Water intake, switching between bites and sips, and drinking behavior are associated with food intake across meals varying in spiciness: A secondary analysis of two randomized crossover studies.

Widespread nutrition advice instructs consumers to drink water with meals to increase fullness and reduce energy intake. However, recent data indicates greater water intake is associated with more food intake at a meal, not less. Switching between meal components (e.g., alternating between food and water), has also been associated with increased food intake at a pasta meal, but it remains unclear whether this applies to other foods. In a secondary analysis, we pooled existing data from 2 crossover experiments (total n&#xa0;=&#xa0;86) where adults ate an ad libitum lunch consisting of 650&#xa0;g of beef chili (n&#xa0;=&#xa0;52) or chicken tikka masala (n&#xa0;=&#xa0;34) with 450&#xa0;g of water twice in the laboratory while being video-recorded. For both experiments, the spiciness of the lunch was varied by adding different ratios of hot:sweet paprika. Videos were coded to measure sip number, sip size (g/sip), drinking rate (g/min), and number of switches between bites of food and sips of water. As we previously reported, increasing spiciness slowed eating rate and reduced food intake; in secondary analyses described here, the reduction in food intake was not moderated by water intake, switching, or drinking behaviors (all p&#xa0;>&#xa0;0.73). Notably, across all meals, greater water intake (p&#xa0;<&#xa0;0.001) and switching (p&#xa0;=&#xa0;0.02) associated with greater food intake. Overall, individuals ate more when they drank more and switched between bites and sips more often, highlighting the potential influence of water and drinking behaviors on food consumption. This finding challenges the widespread dietary advice to drink water with meals to reduce food intake.

Humans

Infertility treatment in women with epilepsy: A systematic review.

BACKGROUND: The impact of assisted reproductive technologies (ART) on seizure control in women with epilepsy remains incompletely understood. METHODS: A systematic review was conducted according to PRISMA guidelines. EMBASE, MEDLINE, CINAHL, Scopus, and the Cochrane Library were searched from inception to March 2025. Eligible studies included observational studies and case-based reports involving women undergoing infertility treatment. RESULTS: A total of 1216 publications were identified, of which four studies met the inclusion criteria, including case reports, a case series, and a cohort study. These studies included 16 women aged 25-46&#xa0;years undergoing infertility treatment, all but one of whom had epilepsy. Interventions involved in vitro fertilization (IVF), ovulation induction, and hormonal therapies. Patients were treated with a range of antiseizure medications (ASMs), including carbamazepine, clobazam, lamotrigine, levetiracetam, oxcarbazepine, valproate, and zonisamide, either as monotherapy or in combination. Seizure frequency was generally stable, with most patients maintaining baseline seizure control. Seizure exacerbations were uncommon and primarily associated with hormonal therapy and reduced ASM levels, particularly reduced lamotrigine levels. Reported events included breakthrough seizures in the setting of decreased lamotrigine concentrations, seizure clusters associated with follitropin beta, and a new-onset seizure following dehydroepiandrosterone exposure. Across studies, multiple ART attempts resulted in live births with different ASM regimens, as well as in patients not receiving ASMs. CONCLUSION: Available evidence suggests that ART is feasible in women with epilepsy, with most patients maintaining stable seizure control. Hormonal therapy may affect ASM pharmacokinetics and seizure threshold, thereby warranting close monitoring. Larger prospective studies are needed to better define ASM-specific effects and optimize care.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Could the preoperative urethral curve be used to predict immediate urinary continence following Retzius-sparing robot-assisted radical prostatectomy? A retrospective multi-center study.

PURPOSE: Immediate urinary continence (UC) recovery following Retzius-sparing robot-assisted radical prostatectomy (RS-RARP) remains highly variable, highlighting the need for reliable preoperative prediction. We aimed to develop and validate models to identify patients likely to achieve immediate UC recovery following RS-RARP. MATERIALS AND METHODS: A total of 580 prostate cancer patients who underwent RS-RARP from four medical centers were assigned to a training set (n=348), an internal validation set (n=103) and an external validation set (n=129). Independent predictors were identified through univariate analysis and LASSO regression. A nomogram was constructed using multivariate logistic regression. Its performance was evaluated with receiver operating characteristic (ROC) curve, calibration curves, and decision curve analysis. RESULTS: Immediate UC recovery was observed in 84.5% (294/348) of patients in the training cohort, 80.6% (83/103) in the internal validation cohort, and 81.4% (105/129) in the external validation cohort, respectively. Multivariate analysis identified membranous urethral length (MUL) (OR=1.23, P=0.029) and urethral curvature (OR=2.84, P<0.001) as independent predictors, while prostate volume (PV) (OR=0.84, P <0.001) as a protective factor. The nomogram integrating MUL, PV, and urethral curvature demonstrated superior predictive accuracy, with an AUC of 0.87 (95% CI, 0.83-0.91) in the training cohort. The bootstrap-corrected calibration slope was 0.96, and the Brier score was 0.08.&#xa0;Calibration curves and decision curve analysis confirmed the predictive accuracy and clinical utility of the nomogram. CONCLUSIONS: Our study introduces a novel quantitative method for assessing urethral curvature. The mpMRI-based model, integrating urethral curvature and prostate spatial configuration, offers enhanced predictive accuracy for postoperative immediate UC recovery.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

The Effect of Robot-Assisted Gait Training on Balance, Gait and Kinesiophobia in Individuals With Post-Stroke Hemiparesis: A Randomized Controlled Trial.

BACKGROUND AND PURPOSE: Robot-assisted gait training (RAGT) is well established for post-stroke gait rehabilitation, but its potential effects on psychological and behavioral outcomes are less clear. This study investigated the effects of adding RAGT to conventional rehabilitation on balance, gait, kinesiophobia, and movement confidence in individuals with post-stroke hemiparesis. METHODS: This single-blind, parallel-group randomized controlled trial included 60 individuals with post-stroke hemiparesis (50-75&#xa0;years), randomly allocated to an RAGT group (n&#xa0;=&#xa0;30) or control group (n&#xa0;=&#xa0;30). Ethical approval was obtained from the Clinical Research Ethics Committee of Istanbul Yeni Y&#xfc;zy&#x131;l University (Approval No. 20.01.2022/05; approval date: 20 January 2022). Both groups received conventional rehabilitation for 8&#xa0;weeks; the RAGT group additionally received 24 sessions of RAGT. Kinesiophobia was a prespecified study outcome assessed using the Kinesiophobia Causes Scale (KCS); balance, gait, and balance confidence were also assessed. All 60 randomized participants completed follow-up and were analyzed in their assigned groups. RESULTS: Significant group&#xa0;&#xd7;&#xa0;time interactions were observed for several outcomes, including BBS, TUG duration, 10MWT walking speed, ABC, and KCS total score (p&#xa0;<&#xa0;0.05). The between-group difference in change for KCS total score was -0.36 (95% CI: -0.51 to -0.21; partial eta squared&#xa0;=&#xa0;0.292). In post hoc analyses adjusting each outcome for its baseline value, significant group effects remained for BBS, TUG duration, 10MWT walking speed, ABC, KCS biological domain, and KCS total score (p< = 0.031), whereas 10MWT step count and the KCS psychological domain were no longer statistically significant. DISCUSSION: Adding RAGT to conventional rehabilitation was associated with greater improvements in several balance, mobility, walking-speed, balance-confidence, and kinesiophobia outcomes compared with conventional rehabilitation alone. These findings suggest potential additional physical and psychological benefits of incorporating RAGT into post-stroke rehabilitation. However, because the RAGT group received greater overall treatment exposure, the observed between-group differences cannot be attributed solely to the robotic component. The principal contribution of this study is the concurrent evaluation of kinesiophobia and movement confidence alongside physical outcomes.

Aged

Gubernacular discontinuity and abnormal distal fixation in cryptorchidism: Challenging the classical concept.

BACKGROUND: The gubernaculum is essential for testicular descent, but its detailed surgical anatomy remains poorly understood. We have previously identified an unrecognized anatomy of the round ligament in female patients with sliding inguinal hernias. OBJECTIVE: This study investigated whether comparable anatomical features exist in the gubernaculum of male cryptorchidism patients, as compared to those identified in female sliding hernias. MATERIALS AND METHODS: We retrospectively analyzed undescended testes located in the inguinal canal that underwent open inguinal orchidopexy between 2016 and 2025. Laparoscopically managed nonpalpable testes and those with suprascrotal testes were excluded. To ensure consistent anatomical evaluation, a standardized surgical protocol supervised by the senior author was applied to all cases. Findings were verified using operative reports and video recordings. After dissecting the processus vaginalis along the internal spermatic fascia (transversalis fascia), the pars infravaginalis gubernaculi were exposed. The relationship between the plica gubernaculi and pars infravaginalis gubernaculi, as well as the site of distal gubernacular fixation, was assessed. RESULTS: A total of 64 undescended testes of 56 patients were included. Video recordings were available for 45 of these 64 testes (70%). A patent processus vaginalis was observed in 60 out of 64 testes (94%), while it was obliterated in two ascending testes and unknown in two. In all 64 testes (100%), the pars infravaginalis gubernaculi was not continuous with the plica gubernaculi, with the transversalis fascia interposed between them. This configuration closely resembled that described previously for sliding inguinal hernias in women. Distal gubernacular fixation was located lateral to the scrotum in 49 testes (77%), at the upper scrotal border in 14 testes (22%), and absent in one testis (1.6%). DISCUSSION: Cryptorchidism is associated with a previously unrecognized discontinuity of the gubernaculi and common abnormal distal gubernacular fixation. These findings challenge the conventional views on gubernacular invagination and suggest that abnormal distal fixation may contribute to failed testicular descent. The study was limited by its single-center, retrospective design, small sample size, and lack of a control group. CONCLUSION: This study identified a previously unrecognized discontinuity of the gubernaculi in cryptorchidism. These findings deepen the understanding of the pathophysiology of testicular descent.

Humans

First insights into the role of evolutionary history in shaping venom composition of Vipera ammodytes.

Understanding intraspecific venom variation requires distinguishing the contributions of neutral population history from natural selection. This study aims to determine whether venom variation in Vipera ammodytes species complex is structured across eight phylogenetic groups. Despite a complex evolutionary history, venom composition did not differ among phylogenetic groups within the analytical framework used, suggesting that shared ancestry alone does not explain venom variation. Whether local adaptation to environmental conditions explains the observed variation remains an open question for future studies.

Animals

Unanticipated Effects of Parental Social Media Use: Guidance for Clinicians.

"Sharenting," the practice of parents posting photographs, videos, and information about their children on social media, has an ever-growing presence in modern society. However, researchers and the public are now recognizing the potential consequences of sharing, including creation of permanent digital footprints, strained familial relationships, and threats to children's safety. Despite this emerging evidence, no U.S. clinical or legal guidelines exist for parents on safe sharing. Visits with behavioral health providers and family physicians can serve as key points for intervention. This column aims to provide clinicians with a better understanding of sharenting and its potential effects on patients and families, guidance on discussing safe online sharing, and a tool for parents and other caregivers to use when deciding whether to post.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Failure modes and effects analysis for clinical implementation of online adaptive radiotherapy: A systematic review.

BACKGROUND: The accuracy of radiotherapy is limited by anatomical variations occurring over time scales ranging from sub-seconds to days. Online Adaptive Radiotherapy (OART) addresses this by enabling daily plan adaptation based on real-time imaging. While OART offers improved dose conformity, its dynamic, time-constrained workflow introduces novel failure modes that challenge traditional quality assurance protocols. PURPOSE: This study aims to synthesize the existing literature on Failure Modes and Effects Analysis (FMEA) for OART to systematically catalog risks and identify mitigation strategies. METHODS: A systematic literature search was conducted to identify studies applying FMEA to OART workflows. Eleven studies were included, covering MR-guided (ViewRay MRIdian, Elekta Unity), CBCT-guided (Varian Ethos), and MR-enhanced C-arm linac systems. To address heterogeneity in risk scoring methodologies (e.g., TG-100 10-point scales vs. 5-point rankings), extracted failure modes were harmonized into a standardized three-tier risk classification system (Class I: Low, Class II: Intermediate, Class III: High). RESULTS: A total of 300 unique failure modes were identified, with 49.6 percent classified as high-risk (Class III). Analysis revealed that the majority of high-risk failures were concentrated in the online treatment delivery phase, specifically within human-computer interactions and anatomical contouring steps. CONCLUSIONS: This study supports the development of tailored, robust QA frameworks that prioritize human factors and process consistency to guide safe implementation in diverse clinical settings.

Humans

Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.

Accurate species-level identification within the genus Serratia remains challenging due to extensive phenotypic overlap and high genomic relatedness among closely related and recently described taxa. This study presents an evaluation of routine and genome-based identification approaches applied to clinical Serratia isolates, integrating phenotypic assays, MALDI-TOF MS (Bruker Daltonics), 16S rRNA gene sequencing, and Whole-Genome Sequencing (WGS). A total of 103 isolates collected from a teaching hospital were analyzed. WGS was performed on a subset of isolates. Conventional biochemical methods classified all isolates as Serratia marcescens, whereas MALDI-TOF MS identified 60.1% as S. marcescens, 11.6% as S. ureilytica, and 28.1% just at the genus level. Peak analysis from MALDI-TOF MS revealed specific peaks associated with S. marcescens and S. ureilytica, but limited discriminatory power. WGS of six isolates initially identified as S. ureilytica by MALDI-TOF MS revealed reclassification as Serratia sarumanii (n = 5) and Serratia montpellierensis (n = 1), supported by Average Nucleotide Identity (ANI), Average Amino Acid Identity (AAI), and Digital DNA-DNA Hybridization (dDDH) thresholds. In contrast, 16S rRNA analysis showed limited species-level resolution. Phylogenomic and SNP-based analyses confirmed these classifications with strong support. Overall, this study underscores the critical role of high-resolution genomic approaches for precise species identification and highlights the need for continuous expansion and curation of MALDI-TOF MS reference databases to support reliable clinical diagnostics and epidemiological surveillance of emerging Serratia species.

Spectrometry, Mass, Matrix-Assisted Laser Desorpti

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Robust optimisation for photon radiotherapy: A scoping review of models, paradigms, and reporting.

BACKGROUND AND PURPOSE: Robust optimisation offers an alternative to conventional margin-based photon radiotherapy planning by explicitly modelling uncertainty, but practice is variable and not standardised. MATERIALS AND METHODS: A scoping review was conducted to map robust optimisation for photon external beam radiotherapy. Electronic searches of Scopus, PubMed and Google Scholar (2000-2025, English language) identified planning studies that incorporated modelled uncertainties into the optimisation process and reported at least one robustness-related outcome. Data were charted on clinical context, uncertainty models, optimisation paradigms, robustness metrics and evidence for clinical implementation. RESULTS: Seventy-one studies were included. Most investigated prostate, breast or lung cancer and used intensity-modulated radiotherapy or volumetric-modulated arc therapy in commercial or research treatment planning systems. Scenario-based worst-case (minimax) optimisation was the dominant paradigm in clinically oriented work, while chance-constrained, conditional value at-risk, distributionally robust and adaptive formulations were confined to small methodological series. Uncertainty modelling focused mainly on rigid set-up error; fewer studies incorporated respiratory motion, inter-fraction anatomical change, dose-calculation uncertainty or biological variation. Robustness was evaluated with diverse scenario-based dose-volume metrics, probabilistic coverage measures, composite robustness indices and, less often, biological endpoints. Direct clinical implementation reports were scarce. CONCLUSION: Robust photon planning is technically feasible and generally maintains or improves target coverage and organ sparing compared with margin-based planning. However, heterogeneity in uncertainty models, optimisation configuration and robustness reporting limits comparison and synthesis. Pragmatic minimum standards are proposed to support future consensus and wider clinical adoption.

Humans