Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

Abstract

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha™ (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut™ (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut™ (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut™ (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade™ (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80 g/min (95% confidence interval [CI] 6.26-9.34 g/min) for Piranha, 4.70 g/min (95% CI 3.61-5.79 g/min) for VersaCut, 5.90 g/min (95% CI 3.16-8.64 g/min) for DrillCut, and 9.59 g/min (95% CI 4.78-14.39 g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75 g/min; 95% CI -4.58 to -0.92 g/min; P = 0.003), with an even greater difference in prostates >70 mL (-4.34 g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Explore related subjects

Keep this discovery

BibTeXRIS

Stessy Kutchukian, Pietro Scilipoti, Mikael Abi Abdallah, Astrid La Rosa, Tristan Filler, Frédéric Panthier, Marie Chicaud, Stefano Moretto, Steeve Doizi. 2026-07-08. Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.. https://doi.org/10.1111/bju.70362

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Comparison of posterior cellular bonegraft options for single-level lumbar spinal fusion: a randomized trial.

BACKGROUND: Iliac bone autograft (IBG) is osteoinductive/osteogenic/osteoconductive but requires an additional harvesting procedure with known morbidities. Bone morphogenic protein (BMP) is osteoinductive and effective in obtaining fusion but is used off label for posterior fusion, has multiple side effects, and is expensive. Stem cell bone products, both auto- and allograft are attractive osteoinductive alternatives that avoid morbidity related to the graft donor site and may have a better safety profile than BMP. Morcelized allograft bone is osteoconductive but not osteoinductive or osteogenic. PURPOSE: Evaluate and compare the effectiveness of 6 types of viable or osteoinductive bone graft material in obtaining a solid posterior spinal fusion (PSF) for single level anterior/posterior lumbar spinal fusion. The bone grafts were IBG, BMP, autogenous stem cells (MSC) from concentrated bone marrow aspirate (BMA), allograft MSC from bone marrow, adipose tissue, or amniotic fluid, combined with inert cancellous allograft (Allo). STUDY DESIGN/SETTING: Prospective, single-blinded randomized study of 6 cohorts and inert historical control. PATIENT SAMPLE: Elective anterior-posterior lumbar spinal fusion of 175 patients. OUTCOME MEASURES: Assessments included pre and postoperative back and leg pain (VAS) scores, pain drawing, disability (ODI) scores, pain medication usage, and 1-year postoperative thin-cut CT scans (read by blinded radiologists). METHODS: Patients who were surgical candidates for a 1-level anterior/posterior lumbar fusion were randomized to 1 of 6 types of posterior bone graft alternatives: IBG, BMP, BMA, allograft MSC derived from bone marrow combined with morcelized Allo (cAlloBone), adipose derived MSC combined with morcelized Allo (cAlloFat), or amnion derived MSC combined with morcelized Allo (cAlloAm). Historical Allo patients served as a negative control group. Each group (n 27) had prospective outcomes and were followed for a minimum of 2 years. Fusion rate and outcomes were compared and referenced to Allo group. RESULTS: All but 5 patients had a solid ASF. The posterior fusion rates were 98% for IBG, 94% for BMP, 85% for BMA, 67% for cAlloBone, 64% for cAlloFat, 62% for cAlloAm, and 50% for Allo. Outcomes were significantly improved for all measures for all groups and there was no difference between groups except cAlloFat had slightly greater improvement in back pain in the 7-12 month follow-up period. BMP was the most expensive graft material; cellular allografts had a high-cost relative to fusion rate. CONCLUSIONS: For single level ASF/PSF, the PSF fusion rate was significantly greater for IBG and BMP followed by BMA. Various allograft MSC bone graft options resulted in lower fusion rates but may be greater than Allo. Outcomes were uniformly improved regardless of the type of graft used or the fusion status of the posterior fusion as long as the interbody fusion was solid. If bone graft cost savings is a consideration for PSF, then IBG has the greatest radiographic value, and Allo the greatest clinical value as long as the anterior interbody fusion is solid.

Humans

Association between seminal and serum iron parameters and male infertility: a systematic review and meta-analysis.

BACKGROUND: Iron is an essential trace element for normal spermatogenesis, yet excessive iron accumulation may impair male fertility. Preliminary studies imply a link between elevated iron levels and male infertility, but evidence remains limited without systematic quantitative synthesis. This metaanalysis assessed the association between iron concentrations and male infertility. METHODS: We systematically searched PubMed, CBM, CNKI and Cochrane Library. RevMan, Stata and R were used for data analysis. Randomeffects models pooled effect sizes, with forest and funnel plots generated to evaluate seminal and serum iron levels in male infertility. RESULTS: After screening studies published up to April 2025, a total of ten eligible articles involving 985 participants were finally included in this meta-analysis. Pooled results revealed that seminal and serum iron concentrations were notably higher in infertile males compared with fertile controls. Specifically, infertile men presented higher seminal iron levels (SMD&#x2009;=&#x2009;0.44, 95% CI: 0.12-0.76, P&#x2009;<&#x2009;0.05), as well as elevated serum iron levels (SMD&#x2009;=&#x2009;3.77, 95% CI: 1.68-5.87, P&#x2009;<&#x2009;0.05). The present results suggest that increased seminal and serum iron concentrations may be potentially correlated with male infertility risk.

Humans

Opposite metabolic and gut responses to oral glutamine in male and female mice with diet-induced obesity.

Obesity is often associated with sex-dependent metabolic complications, to which altered intestinal barrier function and gut microbiota contribute. Glutamine supplementation has previously shown beneficial effects on gut barrier function and glycemic control. We thus aimed to characterize, in male and female mice, the effects of oral glutamine supplementation during high-fat-diet-induced obesity. Male and female C57BL/6 mice received a standard (SD) or high-fat diet (HFD; 60 % kcal from fat) for 14&#xa0;weeks (W14). From W12 onward, mice received glutamine in drinking water (2&#xa0;g/kg/day) or no supplementation. Body composition, glucose tolerance, insulin sensitivity, intestinal permeability, colonic inflammatory response, cecal microbiota and inflammatory/endocrine adipose response were assessed. In both male and female mice, glutamine supplementation failed to improve body weight and body composition. However, glutamine reduced glucose intolerance in HFD-fed males (AUC reduced by 14.57 %) that was associated with a partial restoration of plasma resistin and insulin and a trend toward limiting adipose inflammatory response. In males, glutamine did not affect gut microbiota composition and colonic response. Conversely, in HFD-fed females, glutamine supplementation led to gut microbiota changes (increase in Bacteroidota and Pseudomonadota phyla; increase in Muribaculaceae and Tannerellaceae families), increased colonic inflammatory markers (Il1b, Tlr4, Myd88, Irf3), increased inflammatory response in subcutaneous adipose tissue and increased HOMA-IR. Finally, HFD-fed mice exhibited sex-specific responses to glutamine supplementation with protective effects in males and harmful effects in females that need to be further deeply explored.

Animals