Search PubMedSearch

SEARCH · Search PubMed

Results for “contrast-enhanced computed tomography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

752 recordsLinked to original sources

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

INTRODUCTION: Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT. METHODS: This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used. RESULTS: The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 ± 139 HU; P = 0.107). CONCLUSION: Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality. IMPLICATIONS FOR PRACTICE: These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

Humans

Novel non-contrast computed tomography parameters for predicting spontaneous stone passage and surgical requirement in ureteral stones: The role of ureteral wall thickness and dilatation ratio.

We investigated the predictive value of standard non-contrast computed tomography (NCCT) measurements, the ureteral dilatation ratio (DDR) and intraluminal urine stasis markers, for spontaneous stone passage (SSP) versus surgical intervention in patients with ureteral stones. We also evaluated ureteral wall thickness (UWT) as a practical clinical marker. This retrospective study included 461 patients diagnosed with ureteral stones via NCCT. Patients were categorised into two groups based on clinical outcomes: the spontaneous passage group (MET; n&#x2009;=&#x2009;229) and the endoscopic surgery group (URS; n&#x2009;=&#x2009;232). Stone volume, stone density (HU), UWT, DDR and intraluminal urine attenuation values were measured for all patients. Independent risk factors were identified using a multivariate logistic regression model and clinical cut-off values were determined via ROC curve analysis. Stone volume, density, UWT and hydronephrosis grade were all significantly higher in the URS group. Multivariate regression analysis revealed that increased UWT (OR: 5.03, 95% CI: 3.66-6.90; p&#x2009;<&#x2009;0.001) was the strongest independent predictor of surgery. Higher DDR (OR: 1.88; p&#x2009;=&#x2009;0.003), advanced hydronephrosis, stone volume, and density also increased surgical risk. A UWT cut-off &#x2265;&#x2009;2.97&#xa0;mm predicted surgery with 84.8% sensitivity and 84.3% specificity (AUC: 0.872). A DDR cut-off >&#x2009;1.79 yielded 81.7% specificity and 40.4% sensitivity. UWT weakly correlated with stone volume (r&#x2009;=&#x2009;0.145), indicating wall thickening reflects an inflammatory response rather than a mere mechanical consequence. UWT is a superior predictor of SSP failure, supported by increased DDR as a highly specific complementary risk factor. These parameters could help clinicians to identify patients who would benefit from early surgical counselling and intervention rather than prolonged conservative management.

Humans

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Imaging&#x2011;based models for predicting cerebrovascular complications of carotid stenosis.

This is a protocol for a Cochrane review (prognosis). The objectives are as follows: Primary objective To systematically review and critically appraise multivariable prognostic models developed for adults (&#x2265;&#x202f;18&#x202f;years) with carotid stenosis in which imaging biomarkers (e.g. plaque characteristics derived from magnetic resonance imaging (MRI), computed tomography (CT), or ultrasound) constitute the core predictors. The primary focus is to evaluate the predictive performance of these models for cerebrovascular complications - specifically ipsilateral ischaemic stroke and transient ischaemic attack (TIA) - which are the clinical outcomes to be predicted. Where feasible, we will summarise and compare the models' discrimination (C&#x2011;statistic/area under the curve (AUC)) and calibration (calibration&#x2011;in&#x2011;the&#x2011;large, calibration slope, observed&#x2011;to&#x2011;expected ratio) across studies, and assess their potential for clinical application and external validation. For the purpose of defining symptomatic carotid stenosis as an eligibility criterion and subgroup variable, we will include studies that also considered retinal ischaemia (e.g. retinal embolism, amaurosis fugax) as a qualifying event. Secondary objectives To describe the combinations of imaging markers, modelling techniques, sample sizes, and variable&#x2011;selection strategies used in the development of the included models To evaluate the performance of these models for additional secondary clinical outcomes: plaque progression or regression, incident high&#x2011;risk imaging features, and the transition from asymptomatic to symptomatic disease To explore whether predictive performance differs according to imaging modality (MRI versus CT versus contrast&#x2011;enhanced ultrasound (CEUS)) or technical protocol (e.g. 3&#x202f;T versus 1.5&#x202f;T, spectral CT versus conventional CT) For studies that report both cerebrovascular and broader cardiovascular outcomes (major adverse cardiovascular events, myocardial infarction, etc.), we will only extract the performance metrics relating to cerebrovascular events for the primary analysis. Performance metrics for cardiovascular outcomes will be considered exploratory and will not form part of the main synthesis.

Humans

The role of artificial intelligence in the diagnosis and prognosis of traumatic brain injury based on brain CT scans: a systematic review.

Traumatic brain injury (TBI) is a leading cause of emergency department visits and a major contributor to injury-related mortality and long-term neurological disability. Non-contrast computed tomography (CT) is the gold-standard imaging modality for the rapid diagnosis of TBI. Clinical outcomes depend strongly on early detection and prompt acute management. Artificial intelligence (AI)-based models may support faster automated identification of traumatic findings and early prediction of patient prognosis.&#xa0;A systematic literature search was conducted in PubMed/MEDLINE, Scopus, IEEE Xplore, ACM Digital Library, and the Cochrane Library in accordance with PRISMA 2020 guidelines to evaluate AI-based models for automated detection of TBI-related findings on CT and for prediction of clinical outcomes. Risk of bias and applicability were assessed using QUADAS-2 for diagnostic accuracy studies and PROBAST&#x2009;+&#x2009;AI for prediction model studies.&#xa0;Twenty-two studies were included. Sixteen studies evaluated diagnostic tasks and 10 evaluated prognostic outcomes, with four studies contributing to both categories. Diagnostic performance was generally high, with many studies reporting AUC values approaching or exceeding 0.90, particularly for larger lesion volumes.Prognostic performance was more variable, with moderate to high discrimination and substantial heterogeneity. Only 9 studies incorporated independent external validation, and performance was frequently lower in external cohorts. All prognostic model studies were judged to be at high overall risk of bias using PROBAST&#x2009;+&#x2009;AI, and most diagnostic accuracy studies also demonstrated high or unclear risk of bias in at least one QUADAS-2 domain, most frequently in patient selection.&#xa0;AI-based models applied to brain CT demonstrate strong technical performance for both diagnostic and prognostic tasks in TBI. However, most studies relied on retrospective designs and lacked independent external validation which limits models generalizability and raises concern for potential overfitting. Prospective, multicenter studies with standardized methodologies and rigorous external validation are required before widespread clinical implementation.

Humans

Imaging-based surgical stratification of parasagittal meningiomas involving the superior sagittal sinus: a case analysis of 62 patients.

OBJECTIVE: The objective was to evaluate the Superior Sagittal Sinus Involvement Grading (SSIG) system as an imaging-based surgical stratification framework for parasagittal meningiomas adjacent to the superior sagittal sinus (SSS) and to assess its relationship with established sinus invasion grading, venous sinus patency, and operative strategy. METHODS: In this single-center retrospective cohort study, the authors included 62 consecutive parasagittal meningioma resections performed by a single surgeon. SSIG grade was assigned primarily on contrast-enhanced coronal MRI, with CT/MR venography used when available to evaluate sinus patency and collateral venous drainage. Operative variables, resection strategy, and clinicopathological factors were compared across SSIG and Sindou grades, and postoperative complications were compared between low- and high-involvement SSIG groups. RESULTS: SSIG correlated significantly with Sindou grade (rs = 0.790, &#x3c4;b = 0.702, both p < 0.001), and among patients with available venous imaging, it also correlated with the venous sinus involvement grade (rs = 0.742, &#x3c4;b = 0.665, both p < 0.001). With increasing SSIG grade, operative time, intraoperative blood loss, and intraoperative fluid administration increased (p = 0.012, p = 0.008, and p = 0.007, respectively). Compared with the low-involvement group (SSIG grades 1, 2, and 4a), the high-involvement group (SSIG grades 3, 4b, and 5) was less likely to achieve Simpson grade I resection and more likely to adopt Simpson grades II-III strategies (66.7% vs 13.6%, p < 0.001; OR 12.667). Surgery-related complication rates did not differ significantly between groups. The mean follow-up was 13.3 &#xb1; 7.9 months, with no radiographic recurrence or progression at last follow-up. CONCLUSIONS: SSIG characterizes parasagittal meningiomas by integrating sinus invasion, venous patency, falcine extension, and parasagittal convexity involvement on preoperative imaging. This surgically oriented framework may help anticipate operative exposure, sinus handling, and resection strategy. Its predictive value for complications and long-term oncological outcomes requires validation in larger cohorts with longer follow-up.

Humans

Respiratory effects of recruitment maneuvers according to lung recruitability assessed by electrical impedance tomography in patients with acute respiratory distress syndrome.

Recruitment maneuvers (RM) can improve oxygenation in patients with acute respiratory distress syndrome (ARDS), but their physiological effects depend on lung recruitability. This secondary analysis of a randomized controlled trial (RCT) evaluated oxygenation, respiratory mechanics, regional ventilation, and cardiorespiratory adverse events responses to a RM followed by electrical impedance tomography (EIT)-guided PEEP titration, using EIT to assess lung recruitability. In this study, fifty patients with moderate-to-severe ARDS underwent a stepwise RM followed by individualized PEEP titration guided by EIT. Lung recruitability was determined using the collapse index at PEEP 6 cmH&#x2082;O (CLPEEP6), defined as the proportion of collapsed lung at this PEEP level. Patients were classified into high- and low-recruitability groups based on median CLPEEP6 values. Oxygenation (PaO&#x2082;/FiO&#x2082;), static compliance (Cstat), driving pressure (Pdriv), regional ventilation distribution, and cardiorespiratory adverse events were compared before and after RM, during subsequent individualized EIT-guided PEEP titration. In patients with high recruitability (CLPEEP6&#x2009;>&#x2009;12.5), the PaO&#x2082;/FiO&#x2082; ratio and Cstat increased significantly after RM (PaO&#x2082;/FiO&#x2082;: 100.8&#x2009;&#xb1;&#x2009;30.3 vs. 125.4&#x2009;&#xb1;&#x2009;38.3&#xa0;mmHg, p&#x2009;<&#x2009;0.05; Cstat: 21.5&#x2009;&#xb1;&#x2009;5.8 vs. 28.0&#x2009;&#xb1;&#x2009;7.0&#xa0;mL/cmH&#x2082;O, p&#x2009;<&#x2009;0.001), Pdriv decreased (19.1&#x2009;&#xb1;&#x2009;3.5 vs. 15.6&#x2009;&#xb1;&#x2009;3.2 cmH&#x2082;O, p&#x2009;<&#x2009;0.001). EIT demonstrated a posterior redistribution of ventilation after RM. In contrast, patients with low recruitability (CLPEEP6&#x2009;&#x2264;&#x2009;12.5) showed no significant mechanical or oxygenation improvement and transient hypotension, arrhythmia, and desaturation appeared numerically more common in this group. No barotrauma or cardiac arrest occurred, and ICU mortality was similar between groups. A strategy combining a RM with subsequent individualized EIT-guided PEEP titration was associated with improved oxygenation and lung mechanics in patients with high lung recruitability, whereas patients with low recruitability showed limited physiological benefit, with cardiorespiratory adverse events appearing numerically more frequent. The EIT-derived CLPEEP6 index represents a feasible and clinically applicable https://clinicaltrials.gov/study/NCT06733168.

Humans

The utility of 18F-fluorodeoxyglucose PET/computed tomography in relapsing polychondritis: a systematic review and meta-analysis.

Relapsing polychondritis is a rare chronic autoimmune inflammation of the cartilage associated with life-threatening respiratory complications. Currently, no clear role of imaging modalities such as 18F-fluorodeoxyglucose (FDG) PET/computed tomography (CT) is defined in the literature. This systematic review and meta-analysis provide current evidence on the PET-positivity rate and utility in relapsing polychondritis. Prospective or retrospective studies with more than five patients of suspected relapsing polychondritis who underwent 18F-FDG PET/CT during their management and reported a PET-positivity rate were included. Low-sample-size studies describing chondritis due to other aetiologies or utilizing PET-based radiopharmaceuticals other than FDG were excluded. A systematic search using relevant keywords was conducted across four databases (PubMed, Embase, Scopus and Web of Science) to include studies up to 25 April 2025. The Joanna Briggs Institute critical appraisal tools were used for risk-of-bias analysis. Data were analysed using the R software package (v4.3.1; 2023). Out of 962 articles, three with a total of 97 patients were included. With a pooled PET-positivity rate of 94% [95% confidence interval (CI): 73-99%, I2&#x2005;=&#x2005;0%, P&#x2005;=&#x2005;0.76] and a pooled baseline SUVmax of 4.0 (95% CI: 3.5-4.6, I2&#x2005;=&#x2005;32%, P&#x2005;=&#x2005;0.23), 18F-FDG PET identified asymptomatic cartilage involvement in more than 25% patients and PET parameters correlated well with inflammatory markers. It had a higher positivity rate for inaccessible sites, such as peripheral airways, and was crucial in treatment monitoring. The pooled PET-positivity rate of 18F-FDG PET in relapsing polychondritis is high but requires prospective large-sample-size studies to explore the diagnostic accuracy and prognostic implications of 18F-FDG PET in relapsing polychondritis.

Polychondritis, Relapsing

Baseline Computed Tomography Coronary Angiography and Polygenic Risk Profiles in Adults With Type 2 Diabetes: A Cross-Sectional Analysis From the VOLTAIRE Study.

AIMS: To characterise baseline clinical, anatomical, and genetic cardiovascular risk profiles in participants enrolled in the VOLTAIRE (Evaluation of Polygenic Scores and CT Imaging in Risk Factor Modification in Patients with Type 2 Diabetes) study and examine concordance across these domains. METHODS: This analysis included adults with T2D who completed baseline computed tomography coronary angiography (CTCA) and polygenic risk score (PRS) assessment prior to randomisation in the VOLTAIRE study. Coronary atherosclerosis was evaluated using coronary artery calcium (CAC) score and CTCA-derived stenosis severity. Clinical risk was assessed using the New Zealand Society for the Study of Diabetes 5-year cardiovascular risk calculator. Polygenic risk for coronary artery disease was assessed using a genome-wide PRS and categorised into tertiles. RESULTS: Among 126 participants with T2D (mean age 57.5&#x2009;&#xb1;&#x2009;8.7&#x2009;years; 62.7% male), coronary atherosclerotic burden was highly heterogeneous: 34.9% had CAC&#x2009;=&#x2009;0, whereas 19.8% had CAC &#x2265;&#x2009;400. Moderate-to-severe coronary stenosis (&#x2265;&#x2009;50%) was present in 40.5% of participants overall, including 20.4% of those classified as low clinical risk. PRS distribution was variable (low 37.3%, intermediate 35.7%, high 27.0%). Overlap between anatomical, genetic, and clinical domains&#xa0;was limited, with only 8.7% of participants classified as high risk across all three. CONCLUSIONS: Substantial heterogeneity and limited overlap&#xa0;exist between anatomical, genetic, and clinical cardiovascular risk measures in T2D. These findings support a multimodal approach to risk assessment integrating imaging and genetic profiling. TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov; ID: NCT07091162.

Aged

Comprehensive assessment of vasospastic angina using coronary computed tomography angiography: synergistic value of the presence of myocardial bridge, perivascular inflammation, and myocardial extracellular volume fraction.

AIMS: Coronary computed tomography angiography (CCTA) has evolved beyond anatomical assessment to include sophisticated tissue characterization. While an elevated perivascular fat attenuation index around the right coronary artery (FAI-RCA) is known to reflect coronary inflammation in vasospastic angina (VSA), recurrent vasospasms may also induce chronic subclinical myocardial injury and subsequent remodelling, potentially associated with an increased myocardial extracellular volume fraction (ECV). However, the diagnostic integration of ECV and FAI-RCA for identifying VSA in patients with angina with non-obstructive coronary arteries (ANOCA) remains to be elucidated. METHODS AND RESULTS: This study included consecutive ANOCA patients who underwent CCTA with a dedicated ECV protocol, followed by an invasive spasm provocation test. Comprehensive CCTA analysis quantified both FAI-RCA and the transmural ECV gradient (the difference between endocardial and epicardial ECV: ECVEndo - ECVEpi). Of the 100 patients analysed (mean age: 65.3 &#xb1; 11.8 years; 55% male), 27 were diagnosed with VSA. Multivariable logistic regression analysis identified transmural ECV gradient [odds ratio (OR): 1.12, 95% confidence interval (CI): 1.01-1.25], presence of myocardial bridging (MB) (OR: 3.49, 95% CI: 1.25-9.74), and high FAI-RCA (> -70.95 Hounsfield units [HU]) (OR: 5.79, 95% CI: 2.06-16.30) as significant independent predictors of VSA (all P < 0.05). Notably, the integration of transmural ECV gradient provided incremental diagnostic value beyond FAI-RCA and MB, as assessed by the Net Reclassification Improvement and Integrated Discrimination Improvement. CONCLUSION: A multi-parametric CCTA approach potentially identifies patients at high risk for VSA. The significant association of the transmural ECV gradient with VSA suggests that myocardial remodelling imaging provides a novel diagnostic window into the cumulative myocardial impact of vasospasm, independent of active adipose tissue inflammation and the presence of MB.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I&#xb2;=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I&#xb2;=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50&#xa0;min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8&#xa0;min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Humans

The prevalence of isthmic and degenerative lumbar spondylolisthesis: an analysis of 1376 patients.

INTRODUCTION: Typically, spondylolisthesis is an asymptomatic spinal condition that is often captured accidently in radiographic studies. The limited studies reviewing incidence primarily used lateral radiographs, which lack the granularity of advanced imaging. In response, computed tomography (CT) has been recommended to enhance the accuracy of spondylolisthesis diagnosis (degenerative versus isthmic). In the present study, we sought to determine the prevalence of isthmic and degenerative spondylolisthesis using CT imaging. METHODS: We conducted a retrospective study of 1,680 patients who underwent abdominal/pelvic CT scans at a single level-1 trauma center from January 1, 2017, to January 31, 2017. RESULTS: A total of 1,680 CT scans were screened, of which 1,376 patient scans met the inclusion criteria of having undergone complete imaging (axial and sagittal images). The average age of the study population was 57.1 (standard deviation, 18.7) years; 51.1% were female, and 83.2% were Caucasian. The prevalence of isthmic spondylolisthesis was 5.4% (n&#xa0;=&#xa0;71): 3.6% of cases were at the L5-S1 level, 2.1% were at the L4-L5 level, and 0.6% were at the L3-L4 level. The female-to-male ratio was 0.73:1. The prevalence of degenerative spondylolisthesis was higher at 21.5% (n&#xa0;=&#xa0;285), and the level most commonly affected was L4-L5 (11.8%), followed by L5-S1 (9.7%) and L3-L4 (4.6%). The female-to-male ratio was 1.3:1. There was a higher prevalence of degenerative spondylolisthesis in women at L4-L5 (51.2% vs. 35.6%; P&#xa0;<&#xa0;0.001). CONCLUSION: We found that degenerative spondylolisthesis was more prevalent, occurring primarily in older women, between the L4-L5 vertebrae. On the other hand, isthmic spondylolisthesis more commonly occurred within male patients between the L5-S1 vertebrae. Our study is one of the first to recognize a high rate of degenerative spondylolisthesis within the L5-S1 region, highlighting the utility of CT scan to visualize spinal translation. LEVEL OF EVIDENCE: IV.

Humans

CT-Derived pelvic morphometry for preoperative risk assessment of recurrent unilateral inguinal hernia.

BACKGROUND: Recurrent inguinal hernia remains a significant challenge in abdominal wall surgery despite advances in mesh-based repair techniques and minimally invasive approaches. Although pelvic skeletal morphology has been implicated in inguinal hernia development, its association with recurrent disease remains incompletely understood. This study aimed to evaluate computed tomography (CT)-derived pelvic morphometric parameters and investigate their potential value in preoperative recurrence risk assessment. METHODS: This retrospective study included 251 male patients with preoperative abdominal CT examinations and complete clinical records who underwent elective inguinal hernia repair at a tertiary referral center. After applying the predefined eligibility criteria, 188 patients with unilateral inguinal hernias constituted the primary study cohort, including 162 primary and 26 recurrent unilateral hernias. The Radoievitch angle and Ami's line were measured independently by two blinded radiology residents using a standardized CT-based pelvic morphometric measurement protocol, and the mean values were used for analysis. Multivariable logistic regression and receiver operating characteristic (ROC) curve analyses were performed to evaluate the association between pelvic morphometric parameters and recurrent inguinal hernia. RESULTS: Patients with recurrent unilateral inguinal hernias demonstrated significantly greater affected-side Ami's line measurements (8.27&#x2009;&#xb1;&#x2009;0.63 vs. 7.90&#x2009;&#xb1;&#x2009;0.71&#xa0;cm, p&#x2009;=&#x2009;0.014) and larger Radoievitch angles (40.68&#x2009;&#xb1;&#x2009;4.02&#xb0; vs. 38.80&#x2009;&#xb1;&#x2009;3.68&#xb0;, p&#x2009;=&#x2009;0.018) than patients with primary unilateral hernias. Both the Radoievitch angle (OR 1.14, 95% CI 1.01-1.28, p&#x2009;=&#x2009;0.033) and Ami's line (OR 2.26, 95% CI 1.14-4.49, p&#x2009;=&#x2009;0.020) remained independently associated with recurrent inguinal hernia after adjustment for age and body mass index. ROC analysis demonstrated modest discriminatory performance (AUC 0.634 for the Radoievitch angle and 0.633 for Ami's line), while the multivariable model incorporating age, body mass index, and Ami's line showed slightly improved discrimination (AUC 0.655). CONCLUSION: CT-derived pelvic morphometric parameters were independently associated with recurrent unilateral inguinal hernia. Although their individual discriminatory performance was modest, standardized CT-based pelvimetry may serve as an objective adjunctive tool for individualized preoperative recurrence risk assessment in patients who already undergo CT imaging for unrelated clinical indications. Prospective multicenter studies are warranted to validate these findings and determine their clinical applicability.

Humans