Search PubMedSearch

PubMed · 41607037

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

Abstract

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Explore related subjects

Keep this discovery

BibTeXRIS

Maryuri Mac&#xed;as Bautista, Priscilla Barbosa Ferreira Soares, Airin Karelys Avenda&#xf1;o Rondon, Laryssa Silva da Cunha, Ianca Daniele Oliveira de Jesus, Rodrigo Silva Moreira, Gisele Rodrigues da Silva, Liran Levin, Carlos Jos&#xe9; Soares. 2026-01-28. Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.. https://doi.org/10.1111/edt.70059

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Effects of carbohydrate mouth rinse on psychophysiological responses, kinematic variables and technical actions during small-sided soccer games.

BACKGROUND: This study investigated the effects of carbohydrate mouth rinsing (CHOMR) on various psychophysiological, kinematic, and technical actions during 4-a-side small-sided soccer games (SSGs). METHODS: In a randomized, crossover, double-blind design, 16 young male soccer players (age: 15&#x2009;&#xb1;&#x2009;1 years; height: 172.6&#x2009;&#xb1;&#x2009;7.0&#x2009;cm; body mass: 57.8&#x2009;&#xb1;&#x2009;7.9 kg) participated in two 4-a-side SSGs separated by one week following either CHOMR or placebo (PLA). During each SSGs, heart rate (HRmean, %HR, and HRmax), rating of perceived exertion (RPE), enjoyment, visual analogue scale (VAS) to perceived mental fatigue, mood states, total distance (TD), high-speed running distance (HSRD), average metabolic power (AMP), high metabolic load distance (HMLD), sprint distance (SD), acceleration (ACC), deceleration (DEC), and technical actions (e.g. passing, tackling, shooting, and interceptions) were assessed. RESULTS: Compared with PLA, CHOMR resulted in significantly higher RPE (p&#x2009;=&#x2009;0.025, g&#x2009;=&#x2009;0.86) and significantly lower VAS scores (p&#x2009;=&#x2009;0.010, g&#x2009;=&#x2009;-0.71). In addition, the CHOMR condition showed significantly higher values for interceptions, successful tackles, unsuccessful tackles, unsuccessful shots, and goals (p&#x2009;<&#x2009;0.05, g&#x2009;=&#x2009;0.96-2.02), whereas block values were significantly higher in the PLA condition. There were no statistically significant differences in HRmean, %HR, HRmax, enjoyment, TD, HSRD, AMP, HMLD, SD, ACC, DEC, successful passes, unsuccessful passes, successful shots, or mood states between the conditions (p&#x2009;>&#x2009;0.05). CONCLUSION: The current study findings suggest that CHOMR may enhance selected technical actions and lower VAS scores during 4-a-side SSGs, although it was also associated with higher RPE and did not alter the kinematic responses. In conclusion, CHOMR was associated with higher RPE, lower mental fatigue, and selective improvements in technical actions, with no significant effects on kinematic variables or HR.

Humans

Do wound protectors reduce contamination in total shoulder arthroplasty? A randomized controlled trial.

HYPOTHESIS: Cutibacterium acnes is the most frequent cause of shoulder prosthetic joint infection with skin edges as a source of wound contamination. The primary purpose of this study was to determine if the use of a wound protector device decreases the deep wound bacterial colonization in primary shoulder arthroplasty. The secondary purpose was to assess the effect of device usage on deltopectoral muscle and cephalic vein injury. METHODS: This was a prospective, randomized controlled trial. A total of 100 patients undergoing primary total shoulder arthroplasty were enrolled and randomized into 2 groups: a wound protector group and a control group. Five patients withdrew from the study, leaving 48 patients in the wound protector group and 47 controls. Three deep wound culture swabs were taken after final arthroplasty implantation. The surgeon also graded deltoid, pectoralis major, and cephalic vein injury on a 0-3 scale based on modification to the Tscherne classification of soft tissue injury. The primary outcome of this study was positive culture results for C acnes. Secondary outcomes included total bacterial culture positivity as well as soft tissue injury grades. A subanalysis removing likely contaminant positive cultures (growth >7 days and 1 colony only) was also performed. Comparisons between groups were made using Fisher exact test for categorical outcomes and t tests and Mann-Whitney U tests for continuous variables. RESULTS: The use of a wound protector did not result in any significant differences compared with controls in the rate of positive cultures for C acnes (15% vs. 21%, P = .593) or all bacteria (15% vs. 26%, P = .304). Removing likely contaminant positive cultures did not demonstrate any significant difference in culture positivity (9% vs. 17%, P = .355, for C acnes; 9% vs. 19%, P = .231, for all bacterial species). The wound protector group had better soft tissue injury scores for the deltoid muscle (P < .001) and pectoralis muscle (P < .001). No difference in cephalic vein injury was noted between the 2 groups (P > .05). No difference in surgical time was noted. CONCLUSION: The use of a surgical wound protector device in total shoulder arthroplasty did not significantly decrease bacterial colonization of the deep wound. However, soft tissue damage to the deltoid and pectoralis muscle was less severe in the wound protector group. These findings suggest that this device reduces iatrogenic soft tissue injury.

Humans

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

OBJECTIVES: To compare the clinical performance of Amber Mill (AM) and IPS e.max CAD (EM) lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) materials in posterior Class II inlay restorations and characterise their baseline properties. METHODS: Thirty-four adults received paired AM and EM posterior Class II inlays (68 restorations) in a triple-blind randomised split-mouth trial followed for 48 months. Restorations were evaluated at baseline and annually using revised World Dental Federation (FDI) criteria, with fracture and retention as the primary endpoint. Baseline characterisation included flexural strength, shear bond strength, translucency parameter, and scanning electron microscopy. McNemar, Wilcoxon signed-rank, Friedman, one-way analysis of variance, Tukey post hoc, and inter-rater agreement analyses were used. RESULTS: At 48 months, 18 paired participants were available for primary analysis. Failures occurred in 2 of 18 AM restorations and in 3 of 18 EM restorations, corresponding to success rates of 88.9% and 83.3%, respectively, with no significant between-material difference (McNemar p = 1.000). No catastrophic bulk ceramic fracture was observed. Secondary FDI scores remained mostly within the clinically acceptable range; marginal staining deteriorated over time in both groups (p < .001) without significant between-material differences. Baseline material testing showed significant material- and translucency-dependent differences in flexural strength, shear bond strength, and translucency. CONCLUSIONS: Within the limitations of the 48-month follow-up and the tested Class II inlay indication, AM showed clinical performance comparable to EM. Observed clinical complications were related to retention or marginal/interface behaviour. CLINICAL SIGNIFICANCE: For posterior Class II lithium disilicate CAD/CAM inlays, medium-term complications were mainly retention/interface-related, suggesting adhesive-interface durability may be as important as baseline ceramic strength.

Humans