Search PubMedSearch

SEARCH · Search PubMed

Results for “PCD-CT”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

61 recordsLinked to original sources

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Digital health interventions for diabetes management in the eastern mediterranean region: A systematic review of types and effectiveness.

AIM: The aim of this study was to systematically review and evaluate the types and effectiveness of digital health interventions used for diabetes management in the Eastern Mediterranean Region (EMRO). METHODS: This systematic review, conducted according to PRISMA guidelines, searched PubMed, Web of Science, and Scopus up to May 2025 to identify studies on digital interventions for diabetes management in EMRO countries. Methodological&#xa0;quality of the included studies was evaluated using the EPHPP tool, and findings were categorized by intervention type, outcome measures, and intervention effectiveness. RESULTS: A total of 46 studies were included, mainly from Iran and Saudi Arabia. Phone calls and SMS were the most common digital tools. Digital interventions significantly improved HbA1c, fasting blood sugar, and several behavioral outcomes such as physical activity, medication adherence, and self-efficacy, while effects on psychological outcomes were mixed. CONCLUSION: Digital health interventions, especially phone calls and SMS, effectively improve glycemic control and self-care behaviors, though their impact on psychological outcomes remains inconsistent.

Humans

The effectiveness of digital health interventions for type 2 diabetes in underserved populations: A systematic review and meta-analysis.

This systematic review and meta-analysis of 12 randomized controlled trials (1835 participants) evaluated whether digital health interventions (DHIs) improve glycemic control among underserved adults with type 2 diabetes (T2D), including racial/ethnic minority, low-income, Medicaid-insured, rural, and low-health-literacy populations. Searches of PubMed, Embase, and the Cochrane Central Register of Controlled Trials from inception to December 20, 2025 identified eligible parallel-group randomized controlled trials reporting change in hemoglobin A1c (HbA1c). Two reviewers independently screened studies, extracted data, and assessed risk of bias using the revised Cochrane Risk of Bias 2 tool. Random-effects meta-analysis showed that DHIs produced a modest but statistically significant HbA1c reduction versus control (mean difference, -0.37 %age points; 95% CI, -0.44 to -0.30; P&#x202f;<&#x202f;.0001; equivalent to -4.0&#x202f;mmol/mol). Heterogeneity was moderate-to-substantial (I&#xb2; = 69.9%). Subgroup analyses suggested directionally similar effects by population group and intervention modality, but interpretation was limited by study-level data and the small number of trials. Funnel-plot inspection and Egger's test (P&#x202f;=&#x202f;.31) did not suggest major small-study effects, although power was limited. Overall certainty for HbA1c was moderate. DHIs may support more equitable diabetes care when implemented with cultural tailoring, language access, digital-literacy support, and technology-access safeguards.

Humans

Effect of SGLT2 inhibitor drugs on triglyceride-glucose (TyG) index in adults: A systematic review and meta-analysis.

BACKGROUND: Insulin resistance is a serious public health concern. The triglyceride-glucose (TyG) index is a simple, cheap, and reproducible surrogate of insulin resistance, and sodium-glucose cotransporter-2 (SGLT2) inhibitors have reshaped cardio-metabolic care beyond glycemic control. METHODS: We followed PRISMA and registered the protocol in PROSPERO (CRD420251056341). We searched PubMed, Scopus, Web of Science, EMBASE, and Cochrane from inception to May 31st, 2026, including observational studies and clinical trials reporting baseline and follow-up TyG in adults. Two reviewers screened records, a third resolved disagreements, data were extracted with a standardized form, and quality was assessed with Cochrane RoB 2.0, the Newcastle-Ottawa Scale, and the JBI checklists. The primary outcome was within-group change in TyG pooled with random-effects (Hartung-Knapp); tests were two-sided with a significance threshold of 0.05. RESULTS: Twelve studies comprising thirteen study arms were included, with a total of 1845 participants. Follow-up ranged from 12 weeks to 5 years. Across studies, SGLT2 inhibitor therapy was associated with a significant reduction in TyG index (mean difference = -0.28, 95% confidence interval [-0.41; -0.14], I2 = 99.5%). Egger's test suggested possible small-study effects, whereas Begg's test and trim-and-fill analysis did not show clear evidence of publication bias; leave-one-out analyses showed that no single study materially influenced the pooled estimate. CONCLUSION: Despite heterogeneity in populations, drug choice, and follow-up duration, SGLT2 inhibitors were associated with a significant decrease in TyG, although small-study effects cannot be excluded.

Humans

Mobile health apps improve Health-Related Quality of Life in Type 2 Diabetes Mellitus by enhancing medication adherence: A multicentre randomised controlled trial with mediation analysis.

AIMS: This study evaluated whether a gamified mHealth application (CareAide&#xae;) improves Health-Related Quality of Life (HRQoL) in Type 2 Diabetes Mellitus (T2DM) and whether this effect is mediated by medication adherence. METHODS: Prespecified secondary analysis of the T2DM cohort from a 6-month multicentre RCT (NCT06068309; N&#x202f;=&#x202f;663; three Malaysian hospitals). Participants were randomised 1:1 to standard care or CareAide&#xae;. Adherence (MMAS-8), EQ-5D-5L utility (Malaysian value set), and AQoL-6D were assessed at baseline and 6 months. Simple mediation analysis (PROCESS Model 4; 5000 bootstraps) adjusted for baseline HRQoL. RESULTS: CareAide&#xae; significantly predicted higher MMAS-8 scores (mean difference +1.756; d = 1.638; p&#x202f;<&#x202f;0.001). Higher MMAS-8 scores significantly predicted improved AQoL-6D utility (b = 0.024; p&#x202f;<&#x202f;0.001). The direct effect on AQoL-6D was non-significant (p&#x202f;=&#x202f;0.248). Bootstrapped indirect effect confirmed full mediation via AQoL-6D (0.042; 95% CI [0.024, 0.060]). A sensitivity analysis adjusting for baseline HbA1c confirmed full mediation (indirect = 0.034; 95% CI [0.015, 0.052]; n&#x202f;=&#x202f;563). EQ-5D-5L utility showed a significant direct between-group difference at 6 months (p&#x202f;=&#x202f;0.012) but did not operate as a mediation outcome. CONCLUSIONS: Medication adherence fully mediates the AQoL-6D HRQoL benefit of a gamified mHealth intervention in T2DM, as confirmed by both the primary and HbA1c-adjusted sensitivity analyses. These findings support integration of behaviourally informed digital adjuncts into routine primary diabetes care.

Humans

Dietary approaches for glycemic management in type 1 diabetes: A systematic review of Mediterranean and low-carbohydrate diets.

BACKGROUND/OBJECTIVES: Specific dietary approaches for better management of type 1 diabetes (T1D) have not been thoroughly investigated. We conducted a systematic review to evaluate the Mediterranean and low-carbohydrate diets for glycemic management in people with T1D. METHODS: We examined longitudinal studies (cohort studies and clinical trials) including individuals with T1D who followed low-carbohydrate diets (<26% calories from carbohydrates and/or <130&#x202f;g of carbohydrates per day) and/or a Mediterranean diet, while hemoglobin A1c (HbA1c) and/or time in range (TIR) were measured. Additional eligibility criteria included publication in English and availability of a full-text primary research article. Non-longitudinal studies, abstracts, and studies published in languages other than English were excluded. Results were synthesized narratively, and the GRADEpro Guideline Development Tool was used to assess article quality. RESULTS: A total of 565 studies were identified from PubMed, the Web of Science, and citation chasing. After removal of duplicates and further evaluation, 22 studies (6 cohort studies and 16 clinical trials; total n&#x202f;=&#x202f;3284) were included in this review. The search was initially completed in May 2024, and updated February 2026. Low-carbohydrate diets were associated with better glycemic management when compared to usual diets or baseline glycemic parameters. Studies using CGM were overall underpowered. The impact of Mediterranean diets was less clear, but generally appeared to be less effective at improving glycemic management than low-carbohydrate diets. DISCUSSION: Although structured dietary interventions for T1D hold promise for improving glycemic outcomes, further research is needed to determine exactly which dietary intervention is most beneficial for this population. The evidence provided by included studies is limited by small sample sizes and short durations; better powered, longer-term studies are required to inform clinical recommendations.

Humans

Disparities in guideline-adherent cardiovascular preventive care for people with diabetes: A systematic review and meta-analysis.

BACKGROUND: Clinical practice guidelines offer guidance on delaying the progression of cardiovascular disease in people living with diabetes. We sought to determine whether guideline-recommended cardiovascular preventive care for people living with diabetes differs according to sociodemographic indicators, globally. METHODS: We conducted a systematic review of studies that compared the sociodemographic characteristics of people diagnosed with type 1 or 2 diabetes who received cardiovascular preventive care as recommended by guidelines to those who did not. Sociodemographic predictors were defined by PROGRESS+ (an equity framework). We searched MEDLINE, EMBASE, and APA PsychInfo from 2010 to January 21, 2026. Studies were screened independently by two people. One person assessed the risk of bias and extracted data, and another verified. We pooled results using a random-effects model and assessed the certainty of evidence using GRADE. RESULTS: Twenty-five studies were included. Meta-analyses showed female, Black, and Hispanic individuals had slightly lower odds of receiving guideline-recommended prescriptions for lipid-lowering medication compared to Male, and White individuals, respectively (OR:0.89, 95%CI:0.79,1.00, moderate certainty; OR:0.78, 95%CI:0.74,0.81, high certainty; OR:0.86, 95%CI:0.59,1.26, low certainty). Individuals aged 18-45 years had moderately lower odds (OR:0.33, 95%CI:0.19,0.57, moderate certainty), no observed association for Asian individuals. Asian individuals had moderately lower odds of antihypertensive medication prescription (OR:0.42, 95%CI:0.38,0.46, high certainty). Evidence suggests likely no association between HbA1c testing and sex/gender or between sex/gender and lipid panel testing. CONCLUSIONS: Some disparities in guideline-recommended cardiovascular preventive care among people living with diabetes were found. These results are consistent with previous reviews and highlight the need to ensure guidelines consider equity and with improved dissemination.

Humans

A reanalysis of the Hitachi cohort study evaluating the effectiveness of low-dose CT screening for lung cancer.

The effectiveness of low-dose thoracic computed tomography (CT) screening for lung cancer for non-smokers or light smokers has been unclear. The results of the Hitachi cohort study performed by the conventional multivariable analysis suggested the reduction of lung cancer mortality by thoracic CT screening, but also revealed the lower all-cause mortality in the CT group, which indicated the existence of self-selection bias. Because the background of the subjects in the CT screening group and that in the X-ray screening group were very different, it is critical to adjust appropriately the confounding factors. In this brief report, we describe a re-evaluation of the results of the Hitachi Cohort Study performed by using more flexible methods, propensity score matching and inverse probability weighting.

epidemiology/public health

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19&#x2009;433 patients (mean age, 62 years &#xb1; 14.2 [SD]; 21&#x2009;814 men; 39&#x2009;323 chest CT examinations, 19&#x2009;190 pre-AI, and 20&#x2009;133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20&#x2009;000-22&#x2009;000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. &#xa9; The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.

Humans

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

CT-Derived pelvic morphometry for preoperative risk assessment of recurrent unilateral inguinal hernia.

BACKGROUND: Recurrent inguinal hernia remains a significant challenge in abdominal wall surgery despite advances in mesh-based repair techniques and minimally invasive approaches. Although pelvic skeletal morphology has been implicated in inguinal hernia development, its association with recurrent disease remains incompletely understood. This study aimed to evaluate computed tomography (CT)-derived pelvic morphometric parameters and investigate their potential value in preoperative recurrence risk assessment. METHODS: This retrospective study included 251 male patients with preoperative abdominal CT examinations and complete clinical records who underwent elective inguinal hernia repair at a tertiary referral center. After applying the predefined eligibility criteria, 188 patients with unilateral inguinal hernias constituted the primary study cohort, including 162 primary and 26 recurrent unilateral hernias. The Radoievitch angle and Ami's line were measured independently by two blinded radiology residents using a standardized CT-based pelvic morphometric measurement protocol, and the mean values were used for analysis. Multivariable logistic regression and receiver operating characteristic (ROC) curve analyses were performed to evaluate the association between pelvic morphometric parameters and recurrent inguinal hernia. RESULTS: Patients with recurrent unilateral inguinal hernias demonstrated significantly greater affected-side Ami's line measurements (8.27&#x2009;&#xb1;&#x2009;0.63 vs. 7.90&#x2009;&#xb1;&#x2009;0.71&#xa0;cm, p&#x2009;=&#x2009;0.014) and larger Radoievitch angles (40.68&#x2009;&#xb1;&#x2009;4.02&#xb0; vs. 38.80&#x2009;&#xb1;&#x2009;3.68&#xb0;, p&#x2009;=&#x2009;0.018) than patients with primary unilateral hernias. Both the Radoievitch angle (OR 1.14, 95% CI 1.01-1.28, p&#x2009;=&#x2009;0.033) and Ami's line (OR 2.26, 95% CI 1.14-4.49, p&#x2009;=&#x2009;0.020) remained independently associated with recurrent inguinal hernia after adjustment for age and body mass index. ROC analysis demonstrated modest discriminatory performance (AUC 0.634 for the Radoievitch angle and 0.633 for Ami's line), while the multivariable model incorporating age, body mass index, and Ami's line showed slightly improved discrimination (AUC 0.655). CONCLUSION: CT-derived pelvic morphometric parameters were independently associated with recurrent unilateral inguinal hernia. Although their individual discriminatory performance was modest, standardized CT-based pelvimetry may serve as an objective adjunctive tool for individualized preoperative recurrence risk assessment in patients who already undergo CT imaging for unrelated clinical indications. Prospective multicenter studies are warranted to validate these findings and determine their clinical applicability.

Humans

The role of artificial intelligence in the diagnosis and prognosis of traumatic brain injury based on brain CT scans: a systematic review.

Traumatic brain injury (TBI) is a leading cause of emergency department visits and a major contributor to injury-related mortality and long-term neurological disability. Non-contrast computed tomography (CT) is the gold-standard imaging modality for the rapid diagnosis of TBI. Clinical outcomes depend strongly on early detection and prompt acute management. Artificial intelligence (AI)-based models may support faster automated identification of traumatic findings and early prediction of patient prognosis.&#xa0;A systematic literature search was conducted in PubMed/MEDLINE, Scopus, IEEE Xplore, ACM Digital Library, and the Cochrane Library in accordance with PRISMA 2020 guidelines to evaluate AI-based models for automated detection of TBI-related findings on CT and for prediction of clinical outcomes. Risk of bias and applicability were assessed using QUADAS-2 for diagnostic accuracy studies and PROBAST&#x2009;+&#x2009;AI for prediction model studies.&#xa0;Twenty-two studies were included. Sixteen studies evaluated diagnostic tasks and 10 evaluated prognostic outcomes, with four studies contributing to both categories. Diagnostic performance was generally high, with many studies reporting AUC values approaching or exceeding 0.90, particularly for larger lesion volumes.Prognostic performance was more variable, with moderate to high discrimination and substantial heterogeneity. Only 9 studies incorporated independent external validation, and performance was frequently lower in external cohorts. All prognostic model studies were judged to be at high overall risk of bias using PROBAST&#x2009;+&#x2009;AI, and most diagnostic accuracy studies also demonstrated high or unclear risk of bias in at least one QUADAS-2 domain, most frequently in patient selection.&#xa0;AI-based models applied to brain CT demonstrate strong technical performance for both diagnostic and prognostic tasks in TBI. However, most studies relied on retrospective designs and lacked independent external validation which limits models generalizability and raises concern for potential overfitting. Prospective, multicenter studies with standardized methodologies and rigorous external validation are required before widespread clinical implementation.

Humans

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans