Search PubMedSearch

SEARCH · Search PubMed

Results for “Blood pressure targets”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

633 recordsLinked to original sources

Higher versus Routine Intraoperative Blood Pressure Targets in Noncardiac Surgery: A Systematic Review and Meta-analysis with Trial Sequential Analysis of Randomized Trials.

BACKGROUND: Observational studies consistently link intraoperative hypotension to adverse postoperative outcomes, leading guidelines to recommend maintaining mean arterial pressure 60 to 65 mmHg or greater during noncardiac surgery. Whether targeting higher intraoperative blood pressure values improves clinical outcomes remains uncertain. METHODS: The authors conducted a Preferred Reporting Items for Systematic Reviews and Meta-analyses-guided search on PubMed, Cochrane Central Register of Controlled Trials, Scopus, and Embase from inception to April 2026. Randomized trials comparing higher intraoperative blood pressure targets, either as fixed absolute thresholds or personalized to preoperative baseline, versus routine blood pressure management in adults undergoing elective noncardiac surgery with general anesthesia were included. Outcomes included in-hospital or 30-day mortality, postoperative delirium, acute kidney injury (AKI), 30-day major cardiovascular events, acute myocardial injury, stroke, length of stay, and intraoperative hypotension. RESULTS: Fifteen trials (15,603 patients) were included. Higher targets did not reduce AKI (risk ratio [RR], 0.95; 95% CI, 0.85 to 1.06; P = 0.36; I 2 = 16%) or acute myocardial injury (RR, 1.02; 95% CI, 0.94 to 1.12; P = 0.59; I 2 = 0%) compared with routine targets, with firm evidence from trial sequential analysis. Higher targets were associated with a significant reduction in postoperative delirium (RR, 0.73; 95% CI, 0.54 to 0.98; P = 0.04; I 2 = 26%), although trial sequential analysis indicated the cumulative evidence remained insufficient to draw firm conclusions. No significant effect was observed on in-hospital or 30-day mortality (RR, 1.00; 95% CI, 0.75 to 1.34; P = 1.00; I 2 = 0%); evidence on 30-day major cardiovascular events, stroke, and length of stay was similarly insufficient to draw firm conclusions. CONCLUSION: In adults undergoing elective noncardiac surgery, targeting higher intraoperative blood pressure values does not improve major postoperative outcomes compared with routine management. A potential reduction in postoperative delirium warrants confirmation in adequately powered trials.

Humans

Efficacy of CagriSema for Reaching Anthropometric Treatment Targets and Cardiometabolic Outcomes: A Secondary, Post hoc Analysis of REDEFINE 1.

AIMS: To assess the added value of absolute anthropometric targets alongside percentage weight loss in the clinical management of obesity. MATERIALS AND METHODS: The phase 3a, 68-week REDEFINE 1 trial randomised adults without diabetes with BMI &#x2265;&#x2009;30&#x2009;kg/m2, or&#x2009;&#x2265;&#x2009;27&#x2009;kg/m2 with &#x2265;&#x2009;1 obesity-related complication, to once-weekly CagriSema 2.4&#x2009;mg/2.4&#x2009;mg, semaglutide 2.4&#x2009;mg, cagrilintide 2.4&#x2009;mg, or placebo, plus lifestyle intervention. This secondary, post hoc analysis assessed the proportions of participants achieving BMI <&#x2009;27&#x2009;kg/m2 and/or WHtR <&#x2009;0.53 targets, and percentage weight loss by anthropometric target. The association between the proportion of participants maintaining or achieving normalisation of four cardiometabolic outcomes: normoglycemia (glycated haemoglobin <&#x2009;5.7% and fasting plasma glucose <&#x2009;5.6&#x2009;mmol/L); blood pressure (<&#x2009;130/80&#x2009;mmHg); triglycerides (<&#x2009;1.7&#x2009;mmol/L); lipids (high-density lipoprotein cholesterol &#x2265;&#x2009;1.3&#x2009;mmol/L [female] or &#x2265;&#x2009;1.0&#x2009;mmol/L [male]) and reaching anthropometric targets or change in body weight (%) was also assessed. RESULTS: The proportion of participants achieving both BMI <&#x2009;27&#x2009;kg/m2 and WHtR <&#x2009;0.53 targets at week 68 was 30.3%, 19.1%, 9.0%, and 3.3% in participants who received CagriSema, semaglutide, cagrilintide, or placebo respectively. Both BMI and WHtR performed similarly as indicators for all four cardiometabolic outcomes. At more stringent cut-off values, anthropometric targets were better measures than percentage weight loss. CONCLUSIONS: The proportion of participants achieving anthropometric targets was greater with CagriSema Versus other treatments. These findings support further validation of BMI and WHtR anthropometric treatment targets and indicate a potential for indicating amelioration of clinical outcomes in obesity and a greater emphasis on target-based treatment strategies.

Humans

Blood pressure management after endovascular thrombectomy in acute ischemic stroke: association with symptomatic intracranial hemorrhage and functional outcome at 3&#xa0;months.

BACKGROUND: No clear consensus exists on ideal systolic blood pressure (SBP) targets after endovascular thrombectomy (EVT) following an acute ischemic stroke (AIS). This study investigated the association between SBP parameters within the first 24&#xa0;h after EVT and 3-month functional outcomes and the risk of symptomatic intracranial hemorrhage (sICH). METHODS: We retrospectively collected and prospectively followed clinical, and radiological data for patients undergoing EVT for AIS from 2016 to 2024, including 2-hourly BP measurements during the first 24&#xa0;h and SBP variability assessed by standard deviation (SD) and coefficient of variation (CV). Outcomes included 3-month functional status and sICH, and their associations with post-EVT BP metrics were analyzed. RESULTS: A total of 268 post EVT patients were included with a median age of 61&#xa0;years (IQR, 51-69). Mean SBP was 129.67&#xa0;&#xb1;&#xa0;17.17&#xa0;mm Hg, with SBP variability (SD 12.6&#xa0;&#xb1;&#xa0;5.4&#xa0;mm Hg; CV 9.6&#xa0;&#xb1;&#xa0;3.8&#xa0;%), while good functional outcome and sICH occurred in 39.7&#xa0;% and 4.9&#xa0;% of patients, respectively. Multivariate regression showed that higher admission NIHSS&#xa0;(>15) [0.90 (95&#xa0;%CI, [0.86, 0.95], p&#xa0;=&#xa0;0.000)], recanalization status [1.88 (95&#xa0;%CI, [1.43, 2.48], p&#xa0;=&#xa0;0.00)], and SBP-CV&#xa0;&#x2265;&#xa0;10 [0.44 (95&#xa0;%CI, [0.2, 0.94], p&#xa0;=&#xa0;0.036)] was independently associated with poor 3-month functional outcome, while higher admission NIHSS (>15) [0.87 (95&#xa0;%CI, [0.77,0.98], p&#xa0;=&#xa0;0.02)] and diabetes [0.12 (95&#xa0;%CI, [0.03, 0.54], p&#xa0;=&#xa0;0.006)] predicted increased risk of sICH. CONCLUSIONS: The study showed that reduced BP variability during the first 24&#xa0;h post-EVT was associated with better 3-month functional outcomes. A clear association between SBP and sICH risk was not demonstrated.

Humans

Comparison of a Modified Regimen of Prophylactic Phenylephrine Boluses Versus Variable Rate Infusion During Elective Cesarean Delivery Under Spinal Anesthesia: A Noninferiority Randomized Double-Blind Study.

BACKGROUND: Prophylactic phenylephrine boluses have been found to be as effective as variable rate infusions during elective cesarean delivery but require a higher number of physician interventions to maintain blood pressure near baseline values. Therefore, there is a need to find a feasible regimen of bolus administration that is equally efficacious to the infusion regimen while at the same time requires a comparable number of physician interventions and is thus non-inferior to the infusion regimen. METHODS: Healthy pregnant women with term, uncomplicated, singleton pregnancies undergoing elective cesarean delivery under spinal anesthesia were randomly divided into two groups. The Bolus group received a phenylephrine bolus 100 &#x3bc;g immediately after spinal anesthesia and then at every systolic blood pressure value <90% of the baseline. The infusion group received a prophylactic variable-rate infusion of phenylephrine beginning at 50 &#x3bc;g/min and titrated to maintain systolic blood pressure at 90-99% of baseline. The primary outcome was the number of physician interventions needed to maintain the target systolic blood pressure; the secondary outcomes included phenylephrine requirements, incidence of hypotension/hypertension/bradycardia, umbilical arterial and venous blood gas analysis, Apgar scores, and maternal complications. The primary outcome was analyzed in terms of non-inferiority using a non-inferiority margin of two interventions. RESULTS: Eighty patients were included in the study. The median (interquartile range [IQR]) number of physician interventions was 6 (5-8) in the infusion group and 3 (2-4) in the bolus group (P < .001). The difference of medians (95% confidence interval [CI]) between the two groups was -3 (-4 to -2). Phenylephrine requirements were higher in the infusion group (630 [426-765] &#x3bc;g) compared to the bolus group (300 [200-400] &#x3bc;g; P < .001). Blood pressure was higher at certain time points in the infusion group, but overall accuracy of blood pressure control was not different between the groups. Incidence of hypotension, hypertension, and bradycardia, neonatal outcomes, and maternal complications did not differ between the groups. CONCLUSIONS: The modified regimen of prophylactic boluses is non-inferior to variable rate prophylactic phenylephrine infusion in terms of physician interventions needed to maintain systolic blood pressure within the target range and maternal and neonatal outcomes.

Humans

Closed-loop vasopressor systems for hemodynamic control in perioperative and critical care settings: a systematic review and meta-analysis.

Maintaining mean arterial pressure (MAP) within a predefined target is central to haemodynamic management in surgical and critically ill adults receiving vasopressors. Closed-loop vasopressor (CLV) systems automate titration to optimise blood pressure control, but their clinical effectiveness remains uncertain. We performed a systematic review and meta-analysis comparing CLV with manual titration. This PRISMA 2020-compliant review was prospectively registered in PROSPERO (CRD420250655697). MEDLINE, Embase, Scopus, Web of Science, CENTRAL, and the Cochrane Library were searched (January 2000-June 2025). Randomised controlled trials enrolling adults receiving vasopressors in perioperative or intensive care settings were included. Primary outcomes were time within the MAP target range and time spent in hypotension or hypertension. Risk of bias was assessed using RoB 2.0 and certainty of evidence using GRADE. Random- or fixed-effects models were selected according to heterogeneity. Six randomized controlled trials (215 patients) were included in the systematic review, whereas five perioperative trials contributed to the meta-analysis of haemodynamic control outcomes, and one ICU-based study was summarized narratively because it did not report comparable MAP control endpoints. CLV increased time within the MAP target range (mean difference [MD] 33.94%, 95% CI 20.41-47.46; I2&#x2009;=&#x2009;77%) and reduced time in hypotension (MD&#x2009;-&#x2009;18.24%, 95% CI&#x2009;-&#x2009;28.95 to&#x2009;-&#x2009;7.53; I2&#x2009;=&#x2009;73%). There was no significant difference in time in hypertension, cumulative norepinephrine dose, or major/minor adverse events. ICU length of stay was not pooled because of clinical and methodological heterogeneity. Certainty of evidence ranged from low to high (moderate for haemodynamic control outcomes). CLV systems improved haemodynamic control, primarily in perioperative settings,&#xa0;but heterogeneity and small samples limit confidence in effect size and generalisability.&#xa0;Evidence in critically ill populations remains limited, and larger trials are needed to determine whether improvements in these physiological surrogate endpoints translate into meaningful patient-centred outcomes.

Humans

Association between Kidney Tubular Secretory Clearance with Cognitive Function among Adults with CKD in the Systolic Blood Pressure Intervention Trial.

BACKGROUND: Persons with CKD are disproportionally affected with cognitive impairment, yet the pathophysiology linking the two conditions is unclear. Because kidney tubule secretion is essential for clearance of medications, uremic toxins, and metabolites, we hypothesized that worse tubular secretion would be associated with reduced cognitive function in CKD. METHODS: The Systolic Blood Pressure Intervention Trial tested a systolic blood pressure target <120 mmHg vs. <140 mmHg in hypertensive individuals at high cardiovascular risk. In paired blood and urine specimens from 1,937 participants with eGFR <60 ml/min/1.73m2, we measured 10 endogenous tubule-secreted metabolites and calculated a urine/plasma ratio for each, then averaged these to generate a summary secretion score. We used unadjusted and multivariable-adjusted linear regression and mixed models to evaluate cross-sectional and longitudinal associations of the secretion score with the Montreal Cognitive Assessment, Digit Symbol Coding, and Logical Memory immediate and delayed tests-measured at baseline and months 24 and 48 of follow-up. Multivariable Cox regression evaluated associations with incident probable dementia and mild cognitive impairment, adjudicated by prespecified criteria. RESULTS: Mean age was 73 &#xb1; 9 years, 41% were women, mean eGFR was 48.2 &#xb1; 11.4 ml/min/1.73m2, median albuminuria was 14.8 [7.1-48.6] mg/g. Lower secretion score was associated with a 0.06 higher adjusted logical memory delayed score (95% CI: 0.02, 0.11) but not with other cognitive tests at baseline or longitudinal cognitive decline. After a median 4.1 years of follow-up, 118 developed probable dementia and 187 developed mild cognitive impairment. Each 1-SD lower secretion score was associated with lower risk of probable dementia (HR 0.78, 95% CI: 0.63, 0.98) but not mild cognitive impairment. CONCLUSIONS: Among Systolic Blood Pressure Intervention Trial participants with CKD, lower estimated tubular secretion was not associated with worse cognition at baseline or during longitudinal follow-up.

Journal Article

Reassessment of the effect of oral l-arginine on blood pressure: A systematic review and meta-analysis based on ambulatory blood pressure monitoring.

OBJECTIVE: This meta-analysis aimed to evaluate the effect of oral l-arginine supplementation on ambulatory blood pressure (ABP). METHODS: A systematic search of PubMed, Cochrane Library, Embase, and Web of Science databases was conducted from their inception through March 1, 2026. Randomized controlled trials (RCTs) assessing the effects of oral l-arginine intervention were included. Outcome measures included 24-h systolic blood pressure (24h SBP), 24-h diastolic blood pressure (24h DBP), daytime systolic blood pressure (dSBP), daytime diastolic blood pressure (dDBP), nighttime systolic blood pressure (nSBP), and nighttime diastolic blood pressure (nDBP). Meta-analysis was performed using Stata 17.0. The weighted mean difference (WMD) was used as the effect size, and the results were pooled with 95% confidence intervals (CIs). RESULTS: A total of 5 RCTs comprising 202 participants were included. Meta-analysis results demonstrated that oral l-arginine significantly reduced 24h SBP (WMD&#x202f;=&#x202f;-4.23&#x202f;mmHg, 95% CI [-5.87, -2.58]; P&#x202f;<&#x202f;0.01) and 24h DBP (WMD&#x202f;=&#x202f;-3.04&#x202f;mmHg, 95% CI [-4.48, -1.59]; P&#x202f;<&#x202f;0.01). Significant reductions were also observed for dSBP (WMD&#x202f;=&#x202f;-4.16&#x202f;mmHg, 95% CI [-5.90, -2.41]; P&#x202f;<&#x202f;0.01) and dDBP (WMD&#x202f;=&#x202f;-4.25&#x202f;mmHg, 95% CI [-5.85, -2.66]; P&#x202f;<&#x202f;0.01). Furthermore, oral l-arginine significantly lowered nSBP (WMD&#x202f;=&#x202f;-5.70&#x202f;mmHg, 95% CI [-7.81, -3.58]; P&#x202f;<&#x202f;0.01) and nDBP (WMD&#x202f;=&#x202f;-4.18&#x202f;mmHg, 95% CI [-6.27, -2.09]; P&#x202f;<&#x202f;0.01). CONCLUSION: Oral l-arginine supplementation significantly reduces ABP. However, the number of included studies was limited, and further validation through additional relevant research is warranted.

Arginine

Safety and efficacy of distal versus conventional radial artery cannulation for invasive blood pressure monitoring: a systematic review and meta-analysis.

To compare the safety and effectiveness of distal radial artery (DRA) versus conventional radial artery (CRA) catheterization for invasive arterial blood pressure monitoring. This meta-analysis followed PRISMA guidelines. Randomized controlled trials published up to December 30, 2025 were systematically searched in PubMed, Embase, Web of Science, the Cochrane Library, CINAHL, CNKI, Wanfang, VIP, and SinoMed. Two reviewers independently screened studies, extracted data, and assessed risk of bias. Meta-analyses were conducted using Review Manager 5.4 and Stata 18.0, and evidence quality was evaluated with the GRADE system. 12 randomized controlled trials (RCTs) involving 1,790 participants were included. For the primary outcomes, compared with CRA, DRA was associated with lower incidences of haematoma (RR&#x2009;=&#x2009;0.42, 95% CI: 0.24-0.73), catheter blockage (RR&#x2009;=&#x2009;0.33, 95% CI: 0.14-0.81), and bleeding (RR&#x2009;=&#x2009;0.25, 95% CI: 0.11-0.59), but a longer catheter insertion time (MD&#x2009;=&#x2009;26.89, 95% CI: 5.28-48.50). For the secondary outcomes, DRA was associated with a shorter haemostasis time and reduced waveform instability, with no significant differences in first-attempt success rate or pain scores. Subgroup analysis showed a higher first-attempt success rate in patients aged&#x2009;&#x2264;&#x2009;65 years (RR&#x2009;=&#x2009;1.14, 95% CI: 1.02-1.28). DRA catheterization for invasive arterial blood pressure monitoring appears to be associated with fewer complications and more stable arterial waveform acquisition than CRA catheterization, despite a longer insertion time. DRA may represent a feasible alternative in surgical and intensive care settings; however, further high-quality studies are needed to confirm its long-term safety and generalizability.

Humans

Characteristics of post-exercise responders versus non-responders following aerobic or isometric exercise in physically inactive adults of African and South Asian descent with high-normal blood pressure or grade I hypertension.

OBJECTIVE: To investigate interindividual variability in post-exercise hypotension (PEH) and to characterise cardiovascular and autonomic differences between responders and non-responders following aerobic and isometric exercise in adults of African and South Asian descent with elevated blood pressure (BP). METHODS: Physically inactive adults of African and South Asian descent living in Suriname (18-65&#x2009;years) with high-normal BP or grade I hypertension participated in a randomised controlled crossover trial. In this randomised cross-over trial, 47 adults (50.1&#x2009;&#xb1;&#x2009;10.8&#x2009;years; 38% male) with high-normal blood pressure or grade I hypertension completed three conditions: aerobic exercise (30&#x2009;min at 40-60% heart rate reserve), isometric handgrip exercise, and a non-exercise control. Ambulatory BP was assessed over 24&#x2009;h. PEH was defined as the net effect: (post-exercise&#x2009;-&#x2009;pre-exercise) - (post-control&#x2009;-&#x2009;pre-control). Participants were classified as responders if daytime BP decreased &#x2265;5&#x2009;mmHg. Arterial stiffness, cardiac, and autonomic parameters were assessed. RESULTS: Following aerobic exercise, 46% of participants were classified as systolic responders compared with 28% after isometric exercise. No baseline differences were observed in demographic or clinical characteristics between responders and non-responders, suggesting that PEH variability may reflect underlying physiological rather than clinical differences. Aerobic responders demonstrated greater reductions in aortic augmentation index (-19.4% vs. -10.9%, p&#x2009;=&#x2009;0.05), larger increases in stroke volume (+8.1 vs. -5.3&#x2009;mL, p&#x2009;=&#x2009;0.05) and cardiac output (+1.54&#x2009;&#xb1;&#x2009;1.89 vs. +0.58&#x2009;&#xb1;&#x2009;1.60&#x2009;L/min, p&#x2009;=&#x2009;0.009), and more favourable autonomic recovery. Among all variables, only the change in cardiac output was associated with PEH magnitude (r&#x2009;=&#x2009;-0.46, p&#x2009;=&#x2009;0.006). No consistent physiological differences were observed following isometric exercise. CONCLUSION: PEH following aerobic exercise is characterised by a distinct responder phenotype associated with greater reductions in aortic augmentation index and favourable cardiac adaptations. These findings highlight substantial interindividual variability in BP responses and support the need for individualised exercise strategies in hypertension management.

Adolescent

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans

Effectiveness of the DASH diet versus alternative dietary interventions for hypertension management: A systematic review and meta-analysis.

BACKGROUND: The Dietary Approaches to Stop Hypertension (DASH) diet is widely recommended for blood pressure control; however, its comparative effectiveness relative to other structured dietary interventions remains uncertain. OBJECTIVE: To evaluate the comparative effectiveness of the DASH diet versus alternative dietary interventions on blood pressure and cardiometabolic outcomes in adults. METHODS: A systematic review and meta-analysis of randomized controlled trials was conducted in accordance with PRISMA guidelines. Multiple databases were searched from inception to February 2026. Eligible studies included adults with elevated blood pressure or hypertension comparing the DASH diet with other dietary interventions or usual care. Continuous outcomes were pooled using random-effects models and expressed as mean differences (MD) or standardized mean differences (SMD). Risk of bias was assessed using the Cochrane RoB 2 tool, and certainty of evidence was evaluated using the GRADE approach. RESULTS: A total of 22 randomized controlled trials were included in the qualitative synthesis, of which 10 were included in the meta-analysis. The DASH diet did not demonstrate a statistically significant advantage over comparator diets in reducing systolic blood pressure (MD = 1.30; 95% CI: -1.54 to 4.14) or diastolic blood pressure (MD = 0.21; 95% CI: -3.72 to 4.14), with substantial heterogeneity observed across studies. Significant effects were identified for selected cardiometabolic outcomes, including reductions in urinary sodium excretion (MD = -32.89; 95% CI: -62.76 to -3.01), LDL cholesterol (MD = -8.59; 95% CI: -14.64 to -2.54), and glycated hemoglobin (HbA1c) (MD = -0.49; 95% CI: -0.52 to -0.46), as well as an increase in urinary potassium excretion (MD = 11.76; 95% CI: 4.08 to 19.44). The certainty of evidence ranged from moderate to very low across outcomes. CONCLUSIONS: The DASH diet was not superior to other dietary interventions in reducing blood pressure; however, it demonstrated consistent benefits in selected cardiometabolic parameters. Given the overall low certainty of evidence and substantial heterogeneity, these findings should be interpreted cautiously. Future research should focus on well-designed trials with standardized outcomes and longer follow-up to clarify comparative effectiveness.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Association between pulse pressure and markers of cognitive function: a systematic review and meta-analysis.

Our aim was to systematically review and meta-analyse evidence on the association between pulse pressure (PP) and cognitive function using PubMed, PsycInfo, Embase and Scopus (inception-July 2025) publication databases. Studies were included if they reported an association between PP and cognitive function and summarized narratively and by performing fixed-effects meta-analysis. The search identified 4171 publications with 43 studies meeting inclusion criteria. Domains assessed included global cognition, memory, language, attention, executive function, processing speed and visuospatial ability. Meta-analysis suggests a positive association between PP and global cognition, and a negative association with memory in both cross-sectional and longitudinal studies with inconsistent findings from narratively summarized studies. Processing speed, executive function and language negatively associated with PP in cross-sectional studies with limited evidence provided by longitudinal studies or narratively summarized studies. There was limited evidence of an association with attention and visuospatial ability.

Humans

Effects of intradialytic nutrition on dialysis adequacy and fatigue in hemodialysis patients: a randomized crossover study.

OBJECTIVE: To assess intradialytic nutrition's effects on dialysis adequacy and fatigue in maintenance hemodialysis patients. METHODS: A randomized, two-period, two-sequence, self-controlled crossover trial was conducted in two outpatient hemodialysis centers in T&#xfc;rkiye. Thirty-six patients were randomized; 32 completed both periods. The participants received standardized intradialytic nutrition in one period and no food intake during the control period. Dialysis adequacy was evaluated using the urea reduction ratio and single-pool Kt/V. Intradialytic blood pressure was recorded during dialysis sessions, and fatigue severity was measured using the Piper Fatigue Scale at the end of each period. RESULTS: No significant differences were observed in dialysis adequacy or fatigue scores between the two periods. Intradialytic nutrition was associated with greater reductions in systolic and diastolic blood pressure, particularly during the second hour of dialysis. No clinically relevant adverse events occurred. CONCLUSION: Intradialytic nutrition did not compromise dialysis adequacy or worsen fatigue severity but was associated with increased intradialytic blood pressure reductions. Individualized clinical decisions and careful hemodynamic monitoring are warranted when implementing intradialytic nutritional interventions. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT07687498.

Humans

Efficacy and Safety Profile of a Triple Single-Pill Combination of Valsartan/Amlodipine/Chlorthalidone in Patients with Uncontrolled Hypertension.

PURPOSE: This randomized, double-blind, multicenter Phase III study evaluated the efficacy and safety profile of a single-pill triple combination of valsartan/amlodipine/chlorthalidone (KDF1901, Valdipine Plus) compared with a dual combination of valsartan/amlodipine (KDF1901-R) in patients with essential hypertension. METHODS: Patients (n = 294) with inadequately controlled hypertension after a 4-week run-in phase with valsartan/amlodipine (80/5 mg) were randomized to receive KDF1901 (valsartan/amlodipine/chlorthalidone 160/10/25 mg, n = 147) or KDF1901-R (valsartan/amlodipine 160/10 mg, n = 147) for 8 weeks. The primary efficacy endpoint was the change in mean sitting systolic blood pressure (MSSBP) from baseline to week 8. Secondary endpoints included changes in mean sitting diastolic blood pressure (MSDBP), BP normalization rates, and response rates. Safety profile outcomes assessed treatment-emergent adverse events (TEAEs), laboratory parameters, and serious adverse events. FINDINGS: At week 8, the KDF1901 group exhibited a significantly greater reduction in MSSBP (-22.8 &#xb1; 1.0 mmHg) compared with the dual therapy group (-16.7 &#xb1; 1.0 mmHg, P < 0.0001). Similarly, the mean MSDBP reduction was significantly greater with KDF1901 (P = 0.0006). BP normalization rates (75.9% vs 54.5%, P < .0001) and response rates (73.8% vs 51.7%, P < 0.0001) were significantly higher in the triple combination group. Overall, the incidence of TEAEs was similar between groups (24.7% vs 21.5%, P = 0.5783), with mild cases of dizziness were most commonly reported. Exploratory ad hoc analyses showed statistically greater changes in sodium, potassium, and uric acid levels with triple therapy, but clinically meaningful extreme electrolyte abnormalities were rare in both groups, and the overall laboratory profile remained acceptable. IMPLICATIONS: This trial reported that the single-pill triple combination KDF1901 significantly improved BP control compared with dual therapy without compromising tolerability. GOV IDENTIFIER: NCT07116863.

Humans

Effects of automated massage chair therapy on mental health and physical health: A comprehensive study.

BACKGROUND AND OBJECTIVE: Automated massage chair therapy is a non-pharmacological intervention widely believed to enhance wellness, yet evidence regarding its effects remains limited. This 3-part study evaluated the effects of automated massage chair therapy on mental and physical health. METHODS: In Part 1, 20 moderately stressed students were randomized to receive a 20-minute automated massage chair therapy session followed by a 20-minute control session, or vice versa, with a 48-hour washout period. Blood pressure (BP), heart rate (HR), electroencephalogram (EEG), State-Trait Anxiety Inventory (STAI), and Visual Analog Scale (VAS) were measured. In Part 2, 20 hypertensive hospital staff received three 20-minute automated massage chair therapy sessions on alternate days. BP, HR, and skin blood flow (SBF) were measured. In Part 3, 20 hospital staff with chronic low back pain received three 20-minute automated massage chair therapy sessions on alternate days. Electromyogram (EMG) and VAS were measured. RESULTS: Automated massage chair therapy significantly reduced diastolic blood pressure (DBP), HR, stress, and anxiety among moderately stressed students. In hospital staff with hypertension, SBF did not change significantly, whereas BP and HR decreased significantly after automated massage chair therapy. In hospital staff with chronic low back pain, low back function improved, and pain was significantly reduced after automated massage chair therapy. CONCLUSION: These findings indicate that automated massage chair therapy may help reduce stress, lower blood pressure, and alleviate low back pain.

Humans

HYPNOSA: Study protocol for a prospective observational cohort of patients with obstructive sleep apnea.

BACKGROUND: Obstructive Sleep Apnea (OSA) is a common chronic disease that affects more than 20% of the adult population. One of the most frequent and characteristic symptoms of OSA is excessive daytime sleepiness (EDS). This symptom is typically treated in patients with OSA with the application of continuous positive airway pressure (CPAP), the gold-standard treatment for this disease. In some patients who are adequately treated with CPAP, residual excessive daytime sleepiness (REDS) persists. The prevalence, associations, and outcomes associated with REDS remain poorly understood. METHODS: Multicenter, prospective, observational cohort study including 1000 patients. Participants will undergo a sleep study for the diagnosis of obstructive sleep apnea (OSA), 24-h ambulatory blood pressure monitoring, clinical assessment, quality-of-life questionnaires, Epworth Sleepiness Scale, and collection of biochemical variables and biological samples. Patients with OSA will receive standard care, and those prescribed continuous positive airway pressure (CPAP) will be monitored for treatment adherence. OSA patients will be assessed at baseline and at 6, 12, and 24 months. DISSCUSION: We aim to establish a prospective observational cohort of patients with obstructive sleep apnea (OSA) treated with CPAP, with and without REDS. The HYPNOSA project will create the largest available registry of patients with OSA and REDS using real-world data, providing accurate prevalence estimates and long-term outcomes. Biological samples will be analyzed to assess the role of specific biomarkers. TRIAL REGISTRATION: Registered at ClinicalTrials.gov. Identifer: NCT06514482.

Adult