Search PubMedSearch

PubMed · 42714031

Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.

Abstract

BACKGROUND: Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear. OBJECTIVE: This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect. METHODS: This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (≥18 years of age), reporting mean polyp detection counts stratified by size (≤5 mm, 6-9 mm, and ≥10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and τ2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework. RESULTS: A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (≤5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI -1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI -0.02 to 0.06, 95% PI -0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI -0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings. CONCLUSIONS: AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment-prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932.

Explore related subjects

Keep this discovery

BibTeXRIS

Ling Ba, Yaxin Qi, Xinrui Lv, Sipu Wang, Lu Yang, Yufeng Wang, Bangmao Wang, Hailong Cao, Xin Xu. 2026-09-09. Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.. https://doi.org/10.2196/95841

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Endoscopic mucosal resection with precutting vs. anchoring technique using snare tip for 10-25 mm nonpedunculated colorectal polyps: a randomized controlled trial.

BACKGROUND AND AIMS: Modified endoscopic mucosal resection (EMR) techniques using a snare tip, precutting EMR (P-EMR) and anchoring EMR (A-EMR), have been developed for the effective resection of nonpedunculated colorectal polyps measuring 10-25&#x2005;mm. Although previous studies have compared either P-EMR or A-EMR with conventional EMR, no study has directly compared these two snare tip-assisted techniques within modified EMR. This study aimed to evaluate P-EMR and A-EMR in terms of the R0 resection rate and procedure duration. METHODS: This prospective randomized controlled trial enrolled patients with nonpedunculated colorectal polyps measuring 10-25&#x2005;mm. The patients were randomly assigned to the P-EMR or A-EMR groups. The primary outcome was R0 resection rate, defined as en bloc resection with histologically tumor-free margins. Secondary outcomes included the injection-to-snaring time, total procedure time, and adverse events. RESULTS: Each group included 63 polyps, of which 126 were analyzed in the final evaluation. Both groups achieved high R0 resection rates (93.7% for P-EMR and 88.9% for A-EMR), with no significant difference ( P &#x2005;=&#x2005;0.344). However, the A-EMR group demonstrated significantly shorter injection-to-snaring time (181.8&#x2005;&#xb1;&#x2005;81.9 vs. 320.9&#x2005;&#xb1;&#x2005;143.5&#x2005;s, P &#x2005;<&#x2005;0.001) and total procedure time (259.7&#x2005;&#xb1;&#x2005;139.7 vs. 479.8&#x2005;&#xb1;&#x2005;249.0&#x2005;s, P &#x2005;<&#x2005;0.001). Adverse events, including intraprocedural and delayed bleeding, were comparable between the groups. CONCLUSION: Both P-EMR and A-EMR demonstrated high R0 resection rates for nonpedunculated polyps measuring 10-25&#x2005;mm. However, A-EMR achieved these outcomes with a shorter procedure time than P-EMR.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

SGLF-Net:Staged Global-to-Local Cross-Scale Fusion Network for Colonoscopic Polyp Segmentation.

Polyp segmentation in colonoscopy images plays a pivotal role in computer-aided medical diagnosis and the early prevention of colorectal cancer. However, existing methods often suffer from performance degradation when confronted with extreme polyp scale variation and polyp boundary ambiguity. To address these challenges, we propose the Staged Global-to-Local Cross-Scale Fusion Network (SGLF-Net), which adopts a novel staged global-to-local learning paradigm to progressively refine segmentation from coarse global semantics to fine-grained local details. Specifically, the Global Semantic Perception Stage integrates a Swin Transformer Encoder and a Dynamic Attentive Decoder (DAD) to construct comprehensive multi-scale contextual representations. The Local Detail Refinement Stage employs an Edge-aware Dynamic Attentive Decoder (E-DAD) to enhance structural fidelity and boundary precision through explicit edge-guided supervision. Furthermore, we introduce the Cross Spatial-Scale Feature Aggregation and Reconstitution (CSSAR) module, equipped with hybrid attention mechanisms, to facilitate efficient semantic structural interaction between the two cascaded stages. Extensive experiments on five public benchmark datasets demonstrate that SGLF-Net consistently outperforms state-of-the-art methods in both segmentation accuracy and boundary preservation.

Journal Article