Search PubMedSearch

SEARCH · Search PubMed

Results for “Robot-assisted Biopsy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

188 records · Page 2Linked to original sources

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Alignment strategies in total knee arthroplasty and the patellofemoral joint: A systematic review.

BACKGROUND: Different alignment strategies in total knee arthroplasty (TKA) may affect the patellofemoral joint. Mechanical alignment (MA) is commonly used but may alter native anatomy. Newer strategies such as kinematic alignment (KA), restricted kinematic alignment (rKA), and functional alignment (FA) aim to better restore native joint mechanics. This study provides an overview of the effects of alignment strategies on patellofemoral outcomes after TKA. METHODS: A literature search in July 2025 identified studies comparing patellofemoral outcomes in TKA using different alignment strategies. Of 166 studies screened, eight met inclusion criteria. Three studies were considered medium quality and five studies low quality. RESULTS: KA and rKA more closely restored native trochlear morphology than MA and FA, reducing outliers in the anterior trochlear line compared with MA and FA. MA showed greater trochlear translation, suggesting worse patellar tracking. Trochlear angles were more anatomical in KA and rKA. However, KA was associated with increased internal femoral component rotation and more outliers beyond safe thresholds. FA showed more consistent rotational positioning, generally within safe limits. Lateral patellar shift and intraoperative lateral release rates did not differ significantly between KA and MA. Only one study reported patella-specific clinical outcome scores, finding no difference between FA and adjusted MA. CONCLUSION: KA and rKA better restore trochlear morphology, but risk excessive internal femoral component rotation. FA provides a more balanced approach. MA, while widely used, is linked to altered trochlear shape and worse patellar tracking. The clinical impact of these radiological differences remains unclear, and higher-quality studies are needed.

Humans

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Real-time intraoperative perfusion assessment using indocianine green in pediatric extrinsic ureteropelvic junction obstruction with crossing vessel.

INTRODUCTION: In vascular hitch (VH) particular attention must be paid to preserving lower pole perfusion. Hypoperfusion is normally excluded by macroscopic visual assessment of parenchyma appearance. Our aim is to explore the possible role of indocyanine green (ICG) in highlighting focal hypoperfusion. MATERIALS AND METHODS: This prospective study included pediatric patients with UPJO caused by crossing vessels, treated with robot-assisted VH. Intraoperative evaluation assessed UPJ appearance, reduction of hydronephrosis after vessel mobilization, and the adequacy of pelvic drainage during diuretic testing. ICG was used to assess renal perfusion via NIRF imaging. A 25 mg ICG solution was prepared in 10 mL and administered in 1 mL doses. Fluorescence distribution, operative time, and complications were recorded. Follow-up at 3, 6, and 12 months included clinical evaluations, blood pressure measurements, and Doppler ultrasound. RESULTS: Eight patients (median age 8years) were enrolled between October 2023 and February 2025. ICG assessed renal perfusion post-procedure; one case of focal hypoperfusion due to vessel tension was resolved with intraoperative revision. At a median follow-up of 18 months, no hypertension, pain, or UTIs were observed. Ultrasound demonstrated improved hydronephrosis and normal Doppler flow. CONCLUSION: ICG angiography is a safe and effective tool for the real-time assessment of renal perfusion during pediatric VH procedures.

Humans

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 &#xb1; 11.3&#xa0;years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield &#x2265;12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Humans

Positive Margin Rate Following Transoral Surgery in T2-T3 Laryngeal Carcinoma - a Systematic Review and Meta-Analysis.

BACKGROUND: Transoral endoscopic surgery, using either conventional laser techniques or supported by robotic assistance, represents an established treatment modality for selected patients with T2-T3 laryngeal carcinoma. The goal is complete tumor removal, as positive resection margins have been associated with worse oncological outcomes. This systematic review and meta-analysis aimed to determine the positive margin rate following transoral endoscopic surgery for T2-T3 laryngeal carcinoma and to evaluate its impact on oncologic outcomes. METHODS: A systematic search of Medline, Embase, Web of Science, Cochrane CENTRAL, and Google Scholar was performed from inception through March 2025, identifying studies reporting on surgical margin status after transoral resection of T2 and/or T3 laryngeal carcinoma. A random-effects meta-analysis of proportions was used to estimate a pooled positive margin rate. The oncologic impact of margin status is presented descriptively owing to data heterogeneity. RESULTS: Thirty-nine studies comprising 3,281 patients with T2-T3 laryngeal carcinoma met the inclusion criteria. The positive margin rate was 22.0% (95% CI 17.6 - 27.3, I2 = 83.8%) for the total T2-T3 cohort, with stratified rates of 22.4% for T2 and 30.8% for T3 tumors. Among the eight studies assessing the impact of positive margins in T2-T3 stages, three found a significant association with worse oncological outcomes. Conclusion A 22% positive margin rate was identified in T2-T3 laryngeal cancer treated with transoral endoscopic resection. However, the impact of margin status on oncological outcomes remains uncertain, largely due to challenges in sampling and histopathological assessment.

Humans

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Molecular Landscape and Advanced Diagnostic Technologies for BRAF Mutations in Cancer: From Quantitative PCR and ddPCR to CRISPR-Based Platforms.

BRAF mutations are key oncogenic alterations across multiple malignancies, including melanoma, thyroid carcinoma, colorectal cancer, non-small cell lung cancer, glioma, and hairy cell leukemia. The most prevalent variant, BRAF-V600E, induces constitutive activation of the MAPK signaling pathway, promoting tumor progression and influencing therapeutic responsiveness. Accurate detection of BRAF alterations is therefore essential for molecular classification, prognostic assessment, treatment selection, and resistance surveillance. This review summarizes the molecular heterogeneity of BRAF mutations and critically evaluates current diagnostic methodologies. Conventional approaches such as allele-specific PCR and Sanger sequencing are compared with advanced quantitative platforms, including high-resolution melting analysis, droplet digital PCR, and next-generation sequencing, with emphasis on analytical sensitivity, mutation coverage, and clinical applicability. Emerging technologies such as CRISPR-based assays, rolling circle amplification systems, and nanoparticle-based biosensors and point-of-care diagnostic platforms are also discussed for their potential to enhance ultra-sensitive detection, particularly in liquid biopsy settings. These emerging tools are highlighted for their potential to enable ultra-sensitive, rapid, and decentralized mutation detection, particularly in liquid biopsy settings. Key challenges, including intratumoral heterogeneity, low allele-frequency variants, FFPE-associated artifacts, and clonal evolution under therapeutic pressure, are examined within a translational framework. In addition, we examine critical barriers to clinical implementation, including standardization, cost, and global accessibility of molecular diagnostics, and outline potential solutions through scalable technologies and decentralized testing strategies. We propose that optimal BRAF testing requires a mutation subclass-informed and clinically integrated strategy combining comprehensive baseline profiling with longitudinal molecular monitoring. Future diagnostic paradigms will likely integrate multi-omics data and artificial intelligence (AI)-assisted interpretation to refine precision oncology implementation. Looking forward, we propose that optimal BRAF testing will require integration of multi-omics profiling with AI-assisted interpretation, enabling automated variant classification, real-time clinical decision support, and improved prediction of therapeutic response and resistance.

Humans

Robotic surgery for gastric gastrointestinal stromal tumors: a systematic review.

Robotic surgery is used for selected gastric gastrointestinal stromal tumours (GISTs), particularly when location makes conventional wedge resection difficult. We synthesised technical, perioperative, pathological, functional and oncological outcomes. PubMed/MEDLINE, Scopus and the Cochrane Library were searched from inception to 14 August 2026. Primary reports with at least three eligible robotic gastric-GIST patients were included. Two reviewers independently selected studies, extracted data and completed design-specific JBI appraisal. Because outcome definitions, denominators and reporting were heterogeneous, findings were synthesised narratively in accordance with SWiM guidance rather than pooled. Twenty-three studies, including six comparative cohorts, were included. Institutional robotic cohorts contained 3-45 eligible patients; one national registry included 1,567 robotic cases. Tumour size ranged from 2.68&#x2009;&#xb1;&#x2009;1.55 to 7.9&#x2009;&#xb1;&#x2009;1.8&#xa0;cm among studies reporting means. Most institutional reports described R0 resection in all eligible patients; exceptions were 23/24 and 24/25, while the registry reported 1,425/1,567 R0 resections. Grade III morbidity occurred in 2/25 patients in one function-preserving series. Registry 30- and 90-day mortality after robotic resection were 0.5% and 0.8%, respectively. Comparative studies did not demonstrate superior postoperative or oncological outcomes with robotic surgery. Robotic gastric-GIST resection appears feasible in selected patients and may facilitate organ-preserving surgery at anatomically challenging sites. Current observational evidence does not establish comparative functional, oncological or economic superiority.

Humans

Hybrid robotic transversus abdominis release (hrTAR) for complex ventral hernias: a systematic review and preliminary synthesis.

Hybrid robotic transversus abdominis release (hrTAR) combines robotic posterior component separation with a planned limited open phase. Evidence supporting this strategy is sparse. Following PRISMA 2020, we searched PubMed, Embase, Scopus, and the Cochrane Library and registered the protocol in PROSPERO (CRD420261303285). Eligible studies reported hrTAR outcomes for ventral or incisional hernia repair. Findings were synthesized narratively; no pooled effect estimates were calculated. Three reports contained 85 hrTAR cohort entries. Because two reports came from the same institution and overlap could not be excluded, this total should not be interpreted as a unique-patient count. Surgical-site outcomes were heterogeneous: two reports used SSO endpoints (4% and 5%), whereas another reported surgical-site events in 25% of patients, including seroma and wound infection. Mean length of stay ranged from 1.8 to 3.7 days; the sample-size-weighted mean across studies reporting means was 2.9 days. One propensity-matched comparison reported shorter hospitalization and lower 30-day SSO with hrTAR than open TAR. No perioperative deaths or recurrences were reported during limited follow-up. hrTAR appears feasible in selected patients, but available evidence is exploratory. Standardized prospective multicenter studies with non-overlapping cohorts and longer follow-up are needed before comparative effectiveness, economic value, or wider adoption can be supported.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Interhospital transfer and outcomes after robotic emergency general surgery: a national analysis.

The outcomes of patients transferred to receiving centers who subsequently undergo robotic EGS remain uncharacterized at a national level. We aimed to quantify the association between transfer and outcomes among adults undergoing robotic EGS. We performed a retrospective cohort study of the Nationwide Readmissions Database (2016-2019) including adult nonelective admissions undergoing robotic EGS. Interhospital transfer versus direct admission was the exposure. Survey-weighted logistic regression estimated adjusted odds ratios (aOR) for clinical outcomes; generalized linear models with gamma family and log link estimated adjusted mean ratios (aMR) for length of stay (LOS) and cost. Average marginal effects provided adjusted risks/means and absolute differences. Among 26,869 unweighted robotic EGS admissions, representing an estimated 46,517 admissions nationally, 246 unweighted admissions were interhospital transfers, representing an estimated 444 transfers (1.0%) nationally. Transfers were older, more comorbid, and more severely ill and were treated predominantly at large, teaching hospitals. After adjustment, transfer was associated with a higher risk of postprocedural complications (8.0% vs. 3.5%; aRR 2.26, 95% CI 1.25-3.27), non-home discharge (31.2% vs. 18.9%; aRR 1.65, 95% CI 1.38-1.92), longer LOS (11.49 vs. 5.53 days; AMR 2.08, 95% CI 1.78-2.42), and higher cost ($43,340 vs. $21,821; AMR 1.99, 95% CI 1.68-2.35). The association with postprocedural complications was attenuated after additional adjustment for APR-DRG Severity of Illness, whereas associations with non-home discharge, LOS, and cost persisted. Among patients undergoing robotic EGS, interhospital transfer is independently associated with higher complication burden and greater resource use. Transferred patients represent a small but distinctly high-risk subgroup whose worse outcomes may reflect drivers that extend beyond the choice of surgical approach.

Humans

Comparison of clinical outcomes of robotic versus open pyeloplasty in infants under 6 months.

INTRODUCTION: Robotic pyeloplasties have become the popular approach for surgical repair of ureteropelvic junction obstruction (UPJO) in the pediatric population. In infants less than 6 months old, there is concern for lack of intra-abdominal working space and lack of benefit compared to an open approach. Our aim was to compare the peri-operative and post-operative outcomes of patients undergoing open versus robotic pyeloplasty under six months of age. METHODS: A retrospective review was performed of patients less than six months of age undergoing robotic or open pyeloplasty between 2020 and 2024 at a single institution. Patient demographics and clinical outcomes were collected and compared. Surgical success was defined as a >50% reduction in the antero-pelvic diameter (APD) of the affected kidney at one year post pyeloplasty. RESULTS: A total of 32 patients were identified (16 robotic and 16 open), median age at surgery was 4 months old. There was no significant difference in length of hospital stay or narcotic usage between the two groups. The robotic cohort had a significantly longer operative time (209.5 min vs 142.5 min, p < 0.001) compared to the open cohort. There was no significant difference between post-operative complication or surgical success rates between the two groups. CONCLUSION: In this small series, robotic and open pyeloplasty both remain viable options for infants less than 6 months of age with equivalent surgical outcomes and lengths of hospital stay.

Humans

Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.

This systematic review and meta-analysis evaluated complication rates and diagnostic yield reported in studies of adult native kidney biopsy using 16-gauge (16&#x2009;G) or 18-gauge (18&#x2009;G) needles. We included randomized trials and cohort studies of real-time ultrasound-guided biopsies, including case series. MEDLINE, Embase, and CENTRAL were searched through October 2024. Two reviewers independently performed study selection, data extraction, and risk of bias assessment using Joanna Briggs Institute tools. Random-effects meta-analyses estimated pooled proportions with 95% confidence intervals (CI), and univariable random-effects meta-regression explored study-level associations with major complications, transfusion, or gross hematuria. We screened 4,499 titles and abstracts and reviewed 319 full-text articles; 62 studies comprising 68 biopsy series were included. The pooled major complication rate in studies using 16&#x2009;G needles was 1.83% (95% CI: 1.20-2.79) and 1.29% (95% CI: 0.78-2.13) in studies using 18&#x2009;G needles, with no statistically significant difference. Mean glomerular yield was 18.8 with 16&#x2009;G and 17.5 with 18&#x2009;G needles. In study-level meta-regression, studies with higher prevalence of acute kidney injury, lower mean estimated glomerular filtration rate, or lower mean hemoglobin reported higher pooled complication rates. Most studies were single-arm cohorts; between-needle differences therefore reflect indirect study-level contrasts. Interpretation is limited by retrospective design and heterogeneity across studies. Overall, studies using both needle sizes reported low complication rates and similar diagnostic yield, although definitions and reporting varied. Direct comparative studies are needed to determine whether meaningful differences exist.

Humans

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

Use of indocyanine green fluorescence versus patent blue V dye for sentinel lymph node biopsy in early breast cancer, a randomized controlled trial.

BACKGROUND: Sentinel lymph node biopsy (SLNB) is standard for axillary staging in early breast cancer. While the combination of radioisotope and blue dye (e.g., patent blue V, PBV) remains the standard, it has limitations including logistics, variable identification rate (IR), and allergic potential. Indocyanine green (ICG) fluorescence is a promising alternative, but high-quality comparative evidence is needed. METHODS: This was a single-center, prospective, randomized controlled trial. Forty patients with early-stage, node-negative breast cancer were allocated to SLNB using either ICG (n&#x2009;=&#x2009;20) or PBV (n&#x2009;=&#x2009;20). All patients subsequently underwent completion level I-II axillary lymph node dissection (ALND) as the pathological reference standard for diagnostic performance assessment. Primary outcome was sentinel lymph node (SLN) IR. Secondary outcomes included detection time, number of SLNs retrieved, false-negative rate (FNR), and safety. RESULTS: Baseline characteristics were comparable between groups. The SLN IR was significantly higher with ICG (100% [20/20]) than with PBV (75% [15/20], p&#x2009;=&#x2009;0.047). ICG was associated with a significantly shorter median detection time (14.5 vs. 24.0&#xa0;min, p&#x2009;<&#x2009;0.001) and retrieved more SLNs (mean: 3.6 vs. 2.4, p&#x2009;=&#x2009;0.002). Most critically, ICG demonstrated 100% sensitivity, specificity, negative predictive value (NPV), and overall diagnostic accuracy, with a 0% FNR. In contrast, PBV achieved a sensitivity of 75%, an overall diagnostic accuracy of 90%, and an FNR of 25%. No ICG-related adverse events occurred. PBV caused skin discoloration in 75% of patients and one (5%) allergic reaction. CONCLUSION: ICG fluorescence achieved a higher SLN IR, shorter detection time, higher sensitivity, lower FNR, and fewer tracer-related adverse events than PBV as a single tracer for SLNB in patients with early-stage breast cancer. These findings suggest that ICG is a promising standalone tracer when radioisotope mapping is unavailable. Larger multicenter studies are required before widespread adoption can be recommended.

Humans

Integrated morphologic, immunophenotypic, and molecular profiling of advanced upper tract urothelial carcinoma across tumor compartments supports biopsy-based testing.

Upper tract urothelial carcinoma (UTUC) is an aggressive malignancy with limited molecular characterization in advanced disease. FGFR3 alterations are well established in low-grade urothelial carcinoma, but their prevalence, stability, and biological significance in locally advanced and metastatic UTUC remain only partially defined. We performed an integrated morphologic, immunohistochemical, and molecular analysis of 24 locally advanced and/or metastatic UTUC from 20 patients. FGFR3 status was assessed by RT-PCR across multiple tumor compartments, including biopsies, primary tumors, lymph-node metastases, and distant metastatic sites. Immunohistochemistry included CK20, CK5, GATA3, p53, and mismatch repair proteins. Targeted next-generation sequencing (NGS) was used to characterize co-occurring genomic alterations and to assess concordance with p53 immunophenotype. FGFR3 alterations were identified in 50% of patients and in 54.2% of analyzed tumors. FGFR3 status showed high intra-patient stability, with concordance between primary tumors and distant metastases in 90% of cases, whereas concordance with lymph node metastases was lower (50%), suggesting site-specific clonal divergence. Despite advanced stage, 92.3% of FGFR3-altered tumors displayed papillary urothelial carcinoma morphology, and most showed a luminal immunophenotype (61.5% by CK20/CK5 and 69.2% by GATA3/CK5). Targeted NGS revealed additional pathogenic alterations in 75% of patients, most frequently involving RTK/RAS/MAPK signaling (70%), cell-cycle regulation (25%), and PI3K/AKT pathway components (10%). TP53 mutations co-occurred with FGFR3 alterations in 60% of FGFR3-mutated patients and showed 90.4% concordance with p53 immunohistochemistry. Finally, a few cases exhibited complex, multi-site FGFR3 mutational patterns, consistent with intratumoral clonal evolutions. In conclusion, FGFR3 alterations are frequent and remarkably stable in advanced UTUC, even in high-grade and metastatic disease. These findings support the reliability of FGFR3 testing on limited diagnostic material and reinforce its relevance for therapeutic stratification. UTUC emerges as a molecularly dynamic disease in which early oncogenic drivers such as FGFR3 continue to shape tumor biology and therapeutic vulnerability at advanced stages.

Humans

Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.

INTRODUCTION: Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited. METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models. RESULTS: Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR&#x207b;] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2&#x2009;=&#x2009;69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions&#x2009;>&#x2009;30&#xa0;mm (RR 1.14, 95% CI 1.02-1.28, I2&#x2009;=&#x2009;81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57). CONCLUSION: The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable. TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Humans