Search PubMedSearch

SEARCH · Search PubMed

Results for “Surgical Performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

954 records · Page 15Linked to original sources

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and κ statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years ± 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (κ = 0.57-0.96) and clinical T categorization (κ = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (κ = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. © RSNA, 2026 Supplemental material is available for this article.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Diagnostic performance of machine learning models for malignant and non-malignant pleural effusion: Systematic review and meta-analysis.

BACKGROUND: Accurately distinguishing malignant pleural effusion (MPE) from non-malignant pleural effusion is clinically important, but the generalisability and methodological quality of machine-learning (ML) models remain uncertain. METHODS: We searched eight databases to 23 April 2026. Diagnostic performance was pooled using random-effects and Reitsma bivariate models, and study quality was assessed using PROBAST+AI. RESULTS: Forty-two studies were included; 17 contributed to the AUC meta-analysis and 14 to the bivariate analysis. The pooled AUC was 0.90 (95 % CI 0.85-0.94; 95 % prediction interval 0.62-0.98), with sensitivity of 0.80 (95 % CI 0.77-0.83) and specificity of 0.87 (95 % CI 0.79-0.92). Only nine studies reported external, temporal or independent validation. Externally validated studies had a lower pooled AUC than studies without external validation (0.83 vs 0.92), with lower specificity observed in the two externally validated studies contributing sensitivity and specificity data. All 42 development assessments had high overall quality concerns, and all 42 model evaluations were judged at high risk of bias. CONCLUSIONS: ML models showed good apparent accuracy for distinguishing MPE from non-MPE, but the evidence was limited by substantial heterogeneity, high risk of bias and scarce external validation. The pooled estimates reflect the average performance of different selected models rather than the expected accuracy of a single clinical test. ML models should be regarded as adjuncts to existing diagnostic pathways until they are confirmed by rigorous multicentre prospective external validation and clinical-impact studies.

Humans

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Performance of Automated Hematology Analyzer Criteria in Detecting Peripheral Blood Smear Abnormalities: A Systematic Literature Review.

OBJECTIVES: Criteria for visual examination of stained peripheral blood smear (PBS) differ among institutions in the United States and internationally. In an effort to standardize review criteria, the International Consensus Group for Hematology Review (ICGHR) proposed in 2005 a consensus list of rules for CBC findings that should trigger a review of automated cell counter results and potentially lead to further testing or blood smear review. The primary aim of this paper is to report on the published literature in the past 20 years regarding PBS review criteria and their ability to identify relevant peripheral blood abnormalities. METHODS: We performed a systematic review of the published literature from 2005 to 2025 to investigate and summarize PBS review criteria and performance in the context of automated hematology analyzers in clinical laboratories. RESULTS: Of 5351 citations, 68 studies met our search criteria. These studies included 22 countries and all major hematology analyzer manufacturers. Marked variability was observed in study populations, analyzer flagging criteria, details of PBS visual review, definitions of a "positive" smear, and approaches to statistical data analysis. Across studies, the blast flag sensitivity ranged from 18% to 100% while the blast flag specificity ranged from 17% to 100%. Wide ranges in sensitivity/specificity were also seen for atypical and/or abnormal lymphocyte flags across studies. For studies analyzing the same patient population, less striking variation was seen across instruments. CONCLUSIONS: This systematic review provides a 20-year overview of the literature, highlighting significant variability in PBS review criteria, dependence on study design and hematology analyzer, and the importance of developing harmonized evidence-based guidelines.

Humans

External load metrics and monitoring in women's football match play: A systematic review.

This systematic review aimed to identify the most commonly used variables for monitoring external load during elite women's football matches and to compare reporting practices internationally and in Brazil. Searches were conducted in Web of Science, PubMed, and SciELO using the PICOS framework between February and March 2026, resulting in the inclusion of 35 studies. The main outcomes analysed were total distance covered (TD), distance covered across speed zones (HSR, VHSR, sprint), number of accelerations and decelerations, and maximum speed. TD and distance covered across speed zones were the most frequently reported indicators (94.3%), followed by HSR (82.8%) and sprint distance (68.5%). Considerable variability was observed in the classification of speed zones and thresholds used to define accelerations and decelerations, limiting comparisons between studies. External load values varied according to playing position and competition level, with international matches generally imposing greater demands than national competitions. Brazilian research remains limited and demonstrates notable methodological variability. This review proposes standardised speed and acceleration/deceleration thresholds based on the most recurrent ranges reported in the literature, supporting improved consistency in monitoring practices across elite women's football contexts.

Humans

Influence of microplastics on microalgal performance during wastewater polishing.

Microplastics (MPs) are emerging contaminants that are increasingly accumulating in aquatic ecosystems due to excessive anthropogenic activity and insufficient mitigation strategies, posing serious environmental and public health risks. Their impact on wastewater (WW) treatment processes remains poorly understood. This study evaluated the effects of five MPs commonly found in WW - polypropylene, polystyrene, polyamide, low-density polyethylene, and high-density polyethylene - on the physiology and bioremediation performance of the microalga Chlorella vulgaris in synthetic WW (SWW). Metabolic responses were assessed via esterase activity and intracellular reactive oxygen species (ROS), while nitrogen (N), phosphorus (P), and glucose removal were monitored to evaluate bioremediation efficiency. MPs inhibited esterase activity and elevated ROS levels, indicating oxidative stress. Nevertheless, C. vulgaris maintained a high bioremediation capacity (> 75 % N, > 60 % P, and > 70 % for glucose). Environmental conditions modulated microalga response to MPs exposure. Under N-limited conditions, C. vulgaris exhibited enhanced nutrient uptake and biomass production, but a 12 h/12 h light/dark photoperiod reduced N removal but stimulated glucose consumption via heterotrophic metabolism. In contrast, C-limited conditions exacerbated oxidative stress and compromised nutrient removal, resulting in residual concentrations exceeding legal limits. These findings highlight that environmental factors can either mitigate or exacerbate the physiological stress induced by MPs, ultimately affecting WW polishing. This work provides a comprehensive insight into the cellular and metabolic effects of MPs on microalgae and supports C. vulgaris as a resilient and sustainable approach for nutrient and carbon removal in MP-contaminated WW systems.

Microalgae

Prenatal exposure to indoor PM2.5 and children's cognitive performance at 4 years of age: an observational analysis from the UGAAR randomized controlled trial.

Outdoor fine particulate matter (PM2.5) concentrations during pregnancy are linked to reduced cognitive performance in children. We previously reported that portable HEPA filter air cleaners use during pregnancy improved children's mean full-scale IQ (FSIQ), but no previous studies have evaluated the relationship between indoor PM2.5 during pregnancy and FSIQ in childhood. We conducted an observational analysis using data from the Ulaanbaatar Gestation and Air Pollution Research (UGAAR) randomized controlled trial. Using a previously developed model of weekly indoor PM2.5 concentrations, we estimated the average concentrations in participants' homes over the full pregnancy and in each trimester. When the children were four years old, we measured FSIQ using the Wechsler Preschool and Primary Scale of Intelligence (WPPSI-IV). We used multiple linear regression to assess the adjusted relationships between interquartile range (IQR) contrasts in indoor PM2.5 during pregnancy and FSIQ among 475 mother-child dyads. An 8.8 μg/m3 increase in indoor PM2.5 concentration over the full pregnancy was associated with a reduction of 1.4 points (95% CI: -3.4, 0.6) in mean FSIQ. The strongest association between PM2.5 concentrations and FSIQ was in the first trimester, when a 19.1 μg/m3 contrast was associated with a 2.8-point reduction (95% CI: -5.7, 0.2) in mean FSIQ. Indoor PM2.5, particularly during early pregnancy, may impair brain development, leading to lower mean FSIQ scores in four-year old children. These results, combined with our previous analysis of HEPA filter air cleaners, indicate that reducing PM2.5 exposure during pregnancy has beneficial effects on children's cognitive performance.

Humans

Natural deep eutectic solvent in situ formation-based extraction method coupled to high-performance anion-exchange chromatography with pulsed amperometric detection for multiclass carbohydrates in hot pot bases.

A novel method was developed for the simultaneous extraction of fourteen multiclass carbohydrates from high-fat foods via the in situ formation of deep eutectic adducts from analytes and acetate ions. Different natural deep eutectic solvents (NADESs) composed of fructose and organic acids were tested as extraction solvents. A model NADES formulated with sodium acetate and fructose was characterized using Fourier transform infrared (FTIR) spectroscopy and hydrogen nuclear magnetic resonance (1H-NMR) spectroscopy. The critical extraction parameters were systematically optimized using multi-response surface methodology (MRSM) with a central composite design (CCD). The extract was analyzed using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) using a sodium hydroxide-sodium acetate eluent, which did not require organic solvents. This approach exhibited good linearity over the concentration range of 0.02-10 mg L-1, with correlation coefficients (r) ranging from 0.9994 to 0.9999. The limits of detection and quantification were in the ranges of 0.06-0.42 mg kg-1 and 0.19-1.3 mg kg-1, respectively, which were significantly lower than those of liquid chromatography (LC). The protocol was successfully applied to the determination of fourteen carbohydrates in forty-five hotpot seasoning samples. The recoveries ranged from 86.3% to 104.1%, with relative standard deviations (RSDs) of 0.9-7.1%. By integrating multiple techniques, this strategy simplifies operations, shortens extraction time, and achieves baseline separation of three carbohydrate classes that exhibit poor resolution using a conventional LC method. This study describes an efficient procedure for the simultaneous determination of multiple trace-level carbohydrates in complex samples using HPAEC-PAD.

Journal Article

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans

Diagnostic performance of panfungal PCR on tissue specimens for the diagnosis of invasive fungal diseases: a systematic review and meta-analysis of the Fungal PCR Initiative (FPCRI).

UNLABELLED: Invasive fungal diseases are difficult to diagnose because of the limited sensitivity of culture. Panfungal PCR amplicon sequencing assays (targeting ribosomal RNA, such as 18S, 28S, ITS) are recommended for fungal identification in histopathology samples showing fungal elements. However, data describing its overall performance and consistency are lacking. This systematic literature review and meta-analysis assessed the performance of panfungal PCR on formalin-fixed paraffin-embedded (FFPE) and non-fixed (fresh or frozen) tissue samples. A systematic literature search was performed to include studies reporting the use of panfungal PCR for fungal identification in FFPE or non-fixed tissue samples. PCR sensitivity and specificity were assessed using the reference standard of histopathology showing fungal elements. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled estimates were obtained using random-effects meta-analysis. Twenty-eight studies were included. In FFPE samples (18 studies, 852 samples), sensitivity and specificity were 75.4% (95% confidence interval [CI], 59.2-86.6) and 93.5% (70.2-98.9), respectively. Sensitivity in non-fixed samples (13 studies, 207 samples) was 86.5% (74.7-93.3), while specificity could not be assessed (insufficient data). Comparative analyses showed a significantly higher sensitivity of panfungal PCR over culture (88.2%; 76-94.7 vs 52.2%; 39-65, P = 0.001). Sub-analyses could not demonstrate the superiority of one PCR target over another due to limited data. Panfungal PCR exhibited adequate sensitivity and good specificity in FFPE samples. Sensitivity was even higher in non-fixed samples and largely superior to culture. Nevertheless, large interstudy variability was observed, warranting interlaboratory studies to define the optimal PCR target and standardized protocols. IMPORTANCE: Invasive fungal diseases are difficult to diagnose because of the low sensitivity of culture. Panfungal PCRs are widely used for fungal identification in tissue specimens but suffer from heterogeneous procedures and performance. This meta-analysis shows an acceptable sensitivity (75.4% and 86.5% in fixed and non-fixed samples, respectively) and good specificity (93.5%) of panfungal PCR, supporting its use, not only on histopathology-positive fixed samples but also in non-fixed samples concomitantly with other diagnostic tools (cultures and fungal-specific PCRs if available). These results provide a strong basis for further standardization of panfungal PCR techniques via interlaboratory assays to assess reproducibility and optimize analytical protocols. CLINICAL TRIALS: This study is registered with PROSPERO as CRD42023461148.

Humans

Engineering copper ferrite (CuFe2O4) nanocomposites for enhanced eco-friendly photocatalysis: a systematic critical review on mechanisms, performance, and environmental applications.

Water pollution caused by organic and inorganic contaminants, particularly dyes and pharmaceuticals, represents a major environmental challenge. Advanced oxidation processes based on photocatalysts have emerged as efficient and sustainable approaches for water and wastewater treatment. Copper ferrite (CuFe2O4) is considered a promising photocatalyst owing to its narrow bandgap, visible-light activity, chemical stability, and magnetic properties. Despite extensive experimental investigations, a comprehensive systematic comparison of CuFe2O4-based photocatalysts under diverse operational conditions has remained limited. In this study, a systematic review following PRISMA guidelines was conducted using studies published between January 2014 and November 2025 indexed in Scopus, PubMed, Web of Science, and ScienceDirect. From an initial pool of 397 studies, 98 articles met the inclusion criteria. Key parameters&#xa0;-&#xa0;including pollutant type, pH, catalyst dosage, initial pollutant concentration, irradiation time, light source, and degradation efficiency&#xa0;-&#xa0;were quantitatively compared to identify performance trends and operational optima. The results demonstrate that CuFe2O4-based nanocomposites, particularly heterojunction, Z-scheme, and S-scheme architectures combined with TiO2, g-C3N4, graphene, and metal oxides, achieve high degradation efficiencies (often >90&#x202f;%) for a wide&#xa0;range of organic pollutants and selected inorganic contaminants (e.g., Cr(VI)). Enhanced charge separation and suppressed electron-hole recombination were identified as the primary factors contributing to improved photocatalytic activity. In addition, the intrinsic magnetic properties of these&#xa0;nanocomposites enable facile catalyst recovery and reuse. In conclusion, CuFe2O4-based nanocomposites, especially those&#xa0;incorporating advanced heterojunction architectures, emerge as highly efficient and magnetically recoverable photocatalytic platforms for sustainable water and wastewater treatment, with strong potential for scalable implementation and real-wastewater applications.

Catalysis

Diagnostic performance of machine learning models versus established risk stratification for intracranial aneurysm rupture: a systematic review and bivariate meta-analysis.

BACKGROUND: Machine learning (ML) models have been proposed to improve the discrimination of intracranial aneurysm rupture status beyond established clinical risk stratification tools. However, reported performance is heterogeneous and the relative contribution of model architecture and feature dominance remains unclear. METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analyses-diagnostic test accuracy systematic review and diagnostic meta-analysis of studies evaluating ML models for intracranial aneurysm rupture discrimination. PubMed, Embase and CENTRAL were searched to February 2026. Sensitivity and specificity were pooled using a bivariate random-effects model, with summary receiver operating characteristic curves generated across training, internal testing and external validation datasets. Models were compared with regression-based approaches and Population, Hypertension, Age, Size of aneurysm, Earlier subarachnoid haemorrhage, Site of aneurysm (PHASES) scores. Subgroup and meta-regression analyses explored associations between algorithm family and feature domain. RESULTS: Sixty-two retrospective cohorts (29&#x2009;709 patients 209 models) met the inclusion criteria. In training datasets, pooled sensitivity and specificity for ML were 0.81 (95% CI 0.75 to 0.85)&#x2009;and 0.83 (0.80-0.86), with an area under the curve (AUC) of 0.878, exceeding PHASES (AUC 0.667). In testing datasets, ML retained higher discrimination (AUC 0.837) than regression models (0.806) and PHASES (0.646). In external validation, sensitivity was preserved (0.82), but specificity declined (0.66). Deep learning demonstrated the highest AUCs (training and testing). Incorporation of haemodynamic or radiomic features improved pooled discrimination relative to morphology alone. Evidence of small-study effects and mostly unclear Prediction Model Risk Of Bias Assessment Tool ratings were observed. CONCLUSIONS: ML approaches demonstrate higher pooled discrimination for aneurysm rupture status than conventional risk scores in retrospective datasets, but reduced external validation specificity and heterogeneity limit confidence for clinical translation. Prospective, externally validated, calibrated models are required before integration into routine cerebrovascular risk stratification.

Humans

Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.

Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p&#x202f;<&#x202f;0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7&#x202f;h, whereas rapid barcoding required approximately 40&#x202f;h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200&#x202f;min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.

Poliovirus

Immersive virtual reality-assisted anatomy training improves endotracheal intubation performance in simulation: a randomized controlled trial among Chinese non-anesthesiology residents.

INTRODUCTION: This study aimed to compare immersive virtual reality (IVR)-assisted versus conventional anatomy training for teaching endotracheal intubation (ETI) to novice non-anesthesiology residents enrolled in China's Standardized Residency Training program. METHODS: A total of 90 non-anesthesiology residents without prior ETI experience were randomly assigned to either an IVR group receiving IVR-assisted anatomy training (n&#x2009;=&#x2009;45) or a control group receiving conventional anatomy training (n&#x2009;=&#x2009;45). All participants underwent a standardized teaching protocol. The primary endpoint was residents' ETI performance on a simulator, assessed using both the Global Rating Scale (GRS) and a task-specific checklist. The secondary endpoints included changes in written multiple-choice question (MCQ) scores and residents' evaluations of the course. RESULTS: In practical ETI assessments on a manikin, the IVR group achieved significantly higher scores on the task-specific checklist than the control group (90.34&#x2009;&#xb1;&#x2009;2.89 vs. 87.20&#x2009;&#xb1;&#x2009;3.29; p&#x2009;<&#x2009;0.001), whereas GRS scores were comparable between groups. Both groups showed significant post-training improvement in knowledge scores (p&#x2009;<&#x2009;0.001), with the IVR group showing a greater gain in theoretical knowledge (54.0% vs. 36.3%; p&#x2009;<&#x2009;0.001). Participants in the IVR group also expressed a stronger preference for their training method (80.8%) and reported higher levels of motivation, confidence, and enjoyment (all p&#x2009;<&#x2009;0.05). CONCLUSION: IVR-assisted anatomy training enhances the effectiveness of ETI training for novice non-anesthesiology residents, offering an interactive, engaging, and reproducible approach within China's Standardized Residency Training framework.

Humans

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

Comparison of the predictive performance of systemic immune-inflammation index and neutrophil-to-lymphocyte ratio for three-month poor functional outcome in ischemic stroke: a systematic review and meta-analysis.

INTRODUCTION: Ischemic stroke (IS) is a leading cause of global mortality and disability. Early and accurate prognosis is crucial for patient management. The neutrophil-to-lymphocyte ratio (NLR) and systemic immune-inflammation index (SII) are emerging inflammatory biomarkers; however, their relative predictive value for three-month poor functional outcome (modified Rankin Scale [mRS]&#x2009;>&#x2009;2) remains uncertain. METHODS: We systematically searched PubMed, Embase, Web of Science, and the Cochrane Library up to 20 July 2025, adhering to PRISMA guidelines. Observational studies reporting the association of SII or NLR with three-month poor outcome were included. Study quality was evaluated using the Newcastle-Ottawa Scale. Area under the curve (AUC), odds ratios (OR), and standardized mean differences (SMD) were pooled using random-effects models in Stata 16.0. RESULTS: Twenty-one studies involving 7520 IS patients were analysed. NLR demonstrated marginally superior discriminative ability compared to SII (AUC 0.71, 95% CI: 0.67-0.76 vs. 0.68, 95% CI: 0.64-0.71), though this difference was not statistically significant. Elevated NLR was significantly associated with poor outcome (OR = 1.26, 95% CI: 1.17-1.37, p&#x2009;<&#x2009;.001), whereas SII was not (OR = 1.00, 95% CI: 1.00-1.00, p&#x2009;=&#x2009;.384). Both markers showed moderate effect sizes (SMD: NLR = 0.69, SII = 0.72; p&#x2009;<&#x2009;.001). NLR performed better in non-intervention and Chinese subgroups, while SII exhibited consistent AUC values across treatment and ethnic subgroups. CONCLUSION: NLR and SII are accessible prognostic markers in IS. NLR demonstrates superior accuracy and a significant association with poor outcome, while SII shows greater stability across patient subgroups. Both may assist in risk stratification, in resource-limited settings.

Humans

Impact of neoprene wetsuits on lung volumes and work of breathing: implications for military diver safety and performance.

INTRODUCTION: Neoprene wetsuits may impose mechanical constraints on the chest wall, potentially altering respiratory function. This study investigated the impact of neoprene wetsuits on lung volumes, airway mechanics, and work of breathing (WOB) in healthy male divers. METHODS: A randomised crossover trial was conducted with 31 male divers at the Royal Netherlands Navy Diving Medical Centre. Participants underwent pulmonary function testing, including spirometry, body plethysmography, the forced oscillation technique (FOT), and diffusion capacity measurements, both with and without a hoodless standardised 5 mm neoprene full body wetsuit with a neoprene neck seal. Primary outcomes included changes in forced vital capacity (FVC), functional residual capacity (FRC), airway resistance (Raw), reactance (Xrs), and WOB. RESULTS: Wearing a neoprene wetsuit led to statistically significant reductions in FVC (2.8%, P < 0.05), forced expiration in one second (2.9%, P < 0.05), FRC (4.0%, P < 0.05), and expiratory reserve volume (10.9%, P < 0.05), alongside increases in inspiratory capacity and tidal volume. Raw increased significantly (P < 0.05), while the FOT revealed altered airway mechanics, evidenced by increased Xrs at multiple frequencies (P < 0.05). Diffusion capacity remained unchanged, suggesting preserved alveolar-capillary function. CONCLUSIONS: Neoprene wetsuits induce mechanically restrictive effects on the chest wall, reducing static and dynamic lung volumes and increasing WOB. While these changes may not be clinically relevant at rest, their impact needs to be determined during strenuous or prolonged dives, particularly when combined with other equipment that limits thorax excursions. Future research should explore the effects of the military 5 mm wetsuit under immersed conditions to better understand their operational impact on diver performance and safety.

Male