Search PubMedSearch

SEARCH · Search PubMed

Results for “Ambulatory ECG”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 recordsLinked to original sources

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Ultra-high-frequency ECG quantifies residual electrical dyssynchrony during left bundle branch area pacing in patients with wide QRS: a paired within-patient study.

BACKGROUND: Left bundle branch area pacing (LBBAP) may restore a more physiological pattern of ventricular activation in patients with conduction delay; however, QRS narrowing alone may incompletely characterize electrical resynchronization. Ultra-high-frequency ECG (UHF-ECG) provides quantitative markers of ventricular activation timing and dyssynchrony. OBJECTIVE: To quantify paired OFF-to-ON changes in conventional ECG and UHF-ECG metrics during LBBAP in patients with baseline wide QRS and to assess the relationship between paced R-wave peak time (RWPT) and residual UHF-ECG dyssynchrony. METHODS: In this prospective single-center paired study, 21 patients with bradycardia and baseline wide QRS underwent standard ECG and UHF-ECG assessment during intrinsic rhythm (pacing OFF) and during LBBAP (pacing ON). Endpoints included QRS duration, signed VED16, absolute VED16 (|VED16|), mean ventricular delay (meanVD), and a clinically interpretable distance-to-normal metric defined as dist&#xa0;=&#xa0;max(|VED16|-20, 0). Paired changes were summarized as medians with bootstrap 95% confidence intervals and tested using the Wilcoxon signed-rank test. Associations between paced RWPT and residual dyssynchrony during pacing were evaluated using Pearson and Spearman correlation coefficients. RESULTS: LBBAP significantly narrowed QRS duration from 136.8 [130.2-153.6] ms during intrinsic rhythm to 116.0 [107.8-125.6] ms during pacing (median &#x394; -21.0&#xa0;ms; 95% CI -33.9 to -18.6; p&#xa0;<&#xa0;0.001). Signed VED16 did not change significantly (median &#x394; 0.4&#xa0;ms; p&#xa0;=&#xa0;1.000), consistent with the mixed conduction-phenotype composition of the cohort. In contrast, severity-oriented UHF-ECG endpoints improved: |VED16| decreased numerically (median &#x394; -5.2&#xa0;ms; p&#xa0;=&#xa0;0.070), whereas dist decreased significantly (median &#x394; -0.7&#xa0;ms; 95% CI -14.4 to 0.0; p&#xa0;=&#xa0;0.015). The proportion of patients within the normal dyssynchrony band (|VED16|&#xa0;&#x2264;&#xa0;20&#xa0;ms) increased from 7/21 (33.3%) to 12/21 (57.1%). Median paced RWPT was 66.6 [58.6-74.6] ms, and shorter RWPT correlated with lower residual |VED16| during pacing (Pearson r&#xa0;=&#xa0;-0.45, p&#xa0;=&#xa0;0.038). CONCLUSIONS: In patients with baseline wide QRS, LBBAP produces marked QRS narrowing, whereas UHF-ECG provides complementary quantification of residual electrical dyssynchrony. Severity-oriented UHF-ECG endpoints, particularly a distance-to-normal metric, may offer an interpretable mechanistic framework beyond conventional ECG alone. Shorter paced RWPT was associated with lower residual dyssynchrony during pacing, supporting physiological coherence between procedural and high-resolution electrocardiographic markers.

Humans

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Teaching Acute Coronary Syndrome High-Risk ECG Interpretation and Clinical Decision-Making Through FOAMed Videos and Podcast Versus Print-Based Materials Among Emergency Care Providers: Randomized Controlled Mixed Methods Trial.

BACKGROUND: Accurate interpretation of high-risk acute coronary syndrome (ACS) electrocardiograms (ECGs) is essential for early diagnosis and timely reperfusion, yet substantial deficits persist across health care professions. Digital self-learning formats such as FOAMed (Free Open Access Medical Education) are widely used, but their effectiveness has rarely been evaluated for complex, high-risk ACS ECG patterns. Existing ECG education studies often focus on students or single professional groups and established ST-segment elevation myocardial infarction (STEMI) criteria, leaving newer guideline-recognized STEMI equivalents, selected emerging occlusion myocardial infarction (OMI)-related patterns, and interprofessional emergency care underrepresented. OBJECTIVE: This study aimed to compare the effectiveness of FOAMed podcast and videos versus traditional print-based materials for teaching high-risk ACS ECG patterns and related clinical decision-making in emergency providers. METHODS: We conducted a prospective, interprofessional, controlled mixed methods trial across 5 training sites in Germany. Paramedics, prehospital emergency physicians, and emergency department clinicians received either a FOAMed multimedia module or print-based materials through concealed allocation; deviations from the intended 1:1 ratio resulted from participant no-shows. The intervention consisted of a 30-minute supervised self-learning session. In total, 103 participants were allocated to FOAMed (n=45) or print-based materials (n=58). Two coprimary outcomes were assessed: ECG interpretation accuracy and text-based ACS clinical decision-making. Secondary outcomes included subjective confidence, learning experience, and exploratory qualitative free-text responses. Outcome assessment was automated and blinded; mixed ANOVA was the primary analysis. The study was not prospectively registered because it assessed educational outcomes in health care professionals rather than patient health outcomes. RESULTS: All 103 participants completed the study. Both groups improved, with greater gains in the FOAMed group: ECG interpretation increased from 55% to 65.5% and text-based ACS clinical decision-making from 45% to 68%, versus 57% to 60% and from 47% to 63%, respectively, in the print-based group. Effect sizes were &#x3b7;&#xb2;=0.055 for ECG interpretation and &#x3b7;&#xb2;=0.044 for clinical decision-making. Exploratory subgroup analyses provided no evidence of differential effects across age, gender, or professional background and were likely underpowered. Qualitative responses (46 and 37 entries) provided contextual insights into perceived clarity, engagement, and practical relevance supporting the quantitative findings. CONCLUSIONS: This study is innovative in directly comparing a curated FOAMed multimedia module with selected print-based materials in an interprofessional emergency care population. It differs from existing research by focusing on subtle, emerging ischemic patterns and evaluating realistic, time-limited self-learning formats. The findings provide evidence that curated FOAMed resources can produce greater short-term improvements in ECG interpretation and text-based ACS clinical decision-making than traditional print-based materials in this setting. Although implications for clinical performance remain hypothetical, concise, high-quality digital modules may represent a practical supplement to structured continuing education in emergency care.

Humans

Spatial proximity or vector orientation? Re-evaluating ECG interpretation in anterior myocardial infarction using cardiac magnetic resonance.

BACKGROUND: The electrocardiogram (ECG) is widely used to infer infarct location and extent in anterior myocardial infarction (MI), based on either anatomical lead proximity or vectorial orientation of ST-segment deviation. However, the validity of these approaches against direct imaging of myocardial injury remains uncertain. METHODS: In this prospective study, 105 patients with anterior MI underwent cardiac magnetic resonance (CMR) imaging 3-7&#xa0;days after presentation. Admission ECGs were analyzed using (1) conventional ECG localization categories, and (2) simplified frontal and horizontal ST-axis orientation. CMR-defined injury distribution was assessed using late gadolinium enhancement and myocardial edema imaging. RESULTS: Conventional ECG localization categories demonstrated no significant association with CMR-defined infarct distribution (P&#xa0;=&#xa0;0.24), with poor agreement (&#x3ba;&#xa0;=&#xa0;0.122) and substantial overlap across categories. Simplified ST-axis orientation showed modest and inconsistent associations with infarct location and did not meaningfully explain infarct size. In contrast, global ST-segment burden was associated with CMR-defined infarct size (&#x3a3;STE: standardized &#x3b2;&#xa0;=&#xa0;0.307, P&#xa0;=&#xa0;0.002; lead count: standardized &#x3b2;&#xa0;=&#xa0;0.267, P&#xa0;=&#xa0;0.007). CONCLUSIONS: In this selected cohort of reperfused LAD-related anterior STEMI patients undergoing early CMR, conventional ECG localization categories and simplified ST-axis orientation showed poor or inconsistent correspondence with CMR-defined infarct distribution, whereas global ST-segment burden showed a modest association with infarct size. These findings suggest that, in this cohort, the ECG may be better suited to reflect the extent of myocardial injury rather than its precise anatomical location.

Humans

First evaluation of a novel recombinant eCG molecule in ewes reveals a discrepancy between ovulatory response and pregnancy outcome.

This study evaluated the reproductive performance and clinical safety of a novel recombinant eCG (r-eCG) in ewes. Two weeks prior to study onset (Day 0: intravaginal progesterone device insertion), 45 ewes were randomly assigned to negative control (NC; no eCG; n&#x202f;=&#x202f;10), positive control (PC; 400IU commercial non-recombinant eCG; n&#x202f;=&#x202f;20), or treatment group (T; 400IU r-eCG; n&#x202f;=&#x202f;15). Ewes were inseminated with fresh-diluted semen (200&#x202f;&#xd7;&#x202f;106 sperm). Ultrasonography assessed follicle count/diameter (days 11, 13), ovulation (day 13), corpus luteum (CL) number/characteristics (day 20), and pregnancy (day 44). Serum progesterone was measured on day 20; Group T underwent clinical/hematological evaluations (days 0, 20, and 44). Estrus signs were more frequent (P&#x202f;<&#x202f;0.01) in T (100%) than NC (50%), while PC (85%) did not differ. Ovulation rates were similar between T (93%) and PC (95%), but higher than NC (50%; P&#x202f;<&#x202f;0.05). On day 13, largest follicle diameter did not differ (P&#x202f;>&#x202f;0.05) among groups; however, fewer follicles > 2&#x202f;mm occurred in PC than NC and T (P&#x202f;<&#x202f;0.05). CL number was higher in T than PC (2.0&#x202f;&#xb1;&#x202f;0.3 vs. 1.0&#x202f;&#xb1;&#x202f;0.0, P&#x202f;<&#x202f;0.01), while NC did not differ (1.0&#x202f;&#xb1;&#x202f;0.25). Conversely, pregnancy rate was higher (P&#x202f;<&#x202f;0.05) in PC (70%) than T (28.6%) and NC (20%). Among ovulated ewes, progesterone concentration and progesterone/CL ratio did not differ among groups (P&#x202f;=&#x202f;0.92 and P&#x202f;=&#x202f;0.08, respectively). No relevant r-eCG-related clinical or hematological alterations occurred. In conclusion, 400IU r-eCG effectively induces estrus and ovulation without adverse effects; however, the discrepancy between ovulatory response and pregnancy rate underscores the need for further study refinement to improve fertility.

Animals

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Reassessment of the effect of oral l-arginine on blood pressure: A systematic review and meta-analysis based on ambulatory blood pressure monitoring.

OBJECTIVE: This meta-analysis aimed to evaluate the effect of oral l-arginine supplementation on ambulatory blood pressure (ABP). METHODS: A systematic search of PubMed, Cochrane Library, Embase, and Web of Science databases was conducted from their inception through March 1, 2026. Randomized controlled trials (RCTs) assessing the effects of oral l-arginine intervention were included. Outcome measures included 24-h systolic blood pressure (24h SBP), 24-h diastolic blood pressure (24h DBP), daytime systolic blood pressure (dSBP), daytime diastolic blood pressure (dDBP), nighttime systolic blood pressure (nSBP), and nighttime diastolic blood pressure (nDBP). Meta-analysis was performed using Stata 17.0. The weighted mean difference (WMD) was used as the effect size, and the results were pooled with 95% confidence intervals (CIs). RESULTS: A total of 5 RCTs comprising 202 participants were included. Meta-analysis results demonstrated that oral l-arginine significantly reduced 24h SBP (WMD&#x202f;=&#x202f;-4.23&#x202f;mmHg, 95% CI [-5.87, -2.58]; P&#x202f;<&#x202f;0.01) and 24h DBP (WMD&#x202f;=&#x202f;-3.04&#x202f;mmHg, 95% CI [-4.48, -1.59]; P&#x202f;<&#x202f;0.01). Significant reductions were also observed for dSBP (WMD&#x202f;=&#x202f;-4.16&#x202f;mmHg, 95% CI [-5.90, -2.41]; P&#x202f;<&#x202f;0.01) and dDBP (WMD&#x202f;=&#x202f;-4.25&#x202f;mmHg, 95% CI [-5.85, -2.66]; P&#x202f;<&#x202f;0.01). Furthermore, oral l-arginine significantly lowered nSBP (WMD&#x202f;=&#x202f;-5.70&#x202f;mmHg, 95% CI [-7.81, -3.58]; P&#x202f;<&#x202f;0.01) and nDBP (WMD&#x202f;=&#x202f;-4.18&#x202f;mmHg, 95% CI [-6.27, -2.09]; P&#x202f;<&#x202f;0.01). CONCLUSION: Oral l-arginine supplementation significantly reduces ABP. However, the number of included studies was limited, and further validation through additional relevant research is warranted.

Arginine

Preoperative Olanzapine and Quality of Recovery after Ambulatory Surgery: A Randomized Clinical Trial.

BACKGROUND: Postdischarge nausea and vomiting negatively impact recovery after surgery. Preoperative administration of 10&#x2009;mg olanzapine decreases postdischarge nausea and vomiting but increases sedation. No data are available on the impact of olanzapine on global quality of recovery. METHODS: This was a single-center, randomized, double-blind, placebo-controlled trial in female patients 18 to 50 yr old undergoing ambulatory surgery during general anesthesia. Participants received 5&#x2009;mg oral olanzapine or placebo in addition to antiemetic prophylaxis with dexamethasone and ondansetron. The primary outcome was Quality of Recovery-40 (QoR-40) on postoperative day (POD) 1. Secondary outcomes included QoR-40 on POD 2, postdischarge nausea (any and severe) through POD 2, and postanesthesia care unit length of stay. QoR-40 analyses used mixed-effects models adjusted for baseline preoperative QoR-40 scores. The group differences and corresponding 95% CI are reported. RESULTS: A total of 384 participants received olanzapine (n = 191) or placebo (n = 193). Compared with placebo, olanzapine was associated with higher QoR-40 scores on POD 1 (difference, 9.0 points; 95% CI, 6.1 to 11.8; P < 0.001). The POD 2 difference was 4.8 points (95% CI, 2.0 to 7.6; nominal P = 0.001), and this secondary outcome remained significant after false discovery rate correction. Olanzapine was associated with lower odds of any nausea (odds ratio [OR], 0.43; 95% CI, 0.28 to 0.66) and severe nausea (OR, 0.26; 95% CI, 0.14 to 0.48) on POD 1. On POD 2, olanzapine was associated with lower odds of any nausea (OR, 0.48; 95% CI, 0.30 to 0.76), but not severe nausea (OR, 0.65; 95% CI, 0.30 to 1.40). Postanesthesia care unit length of stay did not differ between groups. The significance of these prespecified secondary outcomes was unchanged after false discovery rate correction. CONCLUSIONS: When combined with dexamethasone and ondansetron, a single preoperative dose of 5&#x2009;mg olanzapine improved global quality of recovery after discharge from ambulatory surgery.

Humans

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Electrocardiographic correlates of pacing induced cardiomyopathy and response to cardiac resynchronization therapy.

BACKGROUND: Chronic right ventricular (RV) pacing (RVP) causes pacing-induced cardiomyopathy (PICM) in only a small number of patients. We evaluated ECG correlates of (i) PICM and (ii) response to cardiac resynchronization therapy (CRT) upgrade. METHODS: We conducted a retrospective case-control study by including all CRT upgrades for PICM (LVEF <50%) at our center between 2014 and 2018. Controls were patients with &#x2265;5 ECGs all demonstrating RVP over &#x2265;2&#xa0;years and all echocardiographic LVEF &#x2265;50%. Root-summed-squared (3D) ECG was obtained from reconstructed vectorcardiographic X-Y-Z leads. Predictors of PICM and CRT response were assessed as area under ROC curve (AUC) for pre-CRT and &#x394; (post-CRT - pre-CRT) ECG intervals and QRS voltage-time-integrals (VTI). RESULTS: We included 104 patients with CRT upgrade for PICM (age 73.7&#xa0;&#xb1;&#xa0;10.5&#xa0;years, female 29.1%, QRS duration 167.8&#xa0;&#xb1;&#xa0;25.2&#xa0;ms, LVEF 28.8&#xa0;&#xb1;&#xa0;8.0%, &#x394;LVEF 13.8&#xa0;&#xb1;&#xa0;10.3%) and 178 controls without PICM (age 73.2&#xa0;&#xb1;&#xa0;14.9&#xa0;years, female 52.8%, QRS duration 144.0&#xa0;&#xb1;&#xa0;20.9&#xa0;ms, LVEF 56.7&#xa0;&#xb1;&#xa0;5.2%). PICM was best identified by VTIQRS-3D (AUC 0.851; VTIQRS-3D&#xa0;&#x2265;&#xa0;80 &#x3bc;Vs sensitivity 87.5%, specificity 63.5%), VTIQRS-Y (0.846), and QRS duration (0.775). CRT response (LVEF increase &#x2265;10% at 3-12&#xa0;months) occurred in 73/104 (70.2%) patients. Lack of CRT response was best predicted by longer pre-CRT QRS duration (AUC 0.640; QRS duration &#x2265;180&#xa0;ms sensitivity 45.2%, specificity 83.6%), and less &#x394;VTIQRS-3D (0.609) and &#x394;VTIQRS-X (0.608). CONCLUSION: In patients with chronic RVP, VTIQRS-3D&#xa0;&#x2265;&#xa0;80 &#x3bc;Vs can be used as a screening test for echocardiographic confirmation of PICM. RV-paced QRS duration >180&#xa0;ms, on the other hand, identifies those who may not respond to CRT upgrade.

Humans

Systematic multi-domain screening of lead-specific electrocardiographic features associated with sudden cardiac death.

UNLABELLED: Electrocardiogram (ECG) provides four-dimensional view to the electrical properties of the heart. We performed a comprehensive multi-domain screening to find the most significant lead-specific ECG features associated with sudden cardiac death (SCD). METHODS: We analyzed retrospective data from 21,176 consecutive patients undergoing coronary angiography in Tampere University Hospital between 2007 and 2018. 937 ECG variables provided by the 12SL algorithm were used for the analysis. From those, the significant lead-specific ECG variables were categorized into three subgroups: P-wave, QRS complex, and ST-segment/T-wave. The most significant (i.e., lowest P-value) independent lead-specific ECG variables were tested in multivariate analysis after filtering correlating variables with weaker associations with SCD. RESULTS: Among ventricular depolarization (QRS complex) variables, the strongest associations with SCD were observed for QRS intrinsicoid deflection (lead I) (p&#xa0;=&#xa0;4.6&#xa0;&#xd7;&#xa0;10-8), QRS peak-to-peak amplitude (lead aVR) (p&#xa0;=&#xa0;1.9&#xa0;&#xd7;&#xa0;10-5), and Q-wave amplitude (lead V1) (p&#xa0;=&#xa0;7.6&#xa0;&#xd7;&#xa0;10-6). Among repolarization (ST-segment and T-wave) variables, the strongest predictors of SCD were T-wave amplitude (lead aVR) (p&#xa0;=&#xa0;3.5&#xa0;&#xd7;&#xa0;10-7) and ST-segment end amplitude (lead aVL) (p&#xa0;=&#xa0;8.1&#xa0;&#xd7;&#xa0;10-5). The strongest associations with SCD among atrial depolarization (P-wave) variables were P-wave onset amplitude (lead V6) (p&#xa0;=&#xa0;3.1&#xa0;&#xd7;&#xa0;10-6), P'-wave amplitude (lead V2) (p&#xa0;=&#xa0;2.1&#xa0;&#xd7;&#xa0;10-5), and P-wave duration (lead V2) (p&#xa0;=&#xa0;2.4&#xa0;&#xd7;&#xa0;10-3). These variables remained significant in multivariate analysis alongside global ECG variables (e.g., heart rate, QRS duration, and LVH). CONCLUSION: Systematic screening and utilizing the full prognostic potential of the 12&#x2011;lead ECG reveal several key elements of the electrical properties of the heart that associate with SCD.

Humans

Intensive glycemic control in adults aged 80&#xa0;years and older: A randomized trial evaluating diabetes complications and competing mortality.

AIMS: To evaluate whether intensive glycemic control reduces microvascular or macrovascular events compared with conservative glycemic targets in independently ambulatory adults aged 80&#xa0;years or older with type 2 diabetes. METHODS: We conducted a prospective, randomized, open-label, single-center trial enrolling independently ambulatory adults aged&#xa0;&#x2265;&#xa0;80&#xa0;years with type 2 diabetes. Participants were assigned (1:1) to an intensive glycemic target (HbA1c&#xa0;<&#xa0;7&#xa0;%) or a conservative target (HbA1c&#xa0;<&#xa0;9&#xa0;%) and followed for 5&#xa0;years. Primary outcomes were composite microvascular and macrovascular events. Analyses were done by intention to treat. Cause-specific Cox models and Fine-Gray subdistribution hazard models were used to account for all-cause mortality as a competing event. This trial is registered with ClinicalTrials.gov, NCT00850798. FINDINGS: 206 participants were randomly assigned to intensive (n&#xa0;=&#xa0;102) or conservative (n&#xa0;=&#xa0;104) treatment. At 5&#xa0;years, mean HbA1c was lower in the intensive group than in the conservative group (7&#xb7;42&#xa0;% vs 8&#xb7;21&#xa0;%; p&#xa0;=&#xa0;0&#xb7;005). Intensive therapy did not reduce microvascular events (hazard ratio [HR] 1&#xb7;24, 95&#xa0;% CI 0&#xb7;76-2&#xb7;04) or macrovascular events (HR 1&#xb7;02, 0&#xb7;36-2&#xb7;92). Competing risk analyses showed no reduction in cumulative incidence of vascular outcomes (subdistribution HR approximately 1&#xb7;0 for both). The cumulative incidence of death exceeded that of vascular events, indicating that many participants died before potential glycemic benefits could be realized. Severe hypoglycemia requiring hospitalization was more frequent with intensive therapy (7 vs 1 event). INTERPRETATION: In adults aged 80&#xa0;years or older with type 2 diabetes, intensive glycaemic control improved glycaemic levels but did not reduce vascular events and increased the risk of severe hypoglycaemia. High competing mortality substantially limits the potential long-term benefit of intensive treatment, supporting conservative and individualized glycemic targets in very old adults. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00850798.

Aged, 80 and over

HYPNOSA: Study protocol for a prospective observational cohort of patients with obstructive sleep apnea.

BACKGROUND: Obstructive Sleep Apnea (OSA) is a common chronic disease that affects more than 20% of the adult population. One of the most frequent and characteristic symptoms of OSA is excessive daytime sleepiness (EDS). This symptom is typically treated in patients with OSA with the application of continuous positive airway pressure (CPAP), the gold-standard treatment for this disease. In some patients who are adequately treated with CPAP, residual excessive daytime sleepiness (REDS) persists. The prevalence, associations, and outcomes associated with REDS remain poorly understood. METHODS: Multicenter, prospective, observational cohort study including 1000 patients. Participants will undergo a sleep study for the diagnosis of obstructive sleep apnea (OSA), 24-h ambulatory blood pressure monitoring, clinical assessment, quality-of-life questionnaires, Epworth Sleepiness Scale, and collection of biochemical variables and biological samples. Patients with OSA will receive standard care, and those prescribed continuous positive airway pressure (CPAP) will be monitored for treatment adherence. OSA patients will be assessed at baseline and at 6, 12, and 24 months. DISSCUSION: We aim to establish a prospective observational cohort of patients with obstructive sleep apnea (OSA) treated with CPAP, with and without REDS. The HYPNOSA project will create the largest available registry of patients with OSA and REDS using real-world data, providing accurate prevalence estimates and long-term outcomes. Biological samples will be analyzed to assess the role of specific biomarkers. TRIAL REGISTRATION: Registered at ClinicalTrials.gov. Identifer: NCT06514482.

Adult

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans

Feasibility and efficacy of left bundle branch area pacing guided by modified chest lead 1.

BACKGROUND: Left bundle branch area pacing (LBBAP) typically requires 12&#x2011;lead electrocardiogram (ECG) measurements using an electrophysiology (EP) recording system. However, a simplified approach using modified chest lead 1 (MCL1) is potentially feasible. This study aimed to compare the success rate and pacing outcomes of LBBAP guided by MCL1 with those guided by the 12&#x2011;lead ECG using an EP recording system. METHODS: This retrospective, single-center study included patients with preserved left ventricular ejection fraction who underwent LBBAP for bradyarrhythmia. LBBAP was either guided by 12&#x2011;lead ECG using an EP recording system or by MCL1. In the MCL1 group, a follow-up examination with a 12&#x2011;lead ECG using an EP recording system was conducted within one week postoperatively. RESULTS: A total of 65 patients underwent LBBAP (EP recording system group: n&#xa0;=&#xa0;35; MCL1 group: n&#xa0;=&#xa0;30). The overall success rate of LBBAP was 84.6%, with no significant difference between groups (88.5% vs. 80.0%, p&#xa0;=&#xa0;0.49). No significant differences were observed in the paced QRS duration (140.4&#xa0;&#xb1;&#xa0;8.0 vs. 141.9&#xa0;&#xb1;&#xa0;13.1&#xa0;ms, p&#xa0;=&#xa0;0.54), V6-V1 interpeak interval (39.7&#xa0;&#xb1;&#xa0;16.5 vs. 38.3&#xa0;&#xb1;&#xa0;15.6&#xa0;ms, p&#xa0;=&#xa0;0.79), or V6 R-wave peak time (69.8&#xa0;&#xb1;&#xa0;12.3 vs. 71.5&#xa0;&#xb1;&#xa0;12.1&#xa0;ms, p&#xa0;=&#xa0;0.68). CONCLUSIONS: MCL1-guided LBBAP was feasible and achieved a high success rate, with outcomes comparable to those of conventional EP recording system-guided implantation. This simplified approach may reduce procedural complexity and may allow LBBAP implantation without the routine use of an EP recording system.

Humans