Search PubMedSearch

PubMed · 42379126

Feasibility of implementation, diagnostic accuracy, and end-user impact of an electronic health record (EHR)-based ureteral stent tracking tool in a pediatric population.

Abstract

INTRODUCTION & OBJECTIVES: Ureteral stent tracking systems have reduced stent retention in adults, but their accuracy and impact in pediatrics have been minimally explored. With low event rates in children, such tools may yield high false positives, raising questions on balancing event prevention with provider burden. We aimed to evaluate the feasibility, diagnostic accuracy, and end-user impact of an Electronic Surveillance Tool for Evaluating Nephroureteral stent Tracking (eSTENT) at our institution. STUDY DESIGN: eSTENT, implemented in 1/2024, flags ureteral stents at risk for retention based on implant documentation, expected explant date, and explant documentation. Monthly reports are generated for stents missing explant documentation. We retrospectively evaluated the diagnostic performance of eSTENT from 1/2024-8/2025 at our pediatric hospital. A usability survey including a validated 1-7 implementation score (higher = easier implementation) was distributed to pediatric urologists and operating room nurses. RESULTS: Of 172 cases with ureteral stent placement, eSTENT flagged 28 events (16%) in 24 patients. Of these, 26 represented documentation gaps where explant had been appropriate. Two flags had no documentation of explant, representing near miss events that were identified. No retained stents occurred, consistent with high sensitivity and modest specificity. There were no flags in the last 6 months of the study period. Survey response rate was 100% for surgeons and 55% for nurses. Before eSTENT, stents were not routinely tracked. All surgeons and 93% of nurses reported no added burden, despite occasional misidentification of retained stents. Three surgeons found eSTENT beneficial, four were neutral, and free-text responses generally cited eSTENT's "fail safe" nature as positive. Nurses suggested improvements, including user support and integrated documentation reminders. The average implementation score among both groups was 6/7, indicating easy adoption. DISCUSSION: While the impact of stent tracking tools in adult literature has been positive, our study emphasizes the feasibility of broader adoption at a pediatric hospital. Integration of eSTENT may avoid the potentially devastating consequences of a retained stent. Prioritizing sensitivity over specificity appears acceptable for a "never event" in patient safety. Our study is limited by the retrospective nature of data collection and survey bias. CONCLUSIONS: Though no stents were retained in the study period, eSTENT appropriately flagged two cases without added burden to most end-users. Further optimization is warranted, but adoption in pediatric centers may enhance care reliability.

Explore related subjects

Keep this discovery

BibTeXRIS

Caleb Q Ashbrook, Ryan Hsi, Kerri L Cavanaugh, Douglass B Clayton, Brendan T Frainey, Allison B McCoy, David F Penson, Vijay Rings, Seth M Smith, Adam Wright, Lauren E Corona. 2026-06-17. Feasibility of implementation, diagnostic accuracy, and end-user impact of an electronic health record (EHR)-based ureteral stent tracking tool in a pediatric population.. https://doi.org/10.1016/j.jpurol.2026.106094

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Advanced/Novel Stenting for Pediatric Dynamic Airway Collapse.

Pediatric dynamic airway collapse is a complex condition that can impact all levels of the pediatric airway. These conditions can pose life threatening risk to pediatric patients and carry lasting impacts. While traditionally, tracheostomy has been used to address all levels of dynamic collapse, recent advances have allowed for more individualized, anatomy-specific stenting and splinting strategies for treatment. This article covers pathophysiology and the latest evidence on strategies to address nasopharyngeal, oropharyngeal, proximal trachea, and tracheobronchial dynamic collapse.

Humans

A stent-plus-irrigation protocol after adolescent hypospadias repair: a multicentre randomised controlled trial.

OBJECTIVES: To evaluate whether a stent-plus-irrigation protocol reduces complication rates following hypospadias repair in adolescents compared with catheter drainage alone. PATIENTS AND METHODS: In this multicentre randomised controlled trial, adolescents (Tanner Stage II-V) undergoing hypospadias repair were randomly assigned to either a stent-plus-irrigation group or a catheter-drainage group. The catheter-drainage group received standard urethral catheter drainage alone, whereas the stent-plus-irrigation group received an additional small-calibre urethral stent positioned within the reconstructed urethra and twice-daily saline irrigation. The primary outcome was the overall postoperative complication rate; secondary outcomes included urinary function and cosmetic outcomes. RESULTS: A total of 172 adolescents were assessed for eligibility, with 150 participants (75 in the stent-plus-irrigation group and 75 in the catheter-drainage group) included in the final analysis. Compared with the catheter-drainage group, the stent-plus-irrigation group demonstrated a significantly lower overall complication rate (risk ratio [RR] 0.33, 95% confidence interval [CI] 0.20-0.56; P&#x2009;<&#x2009;0.001), urethral fistula rate (RR 0.27, 95% CI 0.14-0.51; P&#x2009;<&#x2009;0.001), and surgical site infection (SSI) rate (RR 0.43, 95% CI 0.21-0.87; P&#x2009;=&#x2009;0.020). CONCLUSIONS: A postoperative stent-plus-irrigation protocol was associated with lower rates of postoperative complications, particularly urethral fistula and SSI, compared with catheter drainage alone after adolescent hypospadias repair. Because the intervention included both an additional urethral stent and saline irrigation, the independent contribution of irrigation cannot be determined in this two-arm trial.

Humans