Search PubMedSearch

SEARCH · Search PubMed

Results for “computational modelling”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

893 records · Page 3Linked to original sources

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2×2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I²=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

Multiscale Modeling Primer: Focus on Chromatin and Epigenetics.

A central challenge in modern biology is to understand how molecular interactions produce cellular and organismal functions across vast spatiotemporal scales. Nowhere is this challenge more apparent than in the study of chromatin, where meters of DNA compact into a micron-sized nucleus. How this polymer folds is a dynamic process, regulated by epigenetic modifications-chemical changes to DNA and histones that involve only a handful of atoms. These small changes cooperate to produce emergent, higher-order structures that define cellular identity and function. To explain this system, we must integrate static, high-resolution snapshots from techniques like cryo-EM with dynamic, lower-resolution data from microscopy and genomics. Multiscale computational models are essential tools that bridge these experimental gaps and reveal the mechanisms of emergent behavior. However, the communication divide between experimental biologists and quantitative modelers often hampers progress. This primer addresses that gap. It first introduces the fundamental biology of chromatin and epigenetics at an introductory level for non-biologists audiences. We then survey the landscape of computational approaches, from atomistic to systems-level models, and connect them to the experimental data that inform and validate them at an introductory level for non-computationalists. We argue that the next frontier will require us to build integrative models that can predict how molecular perturbations mechanistically alter cellular phenotypes, which will open a new era of chromatin-targeted therapeutics.

Chromatin Dynamics

Privacy, security, and reliability risks of artificial intelligence in healthcare: a systematic review of empirical evidence.

BACKGROUND: Artificial intelligence (AI) is increasingly integrated into healthcare information systems, supporting clinical decision-making, imaging analysis, and predictive modeling. While these applications offer operational and clinical benefits, they also introduce emerging risks to patient privacy, data security, and system reliability. OBJECTIVE: To systematically review empirical evidence on privacy breaches, security vulnerabilities, and misuse associated with AI applications in healthcare settings. METHODS: PubMed, Embase, Web of Science, Scopus, IEEE Xplore, and ACM Digital Library were searched for empirical studies published between January 2015 and November 2025 that evaluated AI use or misuse in clinical diagnosis, treatment, or decision-making. Two reviewers independently screened studies and extracted data using a standardized form. Findings were synthesized narratively due to heterogeneity in study designs, AI methods, and reported outcomes. RESULTS: Of 7,285 records identified through database searches and 205 through citation screening, 22 empirical studies met the inclusion criteria, spanning multiple clinical domains and data modalities, predominantly medical imaging applications. Five recurring threat categories were identified: patient re-identification, membership inference, unauthorized access and adversarial exploitation, input manipulation, and misuse or overinterpretation of AI outputs. Across studies, AI models were shown to encode latent biometric signals across diverse data types, limiting the effectiveness of traditional anonymization and synthetic data approaches. Adversarial attacks and input manipulation were also shown to compromise diagnostic performance and system integrity. CONCLUSION: This systematic review provides empirical evidence suggesting that contemporary AI systems in healthcare introduce privacy and security risks that may challenge traditional assumptions about data protection. These findings underscore the need for privacy- and security-by-design approaches and governance frameworks that address risks across the AI lifecycle.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7 × 108 CFU/mL and a low detection limit of 1.66 CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19% ∼ 104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer

A contextual activity score (CAS) for inferring ADAR-associated transcriptional activity across RNA-seq, single-cell, and spatial transcriptomics.

BACKGROUND AND OBJECTIVE: Adenosine-to-inosine RNA editing, catalyzed by Adenosine Deaminases Acting on RNA (ADARs), is a widespread modification involved in neural function, immune regulation, and cancer. The Alu Editing Index (AEI) is the standard metric to estimate ADAR activity but requires raw sequencing reads and is poorly suited for single-cell and spatial transcriptomic data. This study aimed to develop an alternative framework for inferring ADAR-associated transcriptional activity from gene expression data across diverse transcriptomic technologies. METHODS: We developed the Contextual Activity Score (CAS), a framework based on transcriptional signatures from ADAR perturbation experiments. Context-specific signatures were generated for human neurons, mouse neurons, and cancer models to infer ADAR1 and ADAR2 activity. CAS was computed from normalized gene expression matrices using regulon-based enrichment analysis. Performance was evaluated by comparing with the Alu Editing Index across bulk RNA sequencing datasets, simulated sequencing depths, and library preparation protocols. RESULTS: CAS showed strong concordance with the Alu Editing Index across multiple datasets, while remaining robust to reduced sequencing depth and different library protocols. Unlike the Alu Editing Index, CAS can be applied to single-cell and spatial transcriptomic data and enables the independent assessment of ADAR2 activity. In cancer and neuronal contexts, CAS captured biologically meaningful variations in ADAR-associated transcriptional activity at sample, cell-type, and spatial levels. CONCLUSION: CAS provides a scalable approach applicable across multiple RNA-seq protocols for estimating ADAR-associated transcriptional activity using gene expression data. This method, implemented in an open-source R package for broad adoption, expands the ability to study ADAR-associated transcriptional activity across transcriptomic modalities where direct editing quantification is challenging, such as single-cell and spatial transcriptomics.

Adenosine Deaminase

Applications of artificial intelligence in robot-assisted surgery: a systematic review.

To characterize applications of artificial intelligence (AI) in robot-assisted surgery, summarize technical and clinical performance, and assess the quality of the available evidence. PubMed, Web of Science Core Collection, and Scopus were searched for English-language journal articles published from 1 January 2020 through 31 October 2025. Randomized, observational, model-development, validation, and feasibility studies evaluating AI in robot-assisted surgery or closely related image-guided minimally invasive workflows were eligible. Two reviewers independently performed study selection, data extraction, and risk-of-bias assessment. Owing to heterogeneity in surgical procedures, AI tasks, analytical units, validation strategies, and outcomes, findings were synthesized descriptively without statistical pooling. The review was registered in the International Prospective Register of Systematic Reviews (CRD420251175699). Seventeen studies were included: seven clinical prediction or decision-support studies, eight intraoperative recognition, segmentation, or image-guided studies, and two training or workflow studies. Five prediction studies reported area-under-the-curve values of 0.74-0.95. Technical studies reported F1 or Dice scores of 0.525-0.995 and task-specific accuracies of 0.840-0.998. Two randomized studies suggested benefits for personalized suturing feedback and automated camera control, but neither established improved patient outcomes. Only one study had low overall risk of bias; the remaining studies were at high or unclear risk or raised some concerns. AI applications in robot-assisted surgery show promise for prediction, intraoperative perception, training, and workflow support. Evidence primarily demonstrates technical feasibility rather than established clinical effectiveness. Independent multicenter validation and prospective evaluation of patient, educational, and workflow outcomes are required before widespread implementation.

Robotic Surgical Procedures

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

The utility of 18F-fluorodeoxyglucose PET/computed tomography in relapsing polychondritis: a systematic review and meta-analysis.

Relapsing polychondritis is a rare chronic autoimmune inflammation of the cartilage associated with life-threatening respiratory complications. Currently, no clear role of imaging modalities such as 18F-fluorodeoxyglucose (FDG) PET/computed tomography (CT) is defined in the literature. This systematic review and meta-analysis provide current evidence on the PET-positivity rate and utility in relapsing polychondritis. Prospective or retrospective studies with more than five patients of suspected relapsing polychondritis who underwent 18F-FDG PET/CT during their management and reported a PET-positivity rate were included. Low-sample-size studies describing chondritis due to other aetiologies or utilizing PET-based radiopharmaceuticals other than FDG were excluded. A systematic search using relevant keywords was conducted across four databases (PubMed, Embase, Scopus and Web of Science) to include studies up to 25 April 2025. The Joanna Briggs Institute critical appraisal tools were used for risk-of-bias analysis. Data were analysed using the R software package (v4.3.1; 2023). Out of 962 articles, three with a total of 97 patients were included. With a pooled PET-positivity rate of 94% [95% confidence interval (CI): 73-99%, I2 = 0%, P = 0.76] and a pooled baseline SUVmax of 4.0 (95% CI: 3.5-4.6, I2 = 32%, P = 0.23), 18F-FDG PET identified asymptomatic cartilage involvement in more than 25% patients and PET parameters correlated well with inflammatory markers. It had a higher positivity rate for inaccessible sites, such as peripheral airways, and was crucial in treatment monitoring. The pooled PET-positivity rate of 18F-FDG PET in relapsing polychondritis is high but requires prospective large-sample-size studies to explore the diagnostic accuracy and prognostic implications of 18F-FDG PET in relapsing polychondritis.

Polychondritis, Relapsing

Three-Dimensional Fracture Mapping of the Terrible Triad of the Elbow: Morphological Characteristics and Clinical Implications.

BACKGROUND: The morphology of fractures in the terrible triad of the elbow (TTE) is complex, and precise management relies on a profound understanding of this morphology. This study aims to systematically analyze, for the first time, the distribution and morphological characteristics of TTE fracture lines using three-dimensional (3D) imaging technology. METHODS: Clinical data and thin-slice CT scans of 112 patients with TTE from January 2021 to December 2024 were retrospectively included. 3D fracture models were reconstructed using Mimics software. Virtual reduction and standardized alignment were performed using 3-matic software. Fracture lines were mapped onto standard ulnar and radial templates, and 3D fracture heat maps were generated using the E-3D software to demonstrate the high-frequency distribution zones of the fracture lines visually. Statistical analysis was performed using SPSS software (version 21.0, IBM Corp., Armonk, NY, USA). Continuous variables were compared using one-way analysis of variance (ANOVA), and categorical variables were compared using the chi-square test (&#x3c7;2 test). A two-tailed p&#x2009;<&#x2009;0.05 was considered statistically significant. RESULTS: The study revealed distinct patterns in the distribution of TTE fracture lines. In the coronoid process, the fracture "hot zone" presented as an annular high-density band extending from the lateral middle aspect to the tip. In the radial head, an oblique high-density band was observed in the anterolateral quadrant of the articular surface. The radial neck exhibited a circumferential high-density zone, which was most prominent in the anterolateral aspect. Statistical analysis indicated a significant correlation between age and fracture complexity; the proportion of Regan-Morrey type III coronoid fractures and Mason type III radial head fractures was significantly higher in elderly patients (>&#x2009;60&#x2009;years) (p&#x2009;<&#x2009;0.05), suggesting that advanced age is a significant risk factor for complex fractures. CONCLUSION: This study is the first to visually reveal the Collaborative Distribution Patterns of TTE fracture lines using 3D fracture mapping technology. This model provides morphological evidence for understanding the injury mechanism of TTE and offers an anatomical framework that may assist surgeons in individualizing surgical approaches and fixation strategies.

Humans

Baseline Computed Tomography Coronary Angiography and Polygenic Risk Profiles in Adults With Type 2 Diabetes: A Cross-Sectional Analysis From the VOLTAIRE Study.

AIMS: To characterise baseline clinical, anatomical, and genetic cardiovascular risk profiles in participants enrolled in the VOLTAIRE (Evaluation of Polygenic Scores and CT Imaging in Risk Factor Modification in Patients with Type 2 Diabetes) study and examine concordance across these domains. METHODS: This analysis included adults with T2D who completed baseline computed tomography coronary angiography (CTCA) and polygenic risk score (PRS) assessment prior to randomisation in the VOLTAIRE study. Coronary atherosclerosis was evaluated using coronary artery calcium (CAC) score and CTCA-derived stenosis severity. Clinical risk was assessed using the New Zealand Society for the Study of Diabetes 5-year cardiovascular risk calculator. Polygenic risk for coronary artery disease was assessed using a genome-wide PRS and categorised into tertiles. RESULTS: Among 126 participants with T2D (mean age 57.5&#x2009;&#xb1;&#x2009;8.7&#x2009;years; 62.7% male), coronary atherosclerotic burden was highly heterogeneous: 34.9% had CAC&#x2009;=&#x2009;0, whereas 19.8% had CAC &#x2265;&#x2009;400. Moderate-to-severe coronary stenosis (&#x2265;&#x2009;50%) was present in 40.5% of participants overall, including 20.4% of those classified as low clinical risk. PRS distribution was variable (low 37.3%, intermediate 35.7%, high 27.0%). Overlap between anatomical, genetic, and clinical domains&#xa0;was limited, with only 8.7% of participants classified as high risk across all three. CONCLUSIONS: Substantial heterogeneity and limited overlap&#xa0;exist between anatomical, genetic, and clinical cardiovascular risk measures in T2D. These findings support a multimodal approach to risk assessment integrating imaging and genetic profiling. TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov; ID: NCT07091162.

Aged

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19&#x2009;433 patients (mean age, 62 years &#xb1; 14.2 [SD]; 21&#x2009;814 men; 39&#x2009;323 chest CT examinations, 19&#x2009;190 pre-AI, and 20&#x2009;133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20&#x2009;000-22&#x2009;000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. &#xa9; The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.

Humans

Linked-color imaging with computer-aided detection and the proximal adenoma miss rate: a randomized tandem trial.

BACKGROUND AND AIMS: Linked-color imaging (LCI) aids the detection and characterization of lesions. Computer-aided detection (CADe) systems have been introduced to improve lesion detection during colonoscopy. Although several studies have been reported regarding LCI, few have investigated the combination of LCI and CADe. This study aimed to evaluate the efficacy of LCI with CADe colonoscopy compared to conventional white-light colonoscopy. METHODS: A single-center, randomized tandem trial was conducted. Participants referred for first-time colonoscopy after fecal immunochemical test (FIT)-positive, asymptomatic screening, or surveillance colonoscopy were randomized (1:1) to undergo CADe-assisted colonoscopy of LCI or white-light imaging (WLI) in the right side of the colon. The primary outcome was adenoma miss rate (AMR) in the right side of the colon. Secondary outcomes included polyp miss rate (PMR), diminutive adenoma miss rate (dAMR), sessile serrated lesion miss rate (SSLMR), advanced adenoma miss rate, advanced neoplasia miss rate, flat-type lesion miss rate (FMR), and the differences in miss rates based on expertise. RESULTS: Among 232 randomized participants, 209 were analyzed (LCI/CADe: 102; WLI: 107). AMR (WLI: 39% vs LCI/CADe: 20%; P = .001), PMR (42% vs 18%; P < .001), and dAMR (42% vs 21%; P = .003) were significantly lower in the LCI/CADe arm, particularly among experts. SSLMR (46% vs 0%), advanced AMR (30% vs 0%), advanced neoplasia miss rate (25% vs 0%), and FMR (27% vs 5.6%) were lower in LCI/CADe, although without statistical significance. CONCLUSIONS: Compared to conventional colonoscopy, LCI with CADe colonoscopy resulted in a statistically significant decrease, especially in AMR. (UMIN 000050685).

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

Bioactive peptides for meat quality and preservation: Integrating peptidomics and computational screening.

Bioactive peptides generated from meat proteins, fermented meat products, and slaughter by-products have attracted increasing attention as functional molecules for improving meat quality and preservation. In meat systems, peptides can be produced through endogenous postmortem proteolysis, microbial fermentation, gastrointestinal digestion, or controlled enzymatic hydrolysis of underutilized animal by-products. These peptides are closely associated with key meat science endpoints, including postmortem tenderization, oxidative stability, color retention, flavor development, microbial inhibition, and the valorization of processing by-products. However, although high-resolution peptidomics has greatly expanded the identification of meat-derived peptide sequences, their translation into practical meat applications remains limited by matrix interactions, processing stability, sensory constraints, safety concerns, and insufficient validation in real meat systems. This review synthesizes recent advances in meat-related peptidomics and computational screening, including sequence-based prediction, machine learning, molecular docking, molecular dynamics, stability assessment, and safety-oriented filtering. Particular attention is given to how these approaches can prioritize peptides with antioxidant, antimicrobial, flavor-modulating, and preservation-related functions under meat-specific technological constraints. By integrating peptide generation pathways, mass spectrometry-based identification, in silico prioritization, and meat quality endpoints, this review proposes a stage-gated framework for translating meat-derived bioactive peptides from discovery to application. Future research should strengthen matrix-specific validation, standardized peptidomic reporting, and safety assessment to support the use of bioactive peptides in meat quality improvement, clean-label preservation, and circular utilization of meat industry by-products.

Animals

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I&#xb2;=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I&#xb2;=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50&#xa0;min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8&#xa0;min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Humans