Search PubMedSearch

PubMed · 42696224

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Abstract

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I²=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I²=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50 min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8 min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Explore related subjects

Keep this discovery

BibTeXRIS

Atef A Hassan, Mohamed Mostafa El Sheikh, Amr A Hassan, Abdelrahman Mady, Mohab Hesham, Yousef Mohamed Hamroush, Shimaa Mostafa Elnahas Wahdan, Mustafa M Kaff, Mohamed Ashraf Abd El Moniem, Mona Ibrahim Ahmed. 2026-09-04. Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.. https://doi.org/10.1007/s11701-026-03867-8

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Novel non-contrast computed tomography parameters for predicting spontaneous stone passage and surgical requirement in ureteral stones: The role of ureteral wall thickness and dilatation ratio.

We investigated the predictive value of standard non-contrast computed tomography (NCCT) measurements, the ureteral dilatation ratio (DDR) and intraluminal urine stasis markers, for spontaneous stone passage (SSP) versus surgical intervention in patients with ureteral stones. We also evaluated ureteral wall thickness (UWT) as a practical clinical marker. This retrospective study included 461 patients diagnosed with ureteral stones via NCCT. Patients were categorised into two groups based on clinical outcomes: the spontaneous passage group (MET; n&#x2009;=&#x2009;229) and the endoscopic surgery group (URS; n&#x2009;=&#x2009;232). Stone volume, stone density (HU), UWT, DDR and intraluminal urine attenuation values were measured for all patients. Independent risk factors were identified using a multivariate logistic regression model and clinical cut-off values were determined via ROC curve analysis. Stone volume, density, UWT and hydronephrosis grade were all significantly higher in the URS group. Multivariate regression analysis revealed that increased UWT (OR: 5.03, 95% CI: 3.66-6.90; p&#x2009;<&#x2009;0.001) was the strongest independent predictor of surgery. Higher DDR (OR: 1.88; p&#x2009;=&#x2009;0.003), advanced hydronephrosis, stone volume, and density also increased surgical risk. A UWT cut-off &#x2265;&#x2009;2.97&#xa0;mm predicted surgery with 84.8% sensitivity and 84.3% specificity (AUC: 0.872). A DDR cut-off >&#x2009;1.79 yielded 81.7% specificity and 40.4% sensitivity. UWT weakly correlated with stone volume (r&#x2009;=&#x2009;0.145), indicating wall thickening reflects an inflammatory response rather than a mere mechanical consequence. UWT is a superior predictor of SSP failure, supported by increased DDR as a highly specific complementary risk factor. These parameters could help clinicians to identify patients who would benefit from early surgical counselling and intervention rather than prolonged conservative management.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Volumetric bone marrow cellularity (VBMC) assessment from routinely processed trephines using three-dimensional x-ray histology and gaussian peak modelling.

Objective.Bone marrow cellularity is routinely estimated from a small number of two-dimensional histology sections, making assessment sensitive to section representativeness, processing artefacts and observer interpretation. Three-dimensional (3D) x-ray histology (XRH), using x-ray computed microtomography (&#xb5;CT), enables non-destructive whole-block imaging of trephine biopsies. This study evaluated whether XRH combined with Gaussian peak modelling could provide a pragmatic whole-block volumetric bone marrow cellularity (VBMC) estimate from formalin-fixed paraffin-embedded (FFPE) trephine biopsy blocks.Approach.Six routinely processed FFPE bone marrow trephine blocks were imaged using &#xb5;CT-based XRH at &#x223c;15 &#xb5;m spatial resolution. VBMC was defined as the red-marrow (RM) fraction of the marrow soft-tissue compartment, RM/(RM + intra-biopsy wax), with wax serving as the volumetric proxy for adipocyte/yellow marrow space. Whole-volume greyscale histograms were modelled using a three-peak Gaussian approach representing intra-biopsy wax, RM and demineralised trabecular matrix. Peak-height and area-under-the-curve metrics were compared with whole-volume 3D segmentation and clinical two-dimensional (2D) cellularity estimates.Main Results.Gaussian peak modelling successfully approximated the segmented tissue-phase distributions. The peak-height-derived VBMC metric showed the closest agreement with whole-volume 3D segmentation, with an average absolute percentage difference of 9.3%, compared with 18.6% for clinical expert 2D cellularity estimates. The area-under-the-curve metric followed similar trends but consistently overestimated VBMC. Clinical 2D cellularity broadly followed whole-biopsy trends but showed one discordant case not explained by slice-position sampling alone. XRH also enabled unrestricted virtual reslicing and visualisation of sectioning-associated artefacts prior to further microtomy.Significance.Pre-sectioning XRH combined with Gaussian peak modelling provides a rapid, segmentation-free route to volumetric cellularity estimation from intact clinical FFPE trephine blocks. The approach supports objective whole-biopsy assessment while remaining compatible with routine histopathology workflows, reflecting the expected limitations of section-based visual estimation despite its role as the current clinical standard. In the near term, it could provide a non-disruptive adjunct to conventional 2D cellularity reporting, pending larger validation studies.

Imaging, Three-Dimensional