Search PubMedSearch

SEARCH · Search PubMed

Results for “Range of Motion, Articular”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,988 records · Page 4Linked to original sources

Evidence-based insights into medial pedicle reduction mammaplasty: A systematic review and meta-analysis.

BACKGROUND: Breast reduction relieves the physical and psychosocial burden of macromastia. Medial pedicle reduction mammaplasty may enhance vascular reliability, preserve nipple-areola complex (NAC) sensation, and sustain upper pole fullness, even in large-volume reductions. The purpose of this study was to assess the outcomes of medial pedicle breast reduction. METHODS: A search across ScienceDirect, Cochrane, and PubMed was conducted. Included studies reported on perioperative outcomes and complications of medial pedicle breast reduction. Data on demographics, surgical variables, complications, sensory recovery, volumetric changes, and patient satisfaction were extracted. Proportion meta-analysis was performed, and odds ratios were calculated for comparison with inferior pedicle breast reduction. RESULTS: Twenty-five studies comprising 1033 patients met the inclusion criteria. Mean BMI ranged from 27 to 42 kg/m2, with mean resection weights between 412 and 3828 g. Mean surgical times ranged from 104 to 204 min. Pooled complication rates were low: infection 1%, seroma 1%, hematoma 1%, fat necrosis 2%, NAC necrosis 1%, dehiscence 8%, and reintervention 5%. Odds of complications did not differ significantly from inferior pedicle reductions. NAC sensation typically recovered by 6-12 months, with no long-term deficits. Volumetric analyses demonstrated stable breast shape after the first postoperative year, with superior upper pole tissue maintained. Patient satisfaction ranged 75-100%, with higher ratings for scar appearance and overall aesthetics in medial pedicle reductions. CONCLUSION: Medial pedicle breast reduction is a well-established and reproducible technique, preserving NAC sensation, achieving stable long-term shape, and enhancing upper pole fullness. It offers satisfactory aesthetic outcomes compared to other traditional methods, even in large-volume reductions.

Humans

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20 years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

Bipolar circumcision with mucocutaneous plane separation: A safe, precise, blood-sparing, dressing-free approach.

Conventional circumcision techniques may result in bleeding, limited control of the mucosal collar, and the need for dressings. We describe a modified bipolar technique enabling near-bloodless dissection with precise mucosal trimming. Following bipolar division of the preputial skin, the inner mucosa is separated using two forceps and retracted proximally, creating a protective plane for safe skin adjustment. The mucosal collar is trimmed with scissors. The wound is closed with sutures and 2-octyl cyanoacrylate, avoiding dressings. This technique has been performed in 55 consecutive cases (median age: 2 years and 2 months; range: 0 days-17 years and 5 months) with no reported complications over a median follow-up of 2 years and 7 months (range: 3 months-4 years and 1 month).

Humans

Evidence Gap in Managing Lateral Pelvic Lymph Nodes in Rectal Cancer: a Systematic Review of Radiation Boost Strategies.

PURPOSE: Lateral pelvic lymph node (LPLN) involvement is a significant predictor of local recurrence in patients with locally advanced rectal cancer (LARC). While lateral pelvic lymph node dissection (LPLND) is routinely used in some countries to manage suspicious nodes, it is associated with increased morbidity and is not widely adopted in Western practice. Radiation boost (dose escalation) to involved LPLNs during neoadjuvant chemoradiotherapy (nCRT) has emerged as a potential non-surgical alternative. Despite increasing adoption of radiation boost to clinically involved LPLNs, there remains limited evidence defining its safety, oncologic benefit, and role relative to LPLND. METHODS: A systematic search of MEDLINE, EMBASE, ClinicalTrials.gov, and Cochrane databases was conducted following PRISMA guidelines. Studies were included if they reported outcomes of radiation dose escalation specifically targeting radiologically suspicious LPLNs in the context of nCRT. RESULTS: Ten retrospective cohort studies encompassing 482 radiation boosted patients were included. Boost doses ranged from 35.0 to 60.2 Gy. Rates of Grade 2-3 toxicity ranged from 28.0% to 39.3% across individual studies, with only one study reporting a single Grade 4 adverse event. Across individual studies, reported nodal response rates ranged from 62.3% to 100%. Comparative studies suggest that radiation boost may improve local control and reduce LPLN recurrence. CONCLUSION: Current retrospective evidence suggests that radiation dose escalation to involved LPLNs is a promising treatment strategy; however, the available data are limited by retrospective study designs and substantial clinical heterogeneity. Given the absence of prospective evidence and lack of consensus in current guidelines, an important evidence gap remains. Well-designed prospective trials are warranted to define the role of LPLN boost relative to LPLND.

Humans

A multi-scale fusion model based on multi-phase contrast-enhanced CT for predicting pancreatic cancer resectability.

Purpose.Develop a multi-scale fusion model (MSFM) based on multi-phase contrast-enhanced computed tomography (CECT) to predict pancreatic cancer (PC) resectability, thereby assisting expert decision-making.Methods.This retrospective study enrolled 280 patients with PC from four institutions, which were randomly divided into a training cohort (202 patients) and an independent test cohort (78 patients). Three-phase CECT images (arterial, venous, and delayed phases) were used for modeling. The MSFM comprises two sub-networks: (1) a multi-phase fusion network for extracting cross-phase shared fusion features, (2) a phase-specific branch network for capturing phase-specific features; and a post-fusion strategy to generate the final predictive score by integrating the shared fusion features and three groups of phase-specific features. Additionally, a human-machine fusion deep learning model (HMfDL) was constructed by fusing the predictive score of the MSFM with expert assessments.Results.In the independent test, the MSFM achieved an AUC (area under the receiver operating characteristic curve) of 0.8385 (95% CI: 0.7521-0.9249), accuracy of 84.62%, sensitivity of 72.00%, and specificity of 90.57%. This performance outperformed single-phase models (AUC range: 0.7638-0.7781), two-phase models (AUC range: 0.7826-0.7864), and ten states-of-the-art classifiers (AUC range: 0.7404-0.7796). The HMfDL further improved the performance, reaching an AUC of 0.8626 (95% CI: 0.7853-0.9400), accuracy of 91.03%, sensitivity of 80.00%, and specificity of 96.23%. Notably, the HMfDL corrected 58.82% of misdiagnosis made by experts.Conclusions. The MSFM effectively fuses multi-phase CECT to enable highly accurate predictions of PC resectability, and provides valuable support for expert decision-making through HMfDL.

Humans

Comparison of black carbon measurements using filter-specific reference transmittance to those using lab blanks or an average of unloaded filters.

Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). We analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial to assess the influence that different methods of I0 estimations have on eBC measures. We compared eBC measurements using filter-specific I0 values (Method 1) to those using three other methods of I0 estimation: the lab blank scan from a given session (Method 2), the average of all pre-sample filter scans (Method 3), and the average of all lab blank filter scans (Method 4). We assessed the agreement between Method 1 and the alternative methods using Bland-Altman analysis. We also assessed the relationship between Method 1 and the alternative methods across the complete measurement range and after stratifying exposure data into quartiles according to Method 1 eBC exposures. The mean (SD) personal eBC exposure for Method 1 was 7.8 μg/m3 (5.9), and exposures ranged from 1.3 to 46.8 μg/m3. Compared to Method 1, eBC using Methods 2, 3, and 4 were higher by 0.7 μg/m3, 0.1 μg/m3, and 0.7 μg/m3, respectively. The performances of linear regression models between Method 1 and all other methods were moderate to strong (R2 range: 0.42-0.93) in the second, third, and fourth quartiles; however, the models in the first quartile (eBC range: 1.3-2.9 μg/m3) performed poorly (R2 = 0.25-0.26), with error approximately 25% of the mean. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.Implications: Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). To assess the influence that different methods of I0 estimations have on eBC measures, we analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.

Soot

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20 ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r = 0.926). PFOS was the only compound detected at concentrations ≥0.2 ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50 ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Morphology-engineered NiFe@C nanocages boosting electrochemical quantification of ractopamine in meat samples.

It is essential to acquire efficient electrocatalysts to develop ractopamine (RAC) electrochemical sensors. Herein, we report the synthesis of a series of carbon coated NiFe alloy nanostructures (e.g., NiFe@C nanoparticles, nanocubes and nanocages) using NiFe Prussian blue analogue (PBA) as the precursor. The NiFe@C nanocages exhibited the best electrocatalytic performance for RAC sensing. This is attributed to the embedded NiFe alloy nanoparticles that provide abundant active sites, and the unique nanocage structure facilitates electron transfer pathways while offering a high specific surface area. The resulting sensor achieves a low detection limit (LOD) of 54 nM (S/N = 3) within a linear range of 0.2-12 μM. Moreover, the sensor demonstrates good reproducibility, stability, and excellent long-term stability. Practical applicability was confirmed in meat samples, yielding satisfactory recovery rates ranging from 98% to 108%. A feasible strategy was introduced herein for rational design of metal@carbon electrocatalysts.

Phenethylamines

Posterior Segment Risk Factors for Penetrating Keratoplasty Failure.

PURPOSE: To analyze the relationship between intraoperative and postpenetrating keratoplasty (PK) posterior segment variables and PK graft survival. DESIGN: Retrospective clinical cohort study. SUBJECTS: Patients undergoing PK between May 1, 2007 and September 1, 2018 at a single tertiary center. METHODS: Chart review for PKs performed was conducted, and the first PK completed at the institution for each patient was included for analysis. Data collected included demographics, medical and ocular history, preoperative and intraoperative findings, and intraoperative and postoperative posterior segment factors (pars plana vitrectomy [PPV], endolaser, retinal detachment [RD], and vitreous hemorrhage [VH]). After univariable analysis, variables were selected for multivariable Cox regression analysis. MAIN OUTCOME MEASURE: Graft failure, defined as irreversible and visually significant corneal edema, haze, or scarring. RESULTS: Eight hundred and thirty-five eyes of 835 patients were included. Mean age was 57.1 ± 22.0 (range: 0-100) years, and mean time from PK to final follow-up or graft failure was 3.2 ± 2.9 (range: 0.01-16.1) years. Graft failure occurred in 35.0% of cases with a mean onset of 1.9 ± 2.0 (range: 0.04-11.4) years after PK. After multivariable analysis, 9 variables had significant associations with failure. Two posterior segment variables were significant: intraoperative VH at the time of PK (hazard ratio [HR] 6.6, 95% confidence interval [CI] 1.6-27.7, P = .010) and silicone oil (SO) tamponade after the PK (HR 3.2, 95% CI 1.4-7.4, P = .007). CONCLUSIONS: Graft failure is a serious complication of PK. VH at the time of the PK and SO tamponade after the PK were associated with graft failure. In complex eyes that are undergoing PK grafts and that may also require posterior segment interventions, these findings may guide patient counseling and discussion of graft prognosis.

Humans

Biologic-biologic and biologic-JAK inhibitor combination therapy in refractory systemic autoinflammatory diseases.

OBJECTIVES: Systemic autoinflammatory diseases (SAIDs) arise from genetic defects in innate immunity, leading to dysregulated activation of inflammatory pathways, including interleukin (IL)-1, IL-6, TNF, and JAK/STAT. Clinical manifestations range from recurrent fever to severe complications such as encephalitis and AA amyloidosis. Management aims to control inflammation using immunosuppressive agents and targeted monotherapies (biologics or JAK inhibitors). Advanced combination therapy (ACT), defined as the use of biologics and/or JAK inhibitors in combination, has emerged as a strategy for refractory disease. METHODS: In this observational retrospective longitudinal cohort study, patients with SAIDs treated with ACT were included. Demographic, clinical, treatment, and safety data were collected. Treatment response was assessed using a composite outcome incorporating corticosteroid dose, C-reactive protein (CRP), and clinical improvement and categorized as non-response, partial response, or complete response. RESULTS: Thirty-eight patients (median age 30 years [range 4-76]) were included. The most common indications for ACT were pyogenic arthritis, pyoderma gangrenosum and acne (PAPA), mevalonate kinase deficiency (MKD), and undifferentiated SAIDs. Most patients had disease-related complications and were dependent on glucocorticoids and/or opioids to control inflammation and pain, respectively. Following multiple ACT trials, complete response was observed in 21 patients (55.3%), partial response in 12 (31.6%), and no response in 5 (13.1%). Overall, 65 ACT regimens were administered, most commonly combining IL-1 and TNF inhibitors. Thirty-nine regimens were discontinued because of lack of efficacy, secondary loss of response, or adverse events. At the final follow-up, 26 patients (68%) remained on ACT, with a median treatment duration of 60 months (range, 11-186). CONCLUSIONS: ACT offers significant clinical benefits for patients with difficult-to-treat SAIDs, though challenges such as secondary loss of efficacy and infection risks remain.

Humans

Cochlear size variation in a large-scale international multicentre cohort.

AIM: This study aims to (1) review the literature on cochlear size, measured by the A-value, to assess reported variation across studies, and (2) consolidate cochlear parameters-specifically basal turn diameter (A-value) and width (B-value)-measured using the standardized DICOM viewer OTOPLAN®, and compare these with published data. METHODS: A scoping literature review was conducted using the search term "diameter of cochlear basal turn" to identify studies reporting A-value measurements. To complement this, cochlear measurements obtained with OTOPLAN® were collected from clinical collaborators across multiple international centres. The ratio of B- to A-values, which defines the cochlear basal turn shape, was calculated as previously described by Khurayzi et al. (2021). RESULTS: The literature review identified 38 studies comprising 5,206 A-value measurements (average: 9.08 mm; range: 8.01-10.03 mm). Additionally, 5,580 OTOPLAN® measurements were collected from 43 clinics across 25 countries (mean: 9.07 mm; range: 6.67-11.45 mm). Overall, 68.7% of cochleae exhibited an elliptical basal turn shape. CONCLUSION: Using a large, international multicentre dataset and a standardized measurement tool, this study demonstrates substantial variation in cochlear size and shape across clinical cohorts from different regions. The mean A-value (9.07 mm) is consistent with previously published literature, while the wider observed range highlights greater anatomical variability within a multicentre clinical population than previously reported. The majority of cochleae demonstrate an elliptical basal turn configuration.

Humans

Predicting ACL injury risk in athletes: A systematic review of machine learning-based models.

BACKGROUND: Early ACL injury risk identification in athletes is essential. This systematic review examines machine learning (ML) models for predicting ACL injuries, evaluating their methodological quality, performance, and reliability. METHOD: A comprehensive electronic search was conducted across PubMed, Scopus, Web of Science, and IEEE Xplore databases, supplemented by Google Scholar for grey literature, covering articles published between January 1, 2015, and August 30, 2025. Eligible studies were appraised using the Prediction Model Study Risk of Bias Assessment Tool (PROBAST) for methodological quality and risk of bias, and the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD) guidelines for quality of evidence. RESULTS: Ten studies were included. PROBAST showed eight studies had moderate risk of bias and two low risk. TRIPOD found only two studies met quality criteria. ML models included logistic regression (n = 5), support vector machines (n = 4), k-nearest neighbor (n = 3), decision trees (n = 3), random forests (n = 5), neural networks (n = 2), linear discriminant analysis (n = 1), and pre-trained CNNs (n = 1). AUC ranged from 0.63 to 0.98. Accuracy (reported in six studies) ranged from 26% to 95%; however, these values should be interpreted with caution due to the absence of confidence intervals, lack of class imbalance handling, and limited external validation across studies. Tree-based ensemble methods such as random forest achieved competitive accuracy (74-86%), while SVM, a non-ensemble classifier, reported accuracy ranging from 71% to 95%; however, the highest values were obtained in studies with notably small sample sizes (n = 12 to n = 39), raising concerns about overfitting and generalizability. CONCLUSION: Current ML algorithms show promise for identifying athletes at high ACL injury risk and detecting relevant risk factors. Although study quality was generally satisfactory, future research should prioritize external validation and model interpretability to support clinical translation.

Humans

Peptide molecular lock-engineered nanobodies enable an oriented dual-modal immunoassay for reliable detection of Cronobacter sakazakii.

Conventional nanobody ELISAs for trace Cronobacter sakazakii in powdered infant formula suffer from random orientation and low signal output. We developed an oriented dual-modal immunoassay that combines site-specific biotinylation via a C-terminal AviTag and a peptide molecular lock, enabling controlled surface orientation while preserving nanobody structural integrity. This strategy was further integrated with phage-displayed nanobodies for multivalent amplification and both fluorescent and colorimetric readouts. The assay exhibited a broad linear range of 103-106 CFU/mL, with limits of detection (LODs) of 6.70 × 102 CFU/mL for fluorescence and 1.55 × 103 CFU/mL for colorimetry, showing improved sensitivity compared with the conventional passive adsorption-based Nb-ELISA evaluated in this study. XGBoost-based multimodal fusion improved quantitative accuracy, and SHAP analysis elucidated modality contributions. In spiked powdered infant formula samples, recoveries ranged from 92.1% to 118% with coefficients of variation below 5.98%, confirming acceptable matrix tolerance and analytical reliability.

Cronobacter sakazakii

A MIL-88@Ru-based molecularly imprinted electrochemiluminescence sensor for highly selective and sensitive detection of enrofloxacin residues in animal-derived foods.

Using a metal-organic framework (MOF) - supported Ru(bpy)32+ (MIL-88@Ru) composite luminescent material, this study innovatively adopted electropolymerization to fabricate a molecularly imprinted polymer-based electrochemiluminescent (MIP-ECL) sensor for enrofloxacin (ENR) detection in animal-derived foods. Systematic investigation of the ECL luminescence and ENR's quenching mechanism confirmed that the sensor integrates ECL's high sensitivity and MIP's high specificity, enabling rapid and accurate recognition of ENR. Experimental results show a good linear response in the range of 1 nmol/L-20 μmol/L (R2 = 0.99), a limit of detection (LOD) as low as 0.28 nmol/L, as well as excellent selectivity and stability. Recoveries of ENR in all investigated matrices ranged from 97.7% to 106.4%, confirming the reliability of the established method. This ECL-MIP coupling strategy provides a new technical approach and application references for the efficient detection of trace pollutants in food safety and environmental monitoring fields.

Enrofloxacin

Closed-loop vasopressor systems for hemodynamic control in perioperative and critical care settings: a systematic review and meta-analysis.

Maintaining mean arterial pressure (MAP) within a predefined target is central to haemodynamic management in surgical and critically ill adults receiving vasopressors. Closed-loop vasopressor (CLV) systems automate titration to optimise blood pressure control, but their clinical effectiveness remains uncertain. We performed a systematic review and meta-analysis comparing CLV with manual titration. This PRISMA 2020-compliant review was prospectively registered in PROSPERO (CRD420250655697). MEDLINE, Embase, Scopus, Web of Science, CENTRAL, and the Cochrane Library were searched (January 2000-June 2025). Randomised controlled trials enrolling adults receiving vasopressors in perioperative or intensive care settings were included. Primary outcomes were time within the MAP target range and time spent in hypotension or hypertension. Risk of bias was assessed using RoB 2.0 and certainty of evidence using GRADE. Random- or fixed-effects models were selected according to heterogeneity. Six randomized controlled trials (215 patients) were included in the systematic review, whereas five perioperative trials contributed to the meta-analysis of haemodynamic control outcomes, and one ICU-based study was summarized narratively because it did not report comparable MAP control endpoints. CLV increased time within the MAP target range (mean difference [MD] 33.94%, 95% CI 20.41-47.46; I2 = 77%) and reduced time in hypotension (MD - 18.24%, 95% CI - 28.95 to - 7.53; I2 = 73%). There was no significant difference in time in hypertension, cumulative norepinephrine dose, or major/minor adverse events. ICU length of stay was not pooled because of clinical and methodological heterogeneity. Certainty of evidence ranged from low to high (moderate for haemodynamic control outcomes). CLV systems improved haemodynamic control, primarily in perioperative settings, but heterogeneity and small samples limit confidence in effect size and generalisability. Evidence in critically ill populations remains limited, and larger trials are needed to determine whether improvements in these physiological surrogate endpoints translate into meaningful patient-centred outcomes.

Humans

Beyond species trees: pervasive gene flow limits phylogenomic resolution in the diversification of Juniperus from the Qinghai-Tibet Plateau.

Understanding how lineages diversify despite persistent ancestral polymorphism and recurrent gene flow remains a central challenge in evolutionary biology. Juniperus distributed across the Qinghai-Tibet Plateau provide an ideal system for addressing this question because repeated geological uplift and climatic oscillations have likely promoted cycles of lineage divergence, range shifts, and secondary contact. Here, we combined approximately 1.08 million genome-wide SNPs from 164 individuals representing thirteen Juniperus lineages with phylogenomic datasets comprising 3,381 nuclear single-copy genes and nearly complete plastomes. We detected extensive phylogenomic discordance and cytonuclear incongruence across genomic datasets. Topology weighting, coalescent simulations, quartet-based tests, and analyses of gene flow and reticulation collectively support the interpretation that these patterns were shaped by the combined effects of prolonged incomplete lineage sorting and gene flow during lineage diversification. Ecological niche analyses further provide a spatial and climatic context in which environmentally similar lineages may have had greater opportunities for secondary contact during historical range shifts. Collectively, our results reveal that the evolutionary history of Qinghai-Tibet Plateau Juniperus is characterized by reticulate diversification rather than strictly bifurcating evolution, and demonstrate how genome-wide discordance can provide biological insights into the evolutionary processes underlying lineage diversification.

Gene Flow

Impact of real-time respiratory function monitoring on neonatal mask ventilation training: a multicentre simulation-based crossover study.

OBJECTIVE: To evaluate whether visibility of respiratory function monitor (RFM) feedback improves mask ventilation performance and influences subsequent ventilation performance during neonatal resuscitation training. DESIGN: multicentre randomised crossover simulation study. PARTICIPANTS: Healthcare professionals involved in neonatal resuscitation training across participating centres. INTERVENTION: Participants performed positive pressure ventilation (PPV) on both term and premature manikins under two conditions: with visible RFM feedback and with the display masked. The order of feedback visibility was randomised. Each participant completed ventilation assessments in both conditions. MAIN OUTCOME MEASURES: Primary outcomes were expired tidal volume (Vte) and mask leak (%). The proportion of breaths within the target Vte range (4-8 mL/kg) was calculated as a performance indicator. Secondary outcomes included variability in Vte and mask leak to assess ventilation stability between conditions. RESULTS: Visible RFM feedback was associated with lower mask leak and improved ventilation stability in the preterm manikin and with tidal volumes entering the target range in the term manikin. Participants initially ventilated with visible feedback maintained performance after feedback removal, suggesting a carry-over learning effect. CONCLUSION: In this multicentre crossover simulation study, visible RFM feedback was associated with changes in mask ventilation performance and evidence of a carry-over learning effect following feedback removal. Real-time visibility of respiratory parameters may strengthen neonatal resuscitation training.

Humans

Ambrosia beetle invasions are structured by inbreeding, intraspecific hybridisation, and bridgeheads.

When invasive populations establish in regions far from their origin, they may accumulate deleterious mutations that limit population viability and later expansion. Invasions stemming from such bridgehead populations may experience further sequential bottlenecks. However, deleterious mutations can be masked or eliminated when populations outbreed with other lineages. Here, we analyse global invasions of a species complex of persistently inbreeding ambrosia beetles, using genomic data (N=247) from invasive populations in Africa, North America and Australia, and from native populations in Asia. We mostly focus on one species of this complex (Euwallacea fornicatus) which poses a severe threat to tree species worldwide and is rapidly expanding its global range. We uncover a single lineage of this species across California, South Africa, and Western Australia, involving an invasive bridgehead and containing almost no nuclear genetic variation. In South Africa we identify a second lineage that has repeatedly hybridised with the first lineage. Genetic patterns in the native range indicate that such opportunistic outbreeding may be common. Despite lacking nuclear variation, the first lineage contained two CO1 haplotypes that were also observed in every hybrid lineage, pointing to heteroplasmy and possible hybrid origins of this lineage. Native populations had fewer missense mutations than invasive populations, indicating that opportunistic outbreeding may help purge fixed deleterious mutations when local lineage diversity is high. These findings highlight the importance of outbreeding even when inbreeding is common, and they demonstrate the biosecurity threat posed by subsequent gene flow into invasive populations.

Journal Article