Search PubMedSearch

PubMed · 42660060

Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.

Abstract

Accurate species-level identification within the genus Serratia remains challenging due to extensive phenotypic overlap and high genomic relatedness among closely related and recently described taxa. This study presents an evaluation of routine and genome-based identification approaches applied to clinical Serratia isolates, integrating phenotypic assays, MALDI-TOF MS (Bruker Daltonics), 16S rRNA gene sequencing, and Whole-Genome Sequencing (WGS). A total of 103 isolates collected from a teaching hospital were analyzed. WGS was performed on a subset of isolates. Conventional biochemical methods classified all isolates as Serratia marcescens, whereas MALDI-TOF MS identified 60.1% as S. marcescens, 11.6% as S. ureilytica, and 28.1% just at the genus level. Peak analysis from MALDI-TOF MS revealed specific peaks associated with S. marcescens and S. ureilytica, but limited discriminatory power. WGS of six isolates initially identified as S. ureilytica by MALDI-TOF MS revealed reclassification as Serratia sarumanii (n = 5) and Serratia montpellierensis (n = 1), supported by Average Nucleotide Identity (ANI), Average Amino Acid Identity (AAI), and Digital DNA-DNA Hybridization (dDDH) thresholds. In contrast, 16S rRNA analysis showed limited species-level resolution. Phylogenomic and SNP-based analyses confirmed these classifications with strong support. Overall, this study underscores the critical role of high-resolution genomic approaches for precise species identification and highlights the need for continuous expansion and curation of MALDI-TOF MS reference databases to support reliable clinical diagnostics and epidemiological surveillance of emerging Serratia species.

Explore related subjects

Keep this discovery

BibTeXRIS

Ingrid Macedo Felício, Edgard Freitas Vianna, Mila Muraro Almeida, Jéssica Oliveira Abreu, Robson Souza Leão, Elizabeth Andrade Marques. 2026-08-23. Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.. https://doi.org/10.1016/j.diagmicrobio.2026.117624

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Comparative evaluation of molecular technologies for the identification of prevalent non-tuberculous mycobacteria in pulmonary infections: a systematic review and meta-analysis.

BACKGROUND: The increasing prevalence of non-tuberculous mycobacteria pulmonary disease (NTM PD) is a burden to public health. Successful management of NTM PD critically depends on accurate species identification and reliable drug susceptibility testing to guide appropriate antibiotic therapy. Emerging molecular technologies offer rapid diagnostic solutions compared to conventional methods, but their performance varies. This study aims to provide a comprehensive evaluation of current molecular techniques for NTM identification and to present a global antibiotic resistance profile. METHODS: A systematic literature search was conducted in PubMed and Web of Science for studies published between 2005 and 2024. Studies applying molecular methods for NTM identification and resistance detection in humans were included. Data on study characteristics, diagnostic methods, sample types, sample sizes, identification sensitivity, and drug susceptibility results were extracted. Meta-analysis was performed using R with the meta4diag package. The quality of included studies was assessed using the QUADAS-2 tool. RESULTS: The analysis included 49 studies on NTM identification and 33 studies on antibiotic resistance. For species identification, all evaluated molecular technologies (MALDI-TOF MS, PCR-based methods, Sequencing, DNA chip, and DNA strip) demonstrated high pooled sensitivities (>0.92). Subgroup analysis revealed that sample type significantly affected performance for MALDI-TOF MS. Preliminary analysis of antibiotic resistance rates revealed varying patterns. For slowly growing mycobacteria, a significantly high Ethambutol resistance rate was observed in M. avium (69.20%). Among rapidly growing mycobacteria, resistance to Imipenem was notable (54.22%), and Clarithromycin resistance varied significantly within the Mycobacterium abscessus complex. CONCLUSION: Emerging molecular technologies have revolutionized the methodology for NTM identification with excellent performance. However, their performance can be influenced by sample type, particularly for MALDI-TOF MS. The alarming and heterogeneous antibiotic resistance patterns also highlight the critical need for rapid and accurate species identification and drug susceptibility testing to inform effective therapeutic strategies. Key messagesMolecular technologies demonstrate high accuracy for NTM identification.Antibiotic resistance is a serious concern with variations among NTM species and subspecies.Rapid and accurate species identification and drug susceptibility testing are crucial for guiding effective clinical management of NTM PD.

Humans

Herbicolin A, an antifungal lipopeptide produced by Pantoea agglomerans APC 4211 is a promising biocontrol agent against food spoilage fungi.

Fungal contamination of food with yeast and molds is associated with major economic losses due to spoilage and also poses health risks in the form of mycotoxin production. The strain Pantoea agglomerans APC 4211 isolated from leaves of Ilex aquifolium (holly tree) has broad spectrum antifungal activity against a variety of food spoilage fungi. Genomic analysis of the strain confirmed the presence of biosynthetic gene clusters potentially encoding for the enzymatic machinery required for the production of the antifungal lipopeptide herbicolin A. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of the cell-free supernatant (CFS) confirmed the presence of molecular masses corresponding to herbicolin A (1300.8 Da), and herbicolin B (1138 Da). Purified herbicolin A has desirable properties for biotechnological applications, including potent antifungal activity against a range of spoilage fungi, thermal stability and resistance to proteases. The lipopeptide has low cytotoxicity against epithelial cell lines and has minimum inhibitory concentrations (MICs) lower than those of some commercial antifungal drugs (0.2-2.5 mg/L). In a model dairy system (10% skim milk), herbicolin A demonstrated excellent solubility and stability, effectively eliminating Aspergillus niger and Penicillium notatum at a concentration of 5 mg/L. Overall, the study determines herbicolin's A spectrum against food spoilage organisms and examines potential applications in food. In conclusion, herbicolin A is a potent, naturally occurring antifungal agent with the potential to be applied as a biopreservative in food systems, providing a safe, clean-label, and efficient compound for synthetic preservatives replacement.

Pantoea

Thermal analysis techniques for microplastic mass quantification: Methodological challenges and standardization needs.

Microplastics (MPs, 1 &#x3bc;m-5 mm) and nanoplastics (NPs, <1&#x202f;&#x3bc;m) are ubiquitous contaminants requiring standardized quantification methods. This systematic review evaluates thermal analysis techniques for mass-based MP detection, including pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), thermogravimetry-MS (TGA-MS), thermal extraction desorption-GC-MS (TED-GC-MS), and differential scanning calorimetry (DSC). Database searches (Web of Science, from inception to December 1, 2025) following PRISMA guidelines identified studies across seven environmental matrices (water, soil/sediment, atmosphere, biota, human tissues). We identify critical standardization gaps: inconsistent marker ion selection, unvalidated conversion factors for tire and road wear particles (TRWPs), and the absence of certified reference materials for complex matrices. Py-GC-MS demonstrates versatility but suffers from lipid interference in biological samples; TED-GC-MS offers superior sensitivity (sample capacity &#x223c;200&#xd7; Py-GC-MS) but lacks real-time chromatographic monitoring. To advance data comparability, we propose: (i) harmonized ion selection hierarchies based on specificity-sensitivity balance, (ii) matrix-specific TRWP quantification protocols, and (iii) inter-laboratory validation using environmental reference materials. This review provides a methodological roadmap for standardizing thermal analysis in MP research.

Humans