Search PubMedSearch

SEARCH · Search PubMed

Results for “Excimer laser coronary angioplasty”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

90 records · Page 3Linked to original sources

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Impact of renal dysfunction on immediate versus staged revascularization of non-culprit lesions in patients with ST segment elevation myocardial infarction: a pre-specified subgroup analysis of the randomized MULTISTARS AMI trial.

BACKGROUND: Renal dysfunction might affect outcomes in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease (MVD) undergoing percutaneous coronary intervention (PCI). METHODS: In MULTISTARS AMI, patients with STEMI and MVD were randomized to immediate or staged PCI of non-culprit lesions. In this pre-specified analysis, patients were stratified according to the presence of renal dysfunction at baseline, defined at an estimated glomerular filtration rate (eGFR) of 60&#xa0;ml/min/1.73 m2. Patients with an eGFR&#x2009;<&#x2009;30&#xa0;ml/min/1.73 m2 were excluded from the trial. The primary endpoint was a composite of death, non-fatal myocardial infarction, stroke, unplanned revascularization, or hospitalization for heart failure at 1&#xa0;year. RESULTS: In MULTISTARS AMI, 108 (13%) of 832 patients had renal dysfunction. The primary endpoint occurred more frequently in patients with renal dysfunction (19.4% vs. 11.2%, unadjusted HR 1.82, 95% CI 1.13-2.94), primarily driven by higher rates of death. Among patients with renal dysfunction, the rates of the primary end point were 14.5% and 24.5% in the immediate and staged PCI groups (unadjusted HR 0.55, 95% CI 0.23-1.33). There was no interaction between renal dysfunction and the randomized treatment assignment with respect to the primary end point (adjusted HR 1.30, 95% CI 0.8-2.20, pint 0.82). The occurrence of acute renal insufficiency was statistically similar in patients with renal dysfunction who underwent immediate and staged PCI (10.9% vs. 18.9%, unadjusted HR 0.61, 95% CI 0.22-1.72, pint 0.09). Renal dysfunction at baseline emerged as a strong risk factor for the development of acute renal insufficiency (adjusted HR 5.0, 95% CI 2.30-10.70, p&#x2009;<&#x2009;0.01). CONCLUSIONS: Outcomes with immediate compared to staged multivessel PCI did not appear significantly altered by the presence of renal dysfunction&#xa0;at baseline. (Supported by Boston Scientific; MULTISTARS AMI ClinicalTrials.gov number, NCT03135275).

Humans

Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice: A Randomized Trial of 0/1-Hour vs 0/3-Hour Troponin Testing.

BACKGROUND: For suspected acute coronary syndrome (ACS), guidelines recommend using high-sensitivity troponins (hs-cTn) in accelerated diagnostic pathways (ADPs) with 0/1-hour recommended over 0/3-hour ADP. However, implementation of these ADPs, with universal use of hs-cTns, has not been directly compared in randomized trials OBJECTIVES: This study sought to compare the efficiency and safety of the European Society of Cardiology (ESC) 0/1-hour and a 0/3-hour ADP when implemented in real-world clinical practice. METHODS: This pragmatic, randomized, noninferiority implementation trial compared the safety and efficiency of clinician decision making using these 2 pathways. To prevent incorporation bias, an independent hs-cTnI was used for formal adjudication using the fourth universal definition of myocardial infarction (MI). Efficiency was judged by the proportion of patients discharged within 4 hours. The safety endpoint was major adverse cardiac events (MACE) within 30 days (adjudicated index or representation type 1 MI, cardiovascular death, and urgent coronary revascularization) for those who were considered not to have ACS and discharged. The noninferiority margin, for absolute difference in sensitivity, between the ESC 0/1-hour and the 0/3-hour ADP was set at 3%, assessed with a 1-sided 97.5% CI. RESULTS: From December 2021 to July 2024, of 13,983 screened 3,543 individual patients with suspected ACS were recruited and consented from 2 major emergency departments in North-West England, with 100% follow-up achieved for all representations to any national hospital. The median age was 60 years (IQR: 49.5-70.5 years), 53% were men, 6.7%, and 7.6% had adjudicated index type 1 MI and MACE within 30 days, respectively. The turnaround time from sample to result for central laboratory hs-cTnT was 81 minutes (IQR: 69-101 minutes). The proportion of patients discharged within 4 hours was relatively low and did not differ substantially (21.8% vs 19.2%, P = 0.07). In addition, the 0/1-hour pathway was noninferior for safety, in patients discharged, compared with the 0/3-hour pathway, absolute difference in sensitivity was +4.2% (1-sided 97.5% CI: -2.5) in favor of the 0/1-hour pathway. The calculated sensitivities were 93.7% (95% CI: 88.4%-97.1%) vs 89.5% (95% CI: 82.7%-94.3%), respectively. CONCLUSIONS: Implementation of the ESC 0/1-hour pathway failed to discharge significantly more patients within 4 hours of presentation compared with the 0/3-hour ADP. In addition, The ESC 0/1-hour was noninferior to the 0/3-hour hs-cTn pathway for safety of discharge, although safety for both pathways was less than that imputed by observational studies. This trial demonstrates that perceived benefits to emergency department efficiency of a reduced sampling interval are mitigated by central laboratory turnaround times as well as system constraints. (Pragmatic Randomised Trial of the ESC 0/&#x200b;1 Versus 0/&#x200b;3 Hour Troponin Pathway [MACROS2]; NCT05322395).

Acute Coronary Syndrome

Teaching Acute Coronary Syndrome High-Risk ECG Interpretation and Clinical Decision-Making Through FOAMed Videos and Podcast Versus Print-Based Materials Among Emergency Care Providers: Randomized Controlled Mixed Methods Trial.

BACKGROUND: Accurate interpretation of high-risk acute coronary syndrome (ACS) electrocardiograms (ECGs) is essential for early diagnosis and timely reperfusion, yet substantial deficits persist across health care professions. Digital self-learning formats such as FOAMed (Free Open Access Medical Education) are widely used, but their effectiveness has rarely been evaluated for complex, high-risk ACS ECG patterns. Existing ECG education studies often focus on students or single professional groups and established ST-segment elevation myocardial infarction (STEMI) criteria, leaving newer guideline-recognized STEMI equivalents, selected emerging occlusion myocardial infarction (OMI)-related patterns, and interprofessional emergency care underrepresented. OBJECTIVE: This study aimed to compare the effectiveness of FOAMed podcast and videos versus traditional print-based materials for teaching high-risk ACS ECG patterns and related clinical decision-making in emergency providers. METHODS: We conducted a prospective, interprofessional, controlled mixed methods trial across 5 training sites in Germany. Paramedics, prehospital emergency physicians, and emergency department clinicians received either a FOAMed multimedia module or print-based materials through concealed allocation; deviations from the intended 1:1 ratio resulted from participant no-shows. The intervention consisted of a 30-minute supervised self-learning session. In total, 103 participants were allocated to FOAMed (n=45) or print-based materials (n=58). Two coprimary outcomes were assessed: ECG interpretation accuracy and text-based ACS clinical decision-making. Secondary outcomes included subjective confidence, learning experience, and exploratory qualitative free-text responses. Outcome assessment was automated and blinded; mixed ANOVA was the primary analysis. The study was not prospectively registered because it assessed educational outcomes in health care professionals rather than patient health outcomes. RESULTS: All 103 participants completed the study. Both groups improved, with greater gains in the FOAMed group: ECG interpretation increased from 55% to 65.5% and text-based ACS clinical decision-making from 45% to 68%, versus 57% to 60% and from 47% to 63%, respectively, in the print-based group. Effect sizes were &#x3b7;&#xb2;=0.055 for ECG interpretation and &#x3b7;&#xb2;=0.044 for clinical decision-making. Exploratory subgroup analyses provided no evidence of differential effects across age, gender, or professional background and were likely underpowered. Qualitative responses (46 and 37 entries) provided contextual insights into perceived clarity, engagement, and practical relevance supporting the quantitative findings. CONCLUSIONS: This study is innovative in directly comparing a curated FOAMed multimedia module with selected print-based materials in an interprofessional emergency care population. It differs from existing research by focusing on subtle, emerging ischemic patterns and evaluating realistic, time-limited self-learning formats. The findings provide evidence that curated FOAMed resources can produce greater short-term improvements in ECG interpretation and text-based ACS clinical decision-making than traditional print-based materials in this setting. Although implications for clinical performance remain hypothetical, concise, high-quality digital modules may represent a practical supplement to structured continuing education in emergency care.

Humans

Photobiomodulation as an Adjunct to Resistance Training in Older Adults: A Systematic Review and Meta-Analysis.

BACKGROUND: Photobiomodulation (PBM) has been proposed as an adjunct to resistance training to enhance strength adaptations; however, findings from randomized controlled trials (RCTs) remain inconsistent. This study aimed to evaluate whether adjunctive PBM improves maximal strength gains when combined with periodized resistance training in older adults. METHODS: RCTs were identified through systematic searches of PubMed, Scopus, Embase, PEDro, Web of Science, the Cochrane Library, and CNKI from inception to January 2026. Eligible studies examined PBM delivered via low-level laser therapy or light-emitting diodes in combination with resistance training or other strength-oriented loading tasks. Prespecified meta-analyses were restricted to trials combining PBM with periodized resistance training that reported one-repetition maximum (1RM) outcomes; other studies were included in a narrative synthesis. RESULTS: Eleven RCTs (n = 456) were included. Five trials (PBM plus resistance training: n = 74; control: n = 72) met the criteria for meta-analysis. PBM combined with resistance training did not significantly improve maximal muscle strength compared with sham PBM (SMD = 0.26, 95% CI -0.08 to 0.59; p = 0.14; I2 = 4%). Subgroup analyses showed a nonsignificant trend favoring PBM for unilateral 1RM, with no effect for bilateral outcomes and no significant subgroup differences. Sensitivity analyses indicated that the unilateral effect was dependent on individual studies. In nonresistance training contexts, some studies reported potential benefits for fatigue-, recovery-, or function-related outcomes, particularly in frail or critically ill older adults, although findings were inconsistent. CONCLUSION: Current evidence does not demonstrate a clear additional benefit of PBM on maximal strength when combined with resistance training in older adults, although a small effect cannot be excluded. PBM may have selective value in improving recovery-related outcomes and supporting training tolerance in vulnerable populations. Larger, well-designed RCTs are needed to clarify its role.

Humans

Role of routine surveillance stress testing in patients with or without imaging-guided or physiology-guided PCI.

OBJECTIVE: The optimal follow-up strategy for high-risk patients who underwent imaging-guided or physiology-guided percutaneous coronary intervention (PCI) remains uncertain. We investigated whether routine surveillance stress testing after PCI provides clinical benefit when the procedure is guided by intravascular ultrasonography (IVUS) or fractional flow reserve (FFR). METHODS: In the Pragmatic Trial Comparing Symptom-Oriented vs Routine Stress Testing in High-Risk Patients Undergoing PCI randomised trial, 1706 high-risk patients who underwent PCI were assigned to either routine functional testing at 1 year or standard care alone. In this prespecified subgroup analysis, patients were subsequently categorised according to whether IVUS or FFR was used at the index procedure. The primary outcome was a composite of death, myocardial infarction or hospitalisation for unstable angina over 2 years. RESULTS: Among the randomised population, 74% underwent IVUS-guided intervention and 36% underwent FFR-guided intervention. At 2 years, rates of the primary outcome were similar between routine testing and standard care both in patients treated with IVUS guidance (5.3% vs 6.7%; HR 0.79; 95% CI 0.50 to 1.24) and without IVUS guidance (5.7% vs 3.8%; HR 1.52; 95%&#x2009;CI 0.63 to 3.68; interaction p=0.21). Comparable results were observed in patients with FFR guidance (2.6% vs 3.9%; HR 0.65; 95%&#x2009;CI 0.26 to 1.58) and without FFR guidance (7.0% vs 7.1%; HR 0.99; 95%&#x2009;CI 0.63 to 1.55; interaction p=0.59). Routine functional testing was consistently associated with higher use of invasive coronary angiography and repeat revascularisation, without improvement in clinical outcomes. CONCLUSIONS: Among high-risk patients who underwent PCI, routine surveillance stress testing did not reduce the risk of death, myocardial infarction or unstable angina, regardless of the use of IVUS or FFR at the index procedure. Routine functional testing increased downstream invasive procedures without clinical benefit. These findings support guideline recommendations against routine surveillance testing after PCI. TRIAL REGISTRATION NUMBER: NCT03217877.

Humans

ESC quality indicators for post-myocardial infarction care: transition and chronic coronary syndrome phases.

AIMS: We aimed to develop the European Society of Cardiology (ESC) quality indicators (QIs) for myocardial infarction (MI), from 1 year after hospital discharge, corresponding to transition to the chronic coronary syndrome phases. METHODS AND RESULTS: We collaborated with the European Association of Preventive Cardiology (EAPC) and developed QIs for the long-term management of patients following MI. We applied the ESC methodology for QI development by (i) determining key domains of post-MI care; (ii) developing candidate QIs by performing a systematic review of the literature, and (iii) selecting the final set of QIs using a modified Delphi approach. In total, 18 QIs were identified across seven domains of care including (i) structural framework, (ii) risk assessment and follow-up, (iii) pharmacological management, (iv) rehabilitation, behavioural, and preventive interventions, (v) coronary revascularization, (vi) clinical outcomes, and (vii) patient-reported outcomes. CONCLUSION: We present the ESC QIs from 1 year after hospitalization for MI, to standardize and address gaps in care for this high-risk group. These QIs are supported by evidence from contemporary literature, endorsed by expert consensus, and aligned with the 2024 ESC guidelines on the management of chronic coronary syndromes. LAY SUMMARY: Measures to evaluate and improve the long-term management of patients following a heart attack are needed. In this paper, we identified key aspects of care that can help clinicians, decision-makers and patients improve the quality of care, from one year after a heart attack onwards, and help address inequalities and variations in clinical practice.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

Antimicrobial photodynamic therapy mediated by phenothiazine photosensitizers against Candida albicans and Candida auris: a systematic review.

Fungal infections caused by Candida albicans and Candida auris represent an increasing clinical challenge, particularly due to biofilm formation and rising antifungal resistance. Antimicrobial photodynamic therapy (aPDT) has emerged as a potential alternative strategy, with phenothiazine-based photosensitizers being among the most extensively investigated compounds. This systematic review aimed to evaluate the application of phenothiazine-mediated aPDT in in vitro studies against C. albicans and C. auris. A comprehensive search was conducted in PubMed, Embase, and Scopus, including studies published within the last 10 years. Forty in vitro studies met the eligibility criteria and were synthesized descriptively due to substantial methodological heterogeneity. Overall, aPDT was associated with reductions in fungal viability, with generally greater effects reported in planktonic models compared with biofilms. Methylene blue was the most frequently investigated photosensitizer, applied across a broad range of concentrations and dosimetric parameters, resulting in variable antifungal responses. Other phenothiazine derivatives, including toluidine blue O, dimethyl methylene blue, new methylene blue, and S137, were also associated with antifungal activity under specific experimental conditions but remain comparatively underexplored. Studies involving C. auris were less frequent and suggested lower susceptibility compared with C. albicans, particularly in biofilm models. Given the substantial variability in experimental protocols, especially regarding photosensitizer concentration, light parameters, and biofilm maturation, the findings should be interpreted with caution and limit direct comparison across studies. These findings support the antifungal potential of phenothiazine-mediated aPDT while emphasizing the need for methodological standardization and expanded investigation of C. auris.

Photochemotherapy

Routine methods misidentify Serratia spp.: Limitations of MALDI-TOF MS revealed by whole-genome sequencing.

Accurate species-level identification within the genus Serratia remains challenging due to extensive phenotypic overlap and high genomic relatedness among closely related and recently described taxa. This study presents an evaluation of routine and genome-based identification approaches applied to clinical Serratia isolates, integrating phenotypic assays, MALDI-TOF MS (Bruker Daltonics), 16S rRNA gene sequencing, and Whole-Genome Sequencing (WGS). A total of 103 isolates collected from a teaching hospital were analyzed. WGS was performed on a subset of isolates. Conventional biochemical methods classified all isolates as Serratia marcescens, whereas MALDI-TOF MS identified 60.1% as S. marcescens, 11.6% as S. ureilytica, and 28.1% just at the genus level. Peak analysis from MALDI-TOF MS revealed specific peaks associated with S. marcescens and S. ureilytica, but limited discriminatory power. WGS of six isolates initially identified as S. ureilytica by MALDI-TOF MS revealed reclassification as Serratia sarumanii (n = 5) and Serratia montpellierensis (n = 1), supported by Average Nucleotide Identity (ANI), Average Amino Acid Identity (AAI), and Digital DNA-DNA Hybridization (dDDH) thresholds. In contrast, 16S rRNA analysis showed limited species-level resolution. Phylogenomic and SNP-based analyses confirmed these classifications with strong support. Overall, this study underscores the critical role of high-resolution genomic approaches for precise species identification and highlights the need for continuous expansion and curation of MALDI-TOF MS reference databases to support reliable clinical diagnostics and epidemiological surveillance of emerging Serratia species.

Spectrometry, Mass, Matrix-Assisted Laser Desorpti

Effect of protective ventilation throughout the intubation period on perioperative oxygenation in patients undergoing MIDCABG: a randomised controlled trial.

INTRODUCTION: Minimally invasive direct coronary artery bypass grafting (MIDCABG) requires prolonged one-lung ventilation (OLV), increasing postoperative pulmonary complications (PPCs) risk. We investigated whether protective lung ventilation (PLV) throughout intubation benefits MIDCABG patients. METHODS: In this single-center randomized study, MIDCABG patients received PLV (low tidal volume of 6-8&#x2009;mL&#xb7;kg-1, PEEP of 6&#x2009;cm H2O, alveolar recruitment maneuvers) or conventional mechanical ventilation (CMV, tidal volume of 8-10&#x2009;mL&#xb7;kg-1, without PEEP or maneuvers) from tracheal intubation to extubation. The primary outcome was perioperative oxygenation, assessed by the PaO2/FiO2 ratio. RESULTS: Sixty patients (n = 30 per group) were enrolled. Compared with CMV, PLV improved PaO2/FiO2 ratios (mean difference at OLV60: 34.56&#x2009;mmHg; 95% CI: 11.78-57.33; p&#x2009;<&#x2009;0.01), shortened median durations of postoperative mechanical ventilation (median difference: -4.5&#x2009;h, 95% CI: -8.5 to -0.5; p&#x2009;=&#x2009;0.013) and hospital stay (median difference: -3.0&#x2009;days, 95% CI: -5.0 to -1.0; p&#x2009;=&#x2009;0.019). PLV also reduced driving pressure, airway pressure and intrapulmonary shunt during OLV (all p&#x2009;<&#x2009;0.05). Desaturation occurred in 23.3% of CMV patients and 13.3% of PLV patients (p&#x2009;=&#x2009;0.506). Hemodynamic parameters were generally comparable between groups, except for lower MPAP and PVRI in the PLV group during OLV and after ICU admission (p&#x2009;<&#x2009;0.05). The incidence of PPCs did not differ between groups. CONCLUSIONS: In patients undergoing MIDCABG, PLV applied throughout intubation improved perioperative oxygenation and shortened the duration of postoperative mechanical ventilation and hospital stay, but did not reduce PPCs. CLINICAL TRIAL REGISTRATION: ChiCTR1900022005.

Humans

Bioepidemiology of cardiac amyloidosis.

BACKGROUND: Cardiac amyloidosis, primarily due to immunoglobulin light chain (AL) or transthyretin (ATTR) amyloid, is an increasingly recognized cause of heart failure. Modern diagnostic advances suggest that ATTR, particularly in older adults, may be more prevalent than historically reported. METHODS: All Olmsted County decedents aged &#x2265;40 years from 1970 to 1976 were identified. Available ventricular myocardium from retained paraffin blocks was screened histologically for amyloid using sulfated Alcian blue staining; positive cases underwent grading and proteomic typing by laser microdissection coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Beyond prevalence estimation, this analysis characterizes amyloid type, deposition grade and distribution, associated comorbidities, and cause-of-death patterns, comparing amyloid-positive decedents with age- and sex-matched controls. RESULTS: Of 2,566 eligible deaths, 1,028 autopsy cases with evaluable myocardium formed the study cohort (mean age 70.5 years; 61.1% male; 97% White). Cardiac amyloid was present in 52 cases giving an overall prevalence of 5.1% (95% CI: 3.8-6.6, which rose from 0% under age 60 to 37.5% (95% CI: 21.1-56.3) in those &#x2265;90 years (p < 0.001). While prevalence estimates were higher in men above age 80 compared to women, there was no evidence of an interaction of age and sex (p = 0.90). The quantity of amyloid was sufficient for typing in 38 cases: ATTR (84.2%), AL (7.9%), serum amyloid A (5.3%), and apolipoprotein A-IV (2.6%). Adjusted estimates assuming untyped mild cases were ATTR-type increased ATTR prevalence to 4.5% (95% CI: 3.3-5.9) overall. Comorbidity profiles were similar between amyloid-positive and negative groups, though syncope and leg weakness were more common in amyloid-positive decedents. CONCLUSIONS: In an unselected autopsy cohort, cardiac amyloid was common, particularly ATTR in older adults. Prevalence increased steeply after age 80. These findings suggest that ATTR amyloidosis is not rare and is likely underdiagnosed and has similar prevalence in women and men, despite the male predominance reported in the literature.

Humans

Intravenous Nicorandil in Patients With ST-Segment Elevation Myocardial Infarction Undergoing Primary PCI: The CLEAN Randomized Clinical Trial.

BACKGROUND: Nicorandil, an adenosine triphosphate-sensitive potassium-channel opener with nitrate-like properties, may reduce reperfusion injury and microvascular obstruction in ST-segment elevation myocardial infarction (STEMI), but large-scale randomized evidence on long-term clinical outcomes is inconclusive. OBJECTIVES: The CLEAN trial aimed to assess whether adjunctive intravenous nicorandil improves 12-month clinical outcomes in patients with STEMI undergoing primary percutaneous coronary intervention. METHODS: In this multicenter, randomized, double-blind, placebo-controlled trial conducted at 49 hospitals in China, patients aged 18 to 80 years with STEMI within 12 hours of symptom onset were randomly assigned (1:1) to receive intravenous nicorandil (6 mg bolus before reperfusion followed by 6 mg/h infusion for 48 h) or matching placebo. Oral nicorandil was prohibited during follow-up. The primary outcome was a composite of cardiovascular death, nonfatal myocardial infarction, target vessel revascularization, or unplanned hospitalization for heart failure within 12 months. RESULTS: Between January 2021 and December 2023, 1,503 patients were enrolled and randomly assigned to nicorandil (n = 748) or placebo (n = 755). The primary composite outcome occurred in 98 patients (13.1%) in the nicorandil group (113 events over 717.2 person-years) and 99 (13.1%) in the placebo group (136 events over 710.3 person-years), with no significant difference between groups (rate ratio: 0.869; 95% CI: 0.650-1.162; P = 0.3429). Among secondary outcomes, nominal reductions were observed in cardiovascular death (1.9% vs 3.6%; HR: 0.515; 95% CI: 0.269-0.983) and target-vessel revascularization (1.1% vs 3.0%; HR: 0.322; 95% CI: 0.143-0.727), whereas rates of nonfatal myocardial infarction and unplanned hospitalization for heart failure were similar between groups. Adverse events did not differ between groups. CONCLUSIONS: In patients with STEMI undergoing primary percutaneous coronary intervention, adjunctive intravenous nicorandil did not significantly reduce the 12-month primary composite outcome. These findings do not support routine use of intravenous nicorandil in unselected patients with STEMI. (Clinical Efficacy and sAfety of Intravenous Nicorandil; NCT04665648).

Humans

Systematic multi-domain screening of lead-specific electrocardiographic features associated with sudden cardiac death.

UNLABELLED: Electrocardiogram (ECG) provides four-dimensional view to the electrical properties of the heart. We performed a comprehensive multi-domain screening to find the most significant lead-specific ECG features associated with sudden cardiac death (SCD). METHODS: We analyzed retrospective data from 21,176 consecutive patients undergoing coronary angiography in Tampere University Hospital between 2007 and 2018. 937 ECG variables provided by the 12SL algorithm were used for the analysis. From those, the significant lead-specific ECG variables were categorized into three subgroups: P-wave, QRS complex, and ST-segment/T-wave. The most significant (i.e., lowest P-value) independent lead-specific ECG variables were tested in multivariate analysis after filtering correlating variables with weaker associations with SCD. RESULTS: Among ventricular depolarization (QRS complex) variables, the strongest associations with SCD were observed for QRS intrinsicoid deflection (lead I) (p&#xa0;=&#xa0;4.6&#xa0;&#xd7;&#xa0;10-8), QRS peak-to-peak amplitude (lead aVR) (p&#xa0;=&#xa0;1.9&#xa0;&#xd7;&#xa0;10-5), and Q-wave amplitude (lead V1) (p&#xa0;=&#xa0;7.6&#xa0;&#xd7;&#xa0;10-6). Among repolarization (ST-segment and T-wave) variables, the strongest predictors of SCD were T-wave amplitude (lead aVR) (p&#xa0;=&#xa0;3.5&#xa0;&#xd7;&#xa0;10-7) and ST-segment end amplitude (lead aVL) (p&#xa0;=&#xa0;8.1&#xa0;&#xd7;&#xa0;10-5). The strongest associations with SCD among atrial depolarization (P-wave) variables were P-wave onset amplitude (lead V6) (p&#xa0;=&#xa0;3.1&#xa0;&#xd7;&#xa0;10-6), P'-wave amplitude (lead V2) (p&#xa0;=&#xa0;2.1&#xa0;&#xd7;&#xa0;10-5), and P-wave duration (lead V2) (p&#xa0;=&#xa0;2.4&#xa0;&#xd7;&#xa0;10-3). These variables remained significant in multivariate analysis alongside global ECG variables (e.g., heart rate, QRS duration, and LVH). CONCLUSION: Systematic screening and utilizing the full prognostic potential of the 12&#x2011;lead ECG reveal several key elements of the electrical properties of the heart that associate with SCD.

Humans

Adaptive proteomic remodeling and eNOS upregulation in luminal endothelium and perivascular adipose tissue of patent saphenous vein grafts after CABG.

OBJECTIVE: Long-term patency of saphenous vein grafts (SVGs) remains a significant challenge in coronary artery bypass grafting (CABG). The biological factors underlying successful human grafts are poorly understood. We aimed to characterize the structural and molecular features associated with successful graft function. METHODS: Patent and occluded SVG and internal thoracic artery (ITA) grafts were obtained from explanted hearts of CABG patients undergoing heart transplantation for end-stage heart failure not attributable to graft failure, along with freshly harvested ITA and SVG controls. Samples underwent histomorphological analysis, immunohistochemistry (IHC), and liquid chromatography-tandem mass spectrometry (LC-MS/MS) proteomics. RESULTS: Patent ITA (ITA-P) showed minimal intimal hyperplasia with medial reinforcement, whereas patent SVGs (SVG-P) had organized, &#x3b1;-smooth muscle actin (&#x3b1;SMA)-positive myofibroblast-rich neointima. Endothelial nitric oxide synthase (eNOS) was markedly upregulated in patent grafts at two sites-the luminal endothelium and adventitial microvessels within perivascular adipose tissue (PVAT)-and lost at both sites in occluded SVG (SVG-O). Adventitial CD31-positive microvessels were significantly increased in patent grafts. Proteomically, ITA-P and SVG-P shared a largely common adaptive proteome enriched in translation, RNA processing, and extracellular matrix (ECM) organization, with shared upstream activation of NR4A3, EGFR, and STAT1, and conduit-specific signatures (IGF-1/RUNX2 in ITA-P; RETN/SRC/PTGES in SVG-P). PTGES was strongly expressed in the adventitia of SVG-P. CONCLUSIONS: Patent arterial and venous bypass grafts exhibited a shared adaptive phenotype characterized by dual-site upregulation of eNOS in both the luminal endothelium and the perivascular microvessels/PVAT. In SVG-P, PTGES was co-upregulated alongside eNOS, indicating a mechanistic link between the proteomic and IHC findings. These findings highlight the perivascular compartment as a site of adaptive, eNOS-associated changes in patent vein grafts.

Humans

Blood Metabolomic Signatures of 1-Hour Glucose Predict Cardiometabolic Risk.

BACKGROUND: Elevated 1-hour glucose levels during an oral glucose tolerance test strongly predict type 2 diabetes (T2D) and cardiovascular disease. We investigated whether the fasting blood metabolome predicting 1-hour glucose could be a target for improving &#x3b2;-cell function, long-term glycemic trajectories, and reducing the risks of T2D and coronary heart disease. We also investigated whether plasma microRNAs derived from key metabolic organs regulate changes in a metabolomic risk score (MRS) for predicting 1-hour glucose. METHODS: Untargeted blood metabolomics and a frequently sampled 75-g oral glucose tolerance test were performed in participants from the OmniCarb trial (n=162). In an independent weight-loss dietary intervention trial (POUNDS Lost [Preventing Overweight Using Novel Dietary Strategies]), temporal changes in MRS and plasma microRNAs measured by genome-wide sequencing were analyzed. In addition, associations of MRS at baseline and its 10-year changes with long-term risk of incident T2D and coronary heart disease were prospectively investigated in the NHS (Nurses' Health Study). RESULTS: We created a fasting blood MRS for predicting 1-hour glucose (Pearson r=0.8) and found significant associations with half-day (diurnal) postprandial glucose excursions and insulin secretion after 5-week controlled feeding interventions varying in carbohydrate amount and glycemic index. In the POUNDS Lost trial, diet-induced changes in MRSs were related to 2-year trajectories of glucose metabolism; circulating microRNAs regulating cardiometabolic abnormalities were pivotal factors influencing these changes. In the NHS, women in the top 20% of MRS had a multivariate-adjusted relative risk of 3.80 (95% CI, 2.22-6.51) for T2D and 1.48 (95% CI, 1.04-2.12) for coronary heart disease compared with those in the lowest 20%. In addition, 10-year increases in plasma metabolites related to 1-hour glucose were linearly associated with a higher risk of T2D. CONCLUSIONS: Our findings indicate that fasting blood metabolomic signatures predicting elevated 1-hour glucose reflect disease pathophysiology and could be targets for preventing T2D and coronary heart disease.

blood glucose