Search PubMedSearch

SEARCH · Search PubMed

Results for “precision transfusion intelligence”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

253 records · Page 5Linked to original sources

User Engagement and Feature Preferences in an AI-Powered mHealth Intervention for Diabetes Prevention: Secondary Analysis of a Randomized Controlled Trial.

BACKGROUND: Prediabetes is highly prevalent and increasing globally, yet lifestyle interventions remain underused. AI-driven mobile health (mHealth) tools can help scale diabetes prevention efforts, but the key factors driving their success are not well understood. OBJECTIVE: This post hoc secondary analysis of a randomized controlled trial (RCT) aimed to characterize the most valued features and the role of user engagement in outcomes of a fully automated mHealth intervention for diabetes prevention. METHODS: Data from 151 participants with prediabetes and overweight or obesity who were assigned to an AI-based diabetes prevention program (Sweetch) in a parent RCT (NCT05056376) were analyzed. Engagement (defined as the total number of days the app was used) was categorized into tertiles (low, medium, and high). Baseline characteristics were compared across engagement groups using ANOVA, Kruskal-Wallis, and chi-square tests, and regression models assessed the association between engagement and achievement of diabetes risk reduction outcomes (&#x2265;5% weight loss, &#x2265;4% weight loss with &#x2265;150 min/week of physical activity, or &#x2265;0.2 percentage point reduction in hemoglobin A1c [HbA1c] at 12 months). Perceived usefulness of intervention features was surveyed at 12 months. RESULTS: Median engagement was 98 (IQR 34-232) days. Older age (P<.001) and lower baseline BMI (P=.04) were significantly associated with higher engagement. Compared with low engagement, high engagement was associated with greater odds of achieving the composite diabetes risk reduction outcome (odds ratio [OR] 2.59, 95% CI 1.11-6.01; P=.03), &#x2265;5% weight loss (OR 3.31, 95% CI 1.16-9.42; P=.03), and &#x2265;0.2 percentage point reduction in HbA1c (OR 3.57, 95% CI 1.19-10.75; P=.02). Participants most frequently rated weight tracking, physical activity tracking, and the digital body weight scale as the features that were most helpful for achieving their health goals. CONCLUSIONS: Higher engagement with an AI-driven intervention requiring no human intervention was associated with improved diabetes risk reduction. Contrary to concerns about lower digital literacy, older adults engaged with the intervention more than younger adults. Features related to weight and physical activity tracking were most valued by patients in the program. TRIAL REGISTRATION: ClinicalTrials.gov NCT05056376; https://clinicaltrials.gov/study/NCT05056376.

Humans

From fear to empowerment: the&#xa0;impact of employees AI awareness on workplace well-being - a new insight from the JD-R model.

PURPOSE: The primary purpose of the study was to explore the impact of health workers' awareness of artificial intelligence (AI) on their workplace well-being, addressing a critical gap in the literature. By examining this relationship through the lens of the Job demands-resources (JD-R) model, the study aimed to provide insights into how health workers' perceptions of AI integration in their jobs and careers could influence their informal learning behaviour and, consequently, their overall well-being in the workplace. The study's findings could inform strategies for supporting healthcare workers during technological transformations. DESIGN/METHODOLOGY/APPROACH: The study employed a quantitative research design using a survey methodology to collect data from 420 health workers across 10 hospitals in Ghana that have adopted AI technologies. The study was analysed using OLS and structural equation modelling. FINDINGS: The study findings revealed that health workers' AI awareness positively impacts their informal learning behaviour at the workplace. Again, informal learning behaviour positively impacts health workers' workplace well-being. Moreover, informal learning behaviour mediates the relationship between health workers' AI awareness and workplace wellbeing. Furthermore, employee learning orientation was found to strengthen the effect of AI awareness on informal learning behaviour. RESEARCH LIMITATIONS/IMPLICATIONS: While the study provides valuable insights, it is important to acknowledge its limitations. The study was conducted in a specific context (Ghanaian hospitals adopting AI), which may limit the generalizability of the findings to other healthcare settings or industries. Self-reported data from the questionnaires may be subject to response biases, and the study did not account for potential confounding factors that could influence the relationships between the variables. PRACTICAL IMPLICATIONS: The study offers practical implications for healthcare organizations navigating the digital transformation era. By understanding the positive impact of health workers' AI awareness on their informal learning behaviour and well-being, organizations can prioritize initiatives that foster a learning-oriented culture and provide opportunities for informal learning. This could include implementing mentorship programs, encouraging knowledge-sharing among employees and offering training and development resources to help workers adapt to AI-driven changes. Additionally, the findings highlight the importance of promoting employee learning orientation, which can enhance the effectiveness of such initiatives. ORIGINALITY/VALUE: The study contributes to the existing literature by addressing a relatively unexplored area - the impact of AI awareness on healthcare workers' well-being. While previous research has focused on the potential job displacement effects of AI, this study takes a unique perspective by examining how health workers' perceptions of AI integration can shape their informal learning behaviour and, subsequently, their workplace well-being. By drawing on the JD-R model and incorporating employee learning orientation as a moderator, the study offers a novel theoretical framework for understanding the implications of AI adoption in healthcare organizations.

Humans

Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.

BACKGROUND: Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear. OBJECTIVE: This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect. METHODS: This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (&#x2265;18 years of age), reporting mean polyp detection counts stratified by size (&#x2264;5 mm, 6-9 mm, and &#x2265;10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and &#x3c4;2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework. RESULTS: A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (&#x2264;5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI -1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI -0.02 to 0.06, 95% PI -0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI -0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings. CONCLUSIONS: AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment-prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932.

Colonoscopy

A narrative review of what cohorts have taught us and how they have laid the foundation for much of our understanding of type 2 diabetes.

This narrative review provides a historical perspective on how observational research on type 2 diabetes has been developed and consolidated over the last 50 years and how well-designed cohort studies will provide us with knowledge for research and practice in the future and aid guideline development. We have included data from a large number of cohorts from every continent that have been used to study the development and/or progression of type 2 diabetes, including cohorts that are general population-based, disease-based, intervention-based and registry-based. We have structured the results from the past 50 years based on the following themes: diagnosis and screening, complications, risk factors and pathophysiology. We also discuss the strengths and weaknesses of observational research when compared with other research designs. Finally, we discuss the emerging and future directions for type 2 diabetes research using cohorts, which include novel developments, such as artificial intelligence, precision health and the exposome. We conclude that cohort research has significantly advanced our understanding of type 2 diabetes and aided guideline development, and complements experimental work, such as human randomised controlled trials and animal studies. Both approaches are essential and complementary in our pursuit to provide a more comprehensive understanding of the development and progression of type 2 diabetes, and to change dogma, practice and policies for better outcomes.

Humans

Applications of metal-organic frameworks in smart packaging for food freshness indication: a comprehensive review.

Smart packaging is extensively studied for its multifunctional capabilities in antimicrobial activity, preservation, and atmosphere modification. Recently emerged metal-organic frameworks (MOFs) freshness-indicating packaging becomes a key research direction in smart packaging owing to its distinctive functions and physicochemical properties. As multifunctional materials, the unique porous structure and tunable properties of MOFs provide a distinctive approach for developing food packaging applications dedicated to food freshness indication. Existing MOFs-based smart packaging still faces potential safety risks and technical challenges in practical applications, and there remains a lack of integrated discussion that combines synthesis strategies, packaging design, optimization, and safety assessment. This review elaborates on the application of MOFs in freshness-indicating smart packaging, focusing on diverse MOFs synthesis strategies, the formats of smart packaging, types of indicator signals, and qualitative/quantitative analytical methods. It also delves into the methodology concepts of MOFs-based smart packaging and evaluates MOFs safety in food packaging by addressing potential risks. Studies show that MOFs-based smart packaging achieves qualitative and semi-quantitative analysis of food freshness through multiple signal modalities such as visible color change, fluorescence, and photothermal effects. This review emphasizes that safe MOFs design is critically important and should comply with the overall migration limit of <10 mg/dm2 specified in Regulation (EC) No 1935/2004, lanthanide element limit of <0.05 mg/kg, and FDA threshold of 1.5 &#x3bc;g/person/day. Comprehensive safety assessment and intelligent sensing platforms will constitute pivotal directions for advancing MOFs-based smart packaging toward practical application.

Food Packaging

Enhanced fracture detection on radiographs with AI assistance for clinicians: a systematic review and meta-analysis.

BACKGROUND: Emergency radiographic interpretation for fractures is prone to missed or misdiagnoses. Artificial intelligence (AI) is expected to become a powerful tool to assist clinicians in fracture detection. PURPOSE: A systematic review and meta-analysis was performed to assess whether AI improves clinicians' ability to detect fractures on radiographs. MATERIALS AND METHODS: A literature search was conducted in PubMed, Web of Science, and Cochrane Library for studies published between January 1, 2010, and October 10, 2025. A meta-analysis of diagnostic accuracy studies was performed using a Summary Receiver Operating Characteristic (SROC) curve. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Subgroup analysis and meta-regression were conducted to explore potential sources of heterogeneity. RESULTS: A total of 26 studies were included . The pooled sensitivity of clinicians increased from 77% (95% CI: 72-81) to 87% (95% CI: 83-90) with AI assistance, while the pooled specificity improved from 88% (95% CI: 85-90) to 92% (95% CI: 89-94). The corresponding AUC values were 0.90 (95% CI: 0.87-0.92) before and 0.95 (95% CI: 0.93-0.97) after AI assistance. Eight studies were rated as high risk of bias. Subgroup analysis and meta-regression identified potential sources of heterogeneity, including fracture location, AI model type, high risk of bias, and reference standards. CONCLUSION: AI assistance significantly improves clinicians' diagnostic performance in detecting fractures on radiographs for extremity and trunk fractures.

Humans

Systematic evaluation of one-dimensional-to-two-dimensional near-infrared spectroscopy transformations with deep learning for quantifying coconut sap adulteration.

Near-infrared (NIR) spectroscopy have limitations when combined with deep learning (DL) algorithms because they rely on low-dimensional datasets. Therefore, we investigated the potential of transforming one-dimensional (1D) NIR spectra into two-dimensional (2D) spectrograms using synchronous and asynchronous techniques and the continuous wavelet transform (CWT) and their effectiveness by integrating with DL for detecting adulteration in coconut sap. NIR spectra (12,500-4000&#xa0;cm-1) were collected from binary mixtures (0%-100%;w/w). The performance of all DL (convolutional neural networks-CNN, AlexNet and ResNet) models was compared with that of partial least squares (PLS). The models were ranked in the mentioned order based on their performances: 2D-CWT&#xa0;>&#xa0;2D-asynchronous > 2D-synchronous > 1D/2D-PLS. The important features of the best model can be explained and visualized using gradient-weighted-class-activation-mapping. The findings highlight that the 1D-to-2D NIR data transformation combined with DL is a highly robust approach because it addresses the feature representation gap in NIR data and effectively captures the spatial-spectral correlations.

Spectroscopy, Near-Infrared

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (&#x3ba; = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans

Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis.

BACKGROUND: Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain. OBJECTIVE: This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, with emphasis on models using non-PSG-derived inputs. METHODS: PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2&#xd7;2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively. RESULTS: A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92-0.96; 95% PI 0.71-0.99), 0.87 (95% CI 0.84-0.89; 95% PI 0.66-0.96), and 0.83 (95% CI 0.79-0.87; 95% PI 0.61-0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69-0.84; 95% PI 0.30-0.96), 0.81 (95% CI 0.75-0.85; 95% PI 0.39-0.96), and 0.91 (95% CI 0.87-0.94; 95% PI 0.55-0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG-derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method. CONCLUSIONS: AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG-derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG-derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.

Humans

Evolution of Precision Oncology, Personalized Medicine, and Molecular Tumor Boards.

With multiple molecular targeted therapies available for patients with cancer that correspond to a specific genetic alteration, the selection of the best treatment is essential to ensure therapeutic efficacy. Molecular tumor boards (MTBs) play a key role in this process to deliver personalized medicine to patients with cancer in a multidisciplinary manner. Historically, personalized medicine has been offered to patients with advanced cancer, but the incorporation of molecular targeted therapies and immunotherapy into the perioperative setting requires clinicians to understand the role of the MTB. Evidence is accumulating to support feasibility and survival benefit in patients treated with matched therapy.

Humans

Community-driven advances in computational mass spectrometry: The perspective of EuBIC-MS members.

Advances in data acquisition, artificial intelligence, and integrative bioinformatics are driving the rapid evolution of computational mass spectrometry, and in turn, transforming modern proteomics, metabolomics, and lipidomics. These developments have greatly increased the scale and complexity of mass spectrometry data, underscoring the importance of evolving accurate, transparent, efficient and reproducible data processing workflows. Addressing these challenges requires collaborative innovation that brings together expertise in software engineering, statistics, and biology. The European Bioinformatics Community for Mass Spectrometry (EuBIC-MS), an initiative of the European Proteomics Association (EuPA), fosters a culture of open, community-driven development through its biennial Developers Meetings and Winter Schools. This commentary summarizes the scientific background and outcomes of the EuBIC-MS Developers Meeting 2025, which took place in Novacella, Italy. Three keynote presentations highlighted major frontiers in the field: deep proteome and phosphoproteome profiling, text mining for protein-protein interaction extraction, and scalable proteomics for AI-driven drug discovery. Seven community-selected hackathons addressed emerging challenges such as single-cell proteomics data analysis, FAIR metadata extraction, deep learning frameworks, R-Python interoperability, and DIA validation. Together, these efforts demonstrate the potential for scientific and technical innovation to arise from open collaboration, and highlight how community-driven initiatives can accelerate progress in computational mass spectrometry. SIGNIFICANCE: Modern proteomics increasingly depends on computational advances to translate complex, high-dimensional data into biological knowledge. The EuBIC-MS Developers Meeting 2025 exemplifies how community-driven collaboration can directly accelerate this process by bringing together experts from bioinformatics, statistics, and experimental proteomics to co-develop open, interoperable, and reproducible analytical tools. By fostering shared software frameworks, transparent benchmarking, and collaborative problem solving, the EuBIC-MS community helps ensure that technological innovation translates into reliable biological insights. This collaborative model strengthens the foundation for quantitative, system-level understanding of proteomes and establishes a sustainable path for integrating artificial intelligence and next-generation data acquisition into routine biological discovery. This commentary shows some current highlights in the field of computational mass spectrometry and community-based approaches undertaken during the most recent Developers Meeting to solve these challenges. The approaches discussed and initiated during the meeting - ranging from deep proteome profiling and phosphosite mapping to text mining, single-cell data analysis, and FAIR metadata extraction - address key bottlenecks that currently limit the biological interpretability and comparability of proteomics data.

Mass Spectrometry

Molecular Landscape and Advanced Diagnostic Technologies for BRAF Mutations in Cancer: From Quantitative PCR and ddPCR to CRISPR-Based Platforms.

BRAF mutations are key oncogenic alterations across multiple malignancies, including melanoma, thyroid carcinoma, colorectal cancer, non-small cell lung cancer, glioma, and hairy cell leukemia. The most prevalent variant, BRAF-V600E, induces constitutive activation of the MAPK signaling pathway, promoting tumor progression and influencing therapeutic responsiveness. Accurate detection of BRAF alterations is therefore essential for molecular classification, prognostic assessment, treatment selection, and resistance surveillance. This review summarizes the molecular heterogeneity of BRAF mutations and critically evaluates current diagnostic methodologies. Conventional approaches such as allele-specific PCR and Sanger sequencing are compared with advanced quantitative platforms, including high-resolution melting analysis, droplet digital PCR, and next-generation sequencing, with emphasis on analytical sensitivity, mutation coverage, and clinical applicability. Emerging technologies such as CRISPR-based assays, rolling circle amplification systems, and nanoparticle-based biosensors and point-of-care diagnostic platforms are also discussed for their potential to enhance ultra-sensitive detection, particularly in liquid biopsy settings. These emerging tools are highlighted for their potential to enable ultra-sensitive, rapid, and decentralized mutation detection, particularly in liquid biopsy settings. Key challenges, including intratumoral heterogeneity, low allele-frequency variants, FFPE-associated artifacts, and clonal evolution under therapeutic pressure, are examined within a translational framework. In addition, we examine critical barriers to clinical implementation, including standardization, cost, and global accessibility of molecular diagnostics, and outline potential solutions through scalable technologies and decentralized testing strategies. We propose that optimal BRAF testing requires a mutation subclass-informed and clinically integrated strategy combining comprehensive baseline profiling with longitudinal molecular monitoring. Future diagnostic paradigms will likely integrate multi-omics data and artificial intelligence (AI)-assisted interpretation to refine precision oncology implementation. Looking forward, we propose that optimal BRAF testing will require integration of multi-omics profiling with AI-assisted interpretation, enabling automated variant classification, real-time clinical decision support, and improved prediction of therapeutic response and resistance.

Humans

Precision Oncology in Hepatopancreatobiliary Cancer Surgery.

Advances in technology have allowed for the characterization of tumors at the genomic, transcriptomic, and proteomic levels. There are well-established targets for biliary tract cancers, with exciting new targets emerging in pancreatic ductal adenocarcinoma and potential targets in hepatocellular carcinoma. Taken together, these data suggest an important role for molecular profiling for personalizing cancer therapy in advanced disease and need for design of novel neoadjuvant studies to leverage these novel therapeutics perioperatively in the surgical patient.

Humans

From prediction to mechanism: Explainable AI uncovers plasma and CSF proteomic signatures of Alzheimer's disease.

Alzheimer's disease (AD) plasma and cerebrospinal fluid (CSF) proteomics can distinguish AD from cognitively normal controls, but the generalizability of machine learning performance and the recurrence of biological signals across datasets require cautious interpretation. We developed an explainable artificial intelligence framework spanning two fluids and four ADNI proteomic datasets, covering 2082 modality specific samples, all analysed internally within ADNI. Phase 1 analysed plasma using a 119 analyte NULISA and targeted UPENN panel (n&#xa0;=&#xa0;727; 216&#xa0;CE, 511 controls). Phase 2 extended the analysis to CSF using SOMAscan7k, TMT-MS and targeted SET2, with Elecsys A&#x3b2;42, A&#x3b2;40, total tau and p-tau181 as anchor biomarkers. Only SOMAscan was subject-independent relative to Phase 1 plasma; TMT-MS and SET2 overlapped with Phase 1 for 96.0% and 97.7% of subjects and therefore are not independent replication cohorts. Under subject-level splits with fold internal preprocessing, we compared Elastic Net, Explainable Boosting Machines and gradient boosted trees with SHAP-based explanations. Among the candidate pipelines, we selected the pipeline with the highest held-out test ROC AUC for each platform; the selected values were 0.927 in plasma and 0.954-0.973 across the three CSF datasets. Because the same held out test performance was used for pipeline selection and headline reporting, these are optimistically selected single-holdout estimates, not unbiased estimates of generalizable or clinical performance. Explanations identified five recurring biological axes within ADNI: cholinergic (ACHE), tau/14-3-3 (YWHAG, YWHAZ, YWHAB, YWHAE), neuro-axonal (NEFL, NEFH), microglial/complement (CHIT1, SMOC1, CHI3L1, C7, CFH) and synaptic (NPTXR, NPTX2, DLG4, SYT5, VSNL1, ELAVL2). CSF analyses showed synaptic vesicle-cycle enrichment (q&#xa0;=&#xa0;2&#xa0;&#xd7;&#xa0;10-6), and CSF YWHAG correlated strongly with total tau (&#x3c1;&#xa0;=&#xa0;0.87). Cross-fluid directional concordance was modest overall (54-57%) but increased to 73-80% among mapped analyte/protein rows reaching q&#xa0;<&#xa0;0.05 in CSF. These findings provide hypothesis-generating, internally supported evidence within ADNI. Independent external cohorts with locked pipelines are required to evaluate generalizable performance and biological reproducibility; the overlapping TMT-MS and SET2 analyses should not be interpreted as independent replication.

Alzheimer Disease

AI Health message intervention: The role of message customization and message source in breast cancer screening among women of color.

OBJECTIVES: To examine the effectiveness of breast cancer screening messages with varying levels of customization (generic, targeted, and tailored) and to compare AI-generated versus human-generated messages. METHODS: A between-subjects experimental design with a control condition was employed. Message content followed a standardized structure and varied by level of customization: generic, targeted (demographic-based), and tailored (perceived susceptibility- and barrier-based). Messages were developed by either the authors or GenAI (ChatGPT-4o). A total of 391 participants recruited via Prolific were randomly assigned to five groups (generic, targeted-human, targeted-AI, tailored-human, and tailored-AI). Self-efficacy, behavioral intentions, attitudes, and message believability were measured using different scales. RESULTS: Customized (tailoring and targeting) health messages performed comparably to generic messages in shaping positive health outcomes. GenAI-generated messages also produced outcomes comparable to those of human-generated messages under standardized conditions. Significant negative indirect effects through message believability for the human-tailored condition was found relative to the generic condition. CONCLUSIONS: GenAI may be a useful tool for developing and customizing scalable health messages. Its effectiveness depends not only on customization but also on maintaining message quality, including readability, clarity, coherence, naturalness, and credibility. PRACTICAL IMPLICATIONS: GenAI may support health practitioners in developing customized and scalable breast cancer messages. However, professional review remains necessary to ensure that the message is culturally appropriate, responsive to patient concerns, and suitable for use alongside patient-provider communication.

Humans

Cost-Effectiveness and the Economics of Genomic Testing and Molecularly Matched Therapies.

Cost-effectiveness analysis of precision oncology can help guide value-driven care. Next-generation sequencing is increasingly cost-efficient over single gene testing because diagnostic algorithms require multiple individual gene tests to determine biomarker status. Matched targeted therapy is often not cost-effective due to the high cost associated with drug treatment. However, genomic profiling can promote cost-effective care by identifying patients who are unlikely to benefit from therapy. Additional applications of genomic profiling such as universal testing for hereditary cancer syndromes and germline testing in patients with cancer may represent cost-effective approaches compared with traditional history-based diagnostic methods.

Humans

Bipolar circumcision with mucocutaneous plane separation: A safe, precise, blood-sparing, dressing-free approach.

Conventional circumcision techniques may result in bleeding, limited control of the mucosal collar, and the need for dressings. We describe a modified bipolar technique enabling near-bloodless dissection with precise mucosal trimming. Following bipolar division of the preputial skin, the inner mucosa is separated using two forceps and retracted proximally, creating a protective plane for safe skin adjustment. The mucosal collar is trimmed with scissors. The wound is closed with sutures and 2-octyl cyanoacrylate, avoiding dressings. This technique has been performed in 55 consecutive cases (median age: 2 years and 2 months; range: 0 days-17 years and 5 months) with no reported complications over a median follow-up of 2 years and 7 months (range: 3 months-4 years and 1 month).

Humans

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans