Search PubMedSearch

SEARCH · Search PubMed

Results for “Infrared Rays”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

76 records · Page 2Linked to original sources

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

INTRODUCTION: Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT. METHODS: This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used. RESULTS: The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 ± 139 HU; P = 0.107). CONCLUSION: Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality. IMPLICATIONS FOR PRACTICE: These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

Humans

Imaging techniques for assessing the hand in systemic sclerosis: a systematic review.

BACKGROUND: Systemic sclerosis (SSc) is a rare autoimmune connective tissue disease frequently associated with hand involvement, leading to significant functional impairment. Imaging techniques provide unique opportunities to visualize and quantify structural and functional abnormalities of the hand, supporting diagnosis, monitoring, and treatment evaluation. This systematic review summarizes the imaging techniques used in SSc. METHODS: A systematic search of PubMed and Embase was conducted. Eligible studies included original research articles in English that applied or evaluated imaging techniques of the hands in SSc, published after 2000. Ultrasound and nailfold capillaroscopy were excluded, given their established use. Screening was performed independently by two authors. Findings were synthesized by clinical manifestations, study quality was assessed using the QUADAS-2 tool. RESULTS: Sixty-one studies met the inclusion criteria. In total, 25 distinct imaging techniques were identified, enabling assessment of various hand structures, including vascular involvement, inflammation, fibrosis, calcifications, erosions, and bone marrow edema. Vascular imaging was most extensively studied, particularly in the context of Raynaud's phenomenon and digital ischemia, with multiple techniques demonstrating impaired perfusion and altered thermoregulatory responses. MRI consistently detected subclinical inflammatory and erosive changes of joints and soft tissues,. CT-based techniques provided detailed assessment of calcinosis cutis, while optical and photoacoustic methods showed promise for quantifying skin fibrosis. CONCLUSION: Imaging techniques provide valuable, complementary insights into hand involvement in SSc, often revealing subclinical disease. Despite promising results, limited standardization and longitudinal validation currently restrict clinical implementation. Future studies should focus on harmonizing protocols and validating against clinically meaningful outcomes.

Humans

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30 kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50 kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

Integrated photoelectrocatalytic reduction and oxidation processes to achieve efficient degradation of fluoxetine in pharmaceutical wastewater.

Fluorinated organic compounds have been frequently detected in aquatic environments, with the widespread use of fluorinated drugs. The existing processes of urban sewage treatment plants are difficult to completely remove these pollutants containing the persistent C-F bonds. In this work, an integrated system of UV-activated sulfite and UV-assisted electrochemical oxidation was innovatively constructed for efficient degradation of fluoxetine. For the UV-activated sulfite unit system, when the sulfite dosage was 0.5 mmol/L and the initial pH was about 10, the defluorination efficiency of 5 mg/L fluoxetine wastewater under nitrogen atmosphere was about 98 %. Subsequently, the UV-assisted electrochemical oxidation unit system was employed to treat the reduced wastewater mentioned above. When the sodium chloride dosage was 25 mmol/L, the initial pH was about 5, and the current density was 30 mA/cm2, the total organic carbon (TOC) removal of the wastewater arrived at 65 %. Active species capture experiments and ESR tests confirmed that hydrated electrons, hydroxyl, and chlorine radicals were the main components for the efficient degradation of fluoxetine. According to the analysis of Fukui function and HPLC-MS, the degradation pathway of pollutants was proposed including defluorination and mineralization. Meanwhile, the toxicity of intermediates was predicted using the ECOSAR program. In addition, the verification test of actual wastewater treatment indicated that the defluorination and TOC removal efficiency of fluorouracil by the integrated system were similar to those for fluoxetine. This work provided a new approach for the efficient degradation of fluorinated organic pollutants in pharmaceutical wastewater.

Fluoxetine

UV-based homogeneous disinfection process for removal of antibiotic resistance genes: Efficiency, mechanisms and influencing factors.

The proliferation and dissemination of antibiotic resistance genes (ARGs) in aquatic environments pose a serious threat to global public health. Ultraviolet-driven homogeneous advanced oxidation processes (UV-AOPs) represent a prospective suite of technologies for the efficient removal of ARGs. This review critically assesses recent advances in the application of UV-AOPs, specifically UV/hydrogen peroxide (UV/H2O2), UV/peracetic acid (UV/PAA), UV/persulfate (UV/PS), and UV/chlorine (UV/Cl), for the elimination of extracellular ARGs and intracellular ARGs. The underlying mechanisms involve direct ultraviolet-induced DNA damage, including pyrimidine dimer formation and strand breakage, as well as oxidation mediated by radicals such as hydroxyl radicals, sulfate radicals, carbon-centered radicals, and reactive chlorine species. The relative contribution of radical and non-radical pathways is strongly influenced by water chemistry and process conditions. We further expound on the critical operational and environmental factors governing ARG removal kinetics, including UV wavelength and fluence, oxidant type and dosage, ARG sequence characteristics, pH, ubiquitous anions, and dissolved organic matter, which collectively affect radical generation, quenching, and reaction microenvironments. Notably, for i-ARGs, UV-AOPs facilitate degradation not only through direct radical attack but also by disrupting cellular integrity and permeabilizing membranes, thereby enhancing the exposure of genetic materials to oxidative and photolytic damage. This review synthesizes current understanding to provide a mechanistic basis for the design and optimization of UV-AOP systems, highlighting their potential as effective barriers against the dissemination of antibiotic resistance in water reuse and purification scenarios.

Disinfection

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

The impact of absolute change in tibiofemoral morphology on patient reported outcome measures post total knee arthroplasty.

BACKGROUND: Reconstructing knee morphology and alignment is important for outcomes post total knee arthroplasty (TKA). Personalised alignment strategies are proposed to improve outcomes by replicating native alignment. However, how change in morphology affects patient outcomes is unclear. This study aimed to investigate the relationship between absolute change in morphological measures post-TKA and patient reported outcome measures (PROMs). METHOD: An observational analysis of a randomised clinical trial was conducted. Participants received preoperative and postoperative CT scans and completed PROMs at six-months post-TKA. Absolute change in hip-knee-ankle angle, medial proximal tibial angle, lateral distal femoral angle, non-weightbearing joint line convergence angle, tibial and femoral rotation, and posterior tibial slope (PTS) were calculated. PROMs included visual analogue scales of pain and satisfaction (0-100), Oxford Knee Score, Forgotten Joint Score, and the Kujala Score. Regression and principal component (PCA) analyses investigated relationships between PROMs and change in morphology. RESULTS: Sixty-one participants were included for analysis (61% women, age 66.9&#xa0;&#xb1;&#xa0;9.1 [mean&#xa0;&#xb1;&#xa0;SD] years, BMI 32.8&#xa0;&#xb1;&#xa0;6.8&#xa0;kg/m2). The PCA demonstrated coronal, axial, and sagittal plane measures were interdependent, with over 65% of variability driven by change in tibial rotation (PC1) and the PTS (PC2). The regression analysis showed no relationships between morphological change and PROMs postoperatively. CONCLUSION: Tibiofemoral morphology was interrelated across coronal, axial, and sagittal planes. However, this study suggests absolute morphological change had minimal impact upon PROMs at six-months post-TKA. Future research should clearly distinguish between osteoarthritic versus prearthritic alignment and consider the influence of soft-tissue releases upon PROMs.

Humans

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans

Efficacy and safety of rib-guided percutaneous thoracic sympathetic radiofrequency thermocoagulation at two different targets for primary palmar hyperhidrosis: a randomized controlled trial.

OBJECTIVES: To compare the efficacy and safety of computed tomography-guided percutaneous thoracic sympathetic radiofrequency thermocoagulation (RFT) targeting the upper versus lateral margin of the fourth rib head for severe primary palmar hyperhidrosis (PPH). METHODS: Patients with severe PPH were randomly divided into Group U (upper margin target) and Group L (lateral margin target). Outcome measures included 1-year recurrence rate, Hyperhidrosis Disease Severity Scale (HDSS), Dermatology Life Quality Index (DLQI), palm skin temperature, finger perfusion index (PI), compensatory hyperhidrosis and patient satisfaction. RESULTS: Both groups (n&#x2009;=&#x2009;55 each, 110 sides) successfully underwent RFT. No preprocedural PI differences were found (p&#x2009;>&#x2009;0.05). Immediately post-RFT, PI in Group L was significantly higher than in Group U (left p&#x2009;=&#x2009;0.025, right p&#x2009;=&#x2009;0.013). No significant differences in HDSS grades were observed between groups before and at 1&#x2009;day, 2&#x2009;weeks, 1&#x2009;month and 3&#x2009;months post-procedure. However, at 6 and 12&#x2009;months, Group L showed significantly lower HDSS grades (left p&#x2009;=&#x2009;0.033 and 0.016; right p&#x2009;=&#x2009;0.039 and 0.025) and lower DLQI scores (p&#x2009;=&#x2009;0.037 and 0.024) than Group U. Patient satisfaction did not differ within 6&#x2009;months, but Group L had significantly higher satisfaction at 12&#x2009;months (p&#x2009;=&#x2009;0.036). CONCLUSIONS: Targeting the lateral margin of the fourth rib head for RFT achieved greater efficacy, better quality of life and higher patient satisfaction compared to the upper margin target.

Humans

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans

Intravenous thrombolysis for ischemic stroke in extended time window selected with CT perfusion: a systematic review and meta-analysis.

PURPOSE: Recent randomized controlled trials (RCTs) have provided new evidence regarding the efficacy and safety of intravenous thrombolysis (IVT) in patients with acute ischemic stroke (AIS) presenting within the extended time window (ETW). We performed a systematic review and meta-analysis to evaluate the efficacy and safety of IVT, in patients treated within the ETW and selected with perfusion imaging criteria, predominantly computed tomography perfusion (CTP). METHODS: A systematic review and meta-analysis, registered in PROSPERO, was conducted including all available RCTs comparing IVT with best medical treatment (BMT) in patients with AIS within the ETW, selected using advanced perfusion imaging criteria. The predefined efficacy outcomes were excellent functional outcome and good functional outcome at 3 months. The safety endpoints included symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days. RESULTS: Six RCTs, including 1182 patients treated with IVT and 1176 patients receiving BMT, were included. IVT was associated with a higher likelihood of achieving excellent and good functional outcomes at 3 months. Exploratory subgroup analyses by treatment timing suggested consistent findings up to 24 hours. No significant difference in 90-day mortality was observed between groups, whereas IVT was associated with an increased risk of sICH. CONCLUSION: Treatment with IVT in the ETW (4.5-24 h) in patients selected using advanced perfusion imaging, predominantly CTP, may be associated with improved functional outcomes in patients with AIS. Although IVT was associated with an increased risk of sICH, no significant increase in 90-day mortality was observed. PROSPERO REGISTRATION: CRD420261304314.

Aged

Imaging&#x2011;based models for predicting cerebrovascular complications of carotid stenosis.

This is a protocol for a Cochrane review (prognosis). The objectives are as follows: Primary objective To systematically review and critically appraise multivariable prognostic models developed for adults (&#x2265;&#x202f;18&#x202f;years) with carotid stenosis in which imaging biomarkers (e.g. plaque characteristics derived from magnetic resonance imaging (MRI), computed tomography (CT), or ultrasound) constitute the core predictors. The primary focus is to evaluate the predictive performance of these models for cerebrovascular complications - specifically ipsilateral ischaemic stroke and transient ischaemic attack (TIA) - which are the clinical outcomes to be predicted. Where feasible, we will summarise and compare the models' discrimination (C&#x2011;statistic/area under the curve (AUC)) and calibration (calibration&#x2011;in&#x2011;the&#x2011;large, calibration slope, observed&#x2011;to&#x2011;expected ratio) across studies, and assess their potential for clinical application and external validation. For the purpose of defining symptomatic carotid stenosis as an eligibility criterion and subgroup variable, we will include studies that also considered retinal ischaemia (e.g. retinal embolism, amaurosis fugax) as a qualifying event. Secondary objectives To describe the combinations of imaging markers, modelling techniques, sample sizes, and variable&#x2011;selection strategies used in the development of the included models To evaluate the performance of these models for additional secondary clinical outcomes: plaque progression or regression, incident high&#x2011;risk imaging features, and the transition from asymptomatic to symptomatic disease To explore whether predictive performance differs according to imaging modality (MRI versus CT versus contrast&#x2011;enhanced ultrasound (CEUS)) or technical protocol (e.g. 3&#x202f;T versus 1.5&#x202f;T, spectral CT versus conventional CT) For studies that report both cerebrovascular and broader cardiovascular outcomes (major adverse cardiovascular events, myocardial infarction, etc.), we will only extract the performance metrics relating to cerebrovascular events for the primary analysis. Performance metrics for cardiovascular outcomes will be considered exploratory and will not form part of the main synthesis.

Humans

Repeated scoring with the adult appendicitis score improves the sensitivity and the specificity of appendicitis diagnosis in patients with early equivocal signs of appendicitis: a secondary analysis.

PURPOSE: The utilization of computed tomography in the early stage of acute appendicitis may result in overdiagnosis and unnecessarily expose patients to ionising radiation. The Adult Appendicitis Score (AAS) can be used to select patients for imaging. Observation and re-scoring in the DIAMOND trial reduced the need for imaging. Now, we wanted to determine if the change in AAS (&#x2206;AAS) can serve as a diagnostic tool to select patients for imaging even more precisely. METHODS: Eighty-eight patients with early equivocal appendicitis participated in the observation arm of the DIAMOND trial. The data for these patients were reanalysed, and &#x2206;AAS during the observation was calculated. The baseline AAS, final AAS, and the change in C-reactive protein (&#x2206;CRP) were selected as reference standards. RESULTS: Eighty-three patients with complete data were included in the analysis. The AUROC (Area Under the Receiver Operating Characteristic) values are as follows: &#x2206;AAS, 0.932 (95% CI 0.868-0.996); baseline AAS, 0.629 (95% CI 0.498-0.760); final AAS, 0.936 (95% CI 0.886-0.987); and &#x2206;CRP, 0.796 (95% CI 0.696-0.897). Using receiver operating characteristic curves, we established the thresholds for low (AAS&#x2009;&#x2264;&#x2009;-2), intermediate (AAS -1 to 0), and high (AAS&#x2009;&#x2265;&#x2009;1) probability of appendicitis. The negative predictive value for the low-probability group and the positive predictive value for the high-probability group concerning acute appendicitis were 97% and 94%, respectively. CONCLUSION: Patients with equivocal signs of appendicitis may benefit from short observation and the calculation of &#x2206;AAS to reduce overdiagnosis and exposure to excessive imaging. REGISTRATION: The DIAMOND trial was officially registered on ClinicalTrials.gov (NCT02742402) on April 13, 2016.

Adult

The role of artificial intelligence in the diagnosis and prognosis of traumatic brain injury based on brain CT scans: a systematic review.

Traumatic brain injury (TBI) is a leading cause of emergency department visits and a major contributor to injury-related mortality and long-term neurological disability. Non-contrast computed tomography (CT) is the gold-standard imaging modality for the rapid diagnosis of TBI. Clinical outcomes depend strongly on early detection and prompt acute management. Artificial intelligence (AI)-based models may support faster automated identification of traumatic findings and early prediction of patient prognosis.&#xa0;A systematic literature search was conducted in PubMed/MEDLINE, Scopus, IEEE Xplore, ACM Digital Library, and the Cochrane Library in accordance with PRISMA 2020 guidelines to evaluate AI-based models for automated detection of TBI-related findings on CT and for prediction of clinical outcomes. Risk of bias and applicability were assessed using QUADAS-2 for diagnostic accuracy studies and PROBAST&#x2009;+&#x2009;AI for prediction model studies.&#xa0;Twenty-two studies were included. Sixteen studies evaluated diagnostic tasks and 10 evaluated prognostic outcomes, with four studies contributing to both categories. Diagnostic performance was generally high, with many studies reporting AUC values approaching or exceeding 0.90, particularly for larger lesion volumes.Prognostic performance was more variable, with moderate to high discrimination and substantial heterogeneity. Only 9 studies incorporated independent external validation, and performance was frequently lower in external cohorts. All prognostic model studies were judged to be at high overall risk of bias using PROBAST&#x2009;+&#x2009;AI, and most diagnostic accuracy studies also demonstrated high or unclear risk of bias in at least one QUADAS-2 domain, most frequently in patient selection.&#xa0;AI-based models applied to brain CT demonstrate strong technical performance for both diagnostic and prognostic tasks in TBI. However, most studies relied on retrospective designs and lacked independent external validation which limits models generalizability and raises concern for potential overfitting. Prospective, multicenter studies with standardized methodologies and rigorous external validation are required before widespread clinical implementation.

Humans

Novel non-contrast computed tomography parameters for predicting spontaneous stone passage and surgical requirement in ureteral stones: The role of ureteral wall thickness and dilatation ratio.

We investigated the predictive value of standard non-contrast computed tomography (NCCT) measurements, the ureteral dilatation ratio (DDR) and intraluminal urine stasis markers, for spontaneous stone passage (SSP) versus surgical intervention in patients with ureteral stones. We also evaluated ureteral wall thickness (UWT) as a practical clinical marker. This retrospective study included 461 patients diagnosed with ureteral stones via NCCT. Patients were categorised into two groups based on clinical outcomes: the spontaneous passage group (MET; n&#x2009;=&#x2009;229) and the endoscopic surgery group (URS; n&#x2009;=&#x2009;232). Stone volume, stone density (HU), UWT, DDR and intraluminal urine attenuation values were measured for all patients. Independent risk factors were identified using a multivariate logistic regression model and clinical cut-off values were determined via ROC curve analysis. Stone volume, density, UWT and hydronephrosis grade were all significantly higher in the URS group. Multivariate regression analysis revealed that increased UWT (OR: 5.03, 95% CI: 3.66-6.90; p&#x2009;<&#x2009;0.001) was the strongest independent predictor of surgery. Higher DDR (OR: 1.88; p&#x2009;=&#x2009;0.003), advanced hydronephrosis, stone volume, and density also increased surgical risk. A UWT cut-off &#x2265;&#x2009;2.97&#xa0;mm predicted surgery with 84.8% sensitivity and 84.3% specificity (AUC: 0.872). A DDR cut-off >&#x2009;1.79 yielded 81.7% specificity and 40.4% sensitivity. UWT weakly correlated with stone volume (r&#x2009;=&#x2009;0.145), indicating wall thickening reflects an inflammatory response rather than a mere mechanical consequence. UWT is a superior predictor of SSP failure, supported by increased DDR as a highly specific complementary risk factor. These parameters could help clinicians to identify patients who would benefit from early surgical counselling and intervention rather than prolonged conservative management.

Humans

Enhancing Hemoglobin Bart's hydrops fetalis syndrome prevention: a single-tube multiplex real-time PCR assay for the comprehensive detection of four significant &#x3b1;0-thalassemia deletions (--SEA, --THAI, --CR, and --SA) found in Thailand.

BACKGROUND: Hemoglobin (Hb) Bart's hydrops fetalis is a major public health concern in Southeast Asia, particularly in Thailand. Current screening strategies target the two most common &#x3b1;0 -thalassemia deletions (--SEA and --THAI). METHOD: In this study, we developed a single-tube multiplex real-time PCR assay for the simultaneous detection of four clinically relevant &#x3b1;0-thalassemia deletions (--SEA, --THAI, --CR, and --SA). The assay was validated using 538 clinical samples with diverse thalassemia genotypes and compared against conventional gap-PCR as the reference method. Analytical performance, including sensitivity, specificity, and limit of detection (LOD), was evaluated. In addition, clinical utility was assessed in 22 prenatal diagnosis cases at risk of Hb Bart's hydrops fetalis. RESULTS: The study cohort demonstrated substantial genetic heterogeneity, comprising 43 distinct genotypes. The developed assay achieved 100% sensitivity and specificity for all targeted deletions, with complete concordance with gap-PCR results. No cross-reactivity was observed with &#x3b1;+-thalassemia. The assay demonstrated a high analytical sensitivity with a LOD of 9.76&#x2009;&#xd7;&#x2009;10-3&#x2009;ng per reaction. Whereas in prenatal diagnosis, all 22 fetal genotypes were accurately identified, including five cases of homozygous --SEA and one rare compound heterozygous --SEA/--CR fetus. CONCLUSIONS: This study presents a rapid, accurate, and cost-effective multiplex real-time PCR assay capable of detecting both common and rare &#x3b1;0-thalassemia deletions in a single reaction. The assay demonstrates strong potential for implementation in routine clinical laboratories and large-scale population screening, contributing to improved prevention and control of severe thalassemia syndromes in high-prevalence regions.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures