Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.

Abstract

This systematic review and meta-analysis evaluated complication rates and diagnostic yield reported in studies of adult native kidney biopsy using 16-gauge (16 G) or 18-gauge (18 G) needles. We included randomized trials and cohort studies of real-time ultrasound-guided biopsies, including case series. MEDLINE, Embase, and CENTRAL were searched through October 2024. Two reviewers independently performed study selection, data extraction, and risk of bias assessment using Joanna Briggs Institute tools. Random-effects meta-analyses estimated pooled proportions with 95% confidence intervals (CI), and univariable random-effects meta-regression explored study-level associations with major complications, transfusion, or gross hematuria. We screened 4,499 titles and abstracts and reviewed 319 full-text articles; 62 studies comprising 68 biopsy series were included. The pooled major complication rate in studies using 16 G needles was 1.83% (95% CI: 1.20-2.79) and 1.29% (95% CI: 0.78-2.13) in studies using 18 G needles, with no statistically significant difference. Mean glomerular yield was 18.8 with 16 G and 17.5 with 18 G needles. In study-level meta-regression, studies with higher prevalence of acute kidney injury, lower mean estimated glomerular filtration rate, or lower mean hemoglobin reported higher pooled complication rates. Most studies were single-arm cohorts; between-needle differences therefore reflect indirect study-level contrasts. Interpretation is limited by retrospective design and heterogeneity across studies. Overall, studies using both needle sizes reported low complication rates and similar diagnostic yield, although definitions and reporting varied. Direct comparative studies are needed to determine whether meaningful differences exist.

Explore related subjects

Keep this discovery

BibTeXRIS

Marie Møller, Tue H Andersen, Rikke Borg, Robin Christensen, Iain Bressendorff, Emilie K Hansen, Rasmus Rønnemoes, Signe K Jakobsen, Karina Haar, Frederik Persson, Peter Rossing, Ditte Hansen. 2026-05-25. Complication rates of 16- and 18-gauge needles for native kidney biopsies: a systematic review and proportional meta-analysis.. https://doi.org/10.1080/0886022x.2026.2665032

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Risk factors and management strategies for needle disengagement from the visual field in pediatric robot-assisted laparoscopic pyeloplasty.

OBJECTIVE: This study aimed to identify risk factors for suture needle disengagement from the visual field during pediatric robot-assisted laparoscopic pyeloplasty (RALP) and propose effective strategies for prevention and management. METHODS: A retrospective cohort study analyzed clinical data from 339 pediatric patients who underwent RALP for ureteropelvic junction obstruction (UPJO) at a single institution between August 2017 and December 2020. Patients were categorized based on the occurrence of needle disengagement from the visual field. Various patient demographics and surgical procedural factors were evaluated. Univariate and multivariate logistic regression, along with LASSO regression, identified independent risk and protective factors. RESULTS: Needle disengagement occurred in 38 (11.21%) of 339 cases. Multivariate logistic regression identified five independent risk factors for needle disengagement: use of a 3-mm auxiliary trocar (OR = 4.69, 95% CI: 1.98-12.53, P < 0.001), non-standard needle holder use (OR = 2.32, 95% CI: 1.04-5.18, P = 0.038), unshaped suture needles (OR = 3.16, 95% CI: 1.44-7.19, P = 0.005), simultaneous use of &#x2265;2 intra-abdominal sutures (OR = 2.46, 95% CI: 1.15-5.48, P = 0.023), and clamping the needle shank during withdrawal (OR = 3.42, 95% CI: 1.40-8.21, P = 0.006). Conversely, sufficient assistant experience (>10 cases) was identified as a protective factor (OR = 0.39, 95% CI: 0.18-0.88, P = 0.021). CONCLUSION: Suture needle disengagement from the visual field during pediatric RALP is associated with specific technical and instrumental factors. Implementing targeted strategies-such as mandating specialized needle holders, preoperative needle shaping, a single-needle workflow, prioritizing clamping the suture thread over the needle shank during withdrawal, and ensuring adequate assistant training-has the potential to significantly reduce significantly mitigate the risk of needle loss and enhance overall surgical safety in pediatric RALP.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.

INTRODUCTION: Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited. METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models. RESULTS: Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR&#x207b;] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2&#x2009;=&#x2009;69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions&#x2009;>&#x2009;30&#xa0;mm (RR 1.14, 95% CI 1.02-1.28, I2&#x2009;=&#x2009;81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57). CONCLUSION: The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable. TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Humans