Search PubMedSearch

PubMed · 42586150

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Abstract

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Explore related subjects

Keep this discovery

BibTeXRIS

Xiaohui Cheng, Yu Liu, Jun Li, Jianhua Ma, Yi Gao, Chenjie Zhou, Shulong Li. 2026-09-01. A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.. https://doi.org/10.1088/1361-6560%2Fae98dd

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and κ statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years ± 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (κ = 0.57-0.96) and clinical T categorization (κ = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (κ = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. © RSNA, 2026 Supplemental material is available for this article.

Humans

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures