Search PubMedSearch

SEARCH · Search PubMed

Results for “Robot-assisted surgery”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

382 records · Page 5Linked to original sources

An AI-assisted Clinical Decision Support System for Green Classification of Cystocele on Dynamic Transperineal Ultrasound.

Green classification of cystocele on dynamic transperineal ultrasound (TPUS) remains operator-dependent because it requires manual frame selection and landmark-based assessment of the Valsalva maneuver. We developed a workflow-oriented AI-assisted clinical decision support system for automated urethrovesical junction localization and dynamic Green classification and prospectively evaluated its standalone and reader-support performance. This diagnostic accuracy and reader study included 881 patients from a tertiary referral hospital, comprising a retrospective development cohort (n = 688) and an independent prospective test cohort (n = 193). A nested subset of 67 prospective patients was used for a reader study involving two junior and two intermediate radiologists under unaided and AI-assisted conditions. In the complete prospective test cohort, Green-AttGRU achieved a macro-averaged AUC of 0.939 (95% CI, 0.897-0.971) and an overall accuracy of 0.902 (95% CI, 0.860-0.943). In the reader study, overall accuracy increased from 0.761 to 0.821 without AI to 0.851-0.881 with AI, while macro-F1 increased from 0.660 to 0.777 to 0.820-0.860. Overall inter-reader agreement increased from a Fleiss' κ of 0.453 to 0.786, and pooled median interpretation time decreased from 26.7 s to 9.9 s. These findings support the preliminary feasibility of the system as a workflow-oriented decision-support tool for dynamic TPUS interpretation.

Humans

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Vortex-assisted liquid-liquid microextraction based on natural deep eutectic solvents for the determination of pyrethroid pesticides in urine.

A novel, facile, and environmentally friendly analytical method was developed based on vortex-assisted liquid-liquid microextraction and high-performance liquid chromatography with diode-array detection for detecting pyrethroid pesticides (PPs) in urine. Natural deep eutectic solvents (NADESs) were prepared using plant essential oil-derived monoterpenoids (thymol, carvacrol, and menthol) combined with aromatic primary alcohols (benzyl alcohol, phenethyl alcohol, and phenylpropyl alcohol) as hydrogen bond donors and acceptors. These solvents served as environmentally benign extraction media, thereby avoiding the use of conventional volatile, toxic organic solvents. NADESs are naturally derived, easy to prepare, biodegradable, and environmentally friendly solvents. Hydrophobic and &#x3c0;-&#x3c0; interactions between the NADESs and PPs may contribute to enhancing the affinity of PPs toward the NADESs phase. Vortex technology, accelerating mass transfer between the sample and extractant phases, enables fast extraction of PPs. Under optimized conditions, the method achieved a low detection limit (0.002&#xa0;mg&#xa0;L-1), satisfactory precision with relative standard deviations (0.3%-2.4%), and acceptable recovery (80.7%-86.2%). The method demonstrated excellent performance in urine analysis and was feasible as a facile and green strategy for monitoring the content of PPs in biological matrices and assessing exposure risk.

Liquid Phase Microextraction

Ketamine assisted psychotherapy to reduce chronic neuropathic pain: A mixed-methods randomized pilot trial.

BACKGROUND: Intravenous ketamine can provide short-term analgesia in chronic neuropathic pain but benefits often wane after treatment. We conducted a randomized pilot trial to assess the feasibility of combining ketamine infusions with psychotherapy to inform future efficacy trials. METHODS: In this single-center, randomized, outcome-assessor-blinded pilot trial at a Canadian tertiary pain clinic, adults with moderate-to-severe chronic neuropathic pain were randomly assigned in 1:1:1 ratio to the ketamine, psychotherapy, or combined ketamine plus psychotherapy arm. Ketamine was delivered as three intravenous infusions over 16 weeks; psychotherapy consisted of 16 weekly cognitive behavioral therapy and mindfulness-based meditation sessions. The primary outcome was feasibility, assessed using prespecified progression criteria. Exploratory outcomes included changes in pain interference (PROMIS 6a T-score), pain intensity, mood, and qualitative interview findings at week 20 (ClinicalTrials.gov: NCT05639322). FINDINGS: Between October 23, 2023, and March 31, 2025, 30 participants were randomized, and 26 (87%) completed 20-week follow-up. Most feasibility criteria, including consent, retention, data completeness, and absence of study-related serious adverse events, were met; adherence targets were partially met. Exploratory pain outcomes showed numerical improvement across groups, with clinically meaningful reductions observed for pain interference and pain intensity. Sixty-four adverse events were recorded, mostly mild and in ketamine-containing groups; no serious study-related adverse events occurred. CONCLUSIONS: Combined ketamine and psychotherapy was feasible and acceptably safe in this pilot trial, supporting evaluation in a larger efficacy-powered study. FUNDING: The study was funded by the St. Michael's Hospital Innovation Fund, The Canadian Pain Society Early Investigator Award and the Physician Services Incorporation Early Career Researcher Award.

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77&#xa0;fg/&#x3bc;L to 1&#xa0;ng/&#x3bc;L, with an LOD of 2.02&#xa0;fg/&#x3bc;L and an LOQ of 3.77&#xa0;fg/&#x3bc;L. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P&#xa0;>&#xa0;0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Infertility treatment in women with epilepsy: A systematic review.

BACKGROUND: The impact of assisted reproductive technologies (ART) on seizure control in women with epilepsy remains incompletely understood. METHODS: A systematic review was conducted according to PRISMA guidelines. EMBASE, MEDLINE, CINAHL, Scopus, and the Cochrane Library were searched from inception to March 2025. Eligible studies included observational studies and case-based reports involving women undergoing infertility treatment. RESULTS: A total of 1216 publications were identified, of which four studies met the inclusion criteria, including case reports, a case series, and a cohort study. These studies included 16 women aged 25-46&#xa0;years undergoing infertility treatment, all but one of whom had epilepsy. Interventions involved in vitro fertilization (IVF), ovulation induction, and hormonal therapies. Patients were treated with a range of antiseizure medications (ASMs), including carbamazepine, clobazam, lamotrigine, levetiracetam, oxcarbazepine, valproate, and zonisamide, either as monotherapy or in combination. Seizure frequency was generally stable, with most patients maintaining baseline seizure control. Seizure exacerbations were uncommon and primarily associated with hormonal therapy and reduced ASM levels, particularly reduced lamotrigine levels. Reported events included breakthrough seizures in the setting of decreased lamotrigine concentrations, seizure clusters associated with follitropin beta, and a new-onset seizure following dehydroepiandrosterone exposure. Across studies, multiple ART attempts resulted in live births with different ASM regimens, as well as in patients not receiving ASMs. CONCLUSION: Available evidence suggests that ART is feasible in women with epilepsy, with most patients maintaining stable seizure control. Hormonal therapy may affect ASM pharmacokinetics and seizure threshold, thereby warranting close monitoring. Larger prospective studies are needed to better define ASM-specific effects and optimize care.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

First insights into the role of evolutionary history in shaping venom composition of Vipera ammodytes.

Understanding intraspecific venom variation requires distinguishing the contributions of neutral population history from natural selection. This study aims to determine whether venom variation in Vipera ammodytes species complex is structured across eight phylogenetic groups. Despite a complex evolutionary history, venom composition did not differ among phylogenetic groups within the analytical framework used, suggesting that shared ancestry alone does not explain venom variation. Whether local adaptation to environmental conditions explains the observed variation remains an open question for future studies.

Animals

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Failure modes and effects analysis for clinical implementation of online adaptive radiotherapy: A systematic review.

BACKGROUND: The accuracy of radiotherapy is limited by anatomical variations occurring over time scales ranging from sub-seconds to days. Online Adaptive Radiotherapy (OART) addresses this by enabling daily plan adaptation based on real-time imaging. While OART offers improved dose conformity, its dynamic, time-constrained workflow introduces novel failure modes that challenge traditional quality assurance protocols. PURPOSE: This study aims to synthesize the existing literature on Failure Modes and Effects Analysis (FMEA) for OART to systematically catalog risks and identify mitigation strategies. METHODS: A systematic literature search was conducted to identify studies applying FMEA to OART workflows. Eleven studies were included, covering MR-guided (ViewRay MRIdian, Elekta Unity), CBCT-guided (Varian Ethos), and MR-enhanced C-arm linac systems. To address heterogeneity in risk scoring methodologies (e.g., TG-100 10-point scales vs. 5-point rankings), extracted failure modes were harmonized into a standardized three-tier risk classification system (Class I: Low, Class II: Intermediate, Class III: High). RESULTS: A total of 300 unique failure modes were identified, with 49.6 percent classified as high-risk (Class III). Analysis revealed that the majority of high-risk failures were concentrated in the online treatment delivery phase, specifically within human-computer interactions and anatomical contouring steps. CONCLUSIONS: This study supports the development of tailored, robust QA frameworks that prioritize human factors and process consistency to guide safe implementation in diverse clinical settings.

Humans

Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.

Accurate species-level identification within the genus Serratia remains challenging due to extensive phenotypic overlap and high genomic relatedness among closely related and recently described taxa. This study presents an evaluation of routine and genome-based identification approaches applied to clinical Serratia isolates, integrating phenotypic assays, MALDI-TOF MS (Bruker Daltonics), 16S rRNA gene sequencing, and Whole-Genome Sequencing (WGS). A total of 103 isolates collected from a teaching hospital were analyzed. WGS was performed on a subset of isolates. Conventional biochemical methods classified all isolates as Serratia marcescens, whereas MALDI-TOF MS identified 60.1% as S. marcescens, 11.6% as S. ureilytica, and 28.1% just at the genus level. Peak analysis from MALDI-TOF MS revealed specific peaks associated with S. marcescens and S. ureilytica, but limited discriminatory power. WGS of six isolates initially identified as S. ureilytica by MALDI-TOF MS revealed reclassification as Serratia sarumanii (n = 5) and Serratia montpellierensis (n = 1), supported by Average Nucleotide Identity (ANI), Average Amino Acid Identity (AAI), and Digital DNA-DNA Hybridization (dDDH) thresholds. In contrast, 16S rRNA analysis showed limited species-level resolution. Phylogenomic and SNP-based analyses confirmed these classifications with strong support. Overall, this study underscores the critical role of high-resolution genomic approaches for precise species identification and highlights the need for continuous expansion and curation of MALDI-TOF MS reference databases to support reliable clinical diagnostics and epidemiological surveillance of emerging Serratia species.

Spectrometry, Mass, Matrix-Assisted Laser Desorpti

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Robust optimisation for photon radiotherapy: A scoping review of models, paradigms, and reporting.

BACKGROUND AND PURPOSE: Robust optimisation offers an alternative to conventional margin-based photon radiotherapy planning by explicitly modelling uncertainty, but practice is variable and not standardised. MATERIALS AND METHODS: A scoping review was conducted to map robust optimisation for photon external beam radiotherapy. Electronic searches of Scopus, PubMed and Google Scholar (2000-2025, English language) identified planning studies that incorporated modelled uncertainties into the optimisation process and reported at least one robustness-related outcome. Data were charted on clinical context, uncertainty models, optimisation paradigms, robustness metrics and evidence for clinical implementation. RESULTS: Seventy-one studies were included. Most investigated prostate, breast or lung cancer and used intensity-modulated radiotherapy or volumetric-modulated arc therapy in commercial or research treatment planning systems. Scenario-based worst-case (minimax) optimisation was the dominant paradigm in clinically oriented work, while chance-constrained, conditional value at-risk, distributionally robust and adaptive formulations were confined to small methodological series. Uncertainty modelling focused mainly on rigid set-up error; fewer studies incorporated respiratory motion, inter-fraction anatomical change, dose-calculation uncertainty or biological variation. Robustness was evaluated with diverse scenario-based dose-volume metrics, probabilistic coverage measures, composite robustness indices and, less often, biological endpoints. Direct clinical implementation reports were scarce. CONCLUSION: Robust photon planning is technically feasible and generally maintains or improves target coverage and organ sparing compared with margin-based planning. However, heterogeneity in uncertainty models, optimisation configuration and robustness reporting limits comparison and synthesis. Pragmatic minimum standards are proposed to support future consensus and wider clinical adoption.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans