Search PubMedSearch

PubMed · 42711700

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

Abstract

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Explore related subjects

Keep this discovery

BibTeXRIS

Cagla Kettner, Melina Beyerlein, Charlotte Marquardt, Miha De&#x17e;man, Tamim Asfour, Thorsten Stein. 2026-09-08. Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.. https://doi.org/10.1186/s12984-026-02151-y

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans