Search PubMedSearch

SEARCH · Search PubMed

Results for “Male”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Cross-kingdom dynamics of the subgingival bacteriome and mycobiome: A pilot study on the effects of a novel HA-H&#x2082;O&#x2082;-Glycine formulation to treat periodontitis.

OBJECTIVES: Traditional periodontal therapy primarily focuses on bacterial biofilm control; however, recent evidence also suggests a critical role for the oral mycobiome. This study evaluated the clinical and ecological impact of a novel mouthwash formulation containing hyaluronic acid (HA), hydrogen peroxide (H2O2), and glycine on periodontal patients METHODS: This prospective, randomized split-mouth trial included 13 adult participants with periodontitis treated with HA-H2O2-glycine formula (BMG0703A) used twice a day for seven days. Subgingival plaque samples were collected from periodontal pocket and healthy control sites at baseline (T0) and one-week post-treatment (T1). Microbial and fungal communities were characterized using Next-Generation Sequencing (NGS) of the 16S rRNA and ITS2 regions. Linear Mixed Models (LMM) and Spearman correlation were used to assess taxonomic shifts and cross-kingdom relationships. RESULTS: Sequencing revealed a promising ecological shift: the bacteriome shifted from anaerobic dominance (Olsenella, Peptostreptococcus) toward a health-associated aerobic profile, with Rothia near-doubling (11.91% to 22.68%). The mycobiome underwent a "normalization" effect: Candida abundance decreased significantly (22.8% to 9.1%), while fungal Shannon diversity in pockets returned to healthy-site levels. Inter-kingdom analysis identified antagonistic relationships between expanding commensal bacteria and opportunistic fungi, suggesting that the intervention may help re-establish a protective bacterial niche. CONCLUSIONS: The HA-H2O2-glycine formulation seems to facilitate a rapid, cross-kingdom modulation of the subgingival niche. By reducing anaerobic pathogens and normalizing the mycobiome it appear to induce short-term changes, suggesting potential as adjunctive strategy in periodontal management. CLINICAL SIGNIFICANCE: The present work underlines the possible cross-Kingdom effects of a novel compound.

Humans

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans

Effects of semaglutide and empagliflozin on markers of endothelial function in persons with type 2 diabetes: A post hoc analysis of a randomized clinical trial.

AIMS: The endothelium maintains vascular health by regulating blood flow and protecting against inflammatory damage. In type 2 diabetes (T2DM), however, hyperglycemia, hypertension, and hyperlipidemia place a significant burden on the endothelium, potentially leading to atherosclerosis and cardiovascular disease (CVD). While semaglutide and empagliflozin have been shown to reduce CVD risk in T2DM, it remains unclear whether these benefits are mediated by improved endothelial function. This post-hoc analysis explores the effects of these agents on markers of endothelial function, i.e. the reactive hyperaemic index (RHI) and the endothelial-derived cell adhesion molecules (CAMs) E-Selectin, ICAM-1, P-Selectin, and VCAM-1. METHODS: This was a post-hoc analysis of a 32-week randomized trial evaluating the separate and combined effects of semaglutide and empagliflozin on cardio-renal organ damage. One hundred and twenty participants with type 2 diabetes, age&#xa0;&#x2265;&#xa0;50 were randomized to four groups (semaglutide, empagliflozin, the combination or placebo). An increase in RHI and/or a decrease in CAMs were considered beneficial. RESULTS: RHI increased compared to baseline (0.11, 95%CI [0.008;0.21], p&#xa0;=&#xa0;0.03) but not compared to placebo in the semaglutide group (0.11, 95%CI [-0.04;0.24], p&#xa0;=&#xa0;0.16). There was no effect on RHI in the empagliflozin group. Compared to placebo, E-Selectin decreased significantly in the semaglutide and combination groups (-9, 95%CI [-14.1;-5.1] p&#xa0;<&#xa0;0.01 and&#xa0;-&#xa0;9, 95%CI [-14.3; -5.2] p&#xa0;<&#xa0;0.01, respectively). VCAM-1 increased in the same groups, compared to placebo (12.3, 95%CI[2.8;20.8] p&#xa0;=&#xa0;0.01 and 16.2, 95%CI [7.2;24.3], p&#xa0;<&#xa0;0.01, respectively).P-Selectin and ICAM-1 was not significantly affected in any of the groups, compared to placebo (p&#xa0;&#x2265;&#xa0;0.11 and p&#xa0;&#x2265;&#xa0;0.09, respectively). CONCLUSION: Semaglutide improved endothelial function compared to baseline, but not significantly versus placebo, which likely is due to limited power. CAM responses were heterogeneous, suggesting distinct roles in endothelial dysfunction and atherosclerosis. ClinicalTrialsRegister.eu: EudraCT 2019-000781-38.

Aged

Systematic multi-domain screening of lead-specific electrocardiographic features associated with sudden cardiac death.

UNLABELLED: Electrocardiogram (ECG) provides four-dimensional view to the electrical properties of the heart. We performed a comprehensive multi-domain screening to find the most significant lead-specific ECG features associated with sudden cardiac death (SCD). METHODS: We analyzed retrospective data from 21,176 consecutive patients undergoing coronary angiography in Tampere University Hospital between 2007 and 2018. 937 ECG variables provided by the 12SL algorithm were used for the analysis. From those, the significant lead-specific ECG variables were categorized into three subgroups: P-wave, QRS complex, and ST-segment/T-wave. The most significant (i.e., lowest P-value) independent lead-specific ECG variables were tested in multivariate analysis after filtering correlating variables with weaker associations with SCD. RESULTS: Among ventricular depolarization (QRS complex) variables, the strongest associations with SCD were observed for QRS intrinsicoid deflection (lead I) (p&#xa0;=&#xa0;4.6&#xa0;&#xd7;&#xa0;10-8), QRS peak-to-peak amplitude (lead aVR) (p&#xa0;=&#xa0;1.9&#xa0;&#xd7;&#xa0;10-5), and Q-wave amplitude (lead V1) (p&#xa0;=&#xa0;7.6&#xa0;&#xd7;&#xa0;10-6). Among repolarization (ST-segment and T-wave) variables, the strongest predictors of SCD were T-wave amplitude (lead aVR) (p&#xa0;=&#xa0;3.5&#xa0;&#xd7;&#xa0;10-7) and ST-segment end amplitude (lead aVL) (p&#xa0;=&#xa0;8.1&#xa0;&#xd7;&#xa0;10-5). The strongest associations with SCD among atrial depolarization (P-wave) variables were P-wave onset amplitude (lead V6) (p&#xa0;=&#xa0;3.1&#xa0;&#xd7;&#xa0;10-6), P'-wave amplitude (lead V2) (p&#xa0;=&#xa0;2.1&#xa0;&#xd7;&#xa0;10-5), and P-wave duration (lead V2) (p&#xa0;=&#xa0;2.4&#xa0;&#xd7;&#xa0;10-3). These variables remained significant in multivariate analysis alongside global ECG variables (e.g., heart rate, QRS duration, and LVH). CONCLUSION: Systematic screening and utilizing the full prognostic potential of the 12&#x2011;lead ECG reveal several key elements of the electrical properties of the heart that associate with SCD.

Humans

Prognostic value of early changes in the frontal QRS-T angle in patients with heart failure and left bundle branch block undergoing cardiac resynchronization therapy.

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in selected patients with heart failure (HF). The frontal QRS-T angle (FQTA), reflecting ventricular depolarization-repolarization heterogeneity, has been associated with major adverse cardiovascular events (MACE). We aimed to assess the prognostic value of changes in the FQTA after CRT in predicting long-term MACE. METHODS: A total of 223 consecutive HF patients with left bundle branch block who underwent CRT between 2018 and 2022 were retrospectively analyzed. The FQTA was measured before and after CRT, and the change (&#x394;FQTA) was calculated. Receiver operating characteristic (ROC) analysis was performed to determine the optimal cutoff value for predicting the primary outcome, MACE. Patients were subsequently stratified according to this cutoff value. Independent predictors were identified using multivariable Cox proportional hazards regression analysis. RESULTS: ROC analysis identified 22.5&#xb0; as the optimal cutoff value for predicting MACE (AUC: 0.711; 95% CI: 0.642-0.781; p&#xa0;<&#xa0;0.001). During a mean follow-up of 34.6&#xa0;&#xb1;&#xa0;17.6&#xa0;months, patients with &#x394;FQTA <22.5&#xb0; had a significantly higher incidence of MACE compared with those with greater angle reduction (44.7% vs. 11.9%; p&#xa0;<&#xa0;0.001). In multivariable Cox regression analysis, chronic kidney disease (HR: 2.517; p&#xa0;=&#xa0;0.002) and &#x394;FQTA <22.5&#xb0; (HR: 4.56; p&#xa0;<&#xa0;0.001) were independently associated with MACE. CONCLUSION: A greater reduction in FQTA after CRT is associated with improved long-term outcomes and may serve as a practical electrocardiographic marker for risk stratification.

Humans

Feasibility and efficacy of left bundle branch area pacing guided by modified chest lead 1.

BACKGROUND: Left bundle branch area pacing (LBBAP) typically requires 12&#x2011;lead electrocardiogram (ECG) measurements using an electrophysiology (EP) recording system. However, a simplified approach using modified chest lead 1 (MCL1) is potentially feasible. This study aimed to compare the success rate and pacing outcomes of LBBAP guided by MCL1 with those guided by the 12&#x2011;lead ECG using an EP recording system. METHODS: This retrospective, single-center study included patients with preserved left ventricular ejection fraction who underwent LBBAP for bradyarrhythmia. LBBAP was either guided by 12&#x2011;lead ECG using an EP recording system or by MCL1. In the MCL1 group, a follow-up examination with a 12&#x2011;lead ECG using an EP recording system was conducted within one week postoperatively. RESULTS: A total of 65 patients underwent LBBAP (EP recording system group: n&#xa0;=&#xa0;35; MCL1 group: n&#xa0;=&#xa0;30). The overall success rate of LBBAP was 84.6%, with no significant difference between groups (88.5% vs. 80.0%, p&#xa0;=&#xa0;0.49). No significant differences were observed in the paced QRS duration (140.4&#xa0;&#xb1;&#xa0;8.0 vs. 141.9&#xa0;&#xb1;&#xa0;13.1&#xa0;ms, p&#xa0;=&#xa0;0.54), V6-V1 interpeak interval (39.7&#xa0;&#xb1;&#xa0;16.5 vs. 38.3&#xa0;&#xb1;&#xa0;15.6&#xa0;ms, p&#xa0;=&#xa0;0.79), or V6 R-wave peak time (69.8&#xa0;&#xb1;&#xa0;12.3 vs. 71.5&#xa0;&#xb1;&#xa0;12.1&#xa0;ms, p&#xa0;=&#xa0;0.68). CONCLUSIONS: MCL1-guided LBBAP was feasible and achieved a high success rate, with outcomes comparable to those of conventional EP recording system-guided implantation. This simplified approach may reduce procedural complexity and may allow LBBAP implantation without the routine use of an EP recording system.

Humans

Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.

BACKGROUND: The electrocardiogram (ECG) is widely used to infer infarct location and extent in anterior myocardial infarction (MI), based on either anatomical lead proximity or vectorial orientation of ST-segment deviation. However, the validity of these approaches against direct imaging of myocardial injury remains uncertain. METHODS: In this prospective study, 105 patients with anterior MI underwent cardiac magnetic resonance (CMR) imaging 3-7&#xa0;days after presentation. Admission ECGs were analyzed using (1) conventional ECG localization categories, and (2) simplified frontal and horizontal ST-axis orientation. CMR-defined injury distribution was assessed using late gadolinium enhancement and myocardial edema imaging. RESULTS: Conventional ECG localization categories demonstrated no significant association with CMR-defined infarct distribution (P&#xa0;=&#xa0;0.24), with poor agreement (&#x3ba;&#xa0;=&#xa0;0.122) and substantial overlap across categories. Simplified ST-axis orientation showed modest and inconsistent associations with infarct location and did not meaningfully explain infarct size. In contrast, global ST-segment burden was associated with CMR-defined infarct size (&#x3a3;STE: standardized &#x3b2;&#xa0;=&#xa0;0.307, P&#xa0;=&#xa0;0.002; lead count: standardized &#x3b2;&#xa0;=&#xa0;0.267, P&#xa0;=&#xa0;0.007). CONCLUSIONS: In this selected cohort of reperfused LAD-related anterior STEMI patients undergoing early CMR, conventional ECG localization categories and simplified ST-axis orientation showed poor or inconsistent correspondence with CMR-defined infarct distribution, whereas global ST-segment burden showed a modest association with infarct size. These findings suggest that, in this cohort, the ECG may be better suited to reflect the extent of myocardial injury rather than its precise anatomical location.

Humans

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Electrocardiographic correlates of pacing induced cardiomyopathy and response to cardiac resynchronization therapy.

BACKGROUND: Chronic right ventricular (RV) pacing (RVP) causes pacing-induced cardiomyopathy (PICM) in only a small number of patients. We evaluated ECG correlates of (i) PICM and (ii) response to cardiac resynchronization therapy (CRT) upgrade. METHODS: We conducted a retrospective case-control study by including all CRT upgrades for PICM (LVEF <50%) at our center between 2014 and 2018. Controls were patients with &#x2265;5 ECGs all demonstrating RVP over &#x2265;2&#xa0;years and all echocardiographic LVEF &#x2265;50%. Root-summed-squared (3D) ECG was obtained from reconstructed vectorcardiographic X-Y-Z leads. Predictors of PICM and CRT response were assessed as area under ROC curve (AUC) for pre-CRT and &#x394; (post-CRT - pre-CRT) ECG intervals and QRS voltage-time-integrals (VTI). RESULTS: We included 104 patients with CRT upgrade for PICM (age 73.7&#xa0;&#xb1;&#xa0;10.5&#xa0;years, female 29.1%, QRS duration 167.8&#xa0;&#xb1;&#xa0;25.2&#xa0;ms, LVEF 28.8&#xa0;&#xb1;&#xa0;8.0%, &#x394;LVEF 13.8&#xa0;&#xb1;&#xa0;10.3%) and 178 controls without PICM (age 73.2&#xa0;&#xb1;&#xa0;14.9&#xa0;years, female 52.8%, QRS duration 144.0&#xa0;&#xb1;&#xa0;20.9&#xa0;ms, LVEF 56.7&#xa0;&#xb1;&#xa0;5.2%). PICM was best identified by VTIQRS-3D (AUC 0.851; VTIQRS-3D&#xa0;&#x2265;&#xa0;80 &#x3bc;Vs sensitivity 87.5%, specificity 63.5%), VTIQRS-Y (0.846), and QRS duration (0.775). CRT response (LVEF increase &#x2265;10% at 3-12&#xa0;months) occurred in 73/104 (70.2%) patients. Lack of CRT response was best predicted by longer pre-CRT QRS duration (AUC 0.640; QRS duration &#x2265;180&#xa0;ms sensitivity 45.2%, specificity 83.6%), and less &#x394;VTIQRS-3D (0.609) and &#x394;VTIQRS-X (0.608). CONCLUSION: In patients with chronic RVP, VTIQRS-3D&#xa0;&#x2265;&#xa0;80 &#x3bc;Vs can be used as a screening test for echocardiographic confirmation of PICM. RV-paced QRS duration >180&#xa0;ms, on the other hand, identifies those who may not respond to CRT upgrade.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Ultra-high-frequency ECG quantifies residual electrical dyssynchrony during left bundle branch area pacing in patients with wide QRS: a paired within-patient study.

BACKGROUND: Left bundle branch area pacing (LBBAP) may restore a more physiological pattern of ventricular activation in patients with conduction delay; however, QRS narrowing alone may incompletely characterize electrical resynchronization. Ultra-high-frequency ECG (UHF-ECG) provides quantitative markers of ventricular activation timing and dyssynchrony. OBJECTIVE: To quantify paired OFF-to-ON changes in conventional ECG and UHF-ECG metrics during LBBAP in patients with baseline wide QRS and to assess the relationship between paced R-wave peak time (RWPT) and residual UHF-ECG dyssynchrony. METHODS: In this prospective single-center paired study, 21 patients with bradycardia and baseline wide QRS underwent standard ECG and UHF-ECG assessment during intrinsic rhythm (pacing OFF) and during LBBAP (pacing ON). Endpoints included QRS duration, signed VED16, absolute VED16 (|VED16|), mean ventricular delay (meanVD), and a clinically interpretable distance-to-normal metric defined as dist&#xa0;=&#xa0;max(|VED16|-20, 0). Paired changes were summarized as medians with bootstrap 95% confidence intervals and tested using the Wilcoxon signed-rank test. Associations between paced RWPT and residual dyssynchrony during pacing were evaluated using Pearson and Spearman correlation coefficients. RESULTS: LBBAP significantly narrowed QRS duration from 136.8 [130.2-153.6] ms during intrinsic rhythm to 116.0 [107.8-125.6] ms during pacing (median &#x394; -21.0&#xa0;ms; 95% CI -33.9 to -18.6; p&#xa0;<&#xa0;0.001). Signed VED16 did not change significantly (median &#x394; 0.4&#xa0;ms; p&#xa0;=&#xa0;1.000), consistent with the mixed conduction-phenotype composition of the cohort. In contrast, severity-oriented UHF-ECG endpoints improved: |VED16| decreased numerically (median &#x394; -5.2&#xa0;ms; p&#xa0;=&#xa0;0.070), whereas dist decreased significantly (median &#x394; -0.7&#xa0;ms; 95% CI -14.4 to 0.0; p&#xa0;=&#xa0;0.015). The proportion of patients within the normal dyssynchrony band (|VED16|&#xa0;&#x2264;&#xa0;20&#xa0;ms) increased from 7/21 (33.3%) to 12/21 (57.1%). Median paced RWPT was 66.6 [58.6-74.6] ms, and shorter RWPT correlated with lower residual |VED16| during pacing (Pearson r&#xa0;=&#xa0;-0.45, p&#xa0;=&#xa0;0.038). CONCLUSIONS: In patients with baseline wide QRS, LBBAP produces marked QRS narrowing, whereas UHF-ECG provides complementary quantification of residual electrical dyssynchrony. Severity-oriented UHF-ECG endpoints, particularly a distance-to-normal metric, may offer an interpretable mechanistic framework beyond conventional ECG alone. Shorter paced RWPT was associated with lower residual dyssynchrony during pacing, supporting physiological coherence between procedural and high-resolution electrocardiographic markers.

Humans

Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.

BACKGROUND: The V2&#xa0;-&#xa0;V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12&#x2011;lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2&#xa0;-&#xa0;V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12&#x2011;lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000&#xa0;Hz. In the standard recording, the digital PBL was calculated as V2&#xa0;-&#xa0;V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008&#xa0;mV). CONCLUSIONS: Physical acquisition of the V2&#xa0;-&#xa0;V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Humans