Search PubMedSearch

PubMed · 42480071

Comparison of black carbon measurements using filter-specific reference transmittance to those using lab blanks or an average of unloaded filters.

Abstract

Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). We analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial to assess the influence that different methods of I0 estimations have on eBC measures. We compared eBC measurements using filter-specific I0 values (Method 1) to those using three other methods of I0 estimation: the lab blank scan from a given session (Method 2), the average of all pre-sample filter scans (Method 3), and the average of all lab blank filter scans (Method 4). We assessed the agreement between Method 1 and the alternative methods using Bland-Altman analysis. We also assessed the relationship between Method 1 and the alternative methods across the complete measurement range and after stratifying exposure data into quartiles according to Method 1 eBC exposures. The mean (SD) personal eBC exposure for Method 1 was 7.8 μg/m3 (5.9), and exposures ranged from 1.3 to 46.8 μg/m3. Compared to Method 1, eBC using Methods 2, 3, and 4 were higher by 0.7 μg/m3, 0.1 μg/m3, and 0.7 μg/m3, respectively. The performances of linear regression models between Method 1 and all other methods were moderate to strong (R2 range: 0.42-0.93) in the second, third, and fourth quartiles; however, the models in the first quartile (eBC range: 1.3-2.9 μg/m3) performed poorly (R2 = 0.25-0.26), with error approximately 25% of the mean. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.Implications: Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). To assess the influence that different methods of I0 estimations have on eBC measures, we analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.

Explore related subjects

Keep this discovery

BibTeXRIS

Devan Campbell, Michael Johnson, Ricardo Piedrahita, Ajay Pillarisetti, Lance A Waller, Katherine A Kearns, Jacob Kremer, Erick Mollinedo, Jeremy A Sarnat, Maggie L Clark, Lindsay J Underhill, John P McCracken, Anaite Diaz-Artiga, Lisa M Thompson, Ghislaine Rosa, Miles Kirby, Kalpana Balakrishnan, Sankar Sambandam, Krishnendu Mukhopadhyay, Laura Nicolaou, William Checkley, Jennifer L Peel, Thomas F Clasen, Luke P Naeher. 2026-07-21. Comparison of black carbon measurements using filter-specific reference transmittance to those using lab blanks or an average of unloaded filters.. https://doi.org/10.1080/10962247.2026.2626414

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Marine air promotes structural compaction and coating growth of soot aerosols after long-range transport from East Asia.

Soot aerosol, a key global warming contributor, undergoes morphological and chemical transformations during atmospheric transport, particularly in humidified marine environments. This study investigates morphology, mixing state, and aging mechanisms of soot particles collected in the Bohai Sea and Yellow Sea. Transmission electron microscopy analyses reveal that coated soot particles dominate the marine atmosphere, accounting for over 98 % of soot-containing particles, with a mean mixing state index (χ) of 0.83. The fractal dimension (Df) of soot particles is 1.84 ± 0.05 in the Northern Yellow Sea, 1.90 ± 0.08 in the Bohai Sea, and 1.96 ± 0.07 in the Southern Yellow Sea, indicating structural compaction during long-range transport. Correspondingly, the average Dp/Dcore ratios (particle to core size ratio) are 5.3 in the Bohai Sea, 4.2 in the Northern Yellow Sea, and 3.9 in the Southern Yellow Sea. Notably, those ratios are higher in marine environments compared to those observed during continental regional transport from northern to southern China (3.54), suggesting enhanced coating growth in humid marine air. The results highlight the important role of marine atmospheres in accelerating soot aging, which in turn leads to significantly stronger light absorption compared to soot in continental air. Our results highlight the necessity of incorporating compact morphologies, uniform mixing states, and thick coatings into optical models for accurate radiative forcing simulations.

Aerosols

Diurnal differences in the effects of heat exposure on renal function: A randomized controlled crossover trial.

High temperature is a major risk factor for kidney injury, and population exposure to nighttime heat is increasing as the climate warms. However, whether renal responses to heat exposure differ between daytime and nighttime remains unclear. Forty-one healthy adults participated in a randomized crossover experiment conducted in a controlled laboratory setting. Participants were exposed to heat (32°C during daytime; 30°C during nighttime) and thermoneutral conditions (26°C) for 8 h. Blood and urine samples were collected before and after each exposure to examine various renal biomarkers reflecting glomerular filtration function, tubular injury, and early kidney stress. Heat exposure affected both blood and urinary biomarkers of kidney function, with notable diurnal differences in renal responses. Daytime heat exposure primarily affected blood markers of glomerular filtration, increasing creatinine by 7.67% (95% CI: 4.73%-10.61%) and cystatin C by 3.05% (95% CI: 0.17%-5.93%), while reducing estimated glomerular filtration rate by 0.05% (95% CI: 0.02%-0.08%). In contrast, nighttime heat exposure predominantly elevated urinary biomarkers of early kidney stress, including insulin-like growth factor-binding protein 7 (58.40%, 95% CI: 27.66%-89.14%), kidney injury molecule-1 (47.25%, 95% CI: 18.91%-75.59%), and tissue inhibitor of metalloproteinases-2 (51.88%, 95% CI: 22.26%-81.51%). Moreover, increases in insulin-like growth factor-binding protein 7 were significantly greater at night than during the day. Sleep-related parameters, including sleep quality, duration, and heart rate variability, partially mediated nighttime heat effects on renal responses. These results indicated that heat exposure induced different diurnal patterns in renal responses.

Humans

Genetic overlap between estimated glomerular filtration rate and cardiovascular disease identifies potential targets for cardiorenal syndrome.

Heart and kidney diseases frequently coexist, but the genetic basis of this relationship remains unclear. We analyzed genetic data from large-scale studies to investigate how kidney function (estimated glomerular filtration rate, eGFR) and six common cardiovascular diseases share genetic risk factors. Using MiXeR method, and conjunctional false discovery rate (conjFDR) to identify overlapping genetic regions, we found 478 shared genomic loci between eGFR and cardiovascular diseases. These shared genes are involved in tissue development and structure. We also identified 29 genes that could be targeted by existing medications approved by the US Food and Drug Administration, such as PRKAG2, PDE1A, and IGF1R. Among these, genetically predicted higher level of IGF1R expression is associated with a higher eGFR, which reflects good kidney function and is protective against cardiorenal diseases, such as atrial fibrillation, and myocardial infarction. These findings reveal genetic overlap between kidney function and cardiovascular diseases, highlighting potential targets for understanding and treating cardiorenal syndrome.

Humans