Search PubMedSearch

SEARCH · Search PubMed

Results for “Risk quantification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

860 recordsLinked to original sources

Toward real-time quantification of driving risks: a systematic review and research agenda of risk field theory.

In complex traffic systems, driving risk often evolves in a continuous and progressive manner prior to crash occurrence. How to effectively represent and analyze such latent risk states remains a central challenge in traffic safety research. In recent years, risk field-based approaches have introduced spatial and spatiotemporal continuous modeling paradigms, providing new perspectives for characterizing the distribution of traffic risk and its dynamic evolution. Motivated by the rapid growth of this research area and the lack of a systematic synthesis, this paper presents a comprehensive review of studies applying risk field theory to driving safety and traffic risk analysis. Following the PRISMA guidelines, relevant literature was collected through multi-database searches and analyzed using a combination of bibliometric analysis and qualitative review. The review systematically summarizes the theoretical foundations, modeling elements, data sources, analytical methods, and application domains of risk field-related research. Particular attention is given to studies that conceptualize traffic risk as a continuous field, complemented by a broader review of traffic risk factor literature to identify key elements and analytical dimensions involved in risk field modeling. On this basis, the paper synthesizes research progress in major application areas, including traffic safety state representation, driving behavior analysis, traffic conflict assessment, and autonomous driving and human-machine cooperative systems. Differences and commonalities among existing studies are compared in terms of modeling strategies, data support, and application scenarios. Through this systematic review, the paper clarifies the main research themes and methodological trends of risk field-based studies, providing a structured framework for understanding the evolution and application of this approach and offering methodological insights for risk perception modeling and safety-oriented decision support in intelligent transportation systems (ITS).

Humans

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000 nM. However, due to carry-over observed at 10,000 nM, the validated calibration range was established at 1-2000 nM, with matrix-dependent LLOQs of 1-10 nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50 μM, and intracellular concentrations and cell viability were monitored over 48 h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Accurate quantification of canine mitochondrial DNA copy number from canine blood and brain samples.

Acute brain injury is difficult to evaluate in veterinary medicine and tools to investigate the potential involvement of mitochondrial involvement are limited. The brain is highly enriched in mitochondria and contains thousands of copies of mitochondrial DNA (mtDNA) per cell, but robust methods for quantifying mitochondrial DNA copy number (mtDNA-CN) in canine tissues are lacking. We describe the development of a quantitative real-time PCR assay for absolute measurement of mtDNA-CN which was validated in canine blood and brain tissue. To minimize amplification of nuclear mitochondrial insertion sequences (NumtS) and repetitive regions, species-specific oligonucleotide primers were designed following in silico genomic filtering. The assay was applied to a small pilot cohort comprising blood samples from dogs with and without acute brain injury (n = 4-6 per group) and cerebral cortex samples (n = 1 per group) to assess feasibility and biological plausibility. In non-brain injury dogs, blood mtDNA-CN ranged from 98 to 288 copies per nuclear genome (mean 193 ± 72), while values in brain-injured cases ranged from 163 to 228 copies per genome (mean 200 ± 33). Cerebral cortex samples exhibited higher mtDNA-CN than blood, consistent with known tissue-specific mitochondrial enrichment. In a single brain-injured case with serial sampling, mtDNA-CN increased over five days. This study presents a validated assay and pilot data for mtDNA-CN quantification in canine samples. While not powered for biomarker evaluation, this method may enable future studies of mitochondrial dynamics in canine brain injury and metabolic disease.

Animals

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Thermal analysis techniques for microplastic mass quantification: Methodological challenges and standardization needs.

Microplastics (MPs, 1 &#x3bc;m-5 mm) and nanoplastics (NPs, <1&#x202f;&#x3bc;m) are ubiquitous contaminants requiring standardized quantification methods. This systematic review evaluates thermal analysis techniques for mass-based MP detection, including pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), thermogravimetry-MS (TGA-MS), thermal extraction desorption-GC-MS (TED-GC-MS), and differential scanning calorimetry (DSC). Database searches (Web of Science, from inception to December 1, 2025) following PRISMA guidelines identified studies across seven environmental matrices (water, soil/sediment, atmosphere, biota, human tissues). We identify critical standardization gaps: inconsistent marker ion selection, unvalidated conversion factors for tire and road wear particles (TRWPs), and the absence of certified reference materials for complex matrices. Py-GC-MS demonstrates versatility but suffers from lipid interference in biological samples; TED-GC-MS offers superior sensitivity (sample capacity &#x223c;200&#xd7; Py-GC-MS) but lacks real-time chromatographic monitoring. To advance data comparability, we propose: (i) harmonized ion selection hierarchies based on specificity-sensitivity balance, (ii) matrix-specific TRWP quantification protocols, and (iii) inter-laboratory validation using environmental reference materials. This review provides a methodological roadmap for standardizing thermal analysis in MP research.

Humans

ZrO&#x2082;@C-based colorimetric/photothermal dual-mode immunosensor coupled with a novel monoclonal antibody for quantification of Aspergillus ochraceus biomass.

Aspergillus ochraceus contaminates agricultural products and produces nephrotoxic, carcinogenic ochratoxin A (OTA), posing severe food safety hazards. A dual-signal lateral flow immunochromatographic assay (dLFIA) based on ZrO&#x2082;@C nanoprobes was established for quantitative detection of A. ochraceus biomass. A novel monoclonal antibody (mAb 4B4) was prepared as the capture antibody to immobilize A. ochraceus mycelial lysate antigen on the test line, and a rabbit polyclonal antibody (pAb G2801) as the detection antibody to modify ZrO&#x2082;@C composites (synthesized via UiO-66 pyrolysis) into 200&#xa0;nm colorimetric/photothermal nanoprobes. This dLFIA achieved limits of detection of 0.164&#xa0;&#x3bc;g/mL (colorimetric) and 0.517&#xa0;&#x3bc;g/mL (photothermal). This efficient and reliable method allows quantitative analysis of A. ochraceus biomass, which is suitable for routine monitoring of fungal contamination in agro-food matrices.

Antibodies, Monoclonal

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54&#xa0;nM (S/N&#xa0;=&#xa0;3) within a linear range of 0.2-12&#xa0;&#x3bc;M. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000&#xa0;ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Quantification of appetite-regulating hormones in children with hypothalamic and common obesity.

CONTEXT: The pathophysiology of hypothalamic obesity (HyOb) remains incompletely understood with no effective treatments. OBJECTIVE: We examined differences in appetite-regulating hormone concentrations between patients with HyOb, common obesity, and lean controls. DESIGN: Multiway cross-sectional case-control study of patients aged 2 through 19 years. SETTING: Two tertiary pediatric endocrinology centers. PATIENTS: Cases were obese (body mass index [BMI] > +2 SD score [SDS], "HyOb") and lean ("HyLean") patients with congenital (septo-optic dysplasia) or acquired (suprasellar brain tumor) hypothalamic disorders. Controls had common obesity ("Ob") or nonhypothalamic disorders and normal BMI ("Lean"). MAIN OUTCOME MEASURES: Relationships between the Dykens' Hyperphagia Questionnaire Score (DHQS), plasma or serum concentrations of leptin, insulin, &#x3b1;-melanocyte stimulating hormone (&#x3b1;MSH), brain-derived neurotrophic factor, oxytocin, acylated ghrelin, agouti-related peptide and copeptin, and BMI SDS. RESULTS: Dykens' Hyperphagia Questionnaire Score did not differ between HyOb and Ob patients (24 [17-34] vs 24 [18-31]) but correlated with BMI SDS in patients with hypothalamic disorders (P = 0.02). HyOb and Ob patients exhibited similarly increased anorexigens (insulin, leptin) and decreased orexigens (ghrelin, agouti-related peptide) compared to HyLean and Lean patients. The rate of BMI increase was independently associated with lower &#x3b1;MSH (&#x3b2; = -0.23 [-0.36 to -0.11], P = .0007) and ghrelin (&#x3b2;=-0.004 [-0.01 to 0.00], P = .001) concentrations, suggesting that &#x3b1;MSH replacement may be a therapeutic target for HyOb. HyLean patients demonstrated intermediate insulin responses to glucose compared to other subcohorts. CONCLUSION: In our cohort, patients with HyOb appeared indistinguishable from Ob in terms of their appetite and appetite-regulating neuroendocrine circuitry. Higher &#x3b1;MSH concentrations are associated with reduced weight gain and may be a target for therapeutic intervention.

alpha-MSH

Assay-dependent variability in peptide biomarker quantification: experimental evidence from renalase in chronic kidney disease.

BACKGROUND: Renalase is a promising biomarker for kidney disease, but published levels vary widely between studies. We hypothesised that variability in commercial enzyme-linked immunosorbent assays (ELISAs) kits and matrix effects (serum vs plasma) drive these inconsistencies. METHODS: Paired serum and plasma samples from 56 participants (28 chronic kidney disease (CKD) stages 2-5, 28 healthy controls) were tested using three commercial renalase ELISAs (BTLAB, Cloud-Clone, EIAab). We assessed intra-assay precision, inter-assay agreement (Spearman's rank correlation and Bland-Altman analysis on log10-transformed values), matrix effects, and associations with estimated glomerular filtration rate (eGFR). Diagnostic performance was evaluated by Receiver operating characteristic (ROC) analysis. RESULTS: Inter-assay renalase concentrations differed markedly (up to orders of magnitude), with weak inter-assay correlations (r&#x2009;&#x2264;&#x2009;0.25). Bland-Altman analyses revealed large, systematic biases between kits. Only the BTLAB assay showed consistent serum/plasma agreement, a significant correlation with eGFR (&#x3c1;&#x2009;&#x2248;&#x2009;0.32-0.42, p&#x2009;<&#x2009;0.05), and moderate discriminatory performance for CKD in serum (AUC = 0.70) and plasma (AUC = 0.68). Cloud-Clone and EIAab produced divergent results and strong matrix-dependent biases. CONCLUSIONS: Observed variability among commercial ELISA platforms may compromise comparability between studies. Harmonisation, standardised reference materials, and cross-validation are necessary before renalase assays can be used reliably in clinical practice.

Humans

Artificial intelligence-derived myocardial fibrosis on cardiac magnetic resonance for prognosis in cardiomyopathy: A systematic review of a sparse evidence base.

BACKGROUND: Myocardial fibrosis on cardiovascular magnetic resonance (CMR), assessed by late gadolinium enhancement (LGE) and parametric mapping, is an established predictor of adverse events in cardiomyopathy. We assessed whether artificial intelligence (AI) quantification of fibrosis adds independent prognostic value. METHODS: We searched six databases, a clinical-trials register, and a preprint server from inception to 13 June 2026. Eligible studies used AI to generate a fibrosis marker in adults with ischemic or nonischemic cardiomyopathy, with covariate-adjusted outcomes over &#x2265;12 months. Risk of bias was assessed using PROBAST, PROBAST+AI, and QUIPS. Fewer than three comparable studies precluded meta-analysis; certainty was rated using GRADE. RESULTS: Of 448 records (381 after de-duplication), 18 full texts were reviewed and two included, one peer-reviewed and one preprint. In an ischemic-cardiomyopathy registry (Ghanbari et al.; n = 216 analytic, 26 events), AI-derived dense LGE scar predicted arrhythmic events (univariable hazard ratio [HR] 2.35, 95% CI 1.33-4.15), and AI-derived but not manual scar improved discrimination beyond guideline criteria (area under the curve 0.63 to 0.68; p = 0.02). In a nonischemic dilated-cardiomyopathy preprint (Kim et al.; n = 347, 119 events), automated extracellular volume &#x2265;30% predicted cardiovascular death or heart-failure hospitalization (adjusted HR 2.00, 95% CI 1.32-3.03). Both were at high risk of bias, with data-derived thresholds and no external validation. CONCLUSIONS: Across only two studies, AI-derived fibrosis was independently associated with adverse cardiovascular events, but its added value over manual quantification remains unproven. Certainty was very low. The evidence base is sparse and not yet ready for clinical use.

Humans

Meta-analysis of growth and inactivation kinetics of Legionella.

Quantitative risk assessments intended to inform evidence-based water management plans and public health targets for Legionella in engineered water systems are constrained by fragmented and heterogeneous growth and inactivation kinetics. We conducted a meta-analysis of 25 growth and 39 thermal- and chemical-inactivation studies, fitting microbial persistence models to harmonize parameters. Nonlinear models outperformed first-order formulations, indicating that lag phases and resistant or protected subpopulations are central to Legionella persistence. Random forest analysis identified environmental and methodological drivers of variability based on 226 growth rates and reduction times for thermal (209) and chemical (135) inactivation. Growth was primarily governed by temperature, nutrient availability, and compatible Legionella-host pairings; thermal inactivation by quantification method, temperature, and turbidity; and chemical inactivation by inoculum size, disinfectant type, concentration, and host-associations. Accordingly, temperature-dependent growth parameters and exposure metrics for heat, free-chlorine, and monochloramine, expressed as TT (Temperature&#xd7;time) and CT (Concentration&#xd7;time), were derived as condition-specific inputs for predictive models. Growth optima around 37-40 &#xb0;C, together with lag-time estimates, indicate that hot-water temperature setbacks and energy-saving practices may favor Legionella proliferation under repeated or prolonged lukewarm exposure. Culture- and viability-based TT differences highlight the need to consider viable&#x2011;but-non-culturable persistence in monitoring programs. CT comparisons suggest monochloramine may be advantageous because of its lower apparent sensitivity to host-associated protection. Although limited by restricted experimental conditions, the findings show that predictive models should account for microbial ecology, water matrix effects, and quantification endpoints. Future kinetic studies should prioritize realistic multi-host systems, strain pre-adaptation, complementary viability measurements, and standardized protocols and reporting to ensure reproducibility and enable robust system-level predictive modeling.

Legionella

Longitudinal Prediction of Retinal Sensitivity Based on Disease Progression Quantified From Optical Coherence Tomography in Geographic Atrophy.

PURPOSE: The purpose of this study was to analyze the association between disease progression of geographic atrophy (GA) from optical coherence tomography (OCT) with retinal sensitivity (RS) in microperimetry (MP) over a 2-year follow-up period. METHODS: This is a longitudinal analysis of the OAKS Phase-III clinical trial. Both study and fellow eyes with GA that underwent imaging with the Spectralis OCT and consecutive MP examination were eligible. Pointwise quantification of ellipsoid zone (EZ) thickness, EZ and retinal pigment epithelium (RPE) loss from OCT volumes was correlated with localized RS. A longitudinal predictive model using a Markov Chain framework was implemented to predict RS change over time based on OCT biomarkers. The modeling of morphological and functional progression was based on the fellow-eye cohort. RESULTS: A total of 39,681 MP points from 406 patients were analyzed. In the fellow eye cohort, baseline (BSL) EZ thickness was positively associated with RS (0.3 decibel [dB]/&#xb5;m, P < 0.001). Decrease in EZ thickness between visits during follow-up was significantly associated with decrease in RS (0.1 dB / 1&#xa0;&#xb5;m change). RS was significantly lower in MP points within EZ loss during follow-up compared with MP points within the retina with measurable EZ (P < 0.001). The largest functional decline was observed within RPE loss, also associated with the highest probability of absolute scotoma (P < 0.001). Morphological progression to EZ and RPE loss was influenced by EZ thickness and the morphology of adjacent MP points (P < 0.001). CONCLUSIONS: Two exploratory endpoints were developed, namely quantification of EZ thickness and loss, and localized RS within high-risk OCT areas. RS decline during follow-up is associated with automatically quantified disease progression in OCT.

Humans

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Measuring economic efficiency in adult intensive care units: A systematic review of methods, metrics, and evidence.

OBJECTIVES: Intensive care units (ICUs) consume substantial hospital resources, yet "efficiency" is inconsistently defined and measured. This study systematically reviewed how economic efficiency has been conceptualised and quantified in adult ICUs and appraised the quality of evidence. METHODS: Following PRISMA 2020 and a PROSPERO-registered protocol (CRD420251107866), we searched MEDLINE, Embase, CINAHL, Cochrane Library and Web of Science (2000-August 2025), plus global grey sources. Eligible studies explicitly defined efficiency and reported an efficiency metric/model linking ICU inputs (e.g., staff, beds/capacity, time, consumables, or costs) to outputs/outcomes (e.g., throughput/discharges, length of stay/resource use, risk-adjusted mortality). Dual independent screening and extraction were performed. Study quality was appraised using MMAT, and findings were synthesised narratively (SWiM), given heterogeneity. RESULTS: 39 studies (2001-2025) from 17 countries were included, all from high-income or upper-middle-income settings. Four methodological families were identified: (1) frontier modelling (predominantly DEA; occasional SFA/RFDH), (2) benchmarking indicators (risk-adjusted mortality and LOS/resource-use ratios; "efficiency matrix" quadrant classification), (3) cost-outcome evaluations, and (4) operational/process metrics. Across families, variation in decision-making units, input/output selection, and risk adjustment limited comparability; long-term and patient-reported outcomes were absent, and equity considerations were uncommon. CONCLUSIONS: ICU efficiency research is feasible but fragmented and often methodologically limited. Standardised definitions, validated risk adjustment, uncertainty quantification, and inclusion of patient-centred and equity-relevant outcomes are needed before efficiency metrics can reliably inform value-based decision making.

Intensive Care Units

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

A systematic review and meta-analysis of the late positive potential and internalizing psychopathology.

The present study leveraged the Hierarchical Taxonomy of Psychopathology (HiTOP) framework to conduct a systematic meta-analysis to determine the association between the late positive potential (LPP) index of emotional reactivity and internalizing psychopathology. PRISMA guidelines were followed. Articles were identified through PubMed, APA PsycInfo, and Web of Science online platforms in May 2025. Included articles examined associations between the LPP to positive and/or negative stimuli and internalizing psychopathology. Risk of bias and publication bias were assessed. Results were examined for individual disorders, distress and fear subfactors, and the internalizing spectrum using two approaches: standard analyses that examined aggregate effects and hierarchical analyses that examined direct and indirect relationships. We conducted moderator analyses for sample, task design, LPP quantification, and psychopathology measurement. We included 63 studies across 5,360 participants (Mage = 19.65, SD = 11.1; 58.7% female). In standard meta-analyses, depression was associated with a smaller LPP to positive stimuli (r = -.06, 95% confidence interval [CI; -.12, -.003]). Specific phobia was associated with a larger LPP to negative stimuli (r = .21, 95% CI [.02, .37]). Distress was associated with a smaller LPP to both positive (r = -.12) and negative (r = -.11) stimuli when measured via clinical interview, and fear was associated with a larger LPP to negative stimuli (r = .10, 95% CI [.03, .16]). Hierarchical analyses indicated that the depression results were specific to the disorder, whereas the fear disorder-level results were due to the higher order fear subfactor. The LPP demonstrates discriminant relationships with distress and fear disorders and subfactors. Results were largely robust against methodological factors. (PsycInfo Database Record (c) 2026 APA, all rights reserved).

Humans