Search PubMedSearch

SEARCH · Search PubMed

Results for “Psychomotor Performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

730 records · Page 3Linked to original sources

Influence of microplastics on microalgal performance during wastewater polishing.

Microplastics (MPs) are emerging contaminants that are increasingly accumulating in aquatic ecosystems due to excessive anthropogenic activity and insufficient mitigation strategies, posing serious environmental and public health risks. Their impact on wastewater (WW) treatment processes remains poorly understood. This study evaluated the effects of five MPs commonly found in WW - polypropylene, polystyrene, polyamide, low-density polyethylene, and high-density polyethylene - on the physiology and bioremediation performance of the microalga Chlorella vulgaris in synthetic WW (SWW). Metabolic responses were assessed via esterase activity and intracellular reactive oxygen species (ROS), while nitrogen (N), phosphorus (P), and glucose removal were monitored to evaluate bioremediation efficiency. MPs inhibited esterase activity and elevated ROS levels, indicating oxidative stress. Nevertheless, C. vulgaris maintained a high bioremediation capacity (> 75 % N, > 60 % P, and > 70 % for glucose). Environmental conditions modulated microalga response to MPs exposure. Under N-limited conditions, C. vulgaris exhibited enhanced nutrient uptake and biomass production, but a 12 h/12 h light/dark photoperiod reduced N removal but stimulated glucose consumption via heterotrophic metabolism. In contrast, C-limited conditions exacerbated oxidative stress and compromised nutrient removal, resulting in residual concentrations exceeding legal limits. These findings highlight that environmental factors can either mitigate or exacerbate the physiological stress induced by MPs, ultimately affecting WW polishing. This work provides a comprehensive insight into the cellular and metabolic effects of MPs on microalgae and supports C. vulgaris as a resilient and sustainable approach for nutrient and carbon removal in MP-contaminated WW systems.

Microalgae

Prenatal exposure to indoor PM2.5 and children's cognitive performance at 4 years of age: an observational analysis from the UGAAR randomized controlled trial.

Outdoor fine particulate matter (PM2.5) concentrations during pregnancy are linked to reduced cognitive performance in children. We previously reported that portable HEPA filter air cleaners use during pregnancy improved children's mean full-scale IQ (FSIQ), but no previous studies have evaluated the relationship between indoor PM2.5 during pregnancy and FSIQ in childhood. We conducted an observational analysis using data from the Ulaanbaatar Gestation and Air Pollution Research (UGAAR) randomized controlled trial. Using a previously developed model of weekly indoor PM2.5 concentrations, we estimated the average concentrations in participants' homes over the full pregnancy and in each trimester. When the children were four years old, we measured FSIQ using the Wechsler Preschool and Primary Scale of Intelligence (WPPSI-IV). We used multiple linear regression to assess the adjusted relationships between interquartile range (IQR) contrasts in indoor PM2.5 during pregnancy and FSIQ among 475 mother-child dyads. An 8.8 μg/m3 increase in indoor PM2.5 concentration over the full pregnancy was associated with a reduction of 1.4 points (95% CI: -3.4, 0.6) in mean FSIQ. The strongest association between PM2.5 concentrations and FSIQ was in the first trimester, when a 19.1 μg/m3 contrast was associated with a 2.8-point reduction (95% CI: -5.7, 0.2) in mean FSIQ. Indoor PM2.5, particularly during early pregnancy, may impair brain development, leading to lower mean FSIQ scores in four-year old children. These results, combined with our previous analysis of HEPA filter air cleaners, indicate that reducing PM2.5 exposure during pregnancy has beneficial effects on children's cognitive performance.

Humans

Natural deep eutectic solvent in situ formation-based extraction method coupled to high-performance anion-exchange chromatography with pulsed amperometric detection for multiclass carbohydrates in hot pot bases.

A novel method was developed for the simultaneous extraction of fourteen multiclass carbohydrates from high-fat foods via the in situ formation of deep eutectic adducts from analytes and acetate ions. Different natural deep eutectic solvents (NADESs) composed of fructose and organic acids were tested as extraction solvents. A model NADES formulated with sodium acetate and fructose was characterized using Fourier transform infrared (FTIR) spectroscopy and hydrogen nuclear magnetic resonance (1H-NMR) spectroscopy. The critical extraction parameters were systematically optimized using multi-response surface methodology (MRSM) with a central composite design (CCD). The extract was analyzed using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) using a sodium hydroxide-sodium acetate eluent, which did not require organic solvents. This approach exhibited good linearity over the concentration range of 0.02-10 mg L-1, with correlation coefficients (r) ranging from 0.9994 to 0.9999. The limits of detection and quantification were in the ranges of 0.06-0.42 mg kg-1 and 0.19-1.3 mg kg-1, respectively, which were significantly lower than those of liquid chromatography (LC). The protocol was successfully applied to the determination of fourteen carbohydrates in forty-five hotpot seasoning samples. The recoveries ranged from 86.3% to 104.1%, with relative standard deviations (RSDs) of 0.9-7.1%. By integrating multiple techniques, this strategy simplifies operations, shortens extraction time, and achieves baseline separation of three carbohydrate classes that exhibit poor resolution using a conventional LC method. This study describes an efficient procedure for the simultaneous determination of multiple trace-level carbohydrates in complex samples using HPAEC-PAD.

Journal Article

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Engineering copper ferrite (CuFe2O4) nanocomposites for enhanced eco-friendly photocatalysis: a systematic critical review on mechanisms, performance, and environmental applications.

Water pollution caused by organic and inorganic contaminants, particularly dyes and pharmaceuticals, represents a major environmental challenge. Advanced oxidation processes based on photocatalysts have emerged as efficient and sustainable approaches for water and wastewater treatment. Copper ferrite (CuFe2O4) is considered a promising photocatalyst owing to its narrow bandgap, visible-light activity, chemical stability, and magnetic properties. Despite extensive experimental investigations, a comprehensive systematic comparison of CuFe2O4-based photocatalysts under diverse operational conditions has remained limited. In this study, a systematic review following PRISMA guidelines was conducted using studies published between January 2014 and November 2025 indexed in Scopus, PubMed, Web of Science, and ScienceDirect. From an initial pool of 397 studies, 98 articles met the inclusion criteria. Key parameters&#xa0;-&#xa0;including pollutant type, pH, catalyst dosage, initial pollutant concentration, irradiation time, light source, and degradation efficiency&#xa0;-&#xa0;were quantitatively compared to identify performance trends and operational optima. The results demonstrate that CuFe2O4-based nanocomposites, particularly heterojunction, Z-scheme, and S-scheme architectures combined with TiO2, g-C3N4, graphene, and metal oxides, achieve high degradation efficiencies (often >90&#x202f;%) for a wide&#xa0;range of organic pollutants and selected inorganic contaminants (e.g., Cr(VI)). Enhanced charge separation and suppressed electron-hole recombination were identified as the primary factors contributing to improved photocatalytic activity. In addition, the intrinsic magnetic properties of these&#xa0;nanocomposites enable facile catalyst recovery and reuse. In conclusion, CuFe2O4-based nanocomposites, especially those&#xa0;incorporating advanced heterojunction architectures, emerge as highly efficient and magnetically recoverable photocatalytic platforms for sustainable water and wastewater treatment, with strong potential for scalable implementation and real-wastewater applications.

Catalysis

Diagnostic performance of machine learning models versus established risk stratification for intracranial aneurysm rupture: a systematic review and bivariate meta-analysis.

BACKGROUND: Machine learning (ML) models have been proposed to improve the discrimination of intracranial aneurysm rupture status beyond established clinical risk stratification tools. However, reported performance is heterogeneous and the relative contribution of model architecture and feature dominance remains unclear. METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analyses-diagnostic test accuracy systematic review and diagnostic meta-analysis of studies evaluating ML models for intracranial aneurysm rupture discrimination. PubMed, Embase and CENTRAL were searched to February 2026. Sensitivity and specificity were pooled using a bivariate random-effects model, with summary receiver operating characteristic curves generated across training, internal testing and external validation datasets. Models were compared with regression-based approaches and Population, Hypertension, Age, Size of aneurysm, Earlier subarachnoid haemorrhage, Site of aneurysm (PHASES) scores. Subgroup and meta-regression analyses explored associations between algorithm family and feature domain. RESULTS: Sixty-two retrospective cohorts (29&#x2009;709 patients 209 models) met the inclusion criteria. In training datasets, pooled sensitivity and specificity for ML were 0.81 (95% CI 0.75 to 0.85)&#x2009;and 0.83 (0.80-0.86), with an area under the curve (AUC) of 0.878, exceeding PHASES (AUC 0.667). In testing datasets, ML retained higher discrimination (AUC 0.837) than regression models (0.806) and PHASES (0.646). In external validation, sensitivity was preserved (0.82), but specificity declined (0.66). Deep learning demonstrated the highest AUCs (training and testing). Incorporation of haemodynamic or radiomic features improved pooled discrimination relative to morphology alone. Evidence of small-study effects and mostly unclear Prediction Model Risk Of Bias Assessment Tool ratings were observed. CONCLUSIONS: ML approaches demonstrate higher pooled discrimination for aneurysm rupture status than conventional risk scores in retrospective datasets, but reduced external validation specificity and heterogeneity limit confidence for clinical translation. Prospective, externally validated, calibrated models are required before integration into routine cerebrovascular risk stratification.

Humans

Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.

Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p&#x202f;<&#x202f;0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7&#x202f;h, whereas rapid barcoding required approximately 40&#x202f;h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200&#x202f;min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.

Poliovirus

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Comparison of the predictive performance of systemic immune-inflammation index and neutrophil-to-lymphocyte ratio for three-month poor functional outcome in ischemic stroke: a systematic review and meta-analysis.

INTRODUCTION: Ischemic stroke (IS) is a leading cause of global mortality and disability. Early and accurate prognosis is crucial for patient management. The neutrophil-to-lymphocyte ratio (NLR) and systemic immune-inflammation index (SII) are emerging inflammatory biomarkers; however, their relative predictive value for three-month poor functional outcome (modified Rankin Scale [mRS]&#x2009;>&#x2009;2) remains uncertain. METHODS: We systematically searched PubMed, Embase, Web of Science, and the Cochrane Library up to 20 July 2025, adhering to PRISMA guidelines. Observational studies reporting the association of SII or NLR with three-month poor outcome were included. Study quality was evaluated using the Newcastle-Ottawa Scale. Area under the curve (AUC), odds ratios (OR), and standardized mean differences (SMD) were pooled using random-effects models in Stata 16.0. RESULTS: Twenty-one studies involving 7520 IS patients were analysed. NLR demonstrated marginally superior discriminative ability compared to SII (AUC 0.71, 95% CI: 0.67-0.76 vs. 0.68, 95% CI: 0.64-0.71), though this difference was not statistically significant. Elevated NLR was significantly associated with poor outcome (OR = 1.26, 95% CI: 1.17-1.37, p&#x2009;<&#x2009;.001), whereas SII was not (OR = 1.00, 95% CI: 1.00-1.00, p&#x2009;=&#x2009;.384). Both markers showed moderate effect sizes (SMD: NLR = 0.69, SII = 0.72; p&#x2009;<&#x2009;.001). NLR performed better in non-intervention and Chinese subgroups, while SII exhibited consistent AUC values across treatment and ethnic subgroups. CONCLUSION: NLR and SII are accessible prognostic markers in IS. NLR demonstrates superior accuracy and a significant association with poor outcome, while SII shows greater stability across patient subgroups. Both may assist in risk stratification, in resource-limited settings.

Humans

Impact of neoprene wetsuits on lung volumes and work of breathing: implications for military diver safety and performance.

INTRODUCTION: Neoprene wetsuits may impose mechanical constraints on the chest wall, potentially altering respiratory function. This study investigated the impact of neoprene wetsuits on lung volumes, airway mechanics, and work of breathing (WOB) in healthy male divers. METHODS: A randomised crossover trial was conducted with 31 male divers at the Royal Netherlands Navy Diving Medical Centre. Participants underwent pulmonary function testing, including spirometry, body plethysmography, the forced oscillation technique (FOT), and diffusion capacity measurements, both with and without a hoodless standardised 5 mm neoprene full body wetsuit with a neoprene neck seal. Primary outcomes included changes in forced vital capacity (FVC), functional residual capacity (FRC), airway resistance (Raw), reactance (Xrs), and WOB. RESULTS: Wearing a neoprene wetsuit led to statistically significant reductions in FVC (2.8%, P < 0.05), forced expiration in one second (2.9%, P < 0.05), FRC (4.0%, P < 0.05), and expiratory reserve volume (10.9%, P < 0.05), alongside increases in inspiratory capacity and tidal volume. Raw increased significantly (P < 0.05), while the FOT revealed altered airway mechanics, evidenced by increased Xrs at multiple frequencies (P < 0.05). Diffusion capacity remained unchanged, suggesting preserved alveolar-capillary function. CONCLUSIONS: Neoprene wetsuits induce mechanically restrictive effects on the chest wall, reducing static and dynamic lung volumes and increasing WOB. While these changes may not be clinically relevant at rest, their impact needs to be determined during strenuous or prolonged dives, particularly when combined with other equipment that limits thorax excursions. Future research should explore the effects of the military 5 mm wetsuit under immersed conditions to better understand their operational impact on diver performance and safety.

Male

Optimization of a niosomal formulation for Quercetin delivery: Comparative effects on growth performance, antioxidant and immune responses, and disease resistance against Streptococcus iniae in rainbow trout (Oncorhynchus mykiss).

Quercetin (QUR) is a flavonoid with antibacterial and antioxidant properties that has been studied for its effects on fish health and the immune system. Due to the low bioavailability of QUR, the present study was primarily aimed at developing a niosomal formulation of QUR to enhance its bioavailability and therapeutic properties. The performance of niosomal QUR was then compared with that of its free form by evaluating their effects on the growth and immune system of rainbow trout, Oncorhynchus mykiss. For this purpose, an optimal QUR-containing niosome was formulated by testing different proportions of cholesterol, surfactant, and stabilizer, and the niosomes were then added to the fish diet. A QUR-free diet and a diet containing QUR-free niosomes (QFN) were considered control groups. Niosomes prepared at low hydrophilic-lipophilic balance (HLB) values showed higher QUR entrapment efficiency (QUR-EE%) (P&#x202f;<&#x202f;0.01). An increase in the molar ratio of cholesterol to surfactant significantly reduced QUR-EE% (P&#x202f;<&#x202f;0.05). A surfactant/cholesterol/stabilizer ratio of 1:1:0.1 increased QUR-EE% (P&#x202f;<&#x202f;0.05). The particle size of the niosomes was also affected by HLB and the surfactant/cholesterol/stabilizer ratio. Low HLB values resulted in smaller particle sizes (P&#x202f;<&#x202f;0.01). Furthermore, a surfactant/cholesterol/stabilizer ratio of 1:1:0.1 resulted in the smallest niosomal particle size (P&#x202f;<&#x202f;0.05). The presence of diacetyl phosphate as the stabilizer in the formulation improved the niosomal zeta potential to -40.55&#x202f;mV. The optimal niosomal formulation (HLB&#x202f;=&#x202f;6.6; surfactant/cholesterol/stabilizer ratio of 1:1:0.1) remained stable at 2&#x202f;&#xb0;C over 10 days of storage, as the niosomal QUR content and size did not show significant changes during this period (P&#x202f;>&#x202f;0.01). After preparation of the diets containing the optimal niosomal QUR, fish were fed the experimental diets for two months. QUR, in both niosomal and free forms, resulted in better growth performance than the QUR-free diets (P&#x202f;<&#x202f;0.01). There were no significant differences in growth performance between the free and niosomal forms of QUR; however, 500&#x202f;mg/kg QUR showed significantly better growth performance than 250&#x202f;mg/kg QUR (P&#x202f;<&#x202f;0.01). Although both the niosomal and free forms of QUR enhanced immune and antioxidant components in the fish, the effects of the niosomal form were more significant (P&#x202f;<&#x202f;0.01). In addition, QUR in both free and niosomal forms reduced fish mortality after challenge with Streptococcus iniae. In conclusion, the results of this study suggest that the niosomal form of QUR has strong potential for improving the immune system of fish and increasing resistance to S. iniae infection.

Animals

Effect of a PROtein-enriched MEDiterranean diet and EXercise (PROMED-EX) on nutritional status and cognitive performance in older adults at risk of undernutrition and cognitive decline: the PROMED-EX randomized controlled trial.

BACKGROUND: Undernutrition in older adults is associated with adverse health outcomes including cognitive decline, yet evidence for effective preventive strategies is limited. OBJECTIVES: The objective of this study was to investigate effects of a protein-enriched Mediterranean diet, with and without exercise, on nutritional status and cognitive performance in "at risk" community-dwelling older adults. METHODS: A total of 105 participants (69% female; aged 67.7 &#xb1; 6.1 y) at risk of undernutrition and cognitive decline were randomized to 1 of 3 groups: 1) PROMED-EX (personalized dietary counseling plus home-based exercise); 2) PROMED (personalized dietary counseling only); or 3) CON (healthy eating leaflet). The primary outcome was change in nutritional status at 6 mo, measured by the Mini Nutritional Assessment (MNA; 0-30 points). Secondary outcomes included neurocognitive test battery (NTB) z-score, PROMED diet quality score (0-14), physical performance, and health-related quality of life. Analyses followed an intention-to-treat approach using linear regression to assess between-group differences in 6-mo outcomes. RESULTS: At baseline, the mean MNA score was 22.5 &#xb1; 2.3. After 6 mo, nutritional status improved significantly in both intervention groups compared with CON: mean differences in MNA were 2.7 [95% confidence interval (CI): 1.3, 4.2] for PROMED and 2.9 (95% CI: 1.5, 4.3) for PROMED-EX (both P < 0.001). Cognitive function also improved, with NTB z-score differences of 0.3 (95% CI: 0.1, 0.5; P = 0.01) in PROMED and 0.2 (95% CI: 0.0, 0.4; P = 0.02) in PROMED-EX compared with CON. Diet quality scores significantly increased with mean differences of 4.0 (95% CI: 2.9, 5.0) for PROMED and 3.9 (95% CI: 2.8, 4.9) for PROMED-EX compared with CON (both P < 0.001). Despite low adherence to exercise, additional benefits were observed for physical performance and quality of life. CONCLUSIONS: Dietary intervention improved nutritional status in community-dwelling older adults at risk of undernutrition. Correcting undernutrition could help to slow cognitive decline and promote physical health and quality of life during aging. This study was registered at clinicaltrials.gov as NCT05166564.

Humans

Effects of adjunctive bifrontal tDCS on depressive symptoms and cognitive performance in major depressive disorder: A randomized, double-blind, sham-controlled crossover pilot study.

BACKGROUND: Evidence for antidepressant effects of transcranial direct current stimulation (tDCS) in major depressive disorder (MDD) is heterogeneous, and cognitive effects remain uncertain. We compared depressive symptoms and DSST performance during active and sham bifrontal tDCS in medicated outpatients with MDD and baseline HAMD-17 &#x2265; 15. METHODS: In this randomized, double-blind, sham-controlled crossover pilot trial, adults with MDD and inadequate response to an adequate antidepressant trial were assigned to active&#x2192;sham or sham&#x2192;active tDCS sequences while continuing antidepressants. Each period comprised 10 sessions over 2 weeks. Active stimulation was delivered at 2 mA for 20 min (anode F3, cathode F4); sham used the same montage with brief ramping only. No washout interval was used. No washout interval was used. The primary outcome was HAMD-17; secondary outcomes were DSST and CGI ratings. RESULTS: Of 38 randomized participants, 32 completed both periods and were analyzed per protocol. HAMD-17 scores were lower during active than sham stimulation (mean difference -3.63, 95% CI -5.86 to -1.40; p = 0.002), but the condition-by-sequence interaction was significant (p = 0.026). No condition effect was observed for DSST (p = 0.261) or CGI-Severity (p = 1.000); CGI-Improvement was strongly sequence-dependent (p < 0.001). In an exploratory first-period analysis, adjusted T1 HAMD-17 scores were lower in the active-first group (adjusted difference -4.90, 95% CI -7.92 to -1.87; p = 0.003). Adverse effects were mild and transient. CONCLUSIONS: Active tDCS was associated with lower HAMD-17 scores, but the pooled contrast was order-dependent and cannot be interpreted as a definitive treatment effect. No DSST benefit was observed.

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Diagnostic performance of intraoperative in vivo hyperspectral imaging for meningioma grading and molecular alterations: results from a prospective feasibility study.

OBJECTIVE: Hyperspectral imaging (HSI) is an emerging intraoperative, noninvasive, contrast agent-free imaging modality that enables quantitative assessment of tissue composition. The present study aimed to investigate whether HSI-derived tissue parameters correlate with WHO grade and molecular markers of aggressiveness in cranial meningiomas. METHODS: In this prospective study, intraoperative in vivo HSI was performed using the TIVITA tissue system, capturing spectral signatures between 500 and 1000 nm. Quantitative tissue parameters included tissue oxygen saturation (StO2), near-infrared perfusion index, organ hemoglobin index (OHI), and tissue water index (TWI). HSI parameters were correlated with histopathological WHO grade and molecular alterations, including CDKN2A/B deletion, TERT promoter mutation, and 1p/22q loss. Group differences were analyzed using one-way ANOVA, and diagnostic performance was assessed using receiver operating characteristic (ROC) analysis. RESULTS: Forty-six meningiomas were included, comprising WHO grade 1 (n = 35) and WHO grade 2-3 (n = 11) tumors. TWI was significantly higher in WHO grade 2-3 meningiomas compared with WHO grade 1 tumors (mean 0.49 [SD 0.12] vs 0.38 [SD 0.17], p = 0.048). ROC analysis demonstrated an area under the ROC curve (AUC) of 0.71 (95% CI 0.56-0.86, p = 0.036) for TWI in discriminating higher-grade disease. A TWI cutoff &#x2265; 0.367 identified all WHO grade 2-3 meningiomas with 100% sensitivity and 100% negative predictive value. In a molecular subgroup (n = 15), OHI appeared higher in tumors with homozygous CDKN2A/B deletion than in nondeleted tumors (mean 0.77 [SD 0.04] vs 0.62 [SD 0.10]). However, only 3 CDKN2A/B-deleted cases were available, and these findings should be considered descriptive. ROC analysis yielded an AUC of 0.89 (95% CI 0.71-1.00). An OHI cutoff &#x2265; 0.712 identified all three CDKN2A/B-deleted tumors (100% sensitivity), with 83.3% specificity and 86.7% accuracy. CONCLUSIONS: The present investigation demonstrated that HSI-derived tissue water and hemoglobin metrics provide biologically meaningful information in meningiomas. Low tissue water content appeared to rule out higher-grade diseases in this first subset cohort, while elevated hemoglobin showed a potential association with CDKN2A/B deletion in a small exploratory subgroup. These findings support the potential of HSI as a real-time noninvasive tool for intraoperative risk stratification and should be evaluated in large-scale studies. German Clinical Trials Register no. DRKS00036771 (www.drks.de).

Humans

Beyond predictive performance: A systematic review and critical methodological appraisal of AI/ML and conventional modelling strategies in breast, colorectal, and pancreatic Cancer.

BACKGROUND: Predictive modelling for cancer risk, treatment-related complications, and survival is central to precision oncology. Conventional logistic regression (LR) and Cox proportional hazards (CoxPH) regression remain widely used but are limited when modelling nonlinear interactions, high-dimensional imaging features, and multimodal clinical-metabolic predictors. Artificial intelligence (AI) and machine learning (ML) methods offer expanded capability through automated feature extraction, ensemble learning, and flexible survival modelling, but the evidence on when AI/ML adds value over conventional models across cancer sites and predictive tasks remains fragmented. OBJECTIVE: To systematically evaluate the methodological performance, validation strategies, and translational limitations of AI/ML models compared with conventional statistical models in published predictive-modelling studies for breast, colorectal, or pancreatic cancer. METHODS: PubMed, Scopus, and Web of Science were searched for studies published between January 2019 and March 2025. Two reviewers independently conducted title-and-abstract screening, full-text eligibility assessment, and PROBAST risk-of-bias assessment. Sixty-five studies (n&#xa0;=&#xa0;907,567 participants) were narratively synthesised by cancer site, predictive task, model family, comparator, validation strategy, predictor modality, and calibration or explainability reporting. RESULTS: The 65 studies comprised breast cancer (n&#xa0;=&#xa0;35), colorectal cancer (n&#xa0;=&#xa0;21), and pancreatic cancer (n&#xa0;=&#xa0;9). AI/ML superiority over LR and CoxPH was task- and data-dependent. CNN- and U-Net-based models predominated in imaging and body-composition tasks, tree-based ensembles consistently outperformed LR for tabular perioperative complication prediction, and CoxPH remained competitive, and in the largest pancreatic risk study, superior to XGBoost (C-index 0.802 vs 0.723) in well-structured datasets. PROBAST analysis-domain risk was moderate in 54 of 65 studies (83%), driven by limited external validation, sparse calibration reporting (11/65), and few decision-curve analyses (7/65). CONCLUSION: AI/ML adds the most methodological value in imaging-derived feature extraction and nonlinear perioperative prediction, while conventional regression remains preferable in large, structured datasets with linear predictors. Clinical translation requires standardised body-composition definitions, external validation, calibration assessment, decision-curve analysis, and explainability, in line with TRIPOD+AI and CLAIM standards.

Humans

Exercise Snacks Are Feasible to Perform in the Real World and Improve Physical Capacity for Adults Living With Non-Insulin Treated Type 2 Diabetes: A Randomised Trial.

AIMS: To investigate the feasibility and preliminary efficacy of a 12-week remotely-delivered exercise snacks (ES) intervention in adults with type 2 diabetes. MATERIAL AND METHODS: Insufficiently active adults with type 2 diabetes (N&#x2009;=&#x2009;69; 46 females; mean age&#x2009;&#xb1;&#x2009;SD: 58&#x2009;&#xb1;&#x2009;11&#x2009;years) were randomised to an ES or mobility/stretching comparator group (CON), which involved 4&#x2009;&#xd7;&#x2009;1-min bouts of either vigorous or low intensity exercise, respectively, on &#x2265;&#x2009;5&#x2009;days/week. The primary outcome was feasibility based on adherence. Secondary outcomes included exercise enjoyment (1-7 scale), rating of perceived exertion (RPE; 0-10 scale), heart rate (HR), haemoglobin A1c (HbA1c), blood biomarkers of cardiometabolic health, 30-s sit-to-stand capacity, grip strength, estimated maximal oxygen uptake, and anthropometrics. RESULTS: Weekly adherence (estimated marginal mean [95% confidence interval]: 18 bouts [16-21] for both groups; p&#x2009;=&#x2009;0.99) and total enjoyment (ES: 4.5 [4.1-4.8] vs. CON: 4.3 [4.0-4.7]; p&#x2009;=&#x2009;0.64) were high and not different between groups. Despite higher RPE (5.7 [5.4-6.1]) and peak HR (73 [70-77] % of age-predicted HR maximum) in ES versus CON (2.0 [1.7-2.4] and 61 [58-64] % of age-predicted HR maximum, respectively) (all p&#x2009;<&#x2009;0.001), there were no between-group differences in the change in any secondary outcome (all p&#x2009;>&#x2009;0.05) except for greater sit-to-stand capacity in ES after training (between-group effect estimate [95% confidence interval]: 1.9 repetitions [0.3-3.4]; p&#x2009;=&#x2009;0.02). CONCLUSIONS: Exercise snacks were feasible to perform in the real world and improved sit-to-stand capacity to a greater extent than CON in adults living with type 2 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06407245.

Aged

Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis.

BACKGROUND: Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain. OBJECTIVE: This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, with emphasis on models using non-PSG-derived inputs. METHODS: PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2&#xd7;2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively. RESULTS: A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of &#x2265;5, &#x2265;15, and &#x2265;30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92-0.96; 95% PI 0.71-0.99), 0.87 (95% CI 0.84-0.89; 95% PI 0.66-0.96), and 0.83 (95% CI 0.79-0.87; 95% PI 0.61-0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69-0.84; 95% PI 0.30-0.96), 0.81 (95% CI 0.75-0.85; 95% PI 0.39-0.96), and 0.91 (95% CI 0.87-0.94; 95% PI 0.55-0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG-derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method. CONCLUSIONS: AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG-derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG-derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.

Humans