Search PubMedSearch

SEARCH · Search PubMed

Results for “Clinical mastitis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,341 records · Page 15Linked to original sources

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

Compound muscle action potential amplitudes in newborn screen positive spinal muscular atrophy.

OBJECTIVE: To evaluate the utility of compound muscle action potential (CMAP) amplitudes as biomarkers of disease severity in newborn screening (NBS)-positive infants with spinal muscular atrophy (SMA). METHODS: We conducted a retrospective review of 21 infants identified through SMA NBS (11 with 2 SMN2 copies and 10 with 3 SMN2 copies). Baseline and serial right median, ulnar, and fibular motor nerve CMAP amplitudes (millivolts, mV) were obtained during the study. Functional outcomes were assessed using the Children's Hospital of Philadelphia Infant Test of Neuromuscular Disorders (CHOP-INTEND). RESULTS: At baseline, infants with 2 SMN2 copies demonstrated significantly lower median, ulnar, and fibular CMAP amplitudes compared with infants with 3 SMN2 copies (p&#xa0;<&#xa0;0.05). In contrast, baseline CHOP-INTEND scores did not differ significantly between the two groups. Prior to genetic confirmation, a right median CMAP amplitude&#xa0;&#x2265;3.2&#xa0;mV predicted&#xa0;&#x2265;3 SMN2 copies. Following treatment, right median and fibular CMAP amplitudes demonstrated significant improvement over time, including in analyses accounting for SMN2 copies number. CONCLUSION: CMAP amplitudes obtained from multiple upper- and lower-extremity motor nerves provided objective electrophysiological measures that distinguished infants with two versus three SMN2 copies, despite similar baseline CHOP-INTEND scores. Furthermore, CMAP abnormalities were detectable in some cases before confirmatory genetic testing results became available. Serial CMAP measurements demonstrated significant longitudinal changes following treatment, whereas functional assessments approached ceiling values, supporting the potential value of electrophysiological monitoring in the era of disease-modifying therapies. SIGNIFICANCE: CMAP assessment is a useful adjunct in the evaluation of infants identified through SMA NBS.

Humans

Diverse structures of mcr-10-bearing plasmids and high colistin resistance in Enterobacter cloacae complex clinical isolates from South Korea.

BACKGROUND: The emergence of mcr-mediated colistin resistance in Enterobacter cloacae complex (ECC) poses a significant threat to antimicrobial therapy. Among mcr variants, mcr-10 has been identified in various environments, but its genetic diversity, structural context, and functional role in colistin resistance remain unclear. METHODS: We investigated 183 ECC isolates and identified 60 colistin-resistant strains through minimum inhibitory concentration (MIC) testing. The presence of mcr-10 was screened using reference genomes from NCBI, and whole plasmid sequencing was conducted on mcr-10-positive isolates. The genetic environment of mcr-10 was analyzed via synteny and structural annotation. RESULTS: Whole-plasmid sequencing of eight mcr-10-positive ECC isolates identified three replicon types among the mcr-10-harboring plasmids: IncFIB (n=3), IncFII (n=3), and IncFII/IncFIB (n=2). Although all plasmids shared the xerC-mcr-10 cassette, they lacked a conserved backbone and showed diverse genetic contexts with variable insertion sequences near mcr-10, indicating marked structural heterogeneity. No additional antimicrobial resistance genes were detected on these plasmids. When introduced into E. coli DH5&#x3b1;, the plasmids increased colistin MICs only modestly, whereas representative plasmids transferred into colistin-susceptible E. roggenkampii and E. kobei conferred high-level resistance comparable to that of the parental mcr-10-positive isolates. Consistently, qRT-PCR showed higher mcr-10 expression in ECC transformants than in E. coli under colistin exposure, supporting a hostdependent effect on mcr-10-mediated colistin resistance. CONCLUSION: These findings highlight the diversity of mcr-10-carrying plasmids and suggest that mcr-10-mediated colistin resistance is shaped by the host genetic background. Further studies are needed to clarify the mechanisms underlying mcr-10 expression.

Colistin

Systemic biomarkers of treatment response to methotrexate in people with painful knee osteoarthritis: A biological substudy of the PROMOTE randomised controlled clinical trial.

OBJECTIVE: Stratification of therapeutic responses may help identify efficacious therapies for osteoarthritis (OA). In the PROMOTE randomised trial, participants with elevated baseline high-sensitivity C-reactive protein (hs-CRP) showed greater pain reduction after methotrexate treatment. We set out to interrogate a broader panel of serum/plasma inflammatory response markers relevant to methotrexate actions as potential biomarkers of therapeutic effect. Our objectives were to: (i) characterize changes in these systemic markers during methotrexate treatment; determine whether (ii) baseline levels or (iii) changes in any marker during treatment were associated with treatment response; and (iv) compare these findings with the more established clinical inflammatory marker, hs-CRP. DESIGN: Plasma/serum samples from participants in PROMOTE's biological substudy were analysed for 35 inflammatory markers at baseline (pre-treatment) and at 6-months (post-treatment), by MesoScale V-plex multiplex assay. Those with paired biological and clinical data at both baseline and 6-months were included in the substudy analysis set. Relationships between markers and overall data structure were assessed by Pearson correlation and Principal Component analysis. Associations between markers (baseline levels or change over time) and change in average knee pain severity in past week (numerical rating scale, NRS) were evaluated by univariable linear regression, adjusting for baseline age, sex, and body mass index. Least Absolute Shrinkage and Selection Operator (LASSO) regression with bootstrap resampling enabled marker selection. Benjamini-Hochberg correction adjusted for multiple testing (Padj). RESULTS: 87 participants with paired blood marker and clinical data were eligible for substudy analysis. 18/35 markers were quantifiable and analysed. Systemic IL-8 and TNF-&#x3b1; levels decreased (Padj=0.015, 0.048 respectively) while IL-15 increased (Padj=0.033) with methotrexate treatment over 6-months. Analysing within this active treatment randomised arm, higher baseline IFN-&#x3b3; was associated with greater reduction in NRS pain change (0.66 [0.01, 1.31], P=0.047), as was decreasing TNF-&#x3b1; over 6-months (2.25 [0.00, 4.5], P=0.049). LASSO identified higher IFN-&#x3b3;, lower plasma IL-15 and IL-16, and younger age as the most important baseline predictors of pain improvement. hs-CRP was highly selected by LASSO for treatment response in both arms. In a secondary univariate treatment arm-by-biomarker interaction analysis, of the 19 markers, only hs-CRP showed consistent effects in adjusted models (at baseline, coeffic. 2.34 [0.53, 4.15], P=0.001; change over 6-months, (0.36 [0.06, 0.66], P=0.018). CONCLUSIONS: Blood measurement of IFN-&#x3b3;, TNF-&#x3b1;, IL-15 and IL-16 as well as hs-CRP could act as potential markers to stratify the treatment response by average knee pain to methotrexate in knee osteoarthritis.

Humans

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Validation of the lung immune prognostic index in extensive-stage small cell lung cancer: Post hoc analysis of the caspian and IMpower133 phase 3 trials.

BACKGROUND: The Lung Immune Prognostic Index (LIPI) is an inflammation-based biomarker associated with outcomes to immunotherapy across several tumor types. Its prognostic value in extensive-stage small-cell lung cancer (ES-SCLC), however, remains insufficiently validated. We aimed to validate the prognostic impact of LIPI in ES-SCLC using data from two phase III trials. METHODS: Patients enrolled in the CASPIAN (NCT03043872) and IMpower133 (NCT02763579) trials were included. LIPI groups were defined as good (dNLR<3 and LDH<ULN), intermediate (dNLR&#x2265;3 or LDH&#x2265;ULN) and poor (dNLR&#x2265;3 and LDH&#x2265;ULN). Overall survival (OS) and progression-free survival (PFS) were assessed across LIPI categories and treatment arms. RESULTS: LIPI was available for 1140 patients (Good: 34%, Intermediate: 49%, Poor: 17%), including 708 treated with chemotherapy-immunotherapy and 432 with chemotherapy alone. Poor LIPI was associated with unfavorable characteristics, including lower albumin levels and higher rate of liver metastases. Median OS was 14.6 months (95%CI: 12.4-15.9) for LIPI Good, 10.9 (10.1-11.5) for Intermediate, and 8.4 (7.1-9.3) for Poor (p&#x202f;<&#x202f;0.0001). In multivariate models adjusted on gender, age, ECOG, treatment arm and metastatic sites, LIPI remained an independent prognostic factor for OS (HR Poor vs. Good: 1.76, 95%CI: 1.45-2.15, p&#x202f;<&#x202f;0.001) and PFS (HR: 1.59, 95%CI: 1.33-1.90, p&#x202f;<&#x202f;0.001). Although patients with poor LIPI derived limited benefit from immunotherapy, no significant treatment-LIPI interaction was observed. CONCLUSION: This large post hoc analysis confirms LIPI as a robust and clinically applicable prognostic biomarker in ES-SCLC. Patients with poor LIPI have substantially worse outcomes and limited benefit from immunotherapy, highlighting the need for novel therapeutic strategies in this subgroup.

Humans

Immunomodulatory effects of palm-derived tocotrienol-rich fraction in healthy volunteers following influenza vaccination: A randomised clinical trial.

Most studies on vitamin E and immunity have focused on tocopherols, but the tocotrienol-rich fraction (TRF) from palm oil may exert stronger immunomodulatory effects. This study investigated the effect of various TRF doses on the immune response to influenza immunisation in healthy adults. We hypothesized daily supplementation with lower doses of TRF can boost immune response to the influenza vaccine in healthy Individuals. In a double-blind placebo-controlled trial, 150 participants (&#x2265;18 years) were randomised to receive placebo or TRF (50, 100, 200, or 400 mg) daily for 2 months, with vaccination on day 28. Blood samples collected on days 0, 28, and 56 were analyzed for humoral and cellular immunity, antioxidant status, and plasma concentrations of vitamin E. TRF significantly augmented anti-influenza antibody production across all doses, with the 400 mg group exhibiting the highest titers. A selective Th1-type immune response was observed, characterized by significant IFN-&#x3b3; production upon restimulation in all TRF-supplemented groups compared with placebo. Plasma IL-12 was elevated in the highest dose, whereas the amount of EBI3 produced increased across a broader range of doses compared to placebo. TRF supplementation was associated with increased antioxidant enzyme activities and stable malondialdehyde activity. Elevated &#x3b1;-tocopherol concentrations observed, primarily at higher doses. Supplementation with TRF can enhance immune response to influenza immunisation by modulating humoral, Th1 responses and improving antioxidant status. Critically, antibody production increased similarly across all TRF doses, suggesting that lower doses may offer a cost-effective strategy for supporting humoral immunity, while higher doses provide broader immunomodulatory benefits.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Clinical Utility of Ultra-Widefield Swept-Source OCT for Intraocular Tumors: Comparison With Ultrasonography, SD-OCT, and MRI.

PURPOSE: To evaluate the clinical performance of ultra-widefield swept-source optical coherence tomography (UWF-OCT) in the assessment of choroidal tumors and to compare it with ultrasonography (US), spectral-domain (SD)-OCT, and magnetic resonance imaging (MRI). DESIGN: Retrospective diagnostic comparison. SUBJECTS: Thirty-nine eyes from 39 patients diagnosed with choroidal tumors at a single tertiary referral center. METHODS: This retrospective diagnostic comparison evaluated patients diagnosed with choroidal tumors at a single tertiary referral center between January 2023 and August 2025. All patients underwent UWF-OCT imaging at diagnosis. Tumor measurements obtained with UWF-OCT were compared with US, SD-OCT, and MRI. Comparative analysis among imaging modalities and predictors affecting UWF-OCT applicability was performed. MAIN OUTCOME MEASURES: Tumor thickness (mm) and largest basal diameter (LBD, mm) measurements, and complete measurability rate across different tumor size categories. RESULTS: Thirty-nine eyes from 39 patients (mean age 59.2 &#xb1; 16.9 years) were analyzed, including 27 choroidal melanomas (69.2%), 5 metastatic tumors (12.8%), 4 hemangiomas (10.3%), 2 osteomas (5.1%), and 1 (2.6%) indeterminate choroidal melanocytic lesion. UWF-OCT successfully measured both tumor thickness and largest basal diameter (LBD) in 100% (31/31) of small and medium choroidal tumors, substantially outperforming SD-OCT (complete measurement achieved in 63.6% of small tumors, and 0% of medium or large tumors). UWF-OCT measurements were systematically smaller than ultrasonography (thickness: -32.3%, P < .01; LBD: -11.1%, P < .01) and MRI (thickness: -29.2%, P < .01). Mushroom-shaped tumor morphology was the strongest negative predictor of UWF-OCT quality (OR = 0.015, 95% CI 0.001-0.196, P < .01). UWF-OCT's complete measurability was limited in large tumors (12.5%, 1/8). CONCLUSIONS: UWF-OCT provides precise, noninvasive, single-scan assessment of small-to-medium choroidal tumors with detailed structural visualization. It may be particularly useful for dome-shaped tumors, while multimodal imaging with US and MRI remains optimal for complex morphologies. Overall, UWF-OCT represents a valuable tool for diagnosis and treatment planning, with potential utility for longitudinal follow-up in choroidal tumor management.

Humans

Nipocalimab Phase 3 Dose Selection for Severe Hemolytic Disease of the Fetus and Newborn.

Nipocalimab, a neonatal Fc receptor (FcRn) blocker, is under evaluation for severe hemolytic disease of the fetus and newborn (HDFN). In the Phase 2 UNITY trial, weekly intravenous antenatal treatment with nipocalimab at dose regimens of 30 and 45 mg/kg prevented fetal anemia requiring intrauterine transfusion (IUT) in 54% of high-risk pregnancies and delayed the need for IUTs versus their previous pregnancies in the remaining 46% of pregnancies. This analysis aimed to select a weekly dose regimen of nipocalimab for the Phase 3 study in severe HDFN (NCT05912517) that maintains FcRn blockade throughout antenatal treatment, including with an unplanned dosing delay of up to 3 days. Observed pharmacokinetic/pharmacodynamic (PK/PD) data from UNITY (i.e., nipocalimab concentrations, FcRn occupancy, and serum IgG) were analyzed using a model-based approach. A PK/PD model originally developed in nonpregnant participants was updated to incorporate gestational weight gain. Nipocalimab PK and FcRn occupancy were described by a two-compartment model with nonlinear, dose-dependent PK, which captured longitudinal PK, FcRn occupancy, and IgG profiles during dosing and return toward baseline postpartum after discontinuation. Both 30 and 45 mg/kg achieved &#x223c;80%-85% reductions in maternal IgG; however, 30 mg/kg showed greater variability in predose trough concentrations, increasing the risk of falling below concentrations required for full FcRn occupancy across antenatal treatment. Simulations incorporating PK/PD variability indicated that 45 mg/kg weekly per current weight maintained full FcRn occupancy in >95% of pregnant individuals, even with dosing delays up to 3 days. Exploratory exposure-response analyses supported 45 mg/kg for the Phase 3 HDFN study.

Humans

Determinants of Nonspecific Response to Treatment in Randomized Controlled Trials of Major Depressive Disorder: A Narrative Review.

The design, conduct, and interpretation of double-blind randomized placebo-controlled clinical trials in major depressive disorder (MDD) are complicated by determinants of nonspecific response to treatment (NSRT). This narrative review provides a comprehensive overview of the determinants of NSRT in randomized controlled trials (RCTs) for MDD, including the placebo effect, factors related to measurement of the primary endpoint, the inclusion of misdiagnosed patients, the relapsing-remitting course of MDD, and factors related to functional unblinding. Potential strategies to reduce the impact of the determinants of NSRT and to improve the interpretation of RCT outcomes in MDD are also summarized. These strategies include use of centralized rating and standardized rater training, independent diagnostic confirmation, optimized site selection, minimizing financial incentives, exclusion of subjects participating in multiple clinical trials, exclusion of patients with unstable major depressive episode trajectories, and use of active placebo and alternative trial designs. Uniformity among experts in the definitions of determinants of NSRT and related concepts, as well as in strategies to address them, may facilitate progress in the development of novel treatments for MDD.

Humans

Reduced Length of ADT and ARTA With XRT in High-Risk Prostate Cancer (RELAX): A Randomised Controlled Trial.

AIM: To assess the efficacy of a short, intensified regimen of androgen deprivation therapy (ADT) and androgen receptor-targeted agent (ARTA) with curative-intent external beam radiotherapy (XRT) for high-risk prostate cancer (HRPCa) staged with prostate specific membrane antigen (PSMA) imaging. MATERIALS AND METHODS: The RELAX (Reduced Length of ADT and ARTA with XRT in high-risk prostate cancer) trial is a multicentre, phase II randomised non-inferiority trial comparing 9 months of ADT and 6 months of ARTA against the standard 24-month ADT, with definitive dose-escalated hypofractionated pelvic radiotherapy for PSMA-staged non-metastatic HRPCa. The primary endpoint is 5-year disease-free survival (DFS), defined from randomisation to first biochemical or clinico-radiological recurrence or any-cause death. Secondary endpoints include biochemical failure-free survival, metastasis-free survival, overall survival, testosterone recovery, treatment-related adverse effects, and patient-reported outcomes. Participants are monitored with serial serum PSA and testosterone levels, CTCAE and PRO-CTCAE assessments, and PSMA-PETCT at recurrence. The non-inferiority margin is set at 10% absolute difference from an expected 5-year DFS of 85% in the standard arm, with intention-to-treat analysis. The trial is ethics board approved and funded by institutional intramural grant, and registered on clinicaltrials.gov (NCT06818682). RESULTS: The planned accrual of 206 participants commenced in February 2025, with nearly a third of enrolment completed till date. CONCLUSION: The RELAX trial incorporates contemporary standards of PSMA-based staging, dose-escalated hypofractionated radiotherapy, and ARTA for HRPCa. The results are expected to inform the efficacy of a shorter, intensified androgen suppression strategy against the prevailing standard of long-term ADT for these patients.

Humans

Clinical applications of digital twin technology in In Vitro Fertilisation.

BACKGROUND: Digital twin technology, originating from aerospace and manufacturing industries, has emerged as a transformative tool in healthcare. In vitro fertilisation (IVF) faces persistent challenges including suboptimal embryo selection, unpredictable treatment outcomes, and limited personalisation of protocols. Despite advances in assisted reproductive technology, existing literature exhibits fragmentation: artificial intelligence applications in embryo selection, ovarian stimulation, and endometrial assessment have been developed independently without systematic integration into comprehensive treatment frameworks. Digital twin technology offers unprecedented opportunities to create virtual replicas of biological systems, enabling real-time monitoring, predictive modelling, and personalised treatment strategies. AIM: This narrative review aims to critically examine the current applications of digital twin technology in IVF, evaluate its potential benefits and limitations, synthesize existing evidence into an integrative conceptual model, and identify future directions for implementation in reproductive medicine. METHOD: A comprehensive narrative review was conducted using PubMed, Scopus, Web of Science, and IEEE Xplore databases. A narrative review approach was selected over systematic review to accommodate the heterogeneity of evidence types in this emerging field, including theoretical frameworks, simulation studies, and proof-of-concept implementations that would be excluded from systematic reviews. Search terms included "digital twin," "IVF," "in vitro fertilisation," "assisted reproductive technology," "embryo selection," and "predictive modelling." Studies published between 2015 and 2025 were included, focusing on original research articles, systematic reviews, and proof-of-concept studies describing digital twin applications in reproductive medicine. RESULTS: Digital twin technology in IVF demonstrates significant potential across multiple domains including embryo development simulation, ovarian response prediction, endometrial receptivity modelling, and personalised stimulation protocols. Current applications integrate artificial intelligence, machine learning algorithms, time-lapse imaging, and omics data to create comprehensive virtual models. Early evidence suggests improvements in embryo selection accuracy, ovarian response prediction, and treatment protocol optimization, though large-scale randomized controlled trials remain limited. Implementation challenges include data integration complexity, computational requirements, regulatory considerations, and validation requirements. CONCLUSION: Digital twin technology represents a paradigm shift in IVF practice, offering personalised, predictive, and precision medicine approaches. This review synthesizes existing evidence to propose an integrative conceptual model for digital twin implementation across the IVF treatment spectrum, identifies critical knowledge gaps, and establishes research priorities to advance clinical translation. Despite current limitations, continued advancement promises improved success rates and patient outcomes.

Humans

Thoracic paravertebral block with different doses of liposomal bupivacaine versus ropivacaine for postoperative analgesia in single-port thoracoscopic lung surgery: a randomized clinical trial.

OBJECTIVE: To evaluate the analgesic efficacy of thoracic paravertebral block (TPVB) with different doses of liposomal bupivacaine (LB) or ropivacaine in patients undergoing single-port thoracoscopic lung surgery. METHODS: A total of 105 patients scheduled for video-assisted single-port thoracoscopic lung surgery were randomized in a 1:1:1 ratio into three groups: low-dose LB group (group LL), high-dose LB group (group HL), or ropivacaine group (group R). All received ultrasound-guided TPVB at the T5/6 level preoperatively. The primary outcome was the area under the curve (AUC) of NRS of pain at activity (AUC-aNRS) from 1 to 72&#x2009;h postoperatively. Secondary outcomes included the AUC of NRS of pain at rest (AUC-rNRS) from 1 to 72&#x2009;h postoperatively, NRS of pain at rest and at activity at 1, 6, 24, 48, and 72&#x2009;h postoperatively, and the cumulative opioid consumption at 24, 48, and 72&#x2009;h postoperatively. Additionally, postoperative recovery and adverse events were assessed. RESULTS: AUC-aNRS differed significantly among groups (p = 0.0092), with high-dose LB lower than low-dose LB (p = 0.0071), but not versus ropivacaine. No significant difference was found in AUC-rNRS (p&#x2009;>&#x2009;0.05). The group-by-time interactions for NRS of pain at rest and at activity were not significant (p&#x2009;>&#x2009;0.05). Cumulative opioid consumption at 24, 48, and 72&#x202f;h was lower in group HL versus group LL (all p < 0.017), but not versus ropivacaine. Postoperative recovery and adverse events showed no differences (p&#x2009;>&#x2009;0.05). CONCLUSION: LB combined with TPVB is not superior to ropivacaine for postoperative analgesia in single-port thoracoscopic lung resection.

Humans

Precision Oncology in Hepatopancreatobiliary Cancer Surgery.

Advances in technology have allowed for the characterization of tumors at the genomic, transcriptomic, and proteomic levels. There are well-established targets for biliary tract cancers, with exciting new targets emerging in pancreatic ductal adenocarcinoma and potential targets in hepatocellular carcinoma. Taken together, these data suggest an important role for molecular profiling for personalizing cancer therapy in advanced disease and need for design of novel neoadjuvant studies to leverage these novel therapeutics perioperatively in the surgical patient.

Humans

Three-Dimensional Fracture Mapping of the Terrible Triad of the Elbow: Morphological Characteristics and Clinical Implications.

BACKGROUND: The morphology of fractures in the terrible triad of the elbow (TTE) is complex, and precise management relies on a profound understanding of this morphology. This study aims to systematically analyze, for the first time, the distribution and morphological characteristics of TTE fracture lines using three-dimensional (3D) imaging technology. METHODS: Clinical data and thin-slice CT scans of 112 patients with TTE from January 2021 to December 2024 were retrospectively included. 3D fracture models were reconstructed using Mimics software. Virtual reduction and standardized alignment were performed using 3-matic software. Fracture lines were mapped onto standard ulnar and radial templates, and 3D fracture heat maps were generated using the E-3D software to demonstrate the high-frequency distribution zones of the fracture lines visually. Statistical analysis was performed using SPSS software (version 21.0, IBM Corp., Armonk, NY, USA). Continuous variables were compared using one-way analysis of variance (ANOVA), and categorical variables were compared using the chi-square test (&#x3c7;2 test). A two-tailed p&#x2009;<&#x2009;0.05 was considered statistically significant. RESULTS: The study revealed distinct patterns in the distribution of TTE fracture lines. In the coronoid process, the fracture "hot zone" presented as an annular high-density band extending from the lateral middle aspect to the tip. In the radial head, an oblique high-density band was observed in the anterolateral quadrant of the articular surface. The radial neck exhibited a circumferential high-density zone, which was most prominent in the anterolateral aspect. Statistical analysis indicated a significant correlation between age and fracture complexity; the proportion of Regan-Morrey type III coronoid fractures and Mason type III radial head fractures was significantly higher in elderly patients (>&#x2009;60&#x2009;years) (p&#x2009;<&#x2009;0.05), suggesting that advanced age is a significant risk factor for complex fractures. CONCLUSION: This study is the first to visually reveal the Collaborative Distribution Patterns of TTE fracture lines using 3D fracture mapping technology. This model provides morphological evidence for understanding the injury mechanism of TTE and offers an anatomical framework that may assist surgeons in individualizing surgical approaches and fixation strategies.

Humans

Applications of artificial intelligence in robot-assisted surgery: a systematic review.

To characterize applications of artificial intelligence (AI) in robot-assisted surgery, summarize technical and clinical performance, and assess the quality of the available evidence. PubMed, Web of Science Core Collection, and Scopus were searched for English-language journal articles published from 1 January 2020 through 31 October 2025. Randomized, observational, model-development, validation, and feasibility studies evaluating AI in robot-assisted surgery or closely related image-guided minimally invasive workflows were eligible. Two reviewers independently performed study selection, data extraction, and risk-of-bias assessment. Owing to heterogeneity in surgical procedures, AI tasks, analytical units, validation strategies, and outcomes, findings were synthesized descriptively without statistical pooling. The review was registered in the International Prospective Register of Systematic Reviews (CRD420251175699). Seventeen studies were included: seven clinical prediction or decision-support studies, eight intraoperative recognition, segmentation, or image-guided studies, and two training or workflow studies. Five prediction studies reported area-under-the-curve values of 0.74-0.95. Technical studies reported F1 or Dice scores of 0.525-0.995 and task-specific accuracies of 0.840-0.998. Two randomized studies suggested benefits for personalized suturing feedback and automated camera control, but neither established improved patient outcomes. Only one study had low overall risk of bias; the remaining studies were at high or unclear risk or raised some concerns. AI applications in robot-assisted surgery show promise for prediction, intraoperative perception, training, and workflow support. Evidence primarily demonstrates technical feasibility rather than established clinical effectiveness. Independent multicenter validation and prospective evaluation of patient, educational, and workflow outcomes are required before widespread implementation.

Robotic Surgical Procedures

Characterization of local tolerability of TV-46000, a long-acting subcutaneous formulation of risperidone for the treatment of schizophrenia.

TV-46000 is a long-acting injectable antipsychotic (LAI) approved for the treatment of adults with schizophrenia and bipolar I disorder. LAIs like TV-46000 can improve adherence and reduce relapse in patients with schizophrenia; however, injection site reactions (ISRs) can contribute to LAI discontinuation. ISRs with TV-46000 treatment were characterized using data from two phase 3 trials of patients with schizophrenia (RISE [NCT03503318], SHINE [NCT03893825]) and a phase 1 study of patients with schizophrenia or schizoaffective disorder. Patients in the pooled safety population (aged 16-67 years) from RISE and SHINE (n&#x202f;=&#x202f;525&#x202f;TV-46000, n&#x202f;=&#x202f;179 placebo) received 4554&#x202f;TV-46000 injections and 2721 placebo injections. ISRs were reported in 19&#x202f;% (n&#x202f;=&#x202f;102) of patients who received TV-46000, corresponding to an exposure-adjusted event rate (EAER)/100 patient-years of 48.67. ISRs led to 9 (1.7&#x202f;%) treatment discontinuations of TV-46000. The most frequently reported ISR adverse events were injection site pain (EAER, 15.38, n&#x202f;=&#x202f;36 [7&#x202f;%]) and injection site nodule (EAER, 12.01, n&#x202f;=&#x202f;35 [7&#x202f;%]). ISR frequency and pain and nodule adverse event frequency decreased after the first injection. In the phase 1 study (n&#x202f;=&#x202f;99), mean injection site pain scores were highest immediately after injection, showed a notable decrease within 10&#x202f;min of injection, and further decreased within 1&#x202f;h after injection. In conclusion, for >4500 injections evaluated, ISR rates with TV-46000 were modest. Most ISRs were mild or moderate and rarely led to treatment discontinuation. Results support the favorable tolerability of TV-46000 as a treatment for schizophrenia in adults.

Humans