Search PubMedSearch

SEARCH · Search PubMed

Results for “split sample reliability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

488 recordsLinked to original sources

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Development of a cell-based nanoluciferase reporter system for high-throughput screening of HBV cccDNA inhibitors.

Hepatitis B virus (HBV) persistence is sustained by the viral covalently closed circular DNA (cccDNA) minichromosome, which remains a major barrier to curative antiviral therapies. The lack of reliable quantitative cccDNA detection methods and surrogate markers has hindered efforts to target cccDNA in antiviral high-throughput screening (HTS). Here, we established a novel inducible cccDNA-dependent nanoluciferase (NLuc) reporter cell line, designated HepBLE12, by inserting an in-frame 11-amino acid split-NLuc HiBiT tag into the precore (pC) coding region of an HBV transgene. The resulting 1.3-kDa HiBiT tag on pC serves as the detection module of the split NLuc system, generating quantitative luminescence upon high-affinity complementation with the cognate 18-kDa LgBiT subunit in cell lysates. Notably, the HiBiT assay enables direct detection of intracellular HiBiT-pC protein rather than secreted HBeAg, providing a reporter signal more closely linked to cccDNA activity. HepBLE12&#x202f;cells exhibited inducible and robust viral DNA replication, and the cccDNA-dependent HiBiT signal was validated under diverse experimental conditions that modulate cccDNA formation or transcription. We further miniaturized the assay to a 384-well format and optimized key parameters following standard HTS assay development practices. The assay was successfully automated and demonstrated excellent performance in a multi-day variability study and a pilot screen, with signal-to-background (S/B)&#x202f;&#x2248;&#x202f;9, coefficient of variance (CV)&#x202f;<&#x202f;10%, and average Z-factor value of 0.74, exceeding canonical HTS quality benchmarks. Together, the HepBLE12 cell-based HTS platform provides a robust and practical tool for identifying inhibitors targeting HBV cccDNA.

Hepatitis B virus

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Comparison of a 755-nm picosecond laser and a 1565-nm nonablative fractional laser for the treatment of atrophic acne scars: a 20-week prospective, randomized, split-face clinical study.

To compare the efficacy and safety of a 755-nm picosecond laser with a diffractive lens array (P-DLA) and a 1565-nm nonablative fractional laser (NAFL) for the treatment of atrophic acne scars. Twenty-seven patients with atrophic acne scars underwent three sessions of randomized split-face treatment with P-DLA and NAFL at 4-week intervals. Patients were followed up at 1, 2, and 3 months after the final treatment. Efficacy was assessed using the &#xc9;chelle d'&#xc9;valuation Clinique des Cicatrices d'Acn&#xe9; (ECCA) grading scale, the Investigator's Global Assessment (IGA) score, patients' self-rated improvement, and overall satisfaction. Treatment-related adverse reactions were recorded daily by patients until resolution. Both modalities demonstrated significant improvements in scar appearance based on ECCA score, IGA score, and patients' self-rated improvement (P&#x2009;<&#x2009;0.001). No statistically significant differences in efficacy were observed between the two treatments. However, the P-DLA group showed higher patient satisfaction (P&#x2009;=&#x2009;0.035) and a more favorable safety profile, including shorter durations of erythema and edema and the absence of crusting. Both P-DLA and NAFL were effective and safe for the treatment of atrophic acne scars, with similar efficacy. P-DLA offered better tolerability.

Humans

Comparison of conventional and micro-surgical techniques for gingival recession using collagen matrix: Randomised controlled split-mouth clinical trial.

BACKGROUND: The present study aimed to determine the effectiveness of the microsurgical approach in treating gingival recession with collagen matrix by comparing it with Conventional surgery in terms of clinical and patient-centered outcomes. METHODS: A total of 29 patients with bilateral gingival recession in the maxillary canine and/or premolar region were selected. After randomisation, bilateral recession sites were grouped into the test group (Microsurgery under 3.5 X magnification) and the control group (Conventional surgery). All the clinical and patient-reported parameters were recorded at baseline, 1, 3 and 6 months. RESULTS: Both groups showed statistically significant differences in terms of reduction in gingival recession height (GRH), gingival recession width (GRW), clinical attachment level gain (CAL gain), increase in keratinized tissue thickness (KTT) and keratinized tissue width (KTW) after 6 months. But intergroup comparison showed no significant difference in terms of clinical parameters. The only significant difference was noted in terms of patient-centred parameters (Patient satisfactory score, Hypersensitivity score, Root aesthetic scores), which favoured the microsurgical group. CONCLUSIONS: Both groups demonstrated comparable clinical improvement; However, Patient-centred parameters were significantly better with the Microsurgical approach. Selection of the surgical approach should balance patient needs with practical considerations like cost, time, and clinician proficiency.

Adult

Photothermal-Activated Platelet-Rich Plasma Versus Conventional Platelet-Rich Plasma for Melasma: A Split-Face, Double-Blind Randomized Controlled Trial.

BACKGROUND: Melasma is a common acquired pigmentary disorder that predominantly affects women with darker skin types and substantially impairs quality of life. Current treatments are limited by variable efficacy, adverse effects, and frequent recurrence. Platelet-rich plasma (PRP) has emerged as a potential regenerative treatment through growth-factor-mediated modulation of melanogenesis. Photothermal activation, which combines photobiomodulation with controlled hypothermic conditioning, has been hypothesized to promote a more sustained growth-factor release than conventional PRP. This study compared the efficacy and safety of photothermal-activated PRP (PT-PRP) and conventional PRP (C-PRP) for melasma treatment. METHODS: This split-face, double-blind, randomized controlled trial included 26 women with epidermal or mixed-type melasma. Each participant received three monthly sessions of intradermal PRP, with PT-PRP and C-PRP injected into opposite facial sides. Outcomes were assessed at weeks 0, 4, 8, and 12 using the modified Melasma Area and Severity Index (mMASI), Mexameter melanin and erythema indices, patient satisfaction, overall improvement, and adverse events. RESULTS: Both treatments significantly reduced mMASI by week 12, with no significant between-group differences at any time point. C-PRP showed significant mMASI improvement from week 4, whereas PT-PRP reached significance from week 8. For the melanin index, PT-PRP produced a significant within-group reduction at week 12, while C-PRP did not. At week 12, PT-PRP showed a significantly lower melanin index than C-PRP. Mild injection-site bruising was the only adverse event. CONCLUSION: PT-PRP and C-PRP produced comparable clinical improvement, but PT-PRP achieved greater objective melanin reduction at week 12. PT-PRP may represent a safe alternative treatment for melasma. TRIAL REGISTRATION: Thai Clinical Trials Registry: TCTR20260318004.

Humans

Effect of self-activating phthalocyanine gel on palatal donor site healing, inflammatory biomarkers, somatosensory and patient-centered outcomes: a randomized split-mouth clinical trial.

OBJECTIVES: To evaluate effects of self-activating phthalocyanine (PHY) gel on palatal donor site after subepithelial connective tissue graft (SCTG) harvesting, considering clinical outcomes, inflammatory biomarkers, patient-centered outcomes, and quantitative somatosensory changes. MATERIALS AND METHODS: Twenty participants were included in this randomized, crossover, split-mouth clinical trial. Donor sites received topical PHY gel (PHY group-PHYG) and placebo gel (control group-CG). Clinical parameters (residual wound area-RWA, wound epithelialization-WE, residual remodeling area-RRA and tissue thickness-TM) were assessed at baseline, 7, 14, 30, and 60 days. Patient-centered outcomes were recorded during 14 postoperative days and inflammatory biomarkers at 3 and 7 days postoperatively. Mechanical detection threshold (MDT) and mechanical pain threshold (MPT) were evaluated at baseline, 2 months, and 6 months. RESULTS: PHYG and CG exhibited similar clinical outcomes, but PHYG demonstrated superior performance in reducing RRA. Both groups presented positive postoperative progression of patient-centered outcomes. IL-10 levels showed a significant increase in PHYG, suggesting a more favorable anti-inflammatory response. MDT remained stable but, donor sites exhibited transient hypersensitivity (MPT) at 2 months. CONCLUSIONS: PHYG and CG protocols promoted satisfactory healing of palatal donor sites. Most clinical parameters and patient-centered outcomes were similar between groups. The PHYG presented reduced RRA and increased IL-10 levels. Donor sites exhibited transient hypersensitivity, which tended to resolve over time. CLINICAL RELEVANCE: Both postoperative protocols resulted in favorable healing of palatal donor sites following SCTG harvesting, with comparable clinical and patient-centered outcomes. Quantitative sensory testing indicates that hypersensitivity may occur during healing, but sensory function tends to recover progressively.

Humans

Efficacy and safety of split-dose ultra-low-volume polyethylene glycol with ascorbic acid versus sodium picosulfate with magnesium citrate for bowel preparation: a systematic review and meta-analysis.

Colonoscopy remains the gold standard for early detection and prevention of colorectal cancer, with adequate bowel cleansing being pivotal for its success. This systematic review aims to evaluate the efficacy and safety of split-dose ultra-low-volume polyethylene glycol (PEG) with ascorbic acid (Asc) versus sodium picosulfate magnesium citrate for bowel preparation. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we conducted a comprehensive literature search across Embase, PubMed, Web of Science, and Scopus from inception to July 2025. Data analysis was conducted using R version 4.2.2 (31 October 2022) and RStudio version 2022.07.2 (2009-2022, RStudio, Inc.) Our literature search yielded six eligible studies involving 3285 patients. Our findings indicate no significant differences in overall and right-sided colon adequate cleansing rates between the two regimens: risk ratio: 1.05, 95% confidence interval (CI): 0.99-1.12, P &#x2005;=&#x2005;0.1082; and risk ratio: 1.03, 95% CI: 0.99-1.08, P &#x2005;=&#x2005;0.1755, respectively. However, PEG + Asc demonstrated a significantly lower rate of vomiting compared to sodium picosulfate magnesium citrate (risk ratio: 2.58, 95% CI: 0.94-2.78, P &#x2005;=&#x2005;0.0008), suggesting better tolerability. Other secondary outcomes, including nausea, abdominal pain, and overall Boston Bowel Preparation Scale scores, did not show significant differences. The quality of the evidence varied across the outcomes. Our results support the comparable efficacy of both bowel preparation agents while highlighting PEG + Asc's potential advantages in tolerability. Our findings suggest that the choice between these two preparations can be tailored to the specific patient, considering their preferences or previous experiences, although some caution is advised in interpreting these findings.

Humans

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Peptide molecular lock-engineered nanobodies enable an oriented dual-modal immunoassay for reliable detection of Cronobacter sakazakii.

Conventional nanobody ELISAs for trace Cronobacter sakazakii in powdered infant formula suffer from random orientation and low signal output. We developed an oriented dual-modal immunoassay that combines site-specific biotinylation via a C-terminal AviTag and a peptide molecular lock, enabling controlled surface orientation while preserving nanobody structural integrity. This strategy was further integrated with phage-displayed nanobodies for multivalent amplification and both fluorescent and colorimetric readouts. The assay exhibited a broad linear range of 103-106&#xa0;CFU/mL, with limits of detection (LODs) of 6.70&#xa0;&#xd7;&#xa0;102&#xa0;CFU/mL for fluorescence and 1.55&#xa0;&#xd7;&#xa0;103&#xa0;CFU/mL for colorimetry, showing improved sensitivity compared with the conventional passive adsorption-based Nb-ELISA evaluated in this study. XGBoost-based multimodal fusion improved quantitative accuracy, and SHAP analysis elucidated modality contributions. In spiked powdered infant formula samples, recoveries ranged from 92.1% to 118% with coefficients of variation below 5.98%, confirming acceptable matrix tolerance and analytical reliability.

Cronobacter sakazakii

Liquid biopsy-based detection of circulating and exfoliated cholangiocarcinoma tumor cells from blood and bile using heparan sulfate octasaccharides on integrated microfluidic systems.

Early diagnosis of cholangiocarcinoma (CCA) remains challenging because existing diagnostic approaches often lack sufficient sensitivity for reliable detection of early-stage disease. Circulating tumor cells (CTCs) in blood and exfoliated tumor cells (ETCs) in bile represent valuable targets for liquid biopsy-based detection; however, their low abundance and the complexity of clinical sample analysis pose substantial technical challenges for reliable enrichment and identification. Herein, we present a reproducible workflow for isolating and identifying CCA tumor cells from blood for CTCs and bile for ETCs using synthetic cell-surface heparan sulfate (HS) octasaccharide-functionalized magnetic beads (MBs) on integrated microfluidic systems. The method combined sample pre-processing, magnetic bead-based enrichment, controlled low-shear mixing and immunofluorescence-based identification into a unified workflow compatible with distinct clinical sample types. Key operational parameters, including MB concentration, mixing frequency, and pressure settings, were detailed to facilitate consistent performance. Using this workflow, tumor cell capture rates of approximately 70% in bile (for ETCs) and blood (for CTCs) were achieved, with a total processing time of 60-90&#xa0;min per sample under clinically relevant low-abundance conditions. The platform enables reliable detection of as few as 1 tumor cell per mL of blood or bile. This method provides a practical and adaptable strategy for glycosaminoglycan-mediated liquid biopsy applications and may be extended to other tumor-cell enrichment workflows involving heterogeneous cell-surface interactions.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Uce-based phylogeny and classification of Megachilini.

The generic-level classification of the bee tribe Megachilini (Megachilidae) has remained controversial due to poor phylogenetic resolution at the base of the group, particularly among the brood parasitic genera and the numerous dauber ("Chalicodoma s. l.") lineages. We present a phylogenomic analysis of Megachilini based on ultraconserved elements (UCEs), sampling 52 ingroup taxa with emphasis on the dauber lineages. We also present a combined UCE&#xa0;+&#xa0;six-gene analysis to improve taxon coverage, resulting in a dataset with 127 ingroup taxa. Maximum likelihood, coalescent, and Bayesian analyses of multiple UCE matrices recover largely congruent topologies with substantially improved support relative to previous studies. Our results strongly support the monophyly of Megachilini, the early divergence of Noteriades and Gronoceras, and a single origin of brood parasitism. All remaining non-parasitic Megachilini form a moderately supported clade sister to the brood parasitic lineage. The leafcutter bees are monophyletic and nested within dauber lineages. Several major dauber clades are consistently recovered, including an exclusively Australian clade corresponding to the Hackeriapis group of subgenera, while several recognized subgenera are paraphyletic. The lineage known as Morphella, previously placed in synonymy with the subgenus Callomegachile, was not closely related to that subgenus and is here treated as a valid subgenus. Divergence-time analyses place the crown age of Megachilini in the late Eocene to early Oligocene, with major extant lineages diversifying during the Miocene. Limited morphological diagnosability of several clades indicates that splitting non-parasitic lineages into numerous genera would result in an impractical classification that would widen the gap between taxonomists and non-specialists and exacerbate the taxonomic impediment in bees. We therefore advocate retaining a single genus Megachile for non-parasitic Megachilini (excluding Noteriades and Gronoceras), as the classification best supported by phylogenomic evidence and most robust to future taxon sampling.

Animals

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n&#x2009;=&#x2009;10, 62.5%), language (n&#x2009;=&#x2009;2, 12.5%), gait (n&#x2009;=&#x2009;2, 12.5%), caregiver proximity (n&#x2009;=&#x2009;1, 6.3%), EEG power (n = 1, 6.3%),&#xa0;and arousal (n&#x2009;=&#x2009;1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps,&#xa0;and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans

Cross-kingdom dynamics of the subgingival bacteriome and mycobiome: A pilot study on the effects of a novel HA-H&#x2082;O&#x2082;-Glycine formulation to treat periodontitis.

OBJECTIVES: Traditional periodontal therapy primarily focuses on bacterial biofilm control; however, recent evidence also suggests a critical role for the oral mycobiome. This study evaluated the clinical and ecological impact of a novel mouthwash formulation containing hyaluronic acid (HA), hydrogen peroxide (H2O2), and glycine on periodontal patients METHODS: This prospective, randomized split-mouth trial included 13 adult participants with periodontitis treated with HA-H2O2-glycine formula (BMG0703A) used twice a day for seven days. Subgingival plaque samples were collected from periodontal pocket and healthy control sites at baseline (T0) and one-week post-treatment (T1). Microbial and fungal communities were characterized using Next-Generation Sequencing (NGS) of the 16S rRNA and ITS2 regions. Linear Mixed Models (LMM) and Spearman correlation were used to assess taxonomic shifts and cross-kingdom relationships. RESULTS: Sequencing revealed a promising ecological shift: the bacteriome shifted from anaerobic dominance (Olsenella, Peptostreptococcus) toward a health-associated aerobic profile, with Rothia near-doubling (11.91% to 22.68%). The mycobiome underwent a "normalization" effect: Candida abundance decreased significantly (22.8% to 9.1%), while fungal Shannon diversity in pockets returned to healthy-site levels. Inter-kingdom analysis identified antagonistic relationships between expanding commensal bacteria and opportunistic fungi, suggesting that the intervention may help re-establish a protective bacterial niche. CONCLUSIONS: The HA-H2O2-glycine formulation seems to facilitate a rapid, cross-kingdom modulation of the subgingival niche. By reducing anaerobic pathogens and normalizing the mycobiome it appear to induce short-term changes, suggesting potential as adjunctive strategy in periodontal management. CLINICAL SIGNIFICANCE: The present work underlines the possible cross-Kingdom effects of a novel compound.

Humans

The asymmetry of working memory training transfer: A systematic review and meta-analysis.

Working memory (WM) training is widely used to enhance cognitive performance; however, its transfer to untrained tasks remains controversial. Traditional theories emphasize task similarity as the primary determinant of training transfer, but they cannot fully explain emerging evidence of asymmetric transfer across tasks. Two directional transfer hypotheses are proposed here to explain this asymmetry: the resource-based transfer advantage hypothesis predicts stronger transfer from more to less cognitively demanding tasks, whereas the ability-based transfer advantage hypothesis predicts stronger transfer from tasks engaging broader task-general abilities to tasks engaging task-specific narrower abilities. The contrast between span and updating paradigms provides an informative framework for distinguishing these accounts, because updating tasks are generally more cognitively demanding, whereas span tasks involve broader abilities. Accordingly, we conducted a three-level meta-analysis of 55 studies (208 effect sizes; N = 3,492). The results showed that updating training transferred reliably to span tasks (g = 0.176, p < .001), whereas span training did not reliably transfer to updating tasks (g = 0.048, p = .453), supporting the resource-based account. This advantage of updating training also extended to non-WM outcomes and was more pronounced at lower training doses, in non-adult samples, and with verbal stimuli. Together, these findings extend WM transfer theory beyond task similarity by highlighting the importance of cognitive demand and offer guidance for WM training design.

Humans

Fractional laser therapy versus microneedling for non-acne scars and scar-like dermal fibrotic lesions.

BACKGROUND: Scarring caused by trauma, burns, surgery, and other dermal fibrotic conditions can lead to functional limitation and cosmetic distress. The comparative effectiveness of fractional laser therapy and microneedling for non-acne scars remains uncertain. METHODS: We conducted a systematic review and meta-analysis of randomized controlled trials comparing fractional laser therapy with microneedling for non-acne scars and scar-like dermal fibrotic lesions. Following a PROSPERO-registered protocol and PRISMA guidelines, we searched PubMed, EMBASE, Web of Science, Cochrane Library, and CNKI from inception to May 2026 without language restrictions. Parallel-group and split-body randomized trials were eligible. Random-effects models were used to calculate standardized mean differences (SMDs) for continuous outcomes and odds ratios (ORs) for dichotomous outcomes. RESULTS: Nine randomized controlled trials were included. Fractional laser therapy showed a statistically significant advantage over microneedling in scar scores (SMD = -0.99, 95% CI [-1.83, -0.15], P&#x2009;=&#x2009;0.02) and collagen fiber regeneration (SMD = -2.14, 95% CI [-3.57, -0.72], P&#x2009;=&#x2009;0.03). No statistically significant differences were found between the two interventions for elastic fiber improvement, epidermal thickness, or adverse events. Subgroup analyses did not show clear or consistent significant differences according to laser type, including comparisons between traditional and non-traditional fractional lasers and between CO&#x2082; and non-CO&#x2082; fractional laser systems. Substantial heterogeneity was observed across several outcomes, indicating considerable between-study variability. CONCLUSION: Based on currently available randomized evidence, fractional laser therapy may provide superior improvement in overall scar severity and collagen fiber regeneration compared with microneedling for non-acne scars and scar-like dermal fibrotic lesions. However, no clear differences were observed for elastic fiber improvement, epidermal thickness, or adverse-event incidence. Given the substantial heterogeneity, limited sample sizes, and possible reporting bias, these findings should be interpreted cautiously. Further large, standardized trials with longer follow-up are needed.

Humans

Longitudinal associations between family factors and the neurodevelopmental and psychosocial outcomes of children with congenital heart disease: A systematic review.

Family factors have been gaining increased attention in understanding adverse neurodevelopmental and psychosocial outcomes for children with congenital heart disease (CHD). To clarify relevance, we undertook a systematic review of only longitudinal studies which assessed such associations. Comparisons with the contribution of disease/surgical factors were also made where included studies considered such. We included longitudinal studies which assessed dynamic family factors (e.g. parent mental health, attachment, family functioning) and later child outcomes. Searches were conducted across CINAHL, Medline-Pubmed, PsychInfo and SCOPUS Web of Science. The NIH Quality Assessment Tool was used to evaluate study quality and risk of bias. Eighteen studies, utilizing data from 11 study samples and 2109 participants, met inclusion criteria. These studies included samples from infancy, with follow-up periods stretching into young adulthood, and with various degrees of CHD severity. The quality of studies was "good" to "fair", with key limitations of attrition and limited sociocultural diversity in samples. Findings suggested that family factors predicted later child psychosocial outcomes and more consistently than severity of disease indicators. This contrasted with a much smaller number of studies examining family factors and child neurodevelopmental outcomes, where no reliable conclusions could be reached. Findings highlight the importance of screening and family focused interventions for this population.

Child