Search PubMedSearch

PubMed · 41925047

Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.

Abstract

INTRODUCTION: Pancreatic fluid collections (PFCs), particularly walled-off necrosis, are common complications of acute pancreatitis that often require endoscopic drainage. Bi-flanged metal stents (BFMS; NAGI; Taewoong Medical, Gyenoggi-do, Korea) and electrocautery-enhanced lumen-apposing metal stents (LAMS; AXIOS, Boston Scientific Corporation, Marlborough, Massachusetts, USA) are frequently used, but comparative data remain limited. This study aims to compare the efficacy and safety of BFMS and LAMS in the endoscopic drainage of PFCs. METHODS: This meta-analysis followed the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Comprehensive database searches were conducted through November 2024 to identify studies comparing BFMS and LAMS for endoscopic ultrasound-guided drainage of PFCs. Outcomes were pooled using a random-effects model with RevMan Web, and statistical significance was defined as a P value less than 0.05. RESULTS: Three studies ( n  = 627; 329 BFMS and 298 LAMS) met inclusion criteria. No significant differences were observed between BFMS and LAMS for technical success [odds ratio (OR): 1.16; 95% confidence interval (CI): 0.55-2.43] or clinical success (OR: 0.97; 95% CI: 0.51-1.87). Similarly, there were no differences in walled-off necrosis recurrence (OR: 2.01; 95% CI: 0.17-24.02), number of direct endoscopic necrosectomy sessions (OR: 0.52; 95% CI: 0.05-5.12), or mean number of endoscopic procedures (mean difference: 0.18, 95% CI: 2.08-2.45). Adverse events were also comparable between groups, including bleeding (OR: 0.64), infection (OR: 1.18), stent migration (OR: 1.83), and stent occlusion/dysfunction (OR: 1.71). CONCLUSION: BFMS and LAMS provide equivalent efficacy and safety in the endoscopic ultrasound-guided drainage of PFCs. Either stent type represents a viable therapeutic option. Further large-scale prospective studies are warranted to refine stent selection strategies.

Explore related subjects

Keep this discovery

BibTeXRIS

Muhammad Shahzil, Muhammad Hashim Faisal, Muhammad Hammad Khan, Syeda Fatima Abid, Minahel Shehzadi, Muhammad Saad Faisal, Ammad Javaid Chaudhary, Muhammad Sheharyar Warraich, Jennifer L Maranki. 2026-03-27. Comparative efficacy and safety of bi-flanged metal stents versus lumen-apposing metal stents for endoscopic drainage of pancreatic fluid collections: a systematic review and meta-analysis.. https://doi.org/10.1097/meg.0000000000003190

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

A stent-plus-irrigation protocol after adolescent hypospadias repair: a multicentre randomised controlled trial.

OBJECTIVES: To evaluate whether a stent-plus-irrigation protocol reduces complication rates following hypospadias repair in adolescents compared with catheter drainage alone. PATIENTS AND METHODS: In this multicentre randomised controlled trial, adolescents (Tanner Stage II-V) undergoing hypospadias repair were randomly assigned to either a stent-plus-irrigation group or a catheter-drainage group. The catheter-drainage group received standard urethral catheter drainage alone, whereas the stent-plus-irrigation group received an additional small-calibre urethral stent positioned within the reconstructed urethra and twice-daily saline irrigation. The primary outcome was the overall postoperative complication rate; secondary outcomes included urinary function and cosmetic outcomes. RESULTS: A total of 172 adolescents were assessed for eligibility, with 150 participants (75 in the stent-plus-irrigation group and 75 in the catheter-drainage group) included in the final analysis. Compared with the catheter-drainage group, the stent-plus-irrigation group demonstrated a significantly lower overall complication rate (risk ratio [RR] 0.33, 95% confidence interval [CI] 0.20-0.56; P&#x2009;<&#x2009;0.001), urethral fistula rate (RR 0.27, 95% CI 0.14-0.51; P&#x2009;<&#x2009;0.001), and surgical site infection (SSI) rate (RR 0.43, 95% CI 0.21-0.87; P&#x2009;=&#x2009;0.020). CONCLUSIONS: A postoperative stent-plus-irrigation protocol was associated with lower rates of postoperative complications, particularly urethral fistula and SSI, compared with catheter drainage alone after adolescent hypospadias repair. Because the intervention included both an additional urethral stent and saline irrigation, the independent contribution of irrigation cannot be determined in this two-arm trial.

Humans

Efficacy and safety of endoscopic ultrasound-guided choledochoduodenostomy compared with endoscopic ultrasound-guided gallbladder drainage for palliation of malignant distal biliary obstruction: a systematic review and meta-analysis.

BACKGROUND AND AIMS: When ERCP is not feasible or fails in the palliation of malignant distal biliary obstruction (MDBO), EUS-guided choledochoduodenostomy (EUS-CDS) and EUS-guided gallbladder drainage (EUS-GBD) are viable alternatives. We conducted a systematic review and meta-analysis comparing the safety and efficacy of the 2 techniques for the palliation of MDBO. METHODS: Multiple databases were searched through November 2025 for studies that reported outcomes of EUS-CDS and EUS-GDB in patients with MDBO. A meta-analysis was performed to determine pooled proportions and relative risk (RR) with 95% CIs. We compared the rates of technical and clinical success, overall adverse events (AEs), and lumen-apposing metal stent dysfunction. A random-effects model was used for our meta-analysis, and heterogeneity was assessed using the I2 (%) statistics. RESULTS: Five studies (352 patients; EUS-CDS: 193 and EUS-GBD: 159) were included. Technical success was 93.3% (95% CI, 70.6-98.8) for EUS-CDS and 95.9% (95% CI, 90.0-98.4) for EUS-GBD (RR, 1.02; 95% CI, 0.94-1.10; P = .6). Clinical success was 90.1% (95% CI, 84.7-93.7) versus 86.6% (95% CI, 80.3-91.0) (RR, 0.97; 95% CI, 0.90-1.05; P = .4). There were no significant differences in overall AEs (19.7% vs 17.6%; RR, 0.93; 95% CI, 0.58-1.48; P = .8), severe AEs (11.0% vs 8.3%; RR, 0.69; 95% CI, 0.33-1.44; P = .3), or stent dysfunction (15.0% vs 14.5%; RR, 0.95; 95% CI, 0.35-2.58; P = .9). CONCLUSIONS: EUS-GBD appears comparable to EUS-CDS in terms of technical and clinical success, AEs, and stent dysfunction. Further prospective studies are warranted to corroborate our findings.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans