Search PubMedSearch

SEARCH · Search PubMed

Results for “Bacterial detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

445 records · Page 10Linked to original sources

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54 nM (S/N = 3) within a linear range of 0.2-12 μM. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

OBJECTIVES: Imaging diastolic dysfunction in pre-clinical heart failure (HF) is challenging. We evaluated a novel cardiac MRI (CMR) biomarker, CMR e-prime (CMR-MARV), in patients at risk of HF. METHODS: In this substudy of the PARABLE trial (NCT04687111), 236 patients (71.6&#xa0;&#xb1;&#xa0;7.7&#xa0;years, 61.6% male) fulfilling trial-defined ALVDD citeria underwent CMR with measurement of mitral annular relaxation velocity (CMR-MARV) at four mitral annular anchor points. Diastolic strain rates from FT were also assessed. Twenty-five age- and sex-matched controls were included (73.8&#xa0;&#xb1;&#xa0;3.1&#xa0;years, 52% male). Group differences were tested with t-tests, diagnostic accuracy with ROC analysis, and predictors of diastolic dysfunction with adjusted logistic regression. RESULTS: Compared with controls, patients had significantly higher indexed maximal left atrial volume (LAVimax), LV end-diastolic and end-systolic volumes, and LV mass (all p&#xa0;<&#xa0;0.001). Of FT variables, only peak diastolic longitudinal velocity differed between groups (p&#xa0;<&#xa0;0.001). In multivariate models, CMR-MARV correlated with radial, circumferential, and longitudinal diastolic strain rates, radial and longitudinal diastolic velocities (all p&#xa0;<&#xa0;0.001), echocardiographic e' (r&#xa0;=&#xa0;0.20, p&#xa0;=&#xa0;0.007), LV mass (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), LAVimax (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), and NT-proBNP (r&#xa0;=&#xa0;-0.30, p&#xa0;<&#xa0;0.0001). LAVimax and CMR-MARV were strongly independently associated with ALVDD (AUC 0.89 and 0.76, respectively; p&#xa0;<&#xa0;0.0001). A combined model (LAVimax + CMR-MARV) achieved excellent discrimination (AUC 0.91, 95% CI 0.86-0.97, p&#xa0;<&#xa0;0.0001). Independent predictors included LAVimax, CMR-MARV, and peak diastolic longitudinal velocity (all p&#xa0;<&#xa0;0.001). CONCLUSION: CMR-MARV provides a simple cine-derived measure of longitudinal relaxation that correlates with established structural and biochemical markers of diastolic burden. Within an at-risk population, it offers incremental functional information beyond conventional parameters and may support multiparametric CMR phenotyping of preclinical diastolic dysfunction.

Aged

Phase-resolved functional lung MRI detects single-dose and sustained bronchodilator responses in COPD in a randomized crossover trial.

OBJECTIVES: To evaluate the effects of tiotropium/olodaterol (T/O) on phase-resolved functional lung (PREFUL) MRI parameters in hyperinflated chronic obstructive pulmonary disease (COPD) patients and examine correlations with conventional cardiopulmonary and hyperpolarized 129Xe MRI measures. MATERIALS AND METHODS: Retrospective subanalysis of a prospective, randomized, placebo-controlled, crossover trial with open-label extension. Thirty-two patients with moderate-to-severe COPD (61.5&#x2009;&#xb1;&#x2009;7.7 years; 17 men); 30 completed the MRI extension at 1.5&#x2009;T. PREFUL analysis yielded regional ventilation (RVent), flow-volume loop correlation metric (FVL-CM), normalized perfusion (QN), ventilation defect percentage (VDP), perfusion defect percentage (QDP), V/Q match metrics (VQM), and pulmonary pulse wave velocity (PWV; post-hoc parameter). Linear mixed-effects models tested treatment effects; correlations were evaluated with Spearman's rank and bootstrap 95% confidence intervals (95% CIs). RESULTS: PREFUL parameters improved after T/O single dose (SD) versus placebo, including improvements in FVL-CM by 4.1 percentage points (pp; 95% CI: 1.0 to 7.3 pp) and QN by 0.4 pp (95% CI: 0.2 to 0.6 pp) and reductions in VDP and QDP, with parallel gains in VQM(Non-Defect) (p&#x2009;<&#x2009;0.05). PWV decreased after multiple doses (-0.87&#x2009;m/s, 95% CI: -1.26 to -0.48&#x2009;m/s). PREFUL MRI baseline values showed significant correlations with pulmonary function tests, cardiac, dynamic contrast-enhanced and 129Xe MRI. SD treatment-induced absolute changes in VDP(FVL-CM) correlated with reductions in residual volume (&#x3c1;&#x2009;=&#x2009;0.41, 95% CI: 0.02 to 0.64). Further correlations were observed between PREFUL MRI and &#xb9;&#xb2;&#x2079;Xe-derived VDP, apparent diffusion coefficient, and compartment ratios. CONCLUSION: PREFUL MRI sensitively captured immediate SD T/O-induced improvements in V/Q parameters and dose-dependent PWV responses after sustained bronchodilation. KEY POINTS: Question Can phase-resolved functional lung (PREFUL) MRI sensitively capture immediate single-dose and sustain multi-dose effects of tiotropium/olodaterol on ventilation-perfusion and vascular function in COPD patients? Findings Tiotropium/olodaterol improved PREFUL MRI-derived ventilation, perfusion, and V/Q matching parameters after a single dose, with sustained pulmonary vascular improvements after repeated dosing. Clinical relevance PREFUL MRI detected immediate and sustained functional improvements after tiotropium/olodaterol and showed significant correlations with cardiopulmonary tests and hyperpolarized &#xb9;&#xb2;&#x2079;Xe MRI, supporting its role as a sensitive, radiation-free tool for monitoring COPD treatment response.

Humans

A smartphone-integrated Pt@Cu-HCF nanozyme-based paper sensor for on-site determination of total antioxidant capacity in marine oils.

Total antioxidant capacity (TAC) serves as a key indicator for evaluating the nutritional quality of foods. In this study, we designed a platinum-embedded copper hexacyanoferrate (denoted as Pt@Cu-HCF) nanozyme that exhibits high oxidase-like activity, efficiently catalyzing the oxidation of chromogenic substrates to generate robust colorimetric signals. Antioxidants quench hydroxyl radicals (&#x2219;OH) produced during the catalytic process, leading to a concentration-dependent suppression of the color signal. Leveraging this mechanism, a smartphone-integrated, colorimetric paper sensor for on-site TAC quantification was developed, using vitamin E as the calibration standard. The sensor was applied to determine TAC in fish oil, algal oil, and krill oil, demonstrating a linear response range of 9.78-312.5&#xa0;&#x3bc;M and a limit of detection (LOD) of 6.41&#xa0;&#x3bc;M. Validation using real-world marine oil samples showed excellent agreement with a commercial assay kit, confirming the reliability and practical applicability of this portable sensor for TAC measurement in complex biological matrices.

Antioxidants

Saliva-based RT-LAMP assays support heat shock protein 70 as a promising transcript marker for estrus identification in buffaloes.

Buffaloes do not exhibit overt estrus signs particularly during summer, leading to a significant economic loss to farmers. Previous studies have identified several candidate transcripts (HSP70, TIMP1, TLR4 and HSD17B1), abundant in buffalo saliva during estrus stage. However, there is no widely applicable technology for estrus detection targeting these transcripts. Therefore, the present study aimed to develop reverse transcription loop mediated isothermal amplification (RT-LAMP) assays for these candidate transcripts using buffalo saliva. Saliva samples were collected from 10 cyclic buffaloes and RT-LAMP assays were optimized for salivary RNA as well as direct saliva. Among the four candidate transcripts, HSP70 showed a statistically significant colour change (p-value&#x2009;=&#x2009;0.0191) at the estrus stage compared to the diestrus stage. This abundance of HSP70 was also supported in large simulated population datasets (10,000 animals) generated using R. Further, the RT-LAMP assays were tested using direct saliva without RNA isolation, and the colour change in the samples during estrus suggested the feasibility of estrus identification using direct saliva, overcoming the tedious step of RNA isolation. The detection of HSP70 using either direct saliva or salivary RNA indicated its potential as a marker for estrus identification. Similarly, TLR4 appeared to be another potential biomarker for RT-LAMP reaction using direct saliva, but it needs further validation in both RNA and direct saliva samples. Overall, the proof-of-concept on RT-LAMP assays optimized for salivary transcripts in the present study would be useful for estrus identification in tropical production systems following further validation on a larger sample size.

Animals

Urinary Small Extracellular Vesicle DNA as a Biomarker for the Non-Invasive Diagnosis of Bladder Cancer.

Existing diagnostic technologies for bladder cancer (BC) suffer from low sensitivity, low specificity, or a lack of validation. Therefore, validated, non-invasive diagnostic biomarkers with high sensitivity and specificity for early detection of BC are needed to complement and improve upon the limitations of existing diagnostic methods. We used low-pass whole genome sequencing (LP-WGS) technology to detect copy number variations (CNVs) in small extracellular vesicle (sEV) DNA isolated from urine samples of patients. Based on these results, we constructed and validated a diagnostic model to differentiate between benign and malignant bladder lesions. We conducted a receiver operating characteristic analysis and calculated the area under the curve (AUC) to evaluate the performance of the diagnostic model. The urine sEV-DNA LP-WGS data revealed CNV differences between benign and malignant samples. The diagnostic model achieved an AUC of 0.953, a sensitivity of 86.7%, and a specificity of 100% in the training cohort and an AUC of 0.985, a sensitivity of 90%, and a specificity of 100% in the validation cohort. Even at the lowest coverage depth of 0.01X, the performance of the diagnostic model remained relatively robust. Notably, the performance of this diagnostic model surpassed that of the biomarker neuron-specific enolase (sensitivity: 85.7% vs. 64.3%; specificity: 100% vs. 87.5%) and urinary cytology (sensitivity: 100% vs. 66.7%; specificity: 100% vs. 94.1%). Our study demonstrates that urine sEV-DNA exhibits high discriminatory power in distinguishing between benign and malignant bladder lesions, making it a promising tool for auxiliary diagnosis of BC.

Humans

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Colorimetric gold nanosensors for monitoring protein aggregation: implications for Alzheimer's disease.

Alzheimer's disease (AD) is the leading cause of dementia worldwide. It remains a major public health challenge due to the lack of early diagnostic tools and effective disease-modifying therapies. Molecularly, AD is characterized by extracellular amyloid-&#x3b2; (A&#x3b2;) plaques and intracellular Tau tangles, as well as soluble oligomers that are likely the neurotoxic species. However, the transient and heterogeneous nature of these oligomers makes them difficult to detect using conventional biosensing approaches. Nanomaterial-based colorimetric biosensors have emerged as promising platforms for detecting protein aggregates and discovering aggregation inhibitors. Specifically, the localized surface plasmon resonance properties of metallic nanomaterials can enable rapid, label-free, and visually detectable colorimetric sensing of molecular interactions. These features can be leveraged to monitor protein aggregation processes in real time and achieve high-throughput screening of aggregation inhibitors, which may collectively enable early detection and timely intervention of AD progression. This Review Article presents the design and engineering of gold-nanomaterial-based colorimetric biosensors for monitoring protein aggregation and highlights the current challenges and emerging opportunities for applying these nanosensors to combat AD.

Journal Article

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

Non-destructive prediction of lead content in oilseed rape leaves by fluorescence hyperspectral technology based on neural network.

Based on fluorescence hyperspectral imaging (FHSI), this study targeted rapid, non-destructive quantification of lead (Pb) content in oilseed rape leaves treated with varying silicon (Si) concentrations, acquiring fluorescence spectra over the 484.43-1001.61&#xa0;nm wavelength range. To optimize spectral data quality, preprocessing methods (Savitzky-Golay smoothing, first derivative, detrending) were comprehensively compared. Characteristic wavelengths were then selected via interval variable iterative shrinkage, which effectively compressed data dimensionality and reduced computational load. A hybrid SE-CL1DA model, fusing a 1D convolutional neural network, a long short-term memory network and SE attention mechanism was constructed, with Bayesian optimization tuning hyperparameters to boost stability. The BO-SE-CL1DA outperformed both traditional machine learning and insufficiently optimized deep learning model (Rp2=0.9609, RMSE&#xa0;=&#xa0;0.0377&#xa0;mg/kg, RPD&#xa0;=&#xa0;5.1736), thus enabling accurate Pb estimation, supporting Si-regulated heavy metal stress management and facilitating agricultural contamination monitoring.

Plant Leaves

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Influenza A virus in Swiss pig herds with respiratory disease: Seasonality and age dependence.

Influenza A virus (IAV) is an important respiratory pathogen in pigs and poses a zoonotic risk to humans in close contact. While IAV epidemiology has been extensively studied in large-scale production systems, data from Switzerland - characterized by small herds and limited live pig imports - remain scarce. This exploratory nationwide cross-sectional study aimed to assess the association between herd-level IAV detection and reported respiratory disease in pig herds, and to explore associations with husbandry-, animal-, and human health-related factors. Between November 2023 and April 2025, 25 Swiss pig herds with caretaker-suspected respiratory symptoms were investigated. In each herd, five nasal swabs were collected and analyzed by quantitative PCR. Herd managers completed an interview, and clinical examinations were performed. Overall, 56&#x2009;% (95&#x2009;% CI: 37,1 - 73,3) of herds tested positive for IAV, comparable to reports from other European countries. The estimated intra-herd detection rate was 49,6&#x2009;% (95&#x2009;% CI: 31,2 - 68,0). Respiratory disease outbreaks associated with IAV detection showed indications of seasonal variation, with no positive herds identified during summer. Across age groups, pigs aged 11-14 weeks had a higher likelihood of IAV detection, with 15,79-fold increased odds (95&#x2009;% CI: 1,50 - 860,4), although with considerable uncertainty. The interpretation is limited by the small sample size, heterogeneous data, and reliance on single time-point qPCR detection. The results suggest that IAV detection in clinically apparent respiratory outbreaks may follow seasonal patterns in Swiss pig herds. Weaners and newly introduced fattening pigs may play a role in such respiratory outbreaks and could represent relevant targets for IAV surveillance in Switzerland. Continued monitoring and the implemen tation of appropriate control measures remain important given the virus's zoonotic potential and impact on pig health.

Animals

Microbial signal profiles and organism-level concordance between plasma metagenomic sequencing and blood culture in suspected bloodstream infection.

Plasma metagenomic next-generation sequencing (mNGS) and blood culture detect different components of the microbial signal and frequently produce discordant organism reports. We characterized microbial signal class, report-derived burden, organism-level concordance, and independent clinical attribution in a retrospective, single-center, episode-level cohort. Among 329 episodes with evaluable plasma mNGS reports, 315 had blood culture performed; 232 were mNGS positive/culture negative and 53 were positive by both methods. In the 232 discordant episodes, the recorded routine-care diagnosis classified 124 as bloodstream infection (BSI) and 108 as non-BSI. Nonviral signals were present in 78.2% and 42.6%, respectively (P&#x2009;<&#x2009;0.001), and median maximum report-derived sequence counts were 98.5 and 11.5 (P&#x2009;<&#x2009;0.001). Two laboratory physicians then independently reviewed source records using structured criteria while masked to the recorded BSI label and mNGS organism and sequence-count information. Initial agreement for the five-category BSI assessment was 97.6% (Cohen's kappa, 0.960). Within the mNGS-positive/culture-negative subgroup, adjudicated BSI likelihood showed a modest ordinal association with report burden (Spearman rho&#x2009;=&#x2009;0.190; P&#x2009;=&#x2009;0.004), while mNGS organisms were considered supported in 1 episode, plausible in 158, unlikely or contaminant in 72, and unresolved in 1. Among 53 dual-positive episodes, 33 (62.3%) shared at least one species, but only 5 (9.4%) had complete species-set concordance. Plasma mNGS and blood culture therefore frequently generated non-equivalent organism sets. Signal class and report burden contributed graded contextual evidence, but organism-level attribution required clinical review and orthogonal microbiology rather than binary positivity alone.

Humans

Assessment of atypical glandular cell interpretation in Pap tests using the Hologic Genius Digital Diagnostics System.

Atypical glandular cells (AGC) are a diagnostic challenge. The aim of this study was to evaluate the efficacy and diagnostic performance of AGC detection on the Hologic Genius Digital Diagnostics System (HGDDS). A retrospective analysis of 451 ThinPrep Pap cases was conducted, including 207 cases of AGC, 27 cases of high-grade squamous intraepithelial lesion (HSIL), 25 cases of low-grade squamous intraepithelial lesion (LSIL), and 192 benign cases. All AGC cases had follow-up histologic diagnoses, with 66 cases subsequently diagnosed as adenocarcinoma. The slides were randomized, scanned, and analyzed by the HGDDS. Patient age and HPV test results were provided to reviewers, an experienced cytologist, who screened the cases, followed by two cytopathologists who independently examined the cases on the HGDDS. Diagnostic concordance between the two cytopathologists indicated strong agreement (&#x3ba; = 0.829). Sensitivity of AGC on Papanicolaou (Pap) tests for adenocarcinoma detection on HGDDS was 98.5% and 95.5%, respectively, comparable to the original ThinPrep interpretation (OTPI). Specificity for adenocarcinoma detection was significantly higher (84.6% and 85.6%) with the HGDDS than 27.7% with OTPI. Overall, the diagnostic performance for AGC/HSIL interpretation to detect CIN2/3/adenocarcinoma appeared to have improved with HGDDS compared with OTPI, particularly for specificity and positive predictive value (PPV). This is the first study evaluating AGC diagnosis using the HGDDS. The findings demonstrate that the sensitivity of adenocarcinoma detection as AGC on HGDDS is comparable to the ThinPrep Imaging System, but the specificity and PPV are improved. This suggests the potential of artificial intelligence to augment the performance of cervical cancer screening.

Humans

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Selective monitoring of trace-level catechin and myricetin in herbal and aqueous matrices using magnetic MIP-DSPME: Optimization via design of experiments.

A novel dispersive solid-phase microextraction approach utilizing a magnetic molecularly imprinted polymer (MMIP) integrated with HPLC-UV detection was developed for the concurrent quantification of catechin and myricetin in herbal extracts and aqueous samples. The sorbent was engineered as a core-shell nanocomposite, consisting of a selective polymer layer deposited onto Fe3O4@SiO2-APTMS magnetic nanoparticles. Dual-template imprinting using catechin and myricetin generated complementary binding cavities within the polymer framework. Experimental variables influencing extraction were systematically screened and subsequently optimized. A Plackett-Burman design was first applied to identify the most influential factors, with pH and sorption time identified as the dominant variables. These parameters were subsequently fine-tuned using a central composite design, and the optimization process was completed in only 30 experimental runs. The sorption characteristics of the imprinted sorbent (MMIP) were compared with those of its non-imprinted counterpart (MNIP). The MMIP demonstrated markedly higher maximum binding capacities (Qmax), reaching 119.3&#xa0;mg&#xa0;g-1 for myricetin and 112.1&#xa0;mg&#xa0;g-1 for catechin, whereas the corresponding values for the MNIP were 32.55 and 32.08&#xa0;mg&#xa0;g-1, respectively. Moreover, the affinity constants (KL&#xa0;=&#xa0;0.760-0.950&#xa0;L&#xa0;mg-1) were approximately 2.3-fold higher for the MMIP, confirming its stronger and more selective interactions with the target analytes. The selectivity coefficients for the targeted flavonoids relative to structurally related compounds, including ferulic acid, p-coumaric acid, melatonin, and curcumin, exceeded 3.5 for the MMIP, whereas the corresponding values for the MNIP were close to 1.1, demonstrating the high molecular recognition capability of the imprinted sorbent. Method validation demonstrated limits of detection (LODs) of 0.33-0.59&#xa0;ng&#xa0;mL-1 and limits of quantification (LOQs) of 1.10-1.96&#xa0;ng&#xa0;mL-1, and excellent linearity over the concentration range of 5.0-5500&#xa0;ng&#xa0;mL-1 (R2&#xa0;>&#xa0;0.998). The method achieved recoveries of 93.96% to 105.69% with RSDs below 5.5%, while the preconcentration factors ranged from 209 to 229. Furthermore, the sorbent retained more than 95% of its extraction efficiency after four consecutive reuse cycles and more than 80% after six cycles, demonstrating excellent stability and reusability. The proposed method was successfully applied to the analysis of six medicinal plant extracts and water samples, showing negligible matrix interference and superior sensitivity, selectivity, and operational simplicity compared with conventional solid-phase extraction methods.

Flavonoids