INTRODUCTION: Accurate tissue acquisition (TA) of solid pancreatic lesions is essential for guiding treatment with endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) being the preferred method. Among FNB designs, the three-pronged Franseen-tip needle demonstrates strong diagnostic performance, though direct head-to-head comparisons with other FNB designs remain limited. METHODOLOGY: This meta-analysis was conducted in accordance with PRISMA guidelines (PROSPERO: CRD420251123856). Eligible studies enrolled patients with solid pancreatic lesions who underwent EUS-guided FNB, directly compared the Franseen-tip with other FNB needles. Six databases were systematically searched through July 2025, and study selection, data extraction, and risk of bias assessment (QUADAS-2 tool) were performed independently by two reviewers. Pooled estimates were generated using random-effects and bivariate hierarchical models. RESULTS: Sixteen studies (2,010 Franseen vs. 2,811 comparator) were included. Bivariate analysis showed that sensitivity and specificity of the Franseen needle were comparable to newer-generation comparator needles (sensitivity 91.3% vs. 94.0%; specificity 99.99% vs. 99.15%), whereas older-generation needles demonstrated lower sensitivity (80.8%) and inferior discriminatory performance (Negative Likelihood Ratio [LR⁻] 0.19 vs. 0.09). Diagnostic accuracy was higher with the Franseen needle (RR 1.07, 95% CI 1.01-1.14; I2 = 69%). Sample adequacy was similar overall (RR 1.04, 95% CI 0.95-1.14) but superior to older-generation needles (RR 1.19, 95% CI 1.02-1.41) and in lesions > 30 mm (RR 1.14, 95% CI 1.02-1.28, I2 = 81.2%). The Franseen needle achieved nominally strong diagnostic performance (DOR 116.6), although small-study effects were observed. Primary procedural outcomes were comparable between Franseen and comparator needles, including technical success (RR 1.00, 95% CI 0.98-1.02) and histological core procurement (RR 1.04, 95% CI 0.92-1.17). The Franseen needle had fewer low-cellularity samples (RR 0.56, 95% CI 0.45-0.69) and lower specimen bloodiness (RR 0.48, 95% CI 0.25-0.90) but a slightly higher overall adverse event rate (RR 1.29, 95% CI 1.06-1.57). CONCLUSION: The Franseen needle provides superior diagnostic accuracy and sample adequacy compared to older-generation FNB needles with comparable performance to newer-generation designs. It reduces low-cellularity samples and specimen bloodiness, although adverse events are slightly increased, with other primary procedural outcomes remaining comparable. TRIAL REGISTRATION: PROSPERO (Registration No. CRD420251123856).

Explore related subjects

Keep this discovery

BibTeXRIS

Adnan Bhat, Muhammad Arham, Zahra Ali, Saniya Ishtiaq, Muhammad Abdul Rehman, Adil Ahmed, Anchit Chauhan, Haseeb Khan Tareen, Kinza Bakht, Faseeh Haider, Allah Dad, Lindsey Creech, Aleksey Novikov, Peter V Draganov. 2026-05-19. Endoscopic Ultrasound-Guided Franseen Fine-Needle Biopsy for Solid Pancreatic Lesions: A Systematic Review and Meta-Analysis.. https://doi.org/10.1007/s10620-026-09970-y

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Primary pulmonary salivary gland-type tumors in cytopathology practice: A systematic review and meta-analysis.

BACKGROUND: Primary pulmonary salivary gland-type tumors (PSGTs) are rare but clinically significant tumors that originate from the submucosal glands of the tracheobronchial tree. Cytologic samples taken during bronchoscopy are a key component of preoperative evaluation. However, cytologic diagnosis remains challenging because of the submucosal growth and morphologic overlap of PSGTs. In addition, current knowledge of the cytohistologic correlation of PSGTs is fragmented. The objective of this study was to assess the effectiveness of cytologic diagnoses of PSGTs. METHODS: A comprehensive, systematic literature search of the PubMed database was conducted to identify studies with cytologic and histologic diagnoses of PSGTs. Comprehensive data on diagnostic and clinical factors, when available, were collected for all individual patients. The data were tabulated in Microsoft Excel and analyzed using OpenMeta (Analyst) software. RESULTS: In total, 49 studies comprising 106 patients were identified. Final cytohistologic concordance was demonstrated in 48.1% of cases. Fine-needle aspiration showed the highest sensitivity (75.0%), followed by bronchial/tracheal washing (38.1%), and bronchial brushing (34.2%). Adenoid cystic carcinoma was the most common histologic subtype, accounting for 67 cases, followed by mucoepidermoid carcinoma, which accounted for 27 cases. CONCLUSIONS: The cytologic diagnosis of rare PSGTs remains challenging. Overall, cytohistologic concordance was 48.1%. However, fine-needle aspiration demonstrated greater diagnostic accuracy than exfoliative cytology and may facilitate a more accurate preoperative assessment.

Humans

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n  = 627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans

Efficacy and safety of endoscopic ultrasound-guided choledochoduodenostomy compared with endoscopic ultrasound-guided gallbladder drainage for palliation of malignant distal biliary obstruction: a systematic review and meta-analysis.

BACKGROUND AND AIMS: When ERCP is not feasible or fails in the palliation of malignant distal biliary obstruction (MDBO), EUS-guided choledochoduodenostomy (EUS-CDS) and EUS-guided gallbladder drainage (EUS-GBD) are viable alternatives. We conducted a systematic review and meta-analysis comparing the safety and efficacy of the 2 techniques for the palliation of MDBO. METHODS: Multiple databases were searched through November 2025 for studies that reported outcomes of EUS-CDS and EUS-GDB in patients with MDBO. A meta-analysis was performed to determine pooled proportions and relative risk (RR) with 95% CIs. We compared the rates of technical and clinical success, overall adverse events (AEs), and lumen-apposing metal stent dysfunction. A random-effects model was used for our meta-analysis, and heterogeneity was assessed using the I2 (%) statistics. RESULTS: Five studies (352 patients; EUS-CDS: 193 and EUS-GBD: 159) were included. Technical success was 93.3% (95% CI, 70.6-98.8) for EUS-CDS and 95.9% (95% CI, 90.0-98.4) for EUS-GBD (RR, 1.02; 95% CI, 0.94-1.10; P = .6). Clinical success was 90.1% (95% CI, 84.7-93.7) versus 86.6% (95% CI, 80.3-91.0) (RR, 0.97; 95% CI, 0.90-1.05; P = .4). There were no significant differences in overall AEs (19.7% vs 17.6%; RR, 0.93; 95% CI, 0.58-1.48; P = .8), severe AEs (11.0% vs 8.3%; RR, 0.69; 95% CI, 0.33-1.44; P = .3), or stent dysfunction (15.0% vs 14.5%; RR, 0.95; 95% CI, 0.35-2.58; P = .9). CONCLUSIONS: EUS-GBD appears comparable to EUS-CDS in terms of technical and clinical success, AEs, and stent dysfunction. Further prospective studies are warranted to corroborate our findings.

Humans