Search PubMedSearch

PubMed · 42497467

Reliability of resting heart rate measurements in atrial fibrillation.

Abstract

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Explore related subjects

Keep this discovery

BibTeXRIS

Anders P Persson, William F McIntyre, Taya Glotzer, Jason G Andrade, David Conen, Artur Fedorowski, Alexandra M&#xe5;neheim, Johan Economou Lundeberg, Tord Juhlin, Albin Edegran, Agnieszka Grotek-Cuprjak, Jeff S Healey, Gunnar Engstr&#xf6;m, Michiel Rienstra, Linda S Johnson. 2026-07-18. Reliability of resting heart rate measurements in atrial fibrillation.. https://doi.org/10.1016/j.jelectrocard.2026.154408

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Integrative multi-omics reveals a fibroblast-centered, ZFHX3-prioritized regulatory framework linking sick sinus syndrome and atrial fibrillation.

OBJECTIVE: To define shared genetic and multi-scale mechanisms underlying comorbidity between sick sinus syndrome (SSS) and atrial fibrillation (AF). METHODS: We integrated genome-wide association study (GWAS) summary statistics for SSS and AF with Genotype-Tissue Expression (GTEx) expression and splicing quantitative trait loci (eQTL/sQTL), atrial single-cell and spatial transcriptomics, and epigenomics. We identified trait-relevant tissues and pathways, prioritized shared cell types, quantified genome-wide and local genetic sharing, detected joint loci by cross-trait meta-analysis, and linked loci to regulatory programs via colocalization and cell-prioritized co-expression networks. RESULTS: Both traits showed strongest enrichment in cardiac tissue, especially Heart Atrial Appendage. Fibroblasts from the left atrial appendage were consistently prioritized as the key shared cell population. SSS and AF displayed significant positive genome-wide genetic correlation, with multiple locally shared regions, including six major loci. Cross-trait meta-analysis identified eight joint-phenotype SNPs implicating four susceptibility genes. ZFHX3 was the leading tissue-cell-gene candidate, acting as a hub in fibroblast co-expression modules and colocalizing with cardiac regulatory signals. CONCLUSION: Shared liability for SSS and AF is highly tissue- and cell-specific, converging on regulatory networks in atrial appendage fibroblasts, with ZFHX3 serving as a central mechanistic and biomarker node.

Humans

Incidence of silent cerebral lesions during pulsed field ablation for paroxysmal atrial fibrillation.

BACKGROUND: Radiofrequency catheter ablation (RFCA) is a first-line treatment for paroxysmal atrial fibrillation (PAF). Complications such as silent cerebral lesion (SCL) may occur during ablation. Pulsed field ablation (PFA) is a non-thermal method thatablates cardiac tissue via irreversible electroporation. Limited studies have reported the incidence of SCL during PFA, with highly variable results. However, randomized controlled trials (RCTs) remain scarce. The objective of this study was to compare perioperative SCL incidence between PFA and RFCA, and to identify risk factors for SCL during PFA. METHODS: In this prospective pilot RCT (ChiCTR2400088774), 62 patients with PAF were randomized 1:1 to undergo PFA or RFCA. Cerebral MRI (3.0 T) was performed preoperatively and 24-48h postoperatively. SCL was defined as a new acute brain lesion on MRI without neurological deficits. Baseline and surgical data of the patients were collected. RESULTS: SCL was detected post-procedure in 6.45% (2/31) in the RFCA group, 12.90% (4/31) in the PFA group. No statistically significant difference in the incidence of postoperative SCL was detected between the two groups (p&#x2009;=&#x2009;0.67). Left atrium dimension (LAD), left atrial operation time (LAOT), left ventricular end-diastolic dimension (LVEDD), and total operation time (TOT) were significantly higher in SCL group than those in no-SCL group (p&#x2009;<&#x2009;0.05) through univariate analyses. CONCLUSIONS: SCL incidence was 12.90% in the PFA group versus 6.45% in the RFCA group. While no statistically significant difference was detected between two groups, the numerically higher rate in the PFA group warrants larger studies to evaluate cerebral safety associated with PFA.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation