Search PubMedSearch

SEARCH · Search PubMed

Results for “Wearable sensors”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 recordsLinked to original sources

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n = 10, 62.5%), language (n = 2, 12.5%), gait (n = 2, 12.5%), caregiver proximity (n = 1, 6.3%), EEG power (n = 1, 6.3%), and arousal (n = 1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps, and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC = 0.91-0.92 [0.83-0.97]; k = 55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC = 0.90-0.91 [0.85-0.95] (k = 228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs = 0.90 [0.83-0.94] (k = 124) and ICC = 0.91 [0.72-0.98] (k = 9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load–velocity relationship

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‑Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta‑Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I² statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R²=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

The application of artificial intelligence in healthcare practice: A mapping review of systematic reviews.

Artificial intelligence (AI) is rapidly transforming healthcare practice, with growing evidence supporting its use in diagnosis, prognosis, treatment planning, and operational decision-making. The proliferation of systematic reviews in recent years underscores the need for an updated synthesis of the literature to inform research, policy, and practice. We searched PubMed, Web of Science, Scopus, IEEE Xplore, and CINAHL for systematic reviews and meta-analyses published between 2019 and February 2026. Eligible reviews focused on AI applications in healthcare practice, were peer-reviewed, and written in English. A total of 368 reviews met the inclusion criteria. Publication volume increased steadily, peaking in 2025. AI research was concentrated in high-density domains, such as radiology, oncology, and critical care. Across reviews, diagnostic imaging, electronic health record (EHR) data, and biomarkers/laboratory results accounted for 68% of training data sources, though newer data types, such as wearable device and sensor data, emerged from 2022 onward. Diagnosis, prognosis, and treatment comprised over 80% of AI applications, with novel uses emerging in recent years, such as AI-assisted clinical documentation (e.g., ambient documentation tools) and patient education. Ethical concerns were reported in 78.5% of reviews, with privacy, model accuracy, data and algorithmic bias, and explainability as recurrent themes. The proportion of reviews reporting ethical concerns increased from 2021 to 2025. AI applications in healthcare are expanding in scope, diversifying in data sources, and evolving toward novel clinical and operational uses. The human-centered AI or augmented intelligence paradigm, integrating computational precision with clinical expertise, holds significant promise but will require parallel advances in governance, regulatory frameworks, and ethical oversight to ensure safe adoption.

Artificial Intelligence

A smartphone-integrated Pt@Cu-HCF nanozyme-based paper sensor for on-site determination of total antioxidant capacity in marine oils.

Total antioxidant capacity (TAC) serves as a key indicator for evaluating the nutritional quality of foods. In this study, we designed a platinum-embedded copper hexacyanoferrate (denoted as Pt@Cu-HCF) nanozyme that exhibits high oxidase-like activity, efficiently catalyzing the oxidation of chromogenic substrates to generate robust colorimetric signals. Antioxidants quench hydroxyl radicals (∙OH) produced during the catalytic process, leading to a concentration-dependent suppression of the color signal. Leveraging this mechanism, a smartphone-integrated, colorimetric paper sensor for on-site TAC quantification was developed, using vitamin E as the calibration standard. The sensor was applied to determine TAC in fish oil, algal oil, and krill oil, demonstrating a linear response range of 9.78-312.5 μM and a limit of detection (LOD) of 6.41 μM. Validation using real-world marine oil samples showed excellent agreement with a commercial assay kit, confirming the reliability and practical applicability of this portable sensor for TAC measurement in complex biological matrices.

Antioxidants

Machine learning-assisted Mn-N-C nanozyme colorimetric sensor array for trace-level detection of biogenic amines in meat.

Accurate detection of biogenic amines (BAs) in meat remains challenging due to their high structural similarity and co-occurrence. Herein, an Mn-N-C nanozyme was synthesized via a metal-organic framework confined pyrolysis strategy, possessing excellent oxidase (OXD)- and peroxidase (POD)-like activities. The dual enzyme-like activity showed Km values of 0.1584 mM (OXD) and 0.1498 mM (POD), respectively, in detection system. Leveraging these properties, a colorimetric sensor array was constructed, enabling the detection of four representative BAs within a concentration range of 2-10 ppm with 100% classification accuracy. In addition, a concentration independent recognition model based on an artificial neural network was developed to address signal nonlinearity interference in meat. The integrated system achieved accurate trace-level identification of BAs in perishable fish, pork, and chicken, demonstrating its applicability for early-stage BAs monitoring and quality deterioration warning during storage and transportation.

Biogenic Amines

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10 min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as ≥1 h on ≥2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24°C and time spent above 25°C were used. Agreement between the measures was summarised by percentage agreement and kappa (ĸ). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24°C and 25°C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, ĸ=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77 fg/μL to 1 ng/μL, with an LOD of 2.02 fg/μL and an LOQ of 3.77 fg/μL. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P > 0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

A MIL-88@Ru-based molecularly imprinted electrochemiluminescence sensor for highly selective and sensitive detection of enrofloxacin residues in animal-derived foods.

Using a metal-organic framework (MOF) - supported Ru(bpy)32+ (MIL-88@Ru) composite luminescent material, this study innovatively adopted electropolymerization to fabricate a molecularly imprinted polymer-based electrochemiluminescent (MIP-ECL) sensor for enrofloxacin (ENR) detection in animal-derived foods. Systematic investigation of the ECL luminescence and ENR's quenching mechanism confirmed that the sensor integrates ECL's high sensitivity and MIP's high specificity, enabling rapid and accurate recognition of ENR. Experimental results show a good linear response in the range of 1 nmol/L-20 μmol/L (R2 = 0.99), a limit of detection (LOD) as low as 0.28 nmol/L, as well as excellent selectivity and stability. Recoveries of ENR in all investigated matrices ranged from 97.7% to 106.4%, confirming the reliability of the established method. This ECL-MIP coupling strategy provides a new technical approach and application references for the efficient detection of trace pollutants in food safety and environmental monitoring fields.

Enrofloxacin

PdIr bimetallic nanozyme engineered metal-organic frameworks integrated dual-mode sensor toward Stx2 detection in food.

Shiga toxin II (Stx2) has attracted extensive attention due to its toxicity and pathogenicity, making the development of sensitive detection methods urgent. This study constructed a dual-mode sensing platform for the sensitive detection of Stx2 in food. Composite material UIO-66@PdIr with peroxidase-like activity and fluorescent properties was synthesized and combined with cDNA as the signal probe, while aptamer-modified magnetic beads served as the capture probe. Specific binding of Stx2 to the aptamer triggered the release of the signal probe, enabling colorimetric and fluorescence signal readout. The colorimetric mode showed a linear range of 0.05-100 ng/mL with an LOD of 0.039 ng/mL, and the fluorescence mode exhibited 0.01-1000 ng/mL with an LOD of 0.0097 ng/mL. Additionally, this method was successfully applied to the detection of Stx2 in food, and the recovery rates were 94.33% ∼ 102.20%. It indicated that the constructed sensor holds great practical potential for Stx2 detection.

Food Contamination

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7 × 108 CFU/mL and a low detection limit of 1.66 CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19% ∼ 104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54 nM (S/N = 3) within a linear range of 0.2-12 μM. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14&#xa0;&#x3bc;M and a low detection limit of 4.3&#xa0;nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

Morphology-Encoded Colorimetric Hydrogen Sensing Using Embedded Reactive Pd Absorbers in Fabry-Perot Cavities.

Chemical reactions offer a powerful strategy for generating visible optical responses through localized changes in absorption, dielectric environment, and interfacial wetting. A palladium (Pd)-embedded Fabry-Perot cavity is introduced as a reaction-active optical platform in which structural color is governed by intracavity absorption coupled with reaction-induced dielectric perturbation. Positioning Pd within the dielectric spacer creates a spatially controllable reactive absorber whose vertical location relative to the standing-wave field dictates wavelength-selective absorption within the cavity. The morphology of the embedded Pd layer provides an additional design parameter by modulating both optical loss and interfacial wetting. Under hydrogen exposure in the presence of oxygen, catalytic water formation at the Pd/polymer interface generates localized dielectric heterogeneity and interfacial water droplets, thereby perturbing the optical path length and amplifying the visible response. As a result, the cavity exhibits pronounced, morphology-dependent color transitions that are inaccessible through dielectric-layer engineering or Pd/PdH refractive-index changes alone, enabling direct visual hydrogen sensing under ambient light, as well as flexible optical devices capable of large-area patterning. These findings establish a design framework for reaction-active optical cavities that translate localized chemistry into a colorimetric hydrogen sensing mechanism.

Fabry&#x2013;Perot resonator