Search PubMedSearch

SEARCH · Search PubMed

Results for “Cell Culture Techniques, Three Dimensional”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,127 records · Page 2Linked to original sources

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of ∼0.47 fM and a quantitative range of 1 fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8 ± 2.3 nm for Cy5 and 13.5 ± 2.9 nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28 nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Assessment of temporomandibular joint space changes after orthognathic surgery in skeletal malocclusion patients: a systematic review.

PURPOSE: To interpret postoperative changes in temporomandibular joint (TMJ) joint space dimensions and condylar position following orthognathic surgery in patients with skeletal malocclusions, and to determine whether reported alterations represent clinically meaningful displacement or physiological adaptive remodeling. MATERIALS AND METHODS: A comprehensive search of PubMed, SCOPUS, Web of Science, EBSCOhost, and Cochrane Library was performed to assess pre- and postoperative TMJ changes using three-dimensional imaging. Joint spaces including anterior (AJS), superior (SJS), and posterior (PJS) and condylar morphology were evaluated. Methodological quality was appraised using the Joanna Briggs Institute (JBI) checklist. Due to methodological and clinical heterogeneity, findings were synthesized narratively with attention to malocclusion type and surgical movement. RESULTS: A total of 16 studies consisting 628 patients undergoing BSSO, Le Fort I osteotomy, vertical ramus osteotomy, or bimaxillary surgery were included. Most studies reported minor, adaptive postoperative changes in AJS, SJS, and PJS. Class II patients showed more consistent increases in AJS/SJS, whereas Class III patients demonstrated variable posterior or anterior remodelling depending on surgical movement. Volumetric analyses revealed region-specific adaptations without significant condylar displacement. Postoperative temporomandibular disorder symptoms were infrequent, and no consistent evidence supported detrimental TMJ effects attributable to surgery. CONCLUSION: Postoperative TMJ joint space changes after orthognathic surgery primarily represent physiological adaptive remodeling rather than pathological condylar displacement, with reported variability driven by malocclusion type, surgical movement, fixation method, and imaging protocol. Recognizing these predictable patterns is essential to prevent overinterpretation of postoperative imaging and to improve clinical assessment through standardized three-dimensional and long-term evaluation strategies.

Humans

Analysis of deep learning techniques in computer-aided diagnosis for meniscus injuries: a systematic literature review.

Meniscus informatics is a growing subject of study in the healthcare industry. One of the major hindrances to the healthcare system's transformation is obtaining knowledge and meaningful information from complicated, high-dimensional and diverse sources. Modern biomedical research, for instance, has seen an increase in the use of complex, dissimilar, poorly documented, and generally unstructured electronic health records, imaging, sensor data and text, even after many current techniques have been used to extract more robust and useful elements from the data for analysis. New efficient standards for building end-to-end learning models from complex data are therefore needed. Therefore, the current study aims to examine the most recent research on the use of deep learning techniques for diagnosing meniscus tears and recommend creating comprehensive and meaningful interpretable structures that might benefit the healthcare industry. We also draw attention to shortcomings and the need for better technique development, and we provide new perspectives about this exciting new development in the field.

Humans

Diagnostic value of plasma cell-free DNA metagenomic next-generation sequencing in patients with suspected infections and exploration of clinical scenarios-a retrospective study from a single center.

BACKGROUND: Plasma cell-free DNA metagenomic next-generation sequencing (mNGS) is a non-invasive comprehensive method for the etiological diagnosis of various infectious diseases. However, research on the early diagnosis and real-world clinical impact of plasma mNGS in patients with suspected infection are still limited. MATERIALS AND METHODS: This study retrospectively included 140 patients with suspected infections who underwent early plasma mNGS and conventional culture testing. Referring to the clinical diagnosis of infectious diseases, the diagnostic performance of plasma mNGS and culture tests was compared, and the application scenarios and clinical effects of plasma mNGS were evaluated. RESULTS: The positive rate of plasma mNGS was significantly higher than that of culture methods (55.71% vs 25.10%, p&#x2009;<&#x2009;0.001) and blood cultures (55.71% vs 12.86%, p&#x2009;<&#x2009;0.001). Regarding clinical diagnosis, the sensitivity of plasma mNGS was significantly higher than that of culture (58.27% vs 37.80%, p&#x2009;=&#x2009;0.002). The combination of mNGS and culture achieved a higher detection sensitivity (69.29%), especially in patients with multi-site co-infections (73.68%) and blood infections (73.17%). Plasma mNGS demonstrated higher sensitivity in patients with procalcitonin (PCT) index > 5&#x2009;ng/ml or human neutrophil lipocalin (HNL) index > 200&#x2009;ng/ml. In terms of treatment, a total of 69 patients (54.33%) benefited from plasma mNGS. CONCLUSION: This study highlights the significant improvement in pathogen detection performance by combining conventional culture with plasma mNGS detection, especially in patients with multi-site co-infections and blood infections. Early use of plasma mNGS as an adjunct to culture can better guide clinicians to initiate appropriate anti-infective therapy.

Humans

Community-driven advances in computational mass spectrometry: The perspective of EuBIC-MS members.

Advances in data acquisition, artificial intelligence, and integrative bioinformatics are driving the rapid evolution of computational mass spectrometry, and in turn, transforming modern proteomics, metabolomics, and lipidomics. These developments have greatly increased the scale and complexity of mass spectrometry data, underscoring the importance of evolving accurate, transparent, efficient and reproducible data processing workflows. Addressing these challenges requires collaborative innovation that brings together expertise in software engineering, statistics, and biology. The European Bioinformatics Community for Mass Spectrometry (EuBIC-MS), an initiative of the European Proteomics Association (EuPA), fosters a culture of open, community-driven development through its biennial Developers Meetings and Winter Schools. This commentary summarizes the scientific background and outcomes of the EuBIC-MS Developers Meeting 2025, which took place in Novacella, Italy. Three keynote presentations highlighted major frontiers in the field: deep proteome and phosphoproteome profiling, text mining for protein-protein interaction extraction, and scalable proteomics for AI-driven drug discovery. Seven community-selected hackathons addressed emerging challenges such as single-cell proteomics data analysis, FAIR metadata extraction, deep learning frameworks, R-Python interoperability, and DIA validation. Together, these efforts demonstrate the potential for scientific and technical innovation to arise from open collaboration, and highlight how community-driven initiatives can accelerate progress in computational mass spectrometry. SIGNIFICANCE: Modern proteomics increasingly depends on computational advances to translate complex, high-dimensional data into biological knowledge. The EuBIC-MS Developers Meeting 2025 exemplifies how community-driven collaboration can directly accelerate this process by bringing together experts from bioinformatics, statistics, and experimental proteomics to co-develop open, interoperable, and reproducible analytical tools. By fostering shared software frameworks, transparent benchmarking, and collaborative problem solving, the EuBIC-MS community helps ensure that technological innovation translates into reliable biological insights. This collaborative model strengthens the foundation for quantitative, system-level understanding of proteomes and establishes a sustainable path for integrating artificial intelligence and next-generation data acquisition into routine biological discovery. This commentary shows some current highlights in the field of computational mass spectrometry and community-based approaches undertaken during the most recent Developers Meeting to solve these challenges. The approaches discussed and initiated during the meeting - ranging from deep proteome profiling and phosphosite mapping to text mining, single-cell data analysis, and FAIR metadata extraction - address key bottlenecks that currently limit the biological interpretability and comparability of proteomics data.

Mass Spectrometry

Current Concepts and Emerging Technologies in Aesthetic Outcome Assessment of Breast Reconstruction.

Aesthetic outcomes are a crucial determinant of the overall success of breast reconstruction. Recently, aesthetic assessment has evolved from relying mainly on subjective impressions to incorporating more quantitative methods. This systematic review summarizes current concepts and emerging technologies in aesthetic outcome assessment after breast reconstruction. A comprehensive search of studies evaluating aesthetic outcomes following implant-based, autologous or hybrid breast reconstruction was performed between 2000 and 2025. Assessments were classified as subjective or objective. Extracted variables included assessment characteristics, aesthetic outcome domains, and patient-centered outcomes. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist. Levels of evidence were classified according to the Oxford Centre for Evidence-Based Medicine. A total of 51 studies involving 7711 participants from 16 countries were included. Subjective tools were most frequently employed, led by the BREAST-Q (35/51, 69%), followed by expert- or panel-based evaluations (17/51, 33%) and the visual analog scale (2/51, 4%). Objective methods were applied in 19 studies and included 3-dimensional surface imaging (8/51, 16%), BCCT.core (7/51, 14%), eye tracking (3/51, 6%), and artificial intelligence-based analyses (3/51, 6%). Although subjective tools captured satisfaction with breast appearance, objective tools quantified morphological parameters and positional landmarks. BREAST-Q remains the cornerstone of outcome evaluation after breast reconstruction, providing patient-centered perspectives, including, but not limited to, aesthetic perception. A progressive shift toward multimodal evaluation was noticed, as no single modality comprehensively addressed all aesthetic domains. Future research should focus on integrating subjective and objective assessment methods within a unified framework. Level of Evidence: 3 (Therapeutic) For image description, please refer to the figure legend and surrounding text.

Humans

Exploring the Diagnostic Utility of Ferumoxytol for Brachial Plexus MR Neurography.

Background Ferumoxytol has been described as an alternative contrast agent for vascular suppression in MR neurography (MRN), but its diagnostic utility in patients has yet to be evaluated. Purpose To evaluate the impact of ferumoxytol on vascular suppression, nerve conspicuity, and evaluation of nerve abnormalities at three-dimensional (3D) brachial plexus MRN, compared with noncontrast and gadolinium-enhanced MRN, in participants with suspected Parsonage-Turner syndrome (PTS) or thoracic outlet syndrome (TOS). Materials and Methods This prospective study included participants who underwent 3D MRN with and/or without gadolinium chelate for clinical suspicion of PTS or TOS and subsequently underwent 3D MRN with ferumoxytol (within 3 months of the clinical examination). Two musculoskeletal radiologists qualitatively evaluated 3D short-tau inversion-recovery fast spin-echo scans for the degree of vascular suppression, nerve conspicuity, and presence of nerve abnormalities. Wilcoxon signed-rank or McNemar tests were used for comparing noncontrast and gadolinium-enhanced scans with ferumoxytol-enhanced scans. Results This study included 18 participants (mean age, 42 years &#xb1; 15.2 [SD]; 10 men). Ferumoxytol-enhanced scans demonstrated improved vascular suppression compared with both noncontrast scans (both raters, P < .001) and gadolinium-enhanced scans (both P = .04). For rater 2, ferumoxytol-enhanced acquisitions demonstrated improved conspicuity of several nerve segments relative to the noncontrast scan, including segments of the suprascapular (P = .01), axillary (P = .02), and long thoracic nerves (P = .004). The distribution of scores for these nerve segments for rater 1 also favored ferumoxytol-enhanced versus noncontrast scans, but the differences were not statistically significant (all P &#x2265; .06). There was no evidence of a difference in nerve conspicuity between ferumoxytol-enhanced and gadolinium-enhanced scans (P &#x2265; .17 for all nerve segments) and also no evidence of discrepancies in abnormal nerve findings between the acquisitions (all P &#x2265; .48). Conclusion Ferumoxytol improved vascular suppression compared with noncontrast and gadolinium-enhanced 3D short-tau inversion-recovery fast spin-echo sequences in brachial plexus MRN, enhancing the conspicuity of several nerve branches versus noncontrast scans, with similar detection of abnormal nerve findings. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Suppression of HIV-1 replication in CEM-A cell cultures by trans-splicing group I introns targeting PAS/PBS sequences and conditionally expressing &#x394;N-Bax.

Anti-HIV group I introns containing antisense guide sequences directed against the HIV-1 primer activation signal and primer-binding site (PAS/PBS) were designed and evaluated. Because PAS/PBS sequences are present in the viral RNA species examined, these RNAs can serve as trans-splicing substrates. The introns were active against both artificial target RNAs and viral RNA generated during infection. Cleavage and degradation of targeted viral RNA may have contributed to suppression, whereas inclusion of a 3' exon encoding the proapoptotic protein &#x394;N-Bax was associated with increased programmed cell death and may have augmented suppression of viral replication. In cultured CEM-A cells, transgene expression of these introns markedly suppressed HIV-1 replication, with p24 levels falling below the assay detection limit in selected clones. RESULTS: RT-PCR and sequence analysis detected splice products containing the expected PAS/PBS junctions. In the dual-luciferase assay, intron expression reduced normalized Gaussia luciferase signal by approximately 70% relative to the negative control. Qualitative Annexin V imaging and caspase-3 assays were consistent with infection-dependent apoptosis after &#x394;N-Bax splice-product formation. Transient expression of each intron in HEK293T cells followed by infection with VSV-G-pseudotyped HIV-1NL4-3&#x202f;at an MOI of 2 reduced p24 levels by approximately 50% at 4 days post-infection. Construct 128L produced the strongest RT-PCR band under the tested conditions and was selected for subsequent experiments. A canonical splice product and a low-abundance noncanonical splice product were detected; both involved the intended HIV-derived target RNA, although transcriptome-wide off-target splicing was not assessed. Heterogeneous transformed HEK293T populations showed an approximately 2-log10 reduction in p24. In selected clonal HEK293T and CEM-A lines, p24 was below the assay detection limit at the measured endpoints, including up to 90 days after infection in some CEM-A clones. CONCLUSIONS: PAS/PBS-targeting group I introns suppressed HIV-1-associated p24 production in the tested cell-culture models. Linking the introns to a &#x394;N-Bax 3' exon was associated with infection-dependent apoptosis and may further limit viral replication and spread. The use of highly conserved, functionally constrained target sequences may reduce the likelihood of escape, but viral evolution and transcriptome-wide off-target effects were not assessed. This conditional death-upon-infection strategy warrants further evaluation in primary-cell and in vivo models.

Humans

Microbial signal profiles and organism-level concordance between plasma metagenomic sequencing and blood culture in suspected bloodstream infection.

Plasma metagenomic next-generation sequencing (mNGS) and blood culture detect different components of the microbial signal and frequently produce discordant organism reports. We characterized microbial signal class, report-derived burden, organism-level concordance, and independent clinical attribution in a retrospective, single-center, episode-level cohort. Among 329 episodes with evaluable plasma mNGS reports, 315 had blood culture performed; 232 were mNGS positive/culture negative and 53 were positive by both methods. In the 232 discordant episodes, the recorded routine-care diagnosis classified 124 as bloodstream infection (BSI) and 108 as non-BSI. Nonviral signals were present in 78.2% and 42.6%, respectively (P&#x2009;<&#x2009;0.001), and median maximum report-derived sequence counts were 98.5 and 11.5 (P&#x2009;<&#x2009;0.001). Two laboratory physicians then independently reviewed source records using structured criteria while masked to the recorded BSI label and mNGS organism and sequence-count information. Initial agreement for the five-category BSI assessment was 97.6% (Cohen's kappa, 0.960). Within the mNGS-positive/culture-negative subgroup, adjudicated BSI likelihood showed a modest ordinal association with report burden (Spearman rho&#x2009;=&#x2009;0.190; P&#x2009;=&#x2009;0.004), while mNGS organisms were considered supported in 1 episode, plausible in 158, unlikely or contaminant in 72, and unresolved in 1. Among 53 dual-positive episodes, 33 (62.3%) shared at least one species, but only 5 (9.4%) had complete species-set concordance. Plasma mNGS and blood culture therefore frequently generated non-equivalent organism sets. Signal class and report burden contributed graded contextual evidence, but organism-level attribution required clinical review and orthogonal microbiology rather than binary positivity alone.

Humans

Coupling of spectroscopy and nitrogen-oxygen isotopes unveils the mechanisms of dissolved organic matter and nitrate pollution in lakes within the agro-pastoral transition zone.

Lakes in arid and semi-arid regions are subjected to severe ecological stress, such as organic pollution, eutrophication, and salinization, due to climate change and human activities. This study investigates Chagannur Lake, a typical arid-region lake that is representative and ecologically sensitive in Northern China's agro-pastoral ecotone, to uncover its pollution characteristics and mechanisms. We employed fluorescence spectroscopy and stable isotope analysis to trace dissolved organic matter (DOM) and nitrate sources. The DOM composition was dominated by microbial metabolic byproducts and protein-like substances, suggesting that microbial processes are key to organic matter transformation. Source apportionment revealed that pollutants primarily originated from livestock and poultry manure (37.6 %), agricultural fertilizers (35.6 %), and soil erosion (24.7 %), with agricultural fertilizers contributing most significantly in the Gogstai River (63.3 %). A structural equation model (SEM) coupling spectral and mass spectrometric data revealed that microbial transformation significantly impairs the lake's self-purification capacity, thereby promoting pollutant accumulation (path coefficient = 0.91,*p < 0.05). Moreover, microbial processes link endogenous and exogenous pollution, a mechanism effectively traced by isotopic and fluorescence indices (path coefficient = 0.55, &#x204e;&#x204e;p < 0.01). These findings enhance the understanding of pollution sources and transformation mechanisms in arid-region lakes and offer foundational theoretical support for policymakers engaged in pollution control strategies.

Lakes

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans

Retrosigmoid craniotomy surgical guide: The way forward for precise exposure of the transverse-sigmoid sinuses.

INTRODUCTION: The retrosigmoid craniotomy is the workhorse approach to the cerebellopontine angle. Accurate localisation of the transverse-sigmoid junction (TSJ) is key for optimised exposure and cerebellar retraction. Various methods, both anatomical and navigational, have been used but with suboptimal results. We utilised a 3D-printed retrosigmoid surgical guide in an attempt to overcome this and report our early outcomes and experiences in the design, production and utilisation of the guide. METHODS: This is a prospective cohort study of the patients with retrosigmoid craniotomies performed using the surgical guides. Patient demographics and diagnoses, along with the accuracy of the planned burrhole and craniotomy, need for craniotomy extension, presence of venous sinus injury, set-up time, and cost were reported. RESULTS: There were ten cerebellopontine angle cases in which the surgical guides were utilised, three petrous meningiomas, two trigeminal neuralgias, two metastasis, and three other tumours. The planned burrhole and craniotomy were precise in all cases with accurate exposure of the TSJ and no requirement for craniotomy extension. The mean set up time was 3.9&#xa0;min, and the mean cost of the surgical guides was USD 470.90. One elderly patient had an intraoperative transverse sinus injury related to adherent dura that was planned for exposure. CONCLUSION: The 3D-printed surgical guide is a potential solution to the rapid, precise and consistent identification of the TSJ when performing a retrosigmoid craniotomy. We present our early experience and discuss nuances in the designing, production, and intraoperative phases to optimise the precision of this guide. We suggest two methods to avoid sinus injury in elderly patients: either to plan the craniotomy to the edge of the sinus, or to plan sinus exposure but to use burr drills rather than the osteotome, as in our case, to expose the sinus.

Humans

Walking Together: A Cross-Cultural Study of the Relationship Between Religiosity and Substance Use Disorder.

The literature suggests that religiosity is a protective factor for substance use. However, individuals with substance use disorder (SUD) may actively cultivate their religiosity during substance use. This qualitative study analyzed the perceptions and meanings homeless people attribute to their substance use trajectories and religiosity, as well as the potential connections between these two themes. The analysis was conducted based on the content analysis technique proposed by Bardin. A total of 40 semi-structured interviews were conducted with 20 Brazilian and 20 Portuguese participants. The present study found that religiosity can play a role in the substance use trajectory and the development of SUD by offering a subjective sense of protection, serving as a marker for the need for change, or providing relief from the suffering associated with SUD. We discuss how homeless people with SUD experience religiosity and how religious aspects traditionally seen as protective in the literature, such as church attendance, may paradoxically become risk factors for these socially vulnerable populations.

Humans

Effects of umbilical cord mesenchymal stem cell-derived exosomes on periodontal ligament stem cells: An exploratory study.

OBJECTIVE: To investigate whether exosomes derived from human umbilical cord mesenchymal stem cells (UCMSCs) at two osteogenic induction stages (undifferentiated and late-stage) differentially affect periodontal ligament stem cells (PDLSCs), and to explore the potential molecular basis. DESIGN: UCMSCs and PDLSCs were isolated and cultured. Exosomes were harvested from undifferentiated UCMSCs (Exo-D0) and UCMSCs after 14 days of osteogenic induction (Exo-D14). PDLSCs were treated with both exosome types. Proliferation and migration were analyzed using EdU and scratch assays, the latter under serum-free conditions. Early osteogenic differentiation was assessed by alkaline phosphatase staining and quantitative reverse transcription PCR (qRT-PCR). Differentially expressed miRNAs were identified by high-throughput sequencing and further analyzed through Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analyses. RESULTS: Both exosome types promoted PDLSC migration. Exo-D0 enhanced early osteogenic differentiation, whereas Exo-D14 enhanced proliferation but reduced early osteogenic marker expression. Sequencing identified 21 differentially expressed miRNAs (13 upregulated, 8 downregulated). Bioinformatic prediction suggested that the putative target genes were enriched in Ras signal transduction, regulation of kinase activity, and focal adhesion, and further predicted significant enrichment in the MAPK, Ras, and PI3K-Akt signaling pathways, which are central to cell proliferation and osteogenic differentiation. CONCLUSIONS: Exosomes from undifferentiated and osteogenically induced UCMSCs exerted distinct effects on PDLSCs, potentially associated with differentially packaged miRNAs. These findings offer a basis for hypotheses about exosome-mediated mechanisms and support matching exosome sources to the intended therapeutic outcome as potential cell-free strategies for periodontal tissue regeneration and alveolar bone repair.

Humans

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans