Search PubMedSearch

SEARCH · Search PubMed

Results for “Enrofloxacin detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

220 records · Page 3Linked to original sources

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

Non-destructive prediction of lead content in oilseed rape leaves by fluorescence hyperspectral technology based on neural network.

Based on fluorescence hyperspectral imaging (FHSI), this study targeted rapid, non-destructive quantification of lead (Pb) content in oilseed rape leaves treated with varying silicon (Si) concentrations, acquiring fluorescence spectra over the 484.43-1001.61&#xa0;nm wavelength range. To optimize spectral data quality, preprocessing methods (Savitzky-Golay smoothing, first derivative, detrending) were comprehensively compared. Characteristic wavelengths were then selected via interval variable iterative shrinkage, which effectively compressed data dimensionality and reduced computational load. A hybrid SE-CL1DA model, fusing a 1D convolutional neural network, a long short-term memory network and SE attention mechanism was constructed, with Bayesian optimization tuning hyperparameters to boost stability. The BO-SE-CL1DA outperformed both traditional machine learning and insufficiently optimized deep learning model (Rp2=0.9609, RMSE&#xa0;=&#xa0;0.0377&#xa0;mg/kg, RPD&#xa0;=&#xa0;5.1736), thus enabling accurate Pb estimation, supporting Si-regulated heavy metal stress management and facilitating agricultural contamination monitoring.

Plant Leaves

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Engineering bubble structures as Cas12a activators for highly sensitive monitoring of WRN helicase function.

The Werner syndrome helicase (WRN) is a critical synthetic lethal target in microsatellite instability cancers, essential for resolving complex genomic structures like replication bubbles and R-loops. However, strategies to simultaneously discriminate WRN activity on DNA versus DNA-RNA substrates in living cells are lacking. Here, we developed a structure-specific CRISPR/Cas12a biosensing strategy to visualize WRN functional activity by engineering bubble-structure probes. These probes were rationally designed to structurally mimic DNA replication bubbles and R-loop associated DNA-RNA hybrids. Upon specific unwinding by WRN, the probes release a sequestered activator strand that triggers Cas12a trans-cleavage, effectively converting the unwinding event into an amplified fluorescent signal. This assay achieves low picomolar sensitivity (LODs: 5.6-6.0 pM) and exceptional selectivity against homologous RecQ helicases. Uniquely, this strategy enables the parallel quantification of WRN activity on both substrate types, providing insights into distinct WRN-mediated pathways for resolving genomic stress. We further demonstrated the strategy's utility by visualizing endogenous WRN dynamics in living cells and profiling the efficacy of small-molecule inhibitors. This work offers a powerful molecular toolkit for dissecting WRN biology and facilitating high-throughput drug screening in targeted cancer therapy.

Werner Syndrome Helicase

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000&#xa0;ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Selective monitoring of trace-level catechin and myricetin in herbal and aqueous matrices using magnetic MIP-DSPME: Optimization via design of experiments.

A novel dispersive solid-phase microextraction approach utilizing a magnetic molecularly imprinted polymer (MMIP) integrated with HPLC-UV detection was developed for the concurrent quantification of catechin and myricetin in herbal extracts and aqueous samples. The sorbent was engineered as a core-shell nanocomposite, consisting of a selective polymer layer deposited onto Fe3O4@SiO2-APTMS magnetic nanoparticles. Dual-template imprinting using catechin and myricetin generated complementary binding cavities within the polymer framework. Experimental variables influencing extraction were systematically screened and subsequently optimized. A Plackett-Burman design was first applied to identify the most influential factors, with pH and sorption time identified as the dominant variables. These parameters were subsequently fine-tuned using a central composite design, and the optimization process was completed in only 30 experimental runs. The sorption characteristics of the imprinted sorbent (MMIP) were compared with those of its non-imprinted counterpart (MNIP). The MMIP demonstrated markedly higher maximum binding capacities (Qmax), reaching 119.3&#xa0;mg&#xa0;g-1 for myricetin and 112.1&#xa0;mg&#xa0;g-1 for catechin, whereas the corresponding values for the MNIP were 32.55 and 32.08&#xa0;mg&#xa0;g-1, respectively. Moreover, the affinity constants (KL&#xa0;=&#xa0;0.760-0.950&#xa0;L&#xa0;mg-1) were approximately 2.3-fold higher for the MMIP, confirming its stronger and more selective interactions with the target analytes. The selectivity coefficients for the targeted flavonoids relative to structurally related compounds, including ferulic acid, p-coumaric acid, melatonin, and curcumin, exceeded 3.5 for the MMIP, whereas the corresponding values for the MNIP were close to 1.1, demonstrating the high molecular recognition capability of the imprinted sorbent. Method validation demonstrated limits of detection (LODs) of 0.33-0.59&#xa0;ng&#xa0;mL-1 and limits of quantification (LOQs) of 1.10-1.96&#xa0;ng&#xa0;mL-1, and excellent linearity over the concentration range of 5.0-5500&#xa0;ng&#xa0;mL-1 (R2&#xa0;>&#xa0;0.998). The method achieved recoveries of 93.96% to 105.69% with RSDs below 5.5%, while the preconcentration factors ranged from 209 to 229. Furthermore, the sorbent retained more than 95% of its extraction efficiency after four consecutive reuse cycles and more than 80% after six cycles, demonstrating excellent stability and reusability. The proposed method was successfully applied to the analysis of six medicinal plant extracts and water samples, showing negligible matrix interference and superior sensitivity, selectivity, and operational simplicity compared with conventional solid-phase extraction methods.

Flavonoids

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

ZrO&#x2082;@C-based colorimetric/photothermal dual-mode immunosensor coupled with a novel monoclonal antibody for quantification of Aspergillus ochraceus biomass.

Aspergillus ochraceus contaminates agricultural products and produces nephrotoxic, carcinogenic ochratoxin A (OTA), posing severe food safety hazards. A dual-signal lateral flow immunochromatographic assay (dLFIA) based on ZrO&#x2082;@C nanoprobes was established for quantitative detection of A. ochraceus biomass. A novel monoclonal antibody (mAb 4B4) was prepared as the capture antibody to immobilize A. ochraceus mycelial lysate antigen on the test line, and a rabbit polyclonal antibody (pAb G2801) as the detection antibody to modify ZrO&#x2082;@C composites (synthesized via UiO-66 pyrolysis) into 200&#xa0;nm colorimetric/photothermal nanoprobes. This dLFIA achieved limits of detection of 0.164&#xa0;&#x3bc;g/mL (colorimetric) and 0.517&#xa0;&#x3bc;g/mL (photothermal). This efficient and reliable method allows quantitative analysis of A. ochraceus biomass, which is suitable for routine monitoring of fungal contamination in agro-food matrices.

Antibodies, Monoclonal

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50&#xa0;&#x3bc;M, and intracellular concentrations and cell viability were monitored over 48&#xa0;h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Applications of metal-organic frameworks in smart packaging for food freshness indication: a comprehensive review.

Smart packaging is extensively studied for its multifunctional capabilities in antimicrobial activity, preservation, and atmosphere modification. Recently emerged metal-organic frameworks (MOFs) freshness-indicating packaging becomes a key research direction in smart packaging owing to its distinctive functions and physicochemical properties. As multifunctional materials, the unique porous structure and tunable properties of MOFs provide a distinctive approach for developing food packaging applications dedicated to food freshness indication. Existing MOFs-based smart packaging still faces potential safety risks and technical challenges in practical applications, and there remains a lack of integrated discussion that combines synthesis strategies, packaging design, optimization, and safety assessment. This review elaborates on the application of MOFs in freshness-indicating smart packaging, focusing on diverse MOFs synthesis strategies, the formats of smart packaging, types of indicator signals, and qualitative/quantitative analytical methods. It also delves into the methodology concepts of MOFs-based smart packaging and evaluates MOFs safety in food packaging by addressing potential risks. Studies show that MOFs-based smart packaging achieves qualitative and semi-quantitative analysis of food freshness through multiple signal modalities such as visible color change, fluorescence, and photothermal effects. This review emphasizes that safe MOFs design is critically important and should comply with the overall migration limit of <10 mg/dm2 specified in Regulation (EC) No 1935/2004, lanthanide element limit of <0.05 mg/kg, and FDA threshold of 1.5 &#x3bc;g/person/day. Comprehensive safety assessment and intelligent sensing platforms will constitute pivotal directions for advancing MOFs-based smart packaging toward practical application.

Food Packaging

AI Health message intervention: The role of message customization and message source in breast cancer screening among women of color.

OBJECTIVES: To examine the effectiveness of breast cancer screening messages with varying levels of customization (generic, targeted, and tailored) and to compare AI-generated versus human-generated messages. METHODS: A between-subjects experimental design with a control condition was employed. Message content followed a standardized structure and varied by level of customization: generic, targeted (demographic-based), and tailored (perceived susceptibility- and barrier-based). Messages were developed by either the authors or GenAI (ChatGPT-4o). A total of 391 participants recruited via Prolific were randomly assigned to five groups (generic, targeted-human, targeted-AI, tailored-human, and tailored-AI). Self-efficacy, behavioral intentions, attitudes, and message believability were measured using different scales. RESULTS: Customized (tailoring and targeting) health messages performed comparably to generic messages in shaping positive health outcomes. GenAI-generated messages also produced outcomes comparable to those of human-generated messages under standardized conditions. Significant negative indirect effects through message believability for the human-tailored condition was found relative to the generic condition. CONCLUSIONS: GenAI may be a useful tool for developing and customizing scalable health messages. Its effectiveness depends not only on customization but also on maintaining message quality, including readability, clarity, coherence, naturalness, and credibility. PRACTICAL IMPLICATIONS: GenAI may support health practitioners in developing customized and scalable breast cancer messages. However, professional review remains necessary to ensure that the message is culturally appropriate, responsive to patient concerns, and suitable for use alongside patient-provider communication.

Humans

[Study of a patient with azoospermia due to variant of MOV10L1 gene].

OBJECTIVE: To explore the clinical and genotypic characteristics of a patient with Sertoli cell-only syndrome (SCOS) due to variants of MOV10L1 gene. METHODS: A 27-year-old patient with Non-obstructive azoospermia (NOA) underwent routine semen analysis. Serum levels of follicle-stimulating hormone (FSH), luteinizing hormone (LH), progesterone (P), estradiol (E2), prolactin (PRL), and testosterone (T) were determined by chemiluminescence assays. Peripheral blood samples were collected for G-banded karyotyping analysis. Multiplex PCR fluorescence detection was used to screen for AZF gene microdeletions. Whole exome sequencing (WES) and Sanger sequencing were performed simultaneously. Testicular biopsy tissues were subjected to Hematoxylin-Eosin (HE) staining to assess seminiferous tubule cell composition, and MOV10L1 protein expression was detected by immunohistochemical staining. Bioinformatics tools were employed to predict the pathogenicity of variants and their impact on protein structure and function. This study was approved by the Medical Ethics Committee of the Guangdong Institute of Reproductive Sciences [Ethics No.: 2023(01)]. RESULTS: The patient's two semen analyses had failed to detect any sperm. Hormone tests indicated elevated FSH (22.32 mIU/mL) and PRL (397.6 mIU/mL), while T (3.68 nmol/L) and E2 (38.32 pmol/L) were reduced. Chromosomal karyotyping revealed 46,XY, and no AZF gene deletion was detected. WES and Sanger sequencing detected compound heterozygous variants of the MOV10L1 gene, including a c.345C>A (p.C115X) nonsense variant and a c.3323C>T (p.T1108I) missense variant, with the former being unreported previously. HE staining showed only Sertoli cells in the seminiferous tubules, confirming the diagnosis of SCOS. Immunohistochemical staining revealed absent MOV10L1 protein expression in the testicular tissue. Based on the guidelines from American College of Medical Genetics and Genomics (ACMG), the c.345C>A (p.C115X) was classified as a pathogenic variant (PVS1+PM2_Supporting+PP4), while the c.3323C>T (p.T1108I) was deemed variant of uncertain significance (PM2_Supporting+PP3_Supporting+PP4). Bioinformatics analysis demonstrated that c.345C>A (p.C115X) may cause premature termination of protein translation, while c.3323C>T (p.T1108I) may disrupt the hydrophobicity of the RNA helicase domain, reducing the active pocket volume and decreasing its affinity for MILI protein. CONCLUSION: This study has diagnosed a case of SCOS due to compound heterozygous variants of the MOV10L1 gene, which also enriched its mutational spectrum.

Humans

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Candidate biomarkers for early Giardia duodenalis infection revealed by time-resolved secretome proteomics.

Giardia duodenalis is a zoonotic protozoan parasite that causes giardiasis in humans and other mammals. Early diagnosis remains challenging because current diagnostic methods, including microscopy and enzyme-linked immunosorbent assays (ELISAs), primarily detect established infections. Consequently, a critical diagnostic gap exists during the early stage of infection within the first 2-48&#xa0;h following exposure. To address this limitation, we characterized the proteins released by in vitro-cultured G. duodenalis trophozoites under serum-free conditions and evaluated their potential as early diagnostic biomarkers. Proteomic analysis of culture supernatants collected during early trophozoite incubation identified 31,773 peptides corresponding to 2504 quantifiable proteins. Temporal profiling showed distinct secretion patterns, including proteins that peaked during the early stage, progressively accumulated over time, or remained persistently abundant throughout the incubation period. Based on their secretion characteristics and predicted immunogenic properties, five candidate biomarkers were selected for further evaluation. Polyclonal antibodies raised against selected candidates successfully detected the corresponding proteins in serum-free culture supernatants, providing preliminary evidence for their potential utility as early-stage diagnostic targets. These findings identify stage-associated candidate proteins that may serve as a resource for future early giardiasis diagnostic development, provide a valuable resource for investigating host-parasite interactions, and establish a foundation for future diagnostic assay development. However, further validation in clinical and biological samples is required to confirm their diagnostic applicability. SIGNIFICANCE: Giardiasis, caused by Giardia duodenalis, is a major diarrheal disease worldwide. Although enzyme-linked immunosorbent assays (ELISAs) provide rapid detection, their diagnostic utility is limited by the lack of biomarkers capable of identifying infection during its earliest stages, creating a critical gap in the detection of active infection within 2-48&#xa0;h following exposure. Using data-independent acquisition proteomics, this study provides a time-resolved characterization of proteins released by G. duodenalis trophozoites into serum-free culture supernatants. Our findings reveal temporal secretion dynamics of protein secretion and identify candidate biomarkers with potential utility for the development of early-stage diagnostic assays pending rigorous biological and clinical validation. In addition, this proteomic resource provides a foundation for investigating host-parasite interactions and may facilitate the development of future point-of-care diagnostic strategies.

Giardiasis

A 4-year longitudinal wastewater surveillance of five gastroenteritis viruses and the correlation with clinical cases in Alberta, Canada.

Viruses are common causes of acute gastroenteritis worldwide. They are detected in large quantities in raw sewage making them amenable to wastewater-based surveillance (WBS). To monitor the prevalence of gastroenteritis viruses in wastewater and assess their correlation with clinical cases, wastewater samples collected between July 2020 and June 2024 from 12 wastewater treatment plants across Alberta, Canada were analyzed for norovirus (NoV) GI & GII, rotavirus (RoV), adenovirus (AdV), sapovirus (SaV) and astrovirus (AsV). Among the 5726 wastewater samples tested, AdV (80.5%) had the highest detection rate followed by NoV GII (75.6%), SaV (63.2%), NoV GI (59.4%), RoV (42.2%) and AsV (20.2%). Winter and spring seasonality was found for NoV and RoV in both wastewater and clinical disease. Public health interventions especially in the 1st year of the COVID-19 pandemic had a significant impact on their burden with marked reduction in wastewater detected viruses and clinical cases. NoV showed a strong correlation between its level in wastewater and the number of clinical cases, while moderate correlation was observed for the other four viruses. Cross-correlation analysis showed that changes of viral RNA concentration in wastewater lagged behind reported gastroenteritis cases by approximately 6&#xa0;days to 3&#xa0;weeks. To our knowledge, this is the longest multi-region WBS study monitoring multiple gastroenteritis viruses spanning both COVID-19 pandemic and post-pandemic periods. The data obtained from this study supported WBS as a complementary tool to track population-based circulation of gastroenteritis viruses, providing actionable public health data.

Clinical cases

Comprehensive source-risk assessment of organophosphate esters in surface water of the Dianchi Lake Basin, Yunnan, China.

Organophosphate esters (OPEs), widely used as flame retardants and plasticizers, have been increasingly detected in aquatic environments. However, investigations of their distribution in high-altitude plateau lakes remain scarce. Identifying and quantifying the sources and associated risks of OPEs are crucial for subsequent water environment management. In this study, an integrated source-risk analysis approach was employed by combining the Positive Matrix Factorization (PMF) model, the Geodetector (GD) model, and risk quotient (RQ). Analysis of 14 OPEs in surface waters of the Dianchi Lake Basin (DLB) revealed 12 detectable compounds, with total OPEs concentrations (&#x3a3;OPEs) ranging from not detected (ND)-64.6 ng/L during the wet season and ND-35.8 ng/L during the dry season. Elevated &#x3a3;OPEs were primarily observed at inflow sites in the northern part of the lake and in urban rivers. Source apportionment indicated four major contributing sources: agricultural films containing flame-retardant and plasticizer additives, traffic-related particulate emissions, releases from household and personal care products, and industrial production and applications of flame retardants in plastics, electronics, and related products (the predominant source). The ecological impact caused by OPEs ranges from no risk to low risk, with tris(2-chloroethyl) phosphate emitted from industrial source being the primary driver of potential environmental risk. These findings highlight the necessity of prioritizing industrial sources in future management strategies. Overall, this study provides a methodological framework for source apportionment and risk assessment of OPEs and offers scientific evidence to support environmental management of OPEs in the DLB.

Environmental Monitoring