Search PubMedSearch

PubMed · 42626956

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

Abstract

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Explore related subjects

Keep this discovery

BibTeXRIS

Paraskevas Filippidis, Céline El Khoury, Mario Cruciani, Alexandre Alanio, Rosemary A Barnes, Ralf Bialek, Maria Jose Buitrago, J Peter Donnelly, Raphael Grolimund, Ferry Hagen, Catriona Halliday, Elizabeth Johnson, Martina Lengerova, Jurgen Loeffler, Willem J G Melchers, Carlo Mengoli, Lily Novak-Frazer, Onya Opota, Melinda Paholcsek, Thomas F Patterson, Riina Rautemaa-Richardson, Volker Rickerts, Markus Ruhnke, Lena Tschiderer, Alexia Cavin-Trombert, Birgit Willinger, P Lewis White, Frederic Lamoth. 2026-08-21. Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).. https://doi.org/10.1128/jcm.00721-26

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Enhancing Hemoglobin Bart's hydrops fetalis syndrome prevention: a single-tube multiplex real-time PCR assay for the comprehensive detection of four significant α0-thalassemia deletions (--SEA, --THAI, --CR, and --SA) found in Thailand.

BACKGROUND: Hemoglobin (Hb) Bart's hydrops fetalis is a major public health concern in Southeast Asia, particularly in Thailand. Current screening strategies target the two most common α0 -thalassemia deletions (--SEA and --THAI). METHOD: In this study, we developed a single-tube multiplex real-time PCR assay for the simultaneous detection of four clinically relevant α0-thalassemia deletions (--SEA, --THAI, --CR, and --SA). The assay was validated using 538 clinical samples with diverse thalassemia genotypes and compared against conventional gap-PCR as the reference method. Analytical performance, including sensitivity, specificity, and limit of detection (LOD), was evaluated. In addition, clinical utility was assessed in 22 prenatal diagnosis cases at risk of Hb Bart's hydrops fetalis. RESULTS: The study cohort demonstrated substantial genetic heterogeneity, comprising 43 distinct genotypes. The developed assay achieved 100% sensitivity and specificity for all targeted deletions, with complete concordance with gap-PCR results. No cross-reactivity was observed with α+-thalassemia. The assay demonstrated a high analytical sensitivity with a LOD of 9.76 × 10-3 ng per reaction. Whereas in prenatal diagnosis, all 22 fetal genotypes were accurately identified, including five cases of homozygous --SEA and one rare compound heterozygous --SEA/--CR fetus. CONCLUSIONS: This study presents a rapid, accurate, and cost-effective multiplex real-time PCR assay capable of detecting both common and rare α0-thalassemia deletions in a single reaction. The assay demonstrates strong potential for implementation in routine clinical laboratories and large-scale population screening, contributing to improved prevention and control of severe thalassemia syndromes in high-prevalence regions.

Humans

Evaluation of one-step amplicon-based targeted enrichment for SARS-CoV-2 whole-genome sequencing using the Midnight amplicon scheme.

Genomic surveillance proved invaluable during the COVID-19 pandemic for tracking SARS-CoV-2 variants and guiding outbreak responses, underscoring the ongoing need to reduce whole-genome sequencing (WGS) costs and improve workflow efficiency to ensure accessibility in resource limited settings. Here, we evaluated a one-step reverse transcription polymerase chain reaction (RT-PCR) approach using the Midnight V2 primer scheme for targeted amplification of the SARS-CoV-2 genome, assessed its compatibility with Illumina sequencing, and compared its performance to a well-established two-step method. Initially, we determined optimal RT-PCR reaction conditions using the Midnight V2 primer panel for the one-step RT-PCR kit and scaled reaction volumes for both RT-PCR and library preparation. Clinical specimens (n = 53) that had undergone routine WGS for surveillance purposes using the established two-step RT-PCR method were compared using the one-step RT-PCR assay. For samples with genome completeness greater than 70%, both methods gave comparable results with similar sequence coverage and 100% concordance for lineage assignment. Further investigation revealed a higher percentage of reads aligning to the SARS-CoV-2 genome with a greater depth of coverage using the one-step method compared to the two-step method. Finally, analysis of scaled one-step and library reaction volumes revealed significant cost savings for samples undergoing WGS. Overall, the results presented here verify the accuracy and reproducibility of one-step targeted amplification and offer an efficient and cost-effective workflow for routine SARS-CoV-2 genomic surveillance.

Humans

Diagnostic utility of high-risk HPV polymerase chain reaction-based testing in head and neck FNA specimens with indeterminate cytomorphology.

BACKGROUND: Fine-needle aspiration (FNA) is critical in the initial diagnosis of many high-risk human papillomavirus (HR-HPV)-associated, metastatic oropharyngeal squamous cell carcinomas. Updated guidelines recommend HR-HPV-specific polymerase chain reaction (PCR) analysis over p16 immunohistochemistry on FNA specimens because p16 performs poorly on cytology material. PCR-based assays on liquid cytology material have demonstrated excellent analytic performance; however, the diagnostic utility of a positive HR-HPV PCR result in specimens with indeterminate cytomorphology remains uncharacterized. METHODS: The authors retrospectively identified 279 head and neck FNA specimens that had paired HR-HPV PCR testing on residual liquid cytology material over a 5-year period. The positive predictive value for histopathologically confirmed squamous cell carcinoma on surgical follow-up was calculated within each cytologic interpretive category. RESULTS: The HR-HPV PCR results were positive in 50.2% of specimens, negative in 40.9%, and indeterminate in 9.0%. The HR-HPV positivity rate ranged from 0% in specimens categorized as negative for malignancy to 57.3% in cytologically positive specimens, with 19.0%, 41.2%, and 50.0% positivity in the atypical, suspicious, and nondiagnostic categories, respectively. Among cytologically indeterminate specimens with positive HR-HPV PCR results (n = 14), the positive predictive value was 100% (95% confidence interval, 78.5%-100.0%). Blinded slide review additionally identified 15 cytologically positive specimens in which the definitive malignant interpretation depended substantially on HR-HPV positivity; all 15 were confirmed as squamous cell carcinoma. CONCLUSIONS: A positive HR-HPV PCR result on liquid cytology material carries a positive predictive value of 100% for malignancy in cytologically indeterminate head and neck FNA specimens. These findings support integrating HR-HPV PCR analysis into routine cytologic interpretation with the potential to upgrade some indeterminate specimens to malignant when HR-HPV is detected, expediting definitive treatment and sparing patients additional, invasive sampling.

Humans