Search PubMedSearch

PubMed · 42378794

Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.

Abstract

BACKGROUND: The electrocardiogram (ECG) is widely used to infer infarct location and extent in anterior myocardial infarction (MI), based on either anatomical lead proximity or vectorial orientation of ST-segment deviation. However, the validity of these approaches against direct imaging of myocardial injury remains uncertain. METHODS: In this prospective study, 105 patients with anterior MI underwent cardiac magnetic resonance (CMR) imaging 3-7 days after presentation. Admission ECGs were analyzed using (1) conventional ECG localization categories, and (2) simplified frontal and horizontal ST-axis orientation. CMR-defined injury distribution was assessed using late gadolinium enhancement and myocardial edema imaging. RESULTS: Conventional ECG localization categories demonstrated no significant association with CMR-defined infarct distribution (P = 0.24), with poor agreement (κ = 0.122) and substantial overlap across categories. Simplified ST-axis orientation showed modest and inconsistent associations with infarct location and did not meaningfully explain infarct size. In contrast, global ST-segment burden was associated with CMR-defined infarct size (ΣSTE: standardized β = 0.307, P = 0.002; lead count: standardized β = 0.267, P = 0.007). CONCLUSIONS: In this selected cohort of reperfused LAD-related anterior STEMI patients undergoing early CMR, conventional ECG localization categories and simplified ST-axis orientation showed poor or inconsistent correspondence with CMR-defined infarct distribution, whereas global ST-segment burden showed a modest association with infarct size. These findings suggest that, in this cohort, the ECG may be better suited to reflect the extent of myocardial injury rather than its precise anatomical location.

Explore related subjects

Keep this discovery

BibTeXRIS

Emre K Aslanger, Burcu Aggül, Duygun İnan, Neslihan Taşdelen, Serçin Özkök, Dursun Akaslan, Ayça Türer Cabbar, Sema Çatal, Ömer Faruk Kamalı, Eren Uysaler, Özlem Yıldırımtürk, Muzaffer Değertekin. 2026-06-28. Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.. https://doi.org/10.1016/j.jelectrocard.2026.154405

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Prognostic value of early changes in the frontal QRS-T angle in patients with heart failure and left bundle branch block undergoing cardiac resynchronization therapy.

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in selected patients with heart failure (HF). The frontal QRS-T angle (FQTA), reflecting ventricular depolarization-repolarization heterogeneity, has been associated with major adverse cardiovascular events (MACE). We aimed to assess the prognostic value of changes in the FQTA after CRT in predicting long-term MACE. METHODS: A total of 223 consecutive HF patients with left bundle branch block who underwent CRT between 2018 and 2022 were retrospectively analyzed. The FQTA was measured before and after CRT, and the change (&#x394;FQTA) was calculated. Receiver operating characteristic (ROC) analysis was performed to determine the optimal cutoff value for predicting the primary outcome, MACE. Patients were subsequently stratified according to this cutoff value. Independent predictors were identified using multivariable Cox proportional hazards regression analysis. RESULTS: ROC analysis identified 22.5&#xb0; as the optimal cutoff value for predicting MACE (AUC: 0.711; 95% CI: 0.642-0.781; p&#xa0;<&#xa0;0.001). During a mean follow-up of 34.6&#xa0;&#xb1;&#xa0;17.6&#xa0;months, patients with &#x394;FQTA <22.5&#xb0; had a significantly higher incidence of MACE compared with those with greater angle reduction (44.7% vs. 11.9%; p&#xa0;<&#xa0;0.001). In multivariable Cox regression analysis, chronic kidney disease (HR: 2.517; p&#xa0;=&#xa0;0.002) and &#x394;FQTA <22.5&#xb0; (HR: 4.56; p&#xa0;<&#xa0;0.001) were independently associated with MACE. CONCLUSION: A greater reduction in FQTA after CRT is associated with improved long-term outcomes and may serve as a practical electrocardiographic marker for risk stratification.

Humans