Search PubMedSearch

PubMed · 42360599

Safety and efficacy of distal versus conventional radial artery cannulation for invasive blood pressure monitoring: a systematic review and meta-analysis.

Abstract

To compare the safety and effectiveness of distal radial artery (DRA) versus conventional radial artery (CRA) catheterization for invasive arterial blood pressure monitoring. This meta-analysis followed PRISMA guidelines. Randomized controlled trials published up to December 30, 2025 were systematically searched in PubMed, Embase, Web of Science, the Cochrane Library, CINAHL, CNKI, Wanfang, VIP, and SinoMed. Two reviewers independently screened studies, extracted data, and assessed risk of bias. Meta-analyses were conducted using Review Manager 5.4 and Stata 18.0, and evidence quality was evaluated with the GRADE system. 12 randomized controlled trials (RCTs) involving 1,790 participants were included. For the primary outcomes, compared with CRA, DRA was associated with lower incidences of haematoma (RR = 0.42, 95% CI: 0.24-0.73), catheter blockage (RR = 0.33, 95% CI: 0.14-0.81), and bleeding (RR = 0.25, 95% CI: 0.11-0.59), but a longer catheter insertion time (MD = 26.89, 95% CI: 5.28-48.50). For the secondary outcomes, DRA was associated with a shorter haemostasis time and reduced waveform instability, with no significant differences in first-attempt success rate or pain scores. Subgroup analysis showed a higher first-attempt success rate in patients aged ≤ 65 years (RR = 1.14, 95% CI: 1.02-1.28). DRA catheterization for invasive arterial blood pressure monitoring appears to be associated with fewer complications and more stable arterial waveform acquisition than CRA catheterization, despite a longer insertion time. DRA may represent a feasible alternative in surgical and intensive care settings; however, further high-quality studies are needed to confirm its long-term safety and generalizability.

Explore related subjects

Keep this discovery

BibTeXRIS

Tian Hao, Yuhan Sha, Wenxiu Niu, Haohao Xie, Jie Cheng, Lin Zhang, Ruirui Qi, Xiaomeng Han, Fei Zheng, Tingwei Wang, Ruofan Zhang, Jie Li, Kejing Mu, Zhan Hao, Zhigang Zhang. 2026-06-26. Safety and efficacy of distal versus conventional radial artery cannulation for invasive blood pressure monitoring: a systematic review and meta-analysis.. https://doi.org/10.1007/s10877-026-01451-x

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Distal versus proximal radial access for diagnostic cerebral angiography: comparative outcomes and learning curve analysis.

BACKGROUND AND PURPOSE: Distal transradial access (dTRA) is an alternative to proximal transradial access (pTRA) for neuroangiography, but comparative real-world data and evidence on its early learning curve remain limited. We compared procedural performance and access-site complications between dTRA and pTRA and evaluated the early learning curve of dTRA. METHODS: We retrospectively analyzed 470 diagnostic cerebral angiography procedures, representing 421 unique patients, performed via radial access at a single center between January 2025 and February 2026, including 237 dTRA and 233 pTRA procedures. Baseline characteristics, including age, sex, body mass index (BMI) category, aortic arch type, and antiplatelet/anticoagulant use, procedural performance, and clinically assessed access-site events were compared between groups. Radial artery occlusion (RAO) was assessed by postoperative bedside pulse examination and confirmed with Doppler ultrasound when clinical findings were uncertain. Multivariable logistic regression was used to evaluate predictors of RAO, persistent bleeding or repeated compression, hand edema, and a composite access-site event endpoint. Because repeated procedures occurred in a subset of patients and event counts were limited, first-procedure sensitivity analysis and analyses of infrequent outcomes were interpreted cautiously. The dTRA learning process was assessed in the first 100 dTRA cases performed by a single operator using multivariable regression, cumulative sum (CUSUM) analysis, segmented trend analysis, and phase-based comparisons. RESULTS: Baseline characteristics were comparable between groups, including age, male sex, BMI category, aortic arch type, and antiplatelet/anticoagulant use. Compared with pTRA, dTRA was associated with more puncture attempts (3.0 [2.0-4.0] vs 2.0 [1.0-3.0], P&#xa0;<&#xa0;0.001), longer puncture time (2.0 [1.0-5.0] vs 2.0 [1.0-3.0] min, P&#xa0;=&#xa0;0.003), lower first-pass success (19.4% vs 35.2%, P&#xa0;<&#xa0;0.001), and a higher crossover rate (11.4% vs 6.0%, P&#xa0;=&#xa0;0.037). However, dTRA was associated with a lower clinically assessed RAO rate (2.5% vs 7.7%, P&#xa0;=&#xa0;0.011). On multivariable analysis, pTRA was independently associated with higher odds of RAO (OR 3.27, 95% CI 1.26-8.49, P&#xa0;=&#xa0;0.015) and the composite access-site event endpoint (OR 3.12, 95% CI 1.55-6.28, P&#xa0;=&#xa0;0.001). Similar findings were observed in a sensitivity analysis restricted to the first procedure per patient. In the first 100 dTRA cases, cumulative dTRA experience was independently associated with shorter total procedure time (beta&#xa0;=&#xa0;-0.074&#xa0;min/case, P&#xa0;=&#xa0;0.009), while CUSUM and moving-average analyses suggested that the major learning effect occurred within approximately the first 10-15 cases. CONCLUSIONS: In this retrospective single-operator cohort, dTRA was associated with lower clinically assessed RAO than pTRA despite greater access difficulty. The early learning effect was mainly reflected in shorter total procedure time. These findings support the feasibility of dTRA but should be interpreted cautiously given the study's observational design and limited anatomical data.

Humans

Closed-loop vasopressor systems for hemodynamic control in perioperative and critical care settings: a systematic review and meta-analysis.

Maintaining mean arterial pressure (MAP) within a predefined target is central to haemodynamic management in surgical and critically ill adults receiving vasopressors. Closed-loop vasopressor (CLV) systems automate titration to optimise blood pressure control, but their clinical effectiveness remains uncertain. We performed a systematic review and meta-analysis comparing CLV with manual titration. This PRISMA 2020-compliant review was prospectively registered in PROSPERO (CRD420250655697). MEDLINE, Embase, Scopus, Web of Science, CENTRAL, and the Cochrane Library were searched (January 2000-June 2025). Randomised controlled trials enrolling adults receiving vasopressors in perioperative or intensive care settings were included. Primary outcomes were time within the MAP target range and time spent in hypotension or hypertension. Risk of bias was assessed using RoB 2.0 and certainty of evidence using GRADE. Random- or fixed-effects models were selected according to heterogeneity. Six randomized controlled trials (215 patients) were included in the systematic review, whereas five perioperative trials contributed to the meta-analysis of haemodynamic control outcomes, and one ICU-based study was summarized narratively because it did not report comparable MAP control endpoints. CLV increased time within the MAP target range (mean difference [MD] 33.94%, 95% CI 20.41-47.46; I2&#x2009;=&#x2009;77%) and reduced time in hypotension (MD&#x2009;-&#x2009;18.24%, 95% CI&#x2009;-&#x2009;28.95 to&#x2009;-&#x2009;7.53; I2&#x2009;=&#x2009;73%). There was no significant difference in time in hypertension, cumulative norepinephrine dose, or major/minor adverse events. ICU length of stay was not pooled because of clinical and methodological heterogeneity. Certainty of evidence ranged from low to high (moderate for haemodynamic control outcomes). CLV systems improved haemodynamic control, primarily in perioperative settings,&#xa0;but heterogeneity and small samples limit confidence in effect size and generalisability.&#xa0;Evidence in critically ill populations remains limited, and larger trials are needed to determine whether improvements in these physiological surrogate endpoints translate into meaningful patient-centred outcomes.

Humans

The effect of dietetic counseling combined with digital tools intervention on hemodynamic markers in Greek adults: The GATEKEEPER Study.

BACKGROUND AND AIM: Hypertension is a leading cardiovascular risk factor with substantial global impact on morbidity, mortality, and healthcare costs. While lifestyle interventions remain central to management, mHealth technologies offer promising adjunctive support, though their clinical effectiveness remains uncertain. This study evaluated whether combining dietetic counseling with digital tools improves hemodynamic markers in adults aged &#x2265;55 years with increased cardiometabolic risk. METHODS AND RESULTS: This 3-month RCT (NCT05031299) included 954 adults with at least one metabolic syndrome risk factor, allocated 1:1:1 to Standard Care (dietetic counseling), Platform (counseling plus web-based platform), or Platform&#xa0;+&#xa0;Devices (counseling plus platform plus wearables). Outcomes included anthropometrics, lifestyle characteristics, blood pressure, pulse pressure, and estimated pulse wave velocity, analyzed using linear mixed-effects models adjusted for age and sex. All groups improved over 3 months. Waist circumference decreased by -6.29, -4.92, and -4.69&#xa0;cm across Standard Care, Platform, and Platform&#xa0;+&#xa0;Devices groups respectively, and systolic blood pressure declined by -4.84 to -7.15&#xa0;mmHg across groups. The Platform&#xa0;+&#xa0;Devices group showed greater increases in physical activity (94.62 MET-min/week; 95% CI 66.49 to 122.76) and greater reductions in pulse pressure (-3.90&#xa0;mmHg; -6.58 to -1.22) versus Standard Care. Weight loss was associated with lower odds of hypertension (OR 0.4; 95% CI 0.2-0.7), greater likelihood of hypertension reversal (OR 3.6; 1.2-10.3), and higher probability of achieving normal pulse pressure (OR 1.8; 1.1-3.1). CONCLUSIONS: Dietary lifestyle intervention improved cardiometabolic outcomes, with limited added benefit from digital tools. Weight loss was the primary driver of hemodynamic improvement.

Aged