PubMed · 42159533
Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice: A Randomized Trial of 0/1-Hour vs 0/3-Hour Troponin Testing.
Abstract
BACKGROUND: For suspected acute coronary syndrome (ACS), guidelines recommend using high-sensitivity troponins (hs-cTn) in accelerated diagnostic pathways (ADPs) with 0/1-hour recommended over 0/3-hour ADP. However, implementation of these ADPs, with universal use of hs-cTns, has not been directly compared in randomized trials OBJECTIVES: This study sought to compare the efficiency and safety of the European Society of Cardiology (ESC) 0/1-hour and a 0/3-hour ADP when implemented in real-world clinical practice. METHODS: This pragmatic, randomized, noninferiority implementation trial compared the safety and efficiency of clinician decision making using these 2 pathways. To prevent incorporation bias, an independent hs-cTnI was used for formal adjudication using the fourth universal definition of myocardial infarction (MI). Efficiency was judged by the proportion of patients discharged within 4 hours. The safety endpoint was major adverse cardiac events (MACE) within 30 days (adjudicated index or representation type 1 MI, cardiovascular death, and urgent coronary revascularization) for those who were considered not to have ACS and discharged. The noninferiority margin, for absolute difference in sensitivity, between the ESC 0/1-hour and the 0/3-hour ADP was set at 3%, assessed with a 1-sided 97.5% CI. RESULTS: From December 2021 to July 2024, of 13,983 screened 3,543 individual patients with suspected ACS were recruited and consented from 2 major emergency departments in North-West England, with 100% follow-up achieved for all representations to any national hospital. The median age was 60 years (IQR: 49.5-70.5 years), 53% were men, 6.7%, and 7.6% had adjudicated index type 1 MI and MACE within 30 days, respectively. The turnaround time from sample to result for central laboratory hs-cTnT was 81 minutes (IQR: 69-101 minutes). The proportion of patients discharged within 4 hours was relatively low and did not differ substantially (21.8% vs 19.2%, P = 0.07). In addition, the 0/1-hour pathway was noninferior for safety, in patients discharged, compared with the 0/3-hour pathway, absolute difference in sensitivity was +4.2% (1-sided 97.5% CI: -2.5) in favor of the 0/1-hour pathway. The calculated sensitivities were 93.7% (95% CI: 88.4%-97.1%) vs 89.5% (95% CI: 82.7%-94.3%), respectively. CONCLUSIONS: Implementation of the ESC 0/1-hour pathway failed to discharge significantly more patients within 4 hours of presentation compared with the 0/3-hour ADP. In addition, The ESC 0/1-hour was noninferior to the 0/3-hour hs-cTn pathway for safety of discharge, although safety for both pathways was less than that imputed by observational studies. This trial demonstrates that perceived benefits to emergency department efficiency of a reduced sampling interval are mitigated by central laboratory turnaround times as well as system constraints. (Pragmatic Randomised Trial of the ESC 0/​1 Versus 0/​3 Hour Troponin Pathway [MACROS2]; NCT05322395).
Explore related subjects
Keep this discovery
James Hatherley, Ahmed Dakshi, Paul Collinson, Guy Miller, Lisa Bailey, Sarah Davies, Hannah Fearon, Nirmol Meah, Freddy Frost, Ray Raj, Elizabeth Ensor, Michael Fisher, Christopher Goulden, Zaid Noori, Thomas Salmon, Anju Rawat, Rachel Hornby, Angela Lambert, Katarszyna Sekulska, Tanya Ingram, Gail Fitzgerald, Matthew Shaw, Aleem Khand. 2026-05-20. Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice: A Randomized Trial of 0/1-Hour vs 0/3-Hour Troponin Testing.. https://doi.org/10.1016/j.jacc.2026.02.5135
Cite the original work for its findings. Save a collection to share your selection of sources.
Discover connections
Connections use source metadata and explicit phrase matches, not verified experimental comparisons.