. Symptom scores and post-void residual improved in every reporting series, significantly in five. The single non-randomised comparison with open surgery reported fewer major complications after RABD (5% [1/20] vs. 50% [3/6], p = 0.007), but the open arm comprised only six patients and this finding should not be regarded as comparative evidence. Across these series, RABD was feasible with low reported short-term morbidity in selected patients: no conversions to open surgery were recorded in the studies reporting conversion status, the major-complication rate was low, and symptom scores and post-void residual improved in every series that measured them. A minority of patients had an incidentally detected intradiverticular tumour; oncological outcomes were not an endpoint of this review. Evidence remains limited by small, heterogeneous, mostly retrospective series, so these findings should be read as descriptive; prospective comparative data are warranted.

Humans

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 ± 11.3 years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield ≥12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Humans

Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.

This review examined whether robotic assistance alters postoperative leg-length discrepancy (LLD), acetabular cup orientation, or early hip-specific outcomes relative to conventional total hip arthroplasty (THA). We searched PubMed and Web of Science through May 2026 for comparative English-language reports. Study eligibility, data extraction, and methodological appraisal were undertaken independently by two reviewers. Mean differences (MDs) and 95% confidence intervals (CIs) were calculated in Review Manager 5.4. Model selection was based on the target estimand and anticipated clinical and methodological diversity; leave-one-out and alternative-model sensitivity analyses were undertaken for heterogeneous outcomes. The protocol is registered with PROSPERO (CRD420261454043). The review included seven studies and 968 participants. Compared with conventional THA, robot-assisted THA yielded a smaller postoperative LLD (MD = -2.02, 95% CI -3.46 to -0.58; P = 0.006) and a higher Harris Hip Score (MD = 2.96, 95% CI 1.12 to 4.80; P = 0.002). Mean cup anteversion was lower in the robotic group (MD = -1.52, 95% CI -2.29 to -0.76; P < 0.0001), whereas cup inclination did not differ (MD = -0.71, 95% CI -3.26 to 1.83; P = 0.58). The robotic group also had higher Forgotten Joint Score (MD = 14.68, 95% CI 5.02 to 24.33; P = 0.003) and Oxford Hip Score values (MD = 2.61, 95% CI 0.71 to 4.51; P = 0.007). Robotic assistance was linked to a modest improvement in leg-length restoration and to higher scores on several early functional measures. The limited number of studies, predominance of nonrandomized designs, and marked heterogeneity in some analyses temper the certainty of these findings.

Humans

Perioperative safety and survival outcomes of robot-assisted partial nephrectomy in elderly patients with localized renal cell carcinoma: an overlap-weighted Asian cohort study.

The value of robot-assisted partial nephrectomy (RAPN) in elderly Asian patients with localized renal cell carcinoma (RCC) remains insufficiently defined. We retrospectively analyzed 339 patients (&#x2265;&#x2009;70 years) with localized RCC treated at a single Asian center between 2015 and 2025, including 119 undergoing partial nephrectomy (PN) and 220 undergoing radical nephrectomy (RN). Propensity score overlap weighting (OW) was applied to compare PN versus RN and, within the PN cohort, RAPN versus laparoscopic partial nephrectomy (LPN). Three open partial nephrectomy cases were summarized descriptively and retained only in exploratory sensitivity analyses. Weighted logistic regression and Cox models with robust standard errors evaluated Clavien-Dindo grade&#x2009;&#x2265;&#x2009;II complications and overall survival (OS). After OW, PN was associated with better early postoperative renal functional preservation than RN but a greater incidence of grade&#x2009;&#x2265;&#x2009;II complications (36.4% vs. 17.6%; weighted p&#x2009;<&#x2009;0.001); OS was similar. Within the PN cohort, RAPN had longer operative time than LPN (weighted p&#x2009;=&#x2009;0.030), whereas warm ischemia time, early postoperative eGFR, and grade&#x2009;&#x2265;&#x2009;II complications (31.8% vs. 40.4%; weighted p&#x2009;=&#x2009;0.414) were not significantly different. Exploratory analyses favored RAPN, but only one death occurred in this group, and residual confounding remains possible. PN may preserve early renal function in selected older patients, while RAPN appears feasible in experienced centers; its survival association remains hypothesis-generating.

Humans

Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.

Robot-assisted guidance may improve the technical precision of percutaneous cannulated-screw fixation for femoral neck fractures. Whether these procedural advantages translate into better clinical outcomes remains uncertain. We compared robot-assisted and conventional freehand fixation in adults with femoral neck fractures. MEDLINE, Embase and CINAHL were searched from inception to 15 July 2026 without language restrictions. Google Scholar was used only as a supplementary search source, together with forward and backward citation searching. Comparative studies of robot-assisted versus freehand fluoroscopy-guided cannulated-screw fixation were included. Risk of bias was assessed using RoB 2 and ROBINS-I, with the Newcastle-Ottawa Scale used as a complementary appraisal of non-randomised studies. Random-effects meta-analyses included prediction intervals and prespecified sensitivity analyses. The protocol was registered prospectively (PROSPERO CRD420261465038). Sixteen comparative studies involving 1,293 participants were included. Of these, 597 underwent robot-assisted fixation and 696 underwent freehand fixation. Two studies reporting random allocation and 14 non-randomised studies were included in the study. Robot-assisted fixation was associated with fewer guide-wire manipulations, greater screw-placement accuracy and 13.9 fewer fluoroscopic acquisitions per procedure (95% confidence interval [CI] -20.3 to -7.5). Earlier radiographic healing and modestly higher final Harris Hip Scores were also observed. Pooled estimates suggested lower risks of union failure, avascular necrosis and composite complications. Fluoroscopy duration, overall operative time and reoperation did not differ significantly. Heterogeneity was substantial for several continuous outcomes, with prediction intervals crossing the null for several estimates, indicating that the magnitude of benefit varied considerably between studies. Some clinical associations were also sensitive to eligibility-restricted analyses. Robot-assisted cannulated-screw fixation improves technical execution compared with freehand fixation. Patient-important clinical superiority and economic value have not been established, and evidence concerning learning curves, operator acceptability and system reliability remains insufficient. Current evidence does not support routine widespread adoption; adequately powered multicentre randomised trials incorporating economic and implementation evaluation are required.

Humans

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

Real-time intraoperative perfusion assessment using indocianine green in pediatric extrinsic ureteropelvic junction obstruction with crossing vessel.

INTRODUCTION: In vascular hitch (VH) particular attention must be paid to preserving lower pole perfusion. Hypoperfusion is normally excluded by macroscopic visual assessment of parenchyma appearance. Our aim is to explore the possible role of indocyanine green (ICG) in highlighting focal hypoperfusion. MATERIALS AND METHODS: This prospective study included pediatric patients with UPJO caused by crossing vessels, treated with robot-assisted VH. Intraoperative evaluation assessed UPJ appearance, reduction of hydronephrosis after vessel mobilization, and the adequacy of pelvic drainage during diuretic testing. ICG was used to assess renal perfusion via NIRF imaging. A 25 mg ICG solution was prepared in 10 mL and administered in 1 mL doses. Fluorescence distribution, operative time, and complications were recorded. Follow-up at 3, 6, and 12 months included clinical evaluations, blood pressure measurements, and Doppler ultrasound. RESULTS: Eight patients (median age 8years) were enrolled between October 2023 and February 2025. ICG assessed renal perfusion post-procedure; one case of focal hypoperfusion due to vessel tension was resolved with intraoperative revision. At a median follow-up of 18 months, no hypertension, pain, or UTIs were observed. Ultrasound demonstrated improved hydronephrosis and normal Doppler flow. CONCLUSION: ICG angiography is a safe and effective tool for the real-time assessment of renal perfusion during pediatric VH procedures.

Humans

Minimally invasive versus open surgery for gallbladder cancer: A systematic review and meta-analysis.

INTRODUCTION: Minimally invasive surgery (MIS) is increasingly being used in gallbladder cancer (GBC) for radical tumour extirpation. However, there are conflicting results on the morbidity outcomes following MIS. The aim of this meta-analysis was to compare the post-operative morbidity and mortality in patients undergoing radical surgery for GBC between MIS and open surgery. MATERIAL AND METHODS: Studies comparing MIS (laparoscopic, robotic or both techniques) to open surgery were included. The databases of MEDLINE, Cochrane and EMBASE were searched from 2001 till March 2025. The primary end point was post-operative morbidity and mortality. The secondary end points were hospital stay, blood loss, operative time and R1 resection rates. Random effect models were used for analysis. The risk of bias was assessed using the Newcastle-Ottawa scale. RESULTS: Thirty-two studies (laparoscopic [n&#x202f;=&#x202f;19], robotic [n&#x202f;=&#x202f;6] or both [n&#x202f;=&#x202f;7]) involving 8568 (MIS&#x202f;=&#x202f;3287 and open&#x202f;=&#x202f;5281) patients were included. For overall and major morbidity (Clavian-Dindo >/&#x202f;=&#x202f;III), the odds ratio (OR) of 0.60 (95% CI: 0.46-0.78) and 0.72 (95% CI: 0.52-1.0) respectively was obtained, favouring the MIS approach. Similarly, MIS showed lower odds for mortality [OR:0.62 (95% CI: 0.40-0.95)] compared to open surgery. MIS was associated with shorter hospital stay (less by mean of 3 days) and lesser blood loss (less by mean of 115&#x202f;ml) but longer operative time (higher by mean of 5.8&#x202f;min) and higher R1 resection rates (OR: 1.34; 95% CI: 1.05-1.71). Oncological outcomes, however, were comparable. The certainty of evidence was very low to low across the studies. CONCLUSION: MIS for GBC was associated with relatively lower post operative morbidity and mortality with similar oncological outcomes but with a small but heightened risk of margin positive (R1) resection, especially in primary GBC. The certainty of evidence was very low to low across the included studies. Future prospective studies are needed to overcome the clinical heterogeneity and possible selection bias.

Humans

Comparison of clinical outcomes of robotic versus open pyeloplasty in infants under 6 months.

INTRODUCTION: Robotic pyeloplasties have become the popular approach for surgical repair of ureteropelvic junction obstruction (UPJO) in the pediatric population. In infants less than 6 months old, there is concern for lack of intra-abdominal working space and lack of benefit compared to an open approach. Our aim was to compare the peri-operative and post-operative outcomes of patients undergoing open versus robotic pyeloplasty under six months of age. METHODS: A retrospective review was performed of patients less than six months of age undergoing robotic or open pyeloplasty between 2020 and 2024 at a single institution. Patient demographics and clinical outcomes were collected and compared. Surgical success was defined as a >50% reduction in the antero-pelvic diameter (APD) of the affected kidney at one year post pyeloplasty. RESULTS: A total of 32 patients were identified (16 robotic and 16 open), median age at surgery was 4 months old. There was no significant difference in length of hospital stay or narcotic usage between the two groups. The robotic cohort had a significantly longer operative time (209.5 min vs 142.5 min, p < 0.001) compared to the open cohort. There was no significant difference between post-operative complication or surgical success rates between the two groups. CONCLUSION: In this small series, robotic and open pyeloplasty both remain viable options for infants less than 6 months of age with equivalent surgical outcomes and lengths of hospital stay.

Humans

Alignment strategies in total knee arthroplasty and the patellofemoral joint: A systematic review.

BACKGROUND: Different alignment strategies in total knee arthroplasty (TKA) may affect the patellofemoral joint. Mechanical alignment (MA) is commonly used but may alter native anatomy. Newer strategies such as kinematic alignment (KA), restricted kinematic alignment (rKA), and functional alignment (FA) aim to better restore native joint mechanics. This study provides an overview of the effects of alignment strategies on patellofemoral outcomes after TKA. METHODS: A literature search in July 2025 identified studies comparing patellofemoral outcomes in TKA using different alignment strategies. Of 166 studies screened, eight met inclusion criteria. Three studies were considered medium quality and five studies low quality. RESULTS: KA and rKA more closely restored native trochlear morphology than MA and FA, reducing outliers in the anterior trochlear line compared with MA and FA. MA showed greater trochlear translation, suggesting worse patellar tracking. Trochlear angles were more anatomical in KA and rKA. However, KA was associated with increased internal femoral component rotation and more outliers beyond safe thresholds. FA showed more consistent rotational positioning, generally within safe limits. Lateral patellar shift and intraoperative lateral release rates did not differ significantly between KA and MA. Only one study reported patella-specific clinical outcome scores, finding no difference between FA and adjusted MA. CONCLUSION: KA and rKA better restore trochlear morphology, but risk excessive internal femoral component rotation. FA provides a more balanced approach. MA, while widely used, is linked to altered trochlear shape and worse patellar tracking. The clinical impact of these radiological differences remains unclear, and higher-quality studies are needed.

Humans

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans