Search PubMedSearch

SEARCH · Search PubMed

Results for “bi-flanged metal stents”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

62 recordsLinked to original sources

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n  = 627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Humans

Efficacy and safety of endoscopic ultrasound-guided choledochoduodenostomy compared with endoscopic ultrasound-guided gallbladder drainage for palliation of malignant distal biliary obstruction: a systematic review and meta-analysis.

BACKGROUND AND AIMS: When ERCP is not feasible or fails in the palliation of malignant distal biliary obstruction (MDBO), EUS-guided choledochoduodenostomy (EUS-CDS) and EUS-guided gallbladder drainage (EUS-GBD) are viable alternatives. We conducted a systematic review and meta-analysis comparing the safety and efficacy of the 2 techniques for the palliation of MDBO. METHODS: Multiple databases were searched through November 2025 for studies that reported outcomes of EUS-CDS and EUS-GDB in patients with MDBO. A meta-analysis was performed to determine pooled proportions and relative risk (RR) with 95% CIs. We compared the rates of technical and clinical success, overall adverse events (AEs), and lumen-apposing metal stent dysfunction. A random-effects model was used for our meta-analysis, and heterogeneity was assessed using the I2 (%) statistics. RESULTS: Five studies (352 patients; EUS-CDS: 193 and EUS-GBD: 159) were included. Technical success was 93.3% (95% CI, 70.6-98.8) for EUS-CDS and 95.9% (95% CI, 90.0-98.4) for EUS-GBD (RR, 1.02; 95% CI, 0.94-1.10; P = .6). Clinical success was 90.1% (95% CI, 84.7-93.7) versus 86.6% (95% CI, 80.3-91.0) (RR, 0.97; 95% CI, 0.90-1.05; P = .4). There were no significant differences in overall AEs (19.7% vs 17.6%; RR, 0.93; 95% CI, 0.58-1.48; P = .8), severe AEs (11.0% vs 8.3%; RR, 0.69; 95% CI, 0.33-1.44; P = .3), or stent dysfunction (15.0% vs 14.5%; RR, 0.95; 95% CI, 0.35-2.58; P = .9). CONCLUSIONS: EUS-GBD appears comparable to EUS-CDS in terms of technical and clinical success, AEs, and stent dysfunction. Further prospective studies are warranted to corroborate our findings.

Humans

Comparative effectiveness of percutaneous coronary intervention strategies for coronary small-vessel disease: a network meta-analysis of randomized trials.

BACKGROUND: Coronary small-vessel disease (SVD) remains challenging for percutaneous coronary intervention (PCI) because small lumens magnify restenosis and ischemic risk. Multiple devices are available, yet their comparative performance is uncertain. This study evaluated and ranked PCI strategies for SVD. METHODS: A systematic review and network meta-analysis was conducted in accordance with PRISMA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar were searched from inception to 15 August 2025. Eligible studies were English-language randomized controlled trials enrolling adults with angiographic SVD defined as reference vessel diameter ≤3.0 mm, comparing PCI strategies, and reporting target lesion revascularization (TLR), binary restenosis (BR), or myocardial infarction (MI). A frequentist random-effects network meta-analysis generated odds ratios (ORs) with 95% confidence intervals (CIs) and treatment rankings using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirty-nine trials including 14,503 patients met the criteria. For TLR (37 studies; 11,980 patients), the highest SUCRA values were observed with sirolimus-eluting stents (SES 90.1%), zotarolimus-eluting stents (ZES 83.9%), and everolimus-eluting stents (EES 82.2%). For BR (32; 6,468), SES, ZES, and paclitaxel-coated balloons (DCB-PTX) ranked highest (95.0%, 80.0%, and 78.3%). For MI (37; 11,602), SES, DCB-PTX, and ZES ranked highest (79.0%, 78.7%, and 68.5%). Representative effects showed SES reduced TLR versus bare-metal stents (BMS) (OR, 0.25; 95% CI, 0.15-0.43) and MI versus BMS (OR, 0.41; 95% CI, 0.21-0.79). Conventional approaches such as BMS, plain old balloon angioplasty (POBA), and gold-plated balloon angioplasty (GPBA) ranked lowest across outcomes. CONCLUSION: SES provides the most consistent clinical benefit for coronary SVD. ZES, EES, and DCB-PTX are effective alternatives in selected settings, whereas BMS, POBA, and GPBA are less effective. These findings offer comparative evidence to guide device selection in SVD.

Humans

Advanced/Novel Stenting for Pediatric Dynamic Airway Collapse.

Pediatric dynamic airway collapse is a complex condition that can impact all levels of the pediatric airway. These conditions can pose life threatening risk to pediatric patients and carry lasting impacts. While traditionally, tracheostomy has been used to address all levels of dynamic collapse, recent advances have allowed for more individualized, anatomy-specific stenting and splinting strategies for treatment. This article covers pathophysiology and the latest evidence on strategies to address nasopharyngeal, oropharyngeal, proximal trachea, and tracheobronchial dynamic collapse.

Humans

A stent-plus-irrigation protocol after adolescent hypospadias repair: a multicentre randomised controlled trial.

OBJECTIVES: To evaluate whether a stent-plus-irrigation protocol reduces complication rates following hypospadias repair in adolescents compared with catheter drainage alone. PATIENTS AND METHODS: In this multicentre randomised controlled trial, adolescents (Tanner Stage II-V) undergoing hypospadias repair were randomly assigned to either a stent-plus-irrigation group or a catheter-drainage group. The catheter-drainage group received standard urethral catheter drainage alone, whereas the stent-plus-irrigation group received an additional small-calibre urethral stent positioned within the reconstructed urethra and twice-daily saline irrigation. The primary outcome was the overall postoperative complication rate; secondary outcomes included urinary function and cosmetic outcomes. RESULTS: A total of 172 adolescents were assessed for eligibility, with 150 participants (75 in the stent-plus-irrigation group and 75 in the catheter-drainage group) included in the final analysis. Compared with the catheter-drainage group, the stent-plus-irrigation group demonstrated a significantly lower overall complication rate (risk ratio [RR] 0.33, 95% confidence interval [CI] 0.20-0.56; P&#x2009;<&#x2009;0.001), urethral fistula rate (RR 0.27, 95% CI 0.14-0.51; P&#x2009;<&#x2009;0.001), and surgical site infection (SSI) rate (RR 0.43, 95% CI 0.21-0.87; P&#x2009;=&#x2009;0.020). CONCLUSIONS: A postoperative stent-plus-irrigation protocol was associated with lower rates of postoperative complications, particularly urethral fistula and SSI, compared with catheter drainage alone after adolescent hypospadias repair. Because the intervention included both an additional urethral stent and saline irrigation, the independent contribution of irrigation cannot be determined in this two-arm trial.

Humans

Feasibility of implementation, diagnostic accuracy, and end-user impact of an electronic health record (EHR)-based ureteral stent tracking tool in a pediatric population.

INTRODUCTION & OBJECTIVES: Ureteral stent tracking systems have reduced stent retention in adults, but their accuracy and impact in pediatrics have been minimally explored. With low event rates in children, such tools may yield high false positives, raising questions on balancing event prevention with provider burden. We aimed to evaluate the feasibility, diagnostic accuracy, and end-user impact of an Electronic Surveillance Tool for Evaluating Nephroureteral stent Tracking (eSTENT) at our institution. STUDY DESIGN: eSTENT, implemented in 1/2024, flags ureteral stents at risk for retention based on implant documentation, expected explant date, and explant documentation. Monthly reports are generated for stents missing explant documentation. We retrospectively evaluated the diagnostic performance of eSTENT from 1/2024-8/2025 at our pediatric hospital. A usability survey including a validated 1-7 implementation score (higher = easier implementation) was distributed to pediatric urologists and operating room nurses. RESULTS: Of 172 cases with ureteral stent placement, eSTENT flagged 28 events (16%) in 24 patients. Of these, 26 represented documentation gaps where explant had been appropriate. Two flags had no documentation of explant, representing near miss events that were identified. No retained stents occurred, consistent with high sensitivity and modest specificity. There were no flags in the last 6 months of the study period. Survey response rate was 100% for surgeons and 55% for nurses. Before eSTENT, stents were not routinely tracked. All surgeons and 93% of nurses reported no added burden, despite occasional misidentification of retained stents. Three surgeons found eSTENT beneficial, four were neutral, and free-text responses generally cited eSTENT's "fail safe" nature as positive. Nurses suggested improvements, including user support and integrated documentation reminders. The average implementation score among both groups was 6/7, indicating easy adoption. DISCUSSION: While the impact of stent tracking tools in adult literature has been positive, our study emphasizes the feasibility of broader adoption at a pediatric hospital. Integration of eSTENT may avoid the potentially devastating consequences of a retained stent. Prioritizing sensitivity over specificity appears acceptable for a "never event" in patient safety. Our study is limited by the retrospective nature of data collection and survey bias. CONCLUSIONS: Though no stents were retained in the study period, eSTENT appropriately flagged two cases without added burden to most end-users. Further optimization is warranted, but adoption in pediatric centers may enhance care reliability.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

ORBIT: Oncogenic Representation Learning via Bi-Prototype Contrastive Learning in Hyperbolic Space for cancer driver gene identification.

Accurate identification of cancer driver genes is crucial for precision oncology but remains challenging due to the complexity of integrating heterogeneous data and modeling dynamic biological systems. To address these limitations, we propose ORBIT (Oncogenic Representation Learning via Bi-Prototype Contrastive Learning in Hyperbolic Space). Our framework synergistically fuses multi-omics profiles with functional network data using a context-adaptive graph reweighting mechanism to capture cancer-specific dynamics. The model employs a bi-prototype contrastive learning strategy within hyperbolic space, which aligns gene representations around distinct driver and non-driver semantic anchors while preserving the intrinsic hierarchy of biological networks. Comprehensive evaluations demonstrate that ORBIT achieves highly competitive stability in pan-cancer analysis while consistently outperforming state-of-the-art methods in cancer-specific predictions. Furthermore, functional enrichment analysis confirms that the model effectively segregates core cancer pathways, and drug sensitivity profiling validates the clinical relevance of the identified drivers. By integrating hyperbolic geometry with context-adaptive learning, ORBIT offers a robust and interpretable paradigm for precision medicine. The source codes and datasets are publicly accessible at https://github.com/spcho-dev/ORBIT.

Humans

Venous Sinus Stenting for Pulsatile Tinnitus: A Systematic Review and Meta-Analysis.

BACKGROUND: Pulsatile tinnitus (PT) is frequently caused by venous sinus stenosis and may be associated with idiopathic intracranial hypertension (IIH). Venous sinus stenting (VSS) directly addresses venous outflow obstruction and has emerged as a therapeutic option; however, outcome data remain heterogeneous. We performed an updated systematic review and meta-analysis to evaluate the efficacy and durability of VSS for PT and to compare outcomes between IIH-associated and isolated PT. METHODS: MEDLINE, Scopus, and Web of Science were searched from inception through December 2025 following PRISMA guidelines. Clinical studies reporting PT outcomes after VSS were included. Random-effects meta-analyses of proportions were conducted to estimate pooled rates of overall improvement, complete resolution, and recurrence. Prespecified subgroup analyses compared IIH versus isolated PT. RESULTS: Thirty-two studies comprising 850 patients were included (641 with IIH; 209 with isolated PT). Venous sinus stenosis accounted for 90.3% of treated etiologies. The pooled rate of overall PT improvement was 89.8% (95% CI, 85.5-92.9). Complete resolution occurred in 87.1% (95% CI, 82.5-90.6). Recurrence at last follow-up was 10.9% (95% CI, 8.3-14.2). Improvement and complete resolution rates did not differ significantly between IIH and isolated PT. Recurrence was higher in IIH (12.0%) than in isolated PT (5.7%), without reaching statistical significance. CONCLUSIONS: VSS is associated with high rates of PT improvement and complete resolution with low recurrence. Recurrence trends appear higher in IIH, suggesting underlying pathophysiology may influence durability.

Humans

Bi-compartmental CSF-serum analysis of NfL and GFAP differentiates central and peripheral pathology in neuroinfectious diseases: A monocentric real-world cohort study.

Neurofilament light chain (NfL) and glial fibrillary acidic protein (GFAP), established biomarkers of neuroaxonal injury and astroglial pathology, are frequently only assessed in blood, which limits conclusions regarding their origin. Bi-compartmental analyses of CSF and serum may help differentiate central or peripheral origin of biomarker elevation. Moreover, studies on NfL and GFAP in distinct neuroinfectious disease (NID) phenotypes, particularly those based on real-world cohorts, are limited. This retrospective monocentric study analyzed CSF and serum from patients with (meningo-)encephalitis/myelitis (TI+; n&#xa0;=&#xa0;48), meningitis (TI-; n&#xa0;=&#xa0;80), (cranial) nerve palsies/polyradiculitis (PND; n&#xa0;=&#xa0;61), and 113 non-neuroinflammatory/non-neurodegenerative controls. A bi-compartmental model using scatter plots and simple linear regression was applied to assess the origin of blood biomarker levels and discriminate between central and peripheral pathology. CSF and serum NfL and GFAP z-scores were significantly higher in TI+ compared with TI- (CSF-GFAP p&#xa0;<&#xa0;0.001/sGFAP p&#xa0;=&#xa0;0.0083; CSF-NfL p&#xa0;=&#xa0;0.003/sNfL p&#xa0;=&#xa0;0.0004). TI+ and PND differed only in GFAP levels, which were higher in TI+ (CSF-GFAP p&#xa0;=&#xa0;0.0049/sGFAP p&#xa0;=&#xa0;0.003). The overall group effect (p&#xa0;&#x2264;&#xa0;0.003) and principal findings remained significant after adjustment for age, sex, QAlb, and time since (symptom) onset to LP. Bi-compartmental analysis revealed simultaneous elevation of CSF and serum NfL in TI+, indicating predominantly central origin, whereas PND demonstrated a shift toward higher sNfL levels suggesting peripheral origin. Higher clinical severity (modified Rankin Scale 3-5) was associated with elevated serum and CSF GFAP and NfL (sGFAP p&#xa0;=&#xa0;0.012/sNfL p&#xa0;=&#xa0;0.002; CSF-GFAP p&#xa0;<&#xa0;0.0001/CSF-NfL p&#xa0;=&#xa0;0.0001), which also predicted unfavorable outcome at discharge (sGFAP p&#xa0;=&#xa0;0.006/sNfL p&#xa0;=&#xa0;0.004; CSF-GFAP p&#xa0;=&#xa0;0.003/CSF-NfL p&#xa0;=&#xa0;0.012). NfL and GFAP were associated with brain/myelon involvement in NID, predominantly reflecting central pathology. Despite strong CSF-serum correlations, bi-compartmental approaches provide additional insight into biomarker origin and disease compartment.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

A 7-mm Covered TIPS Reduces&#xa0;Hepatic Encephalopathy Without Increasing Rebleeding in Cirrhotic Patients With Small Liver: A Randomized Study.

BACKGROUND/AIMS: International guidelines recommend initiating transjugular intrahepatic portosystemic shunt (TIPS) placement with an 8-mm stent. However, there is an evident lack of randomized controlled trials evaluating TIPS diameters <&#x2009;8&#x2009;mm in cirrhotic patients with a relatively small liver. The aim of this study was to determine whether 7&#x2009;mm-covered TIPS, compared with 8-mm stents, could achieve comparable shunt function with a lower incidence of hepatic encephalopathy (HE). METHODS: In this multicenter randomized controlled trial, patients with cirrhosis and relatively small liver were randomized 1:1 to receive TIPS with a 7-mm (n&#x2009;=&#x2009;92) or 8-mm (n&#x2009;=&#x2009;92) covered stent to prevent variceal rebleeding. The primary endpoint was the incidence of overt HE after randomization. All-cause rebleeding, orthotopic liver transplantation (OLT)-free survival and a composite of these outcomes, were designated as secondary endpoints. RESULTS: Among the 184 enrolled patients, the predominant etiologies of liver cirrhosis were hepatitis B virus infection (56.0%) and alcohol-related liver disease (20.7%). Over a median follow-up of 26.5&#x2009;months, overt HE occurred in 19 patients (20.7%) in the 7-mm group and 33 patients (35.9%) in the 8-mm group. The 2-year cumulative incidence of overt HE was significantly lower in the 7-mm group than in the 8-mm group (21.4% vs. 37.2%, p&#x2009;=&#x2009;0.02). Stent diameter, post-TIPS portosystemic pressure gradient, pre-covert HE and MELD-Na score were identified as independent risk factors for overt HE. The rates of shunt dysfunction were statistically similar between groups (8.7% vs. 8.7%, p&#x2009;=&#x2009;1.0), as were 2-year rebleeding rates (10.9% vs. 9.8%, p&#x2009;=&#x2009;0.81) and OLT-free survival rates (91.3% vs. 88.0%, p&#x2009;=&#x2009;0.82). CONCLUSIONS: A 7-mm covered TIPS demonstrated comparable shunt function to an 8-mm covered stents, with a significantly lower risk of overt HE. These findings support consideration of 7-mm TIPS stents for preventing variceal rebleeding in cirrhotic patients with a small liver who are undergoing TIPS. TRAIL REGISTRATION: ClinicalTrials.gov, NCT02541825.

Humans

Human iPSC-EV-loaded nanofiber stent coatings accelerate vascular repair by enhancing EGFR/HIF-1&#x3b1; signaling and suppressing ROCK1-mediated remodeling.

Arterial disease management is shifting from antiproliferative drug-eluting stents toward approaches that restore endothelial function and modulate smooth muscle cell (SMC) behavior. Stem cell-derived extracellular vesicles (EVs) carry miRNAs that promote endothelial proliferation and migration while restraining aberrant SMC growth and inflammation. Here, human induced pluripotent stem cell (iPSC)-derived EVs were collected by ultracentrifugation and incorporated into 50:50 poly (lactic-co-glycolic acid) (PLGA 503) core-shell nanofibrous membranes, which were fabricated as stent coatings for sustained release to overcome rapid clearance and poor tissue retention. EVs derived from three independent iPSC lines all enhanced tube formation in human umbilical vein endothelial cells (HUVECs) under hypoxic and serum-starved conditions and revealed a trend toward reduced platelet-derived growth factor-BB (PDGF-BB)-induced smooth muscle cell (SMC) migration. The fabricated core-shell nanofibers enabled sustained EV release, maintaining therapeutic efficacy for 28 days. Small RNA sequencing (NGS) analysis demonstrated that EVs from these independent iPSC lines shared miR-148a-3p and members of the miR-92 family, which collectively accounted for more than 75% of the reads within the 25 top-expressed miRNA set. In vitro, iPSC-EVs enhanced HUVEC proliferation and survival signaling by downregulating the negative regulators ERRFI1 and VHL, which are specific targets of miR-148a-3p and the miR-92 family, thereby activating the EGFR and HIF-1&#x3b1; axes and driving downstream ERK1/2 and VEGF expression under hypoxic and serum starvation stress conditions. Concurrently, iPSC-EVs prevented PDGF-BB-induced SMC phenotypic switching by downregulating ROCK1, a target of miR-148a-3p, thereby inhibiting downstream AKT and ERK signaling and preserving contractile markers while suppressing the synthetic phenotype. In vivo, the iPSC-EV-functionalized scaffolds significantly accelerated re-endothelialization and inhibited neointimal hyperplasia, evidenced by the upregulation of angiogenic factors (VEGF, CD31) and the concurrent suppression of pathological remodeling markers (&#x3b1;-SMA, MMPs) and inflammatory cytokines (IL-6, TGF-&#x3b2;1). Therefore, iPSC-EVs enriched with specific miRNAs and delivered via PLGA 503 core-shell nanofibers promote endothelial repair while suppressing SMC overgrowth, providing a promising strategy for vascular healing.

Core-shell nanofibers

Aortoesophageal Fistula: Mending the Lethal Connection-A Systematic Review and Meta-Analysis.

BACKGROUND: Aortoesophageal fistula (AEF) is a rare, life-threatening condition with limited high-quality evidence to guide management. METHODS: We conducted a systematic review and meta-analysis of PubMed and Scopus through December 2025, evaluating survival and complication outcomes according to treatment strategy and morphological severity. Patients were categorized into 5 groups: TEVAR alone, staged TEVAR followed by surgery, primary open or hybrid surgery, TEVAR with esophageal stenting, and supportive/palliative care. Outcomes were pooled as proportions with 95% confidence intervals (CIs). RESULTS: A total of 167 reports representing 528 patients were included. Overall 30-day mortality was 31.2% (95% CI 27.0% to 35.7%) and 1-year mortality 41.2% (95% CI 36.2% to 46.4%). Infection occurred in 32.6%, reintervention in 20.2%, and recurrence in 13.2%. Staged TEVAR followed by surgery showed favorable survival (30-day 12.7%, 1-year 26.1%) but high infection (66.7%) and reintervention (43.2%) rates. TEVAR with esophageal stenting had the lowest early mortality (5.0%) but frequent reintervention (54.5%) and 1-year mortality of 33.3%. TEVAR alone demonstrated the lowest 1-year mortality among definitive strategies (25.5%) but notable recurrence (26.9%). Primary open or hybrid surgery carried higher early and late mortality, while supportive/palliative care had the worst outcomes. Morphological severity correlated strongly with mortality, infection, reintervention, and recurrence, with type IV lesions showing particularly poor prognosis. CONCLUSION: Despite contemporary management, AEF carries high early and late mortality. Definitive strategies, particularly staged TEVAR followed by surgery, offer improved survival but increased complications. Morphology-guided, individualized management is recommended.

Adult

Associations between multiple essential trace metal concentrations and risk of hyperuricemia: insights from a central Chinese population.

Previous studies have indicated that levels of individual essential trace metals are related to hyperuricemia (HUA), but evidence on their combined effects is limited. To address this gap,&#xa0;the associations of individual and joint levels of 12 essential trace metals (manganese, selenium, nickel, chromium, cobalt, tin, iron, molybdenum, zinc, strontium, vanadium, and copper) with the risk of HUA were investigated in&#xa0;2,021 adults recruited from Hunan Province, China. Inductively coupled plasma mass spectrometry (ICP-MS) was employed to determine urinary metal concentrations. Logistic regression, Bayesian kernel machine regression (BKMR), and quantile g calculation (Qgcomp) were applied to evaluate the associations of single and mixture metal concentrations with HUA. Of the participants,&#xa0;516 (25.53%) were diagnosed with HUA. Inverse associations were found between vanadium, chromium, manganese, iron, cobalt, selenium, strontium, and molybdenum levels and HUA, with ORs ranging from 0.63 to 0.91. Conversely, a positive association was observed between zinc concentration and HUA [OR (95% CI): 1.17 (1.01, 1.37)]. Both BKMR and Qgcomp models showed a negative overall effect of essential trace metals on HUA risk, with strontium (-&#x2009;43.6%) and vanadium (-&#x2009;27.8%) being the main contributors. In addition, formal interaction tests revealed significant effect modification by age for tin and by BMI for zinc.&#xa0;In conclusion, the levels of essential trace metals were linked to a decreased risk of HUA, and these associations were modified by age and BMI only for specific metals.

Humans

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

Biomonitoring of industrial heavy metal pollution via enzymatic and metabolic responses in desert ants (Cataglyphis savignyi) and beetles (Tentyrum sp) as bioindicators.

The current work seeks to evaluate the effectiveness of Cataglyphis saviginyi and Tentyrum sp as indicators of pollution in the city's main industrial regions by analyzing their enzymatic activity and primary metabolites. Soil samples were collected at each site under investigation to analyze soil characteristics and heavy metal content. C. saviginyi and Tentyrum sp were collected across four consecutive seasons (2023-2024) to investigate enzymatic (GPT, GOT, ALP, ACP, LDH) and metabolic (lipid, protein, carbohydrate) biomarkers. The physicochemical properties of the soil differed substantially between the industrial areas and the control site. Soil heavy metal buildup was highest at industrial sites (1 and 4) compared to the control site, with the order being Zn&#x2009;>&#x2009;Cr&#x2009;>&#x2009;Cd&#x2009;>&#x2009;Cu. Heavy metal pollution indices were determined. Increased industrial activity from metal industries, ceramics, and chemical painting companies defines this area, as seen by the high Cdeg, mCd, PI, and PLI values derived for industrial sites 1 and 4. While C. saviginyi and Tentyrum sp deconcentrated and released Cr, Cd, and Zn into the soil via the biological accumulation factor (BAF), Cu acted as a macro-concentrator. Compared with the control site, industrial environments were shown to increase levels of GPT, GOT, LDH, ACP, protein, and carbohydrates in C. saviginyi. However, lipid and ALP activity was suppressed. at industrial sites, Tentyrum sp carbohydrate content was higher than at control sites, but GPT, GOT, ALP, ACP, LDH, protein, and lipid activities were all suppressed. Consequently, enzymatic and metabolic biomarkers proved to be sensitive indicators for assessing industrial heavy metal pollution in desert ecosystems.

Animals

Leveraging environmental applications and risks of coal gangue: A critical review on authigenic inorganic heavy metals, organic contaminants, and the removal of exogenetic contaminants.

Coal gangue (CG) as bulk solid waste has seriously threatened the ecosystem. Therefore, identifying the key risk drivers and exploring feasible disposal methods for CG are essential for developing a sustainable strategy. However, there is currently a lack of comprehensive information that balances the contamination risks with the valuable constituents present in CG, which hinders its full potential for sustainable use without negative environmental impacts. Given the complex composition and associated risks, we propose that addressing the critical properties related to contamination is crucial for the efficient utilization of CG. On this premise, we summarized several practical resource pathways (ecological multifunctional materials, extraction of rare elements, and soil additives) that are more favorable for sustainable development relative to conventional disposals. Meanwhile, we also propose that coupling disposals could intensely reduce CG's environmental footprints and capital costs. Consequently, regardless of the number of challenges to be solved, we believe the CG has broad application prospects, and we hope this review will promote the conversion of CG into an asset with lower ecological and social impacts.

Metals, Heavy