BACKGROUND: The V2 - V1 Precordial Bipolar Lead (PBL) selectively evaluates the right-to-left retrosternal axis and has shown diagnostic value beyond the standard 12‑lead electrocardiogram. However, its use has been limited by the need for raw electrocardiographic data and post-processing software. This study evaluated whether a simple physical reconfiguration of limb electrodes could reproduce the digitally derived V2 - V1 morphology with sufficient accuracy for clinical application. METHODS: Thirty-seven subjects underwent two sequential 10-s 12‑lead recordings using a Cardiovit FT-1 electrocardiograph sampled at 1000 Hz. In the standard recording, the digital PBL was calculated as V2 - V1. In the second recording, the right-arm and left-arm electrodes were repositioned to the V1 and V2 sites so that Lead I directly recorded the retrosternal dipole. Signals were filtered, synchronized, and analyzed using median beats. Morphological agreement was assessed with Pearson correlation on Z-normalized signals, while absolute agreement was evaluated using Lin's concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC (Lewis, 1931; Nehb, 1938 [1,2])), root mean square error (RMSE), and Bland-Altman analysis. RESULTS: Mean Pearson correlation between digital and physical PBL was 0.955 (SD 0.043), with segment-specific correlations of 0.953 (SD 0.054) for QRS and 0.967 (SD 0.052) for ST-T. Lin's CCC and ICC(2,1) were both 0.871 (SD 0.110), and RMSE was 0.091 (SD 0.049) mV. Bland-Altman analysis showed minimal bias (-0.008 mV). CONCLUSIONS: Physical acquisition of the V2 - V1 PBL achieved high agreement with the digitally derived signal, supporting a simplified analog method for broader clinical implementation.

Explore related subjects

Keep this discovery

BibTeXRIS

Santiago Obregón-Rosas, Mario Jorge Mc Loughlin, Paola Fabiola Carlos-Solís, Nayra Vera-Ávila, Isabella Rojas-Bergés, José Pablo Navarrete-Punaro. 2026-08-10. Physical reconfiguration of limb electrodes for Precordial Bipolar Lead acquisition: Morphological validation against digital subtraction.. https://doi.org/10.1016/j.jelectrocard.2026.154424

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Recent advances in electrode materials for electrochemical detection of zearalenone.

Zearalenone (ZEN) is an estrogenic mycotoxin commonly found in cereals, animal feed, and processed foods, making it an important concern for food safety and public health. Conventional chromatographic and immunological methods can detect ZEN; however, they often require expensive instruments, lengthy sample preparation, and skilled personnel, which restrict their use for rapid and on-site testing. Electrochemical sensors have attracted enormous interest of the scientific community because of their high sensitivity, rapid response, low cost, miniaturization potential, and compatibility with portable systems. The analytical performance of the electrochemical sensors is strongly influenced by electrode materials, morphology, conductivity, porosity, surface functionality, and the efficiency of bioreceptor immobilization. Despite several reviews on mycotoxin detection, a systematic assessment connecting electrode-material design, modification strategies, sensing mechanisms, and electroanalytical performance specifically for ZEN sensing remain limited. This review critically evaluates recent advances in metal oxides, carbon-based materials, metal-organic- and covalent organic frameworks, MXenes, polymers, and hybrid composites for electrochemical ZEN detection. Particular attention has been given to their roles in electron transfer, analyte enrichment, selectivity, and real-sample analysis. The review also compares the major limitations of current sensing systems, including complex fabrication, matrix interference, insufficient long-term stability, poor inter-electrode reproducibility, and limited scalability. Finally, future directions for developing robust, cost-effective, portable, and commercially viable ZEN sensors are discussed.

Journal Article

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14 μM and a low detection limit of 4.3 nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7 × 108 CFU/mL and a low detection limit of 1.66 CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19% ∼ 104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer