Abstract

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically ≤0.03 s; spatial parameters generally ≤0.03 m). For joint kinematics during overground walking, median SEMs were 2.4° (sagittal), 1.9° (frontal), and 3.3° (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Explore related subjects

Keep this discovery

BibTeXRIS

Brian Horsak, Andreas Kranzl, Djordje Slijepcevic, Martin Svehlik, Bernhard Dumphart. 2026-06-29. Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.. https://doi.org/10.1016/j.gaitpost.2026.110270

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Barefoot ambulation following partial foot amputation: A systematic review of biomechanical outcomes.

BACKGROUND: Partial foot amputation (PFA) is increasingly performed due to rising prevalence of diabetes and peripheral vascular disease. While PFA may preserve gait and reduce energy expenditure compared with transtibial amputation, biomechanical deficits are common. This review aimed to evaluate biomechanical outcomes during baref following PFA. METHODS: A systematic review was conducted. MEDLINE, Embase, CINAHL, SCOPUS and Web of Science databases were searched for studies reporting biomechanical outcomes in adults with PFA without prosthesis. Eligible outcomes included spatiotemporal metrics, joint kinematics and kinetics, plantar pressures, and ground reaction forces. FINDINGS: Twelve studies including a total of 101 participants met inclusion criteria. Across studies, PFA was associated with impaired barefoot gait. This included spatiotemporal changes, such as reduced walking speed and shorter step length, and kinetic changes, such as reduced ankle power. Elevated plantar pressures were commonly reported, particularly in the forefoot and midfoot, highlighting loading abnormalities in the residuum. Several studies also described proximal compensatory strategies at the knee and hip, suggesting that biomechanical consequences extend beyond the foot and ankle. However, the evidence base was limited by small sample sizes, inconsistent protocols, and substantial heterogeneity. INTERPRETATION: Barefoot walking is impaired after partial foot amputation and the degree of dysfunction may vary by amputation level. Abnormal loading and compensatory changes may extend beyond the foot and ankle to the knee and hip. Given the limited and methodologically heterogeneous evidence, larger prospective studies with standardised biomechanical outcomes are needed to clarify the effects of amputation level and aetiology. This standardisation is important to inform surgical planning, rehabilitation, and prosthetic device design.

Humans

Optimizing focal vibration therapy for balance and gait: A systematic review.

OBJECTIVE: This systematic review evaluated the efficacy of focal (localized) vibration therapy (FVT) applied to muscles/tendons on balance, gait, and mobility, with a specific focus on defining optimal vibration protocols (frequency, amplitude, dosing) and muscle-targeting strategies to maximize sensorimotor recovery. METHODS: A systematic review was conducted across six databases (CINHAL, Embase, Medline, Web of Science, Scopus, CENTRAL) from January 2000 to May 2025. Studies were included if they involved human participants, applied FVT therapeutically, and reported balance, gait, or mobility outcomes. Data extraction included study characteristics, intervention protocols, and outcomes. Methodological quality was assessed using the PEDro scale. RESULTS: Sixty-two studies (n = 2090 participants) were included. Methodological quality assessment (PEDro scale) indicated 44% of studies met high-quality standards. Biomechanical analysis identified the quadriceps, gastrocnemius/soleus, and plantar muscles as the most effective vibration sites, given their critical roles in gait propulsion and postural stability. The synthesis of protocol data indicated a promising therapeutic window characterized by a vibration frequency of 80-120 Hz (primarily fixed sinusoidal waveforms at a single frequency) and an amplitude of 0.2-0.5 mm (reported only in 12 studies; amplitude was not reported in 23 studies), applied bilaterally for a minimum of 3 sessions per week over 4-12 weeks, which could lead to improved balance and gait performance with benefits sustained for up to 5 months. CONCLUSION: FVT shows potential to improve gait and balance, particularly when targeting lower-extremity muscles with optimized vibration parameters. To advance the field, future research must prioritize the development of standardized protocols and investigate neurophysiological mechanisms to refine FVT as a precision bioengineering solution for mobility deficits.

Humans

Improved donor-site biomechanics and functional recovery with xenogeneic acellular dermal matrix after ALT flap harvest: A prospective randomized controlled study.

BACKGROUND: Donor-site management after anterolateral thigh (ALT) flap harvest is a significant yet underaddressed concern in reconstructive surgery for oral cancer. While xenogeneic acellular dermal matrix (Xeno-ADM) is common in soft-tissue repair, its efficacy for fascia lata reconstruction at the ALT donor site remains insufficiently characterized. This study aimed to assess the efficacy of xeno-ADM in fascia lata repair, focusing on compartment pressure, inflammatory and muscle injury biomarkers, and functional recovery. METHODS: In this prospective, randomized, single-blind trial, 200 patients undergoing ALT flap reconstruction were allocated to Xeno-ADM repair (n = 100) or primary closure (n = 100). Primary endpoints included compartment pressure, inflammatory markers in drainage fluid, serum muscle injury biomarkers, and functional outcomes. RESULTS: The xeno-ADM group showed significantly lower compartment pressures throughout postoperative days (POD) 1-5. Inflammatory markers in drainage fluid (CRP on POD 3 and 5) and serum muscle injury biomarkers (creatine kinase on POD 1 and 5) were significantly lower in xeno-ADM group. Functional outcomes were superior in the Xeno-ADM group, with faster gait recovery, lower pain scores at POD 7, and better lower-limb function at the 1- and 6-month follow-ups. Drainage duration did not differ between groups. Stratified analyses revealed that the benefits of xeno-ADM were more pronounced in patients with defect width >3 cm or a body mass index ≥24 kg/m2. CONCLUSION: Xeno-ADM provides a safe and effective approach for fascia lata repair, reducing biomechanical and inflammatory burdens while enhancing functional recovery. These findings support a transition from simple structural closure toward functional donor-site reconstruction.